0% found this document useful (0 votes)
679 views3 pages

Mud-Gas Separator Sizing Worksheet: Prerecorded Information

The document is a mud-gas separator sizing worksheet that contains fields to input data on the mud-gas separator, kick details from a well including mud weight and pressures, calculations to determine the peak gas flow rate, and minimum separator size requirements. All the fields are blank, indicating no actual well or separator specifications have been provided yet.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
679 views3 pages

Mud-Gas Separator Sizing Worksheet: Prerecorded Information

The document is a mud-gas separator sizing worksheet that contains fields to input data on the mud-gas separator, kick details from a well including mud weight and pressures, calculations to determine the peak gas flow rate, and minimum separator size requirements. All the fields are blank, indicating no actual well or separator specifications have been provided yet.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 3

MUD-GAS SEPARATOR SIZING WORKSHEET

Prerecorded Information SPM psi bbl/stk bbl/min


A. Slow Pump Rate 0 0 0.0000 0.00

Mud-Gas Separator Data


B. Separator body Internal Diameter 0 inches
C. Gas Vent Line Internal Diameter 0 inches
D. Gas Vent Line Effective Length (Le = L + Equivalent Length) 0 feet

Kick Data
E. Old Mud Weight 0 lb/gal
F. Initial SIDPP 0 psi
G. Initial SICP 0 psi
H. Pit Gain 0 bbls
I. True Vertical Depth 0 feet
Annulus Capacity Factor 0.0000 bbl/ft

Peak Gas Flow Rate Calculation


J. PcMAX, from Driller's Method Killsheet 0 psi

K. Volume Gas Upstream of Choke from Driller's Killsheet 0.0 bbls

L. Time to Pump Gas Out of Well 0 min

M. Volume of Gas Downstream of Choke 0 bbls

N. Average Gas Flow Rate 0 SCF/D

O. Peak Gas Flow Rate

0 SCF/D

Vent Line Friction Pressure Calculation


P. Vent Line Friction = 0.0 psi

Mud Leg Calculation


Q. Minimum Mud Leg Required 0.0 feet

Separator ID Calculation
R. Mud Droplets Falling Velocity
0.00 ft/s

S. Minimum Separator Internal Diameter (to separate mud droplets from gas)

0.0 inches

T. Minimum Separator Internal Diameter (to separate gas from gas cut mud)
0.0 inches
NOTE: You can either directly enter the SICP, SIDP, and
ACF, OR you can fill in the blanks below to
have them calculated based on an assumed
underbalance and well geometry.

0 = Degree of underbalance, ppg


0 = Length of DC's #DIV/0! = Volume of Kick Opposite collars,bbl
0 = Hole size/Casing ID #DIV/0! = Volume of Kick Opposite DP,bbl
0 = DC size
0 = DP size

You might also like