6-52 GHz PDH/SDH DIGITAL RADIO SYSTEM
Section II OPERATION
CONTENTS
TITLE PAGE
CL-1
CONTENTS ROI-S05749
TITLE PAGE
CL-2
2 pages
ROI-S05749 GENERAL
1. GENERAL
This section provides instructions for operation of the 6 to 52 GHz PDH/
SDH microwave radio system.
1-1
GENERAL ROI-S05749
PASOLINK NEO
MDP-150MB-1AA 0678
MODEM(1) INTFC (1) INTFC (2) (H2930)
INDOOR UNIT
SER. No. DATE ,
WEIGHT: 4 kg (WITH OPTION)
MODEM(2) CTRL −48 V 2.5A (WITH ODU & OPTION)
NEC Corporation TOKYO JAPAN MADE IN JAPAN
! IF IN/OUT G PULL
TX PWR
RX ODU
XPIC MD/ ALM
XIF IN XIF OUT XPIC CTRL RESET CBL SELV PWR 2M IN/OUT-A 2M IN/OUT-B
100M PORT 1 PORT 2 100M
G
G
IDU 1+0
! IF IN/OUT
TX G PULL
PWR
RX ODU
XPIC MD/ ALM
XIF IN XIF OUT XPIC CTRL RESET CBL SELV PWR 2M IN/OUT-A 2M IN/OUT-B
100M PORT 1 PORT 2 100M
G
G
IDU 1+1
RX LEV
MON IFL FG
ODU
1-2
2 pages
ROI-S05749 OPERATING EQUIPMENT
2. OPERATING EQUIPMENT
The indicators, switches, interface terminals and jacks for wiring with the
associated equipment are described here.
The IDU component modules are plugged-in from front of the IDU shelf.
The mounting location of each module is shown in Fig. 2-1.
2-1
OPERATING EQUIPMENT ROI-S05749
1 2
! IF IN/OUT
G
TX
RX
XPIC
RESET
PWR
ODU
MD/
CBL SELV
PULL
4 5
XIF IN XIF OUT XPIC CTRL PWR
G
G
PROTECT PASOLINK NEO
3 MAINT
MEMORY
IDU
LCT NMS NE AUX/ALM SC IN/OUT EOW CALL MMC
1
2 7
! IF IN/OUT
G
TX
RX
XPIC
RESET
PWR
ODU
MD/
CBL SELV
PULL
6
XIF IN XIF OUT XPIC CTRL PWR
G
G
PROTECT PASOLINK NEO
3 MAINT
MEMORY
IDU
LCT NMS NE AUX/ALM SC IN/OUT EOW CALL MMC
H2930 MDP-150MB-1AA
No. UNIT/MODULE NAME Expandable REMARKS
1 + 1 system
1 + 0 system
1 H2931 RACK √
2 H2940 MODEM √
QPSK/16QAM/32QAM/128QAM *1
H2940 MODEM − √
3
H3040 DC-DC CONV (√) — -20 to -60/+20 to +60 VDC *2
H2960 STM-1 INTFC (√) STM1-E/O-S-1.1/L-S-1.1 *3
4 H2965 LAN/WS INTFC (√) SDH 2-Port-LAN
H3021 GbE INTFC (√) SDH-GbE
H2960 STM-1 INTFC (√) STM1-O-S-1.1/L-S-1.1 *3 for APS
5
H2965 LAN/WS INTFC (√) WS-SC-LAN/WS/SC-LAN *3
H2980 16E1 INTFC (√) PDH-16E1 e/w 2 Port LAN*3
6 H3000 48E1 INTFC (√) PDH-48E1
H3010 E3 INTFC (√) PDH-E3 e/w 4/8E1, 2 Port LAN *3
7 H2950 CTRL √
2-2
ROI-S05749
RX LEV
MON IFL FG
6 - 52 GHz ODU
TRP-( )G-1B
MODULE
OPERATING EQUIPMENT
6 GHz 7 GHz) 8 GHz 10 GHz 11 GHz 13 GHz 15 GHz 18 GHz 23 GHz 26 GHz 28 GHz 32 GHz 38 GHz 52 GHz
Name *
NWA- NWA- NWA- NWA- NWA- NWA- NWA- NWA- NWA- NWA- NWA- NWA- NWA- NWA-
009024( ) 009026( ) 009028( ) 009030( ) 009032( ) 009034( ) 009036( ) 009038( ) 009040( ) 009042( ) 009044( ) 009046( ) 009048( ) 009050( )
1 RF CKT H2202( ) H2203( ) H2204( ) H2225( ) H2205( ) H2227( ) H2228( ) H2229( ) H2230( ) H2231( ) H2232( ) H2233( ) H2234( ) H0416( )
2 IF CKT —
3 PS —
G
G
G G
Jack (IDU)
2-4
ROI-S05749 OPERATING EQUIPMENT
2.2 CTRL
NE CALL MMC
NMS PROTECT
LCT
PROTECT PASOLINK NEO
MAINT
MEMORY
IDU
LCT NMS NE AUX/ALM SC IN/OUT EOW CALL MMC
AUX/ALM MAINT(amber)
SC IN/OUT EOW
MEMORY(amber)
IDU(red)
The CTRL generates various control signals based upon LCT setup data
and gathered operating status in the IDU and from the ODU, has SC,
EOW, LAN, NE, EXT ALM, HK, Cluster ALM signals interface. By
Connecting a PC, manual control, performance monitoring and system
setup can be performed.
AUX/ALM (D-Sub
Female 44 pins)
Input/Output Signal
EOW: 1 CH
Frequency: 0.3 to 3.4 kHz (1020 Hz (Test Tone))
Level: −6 dBm
Impedance: 600 ohms
ALM: ALM 6 outputs/6 HK Inputs/ 4 HK Control outputs,
Cluster 4 Inputs/outputs
Output: Relay contact Form-C
Input: Photocoupler
Bz 1,2 IN: Signalling control extension input.
Call 1,2 OUT: Signalling control extension output.
EOW: EOW headphone jack
2-5
OPERATING EQUIPMENT ROI-S05749
SC IN/OUT (D-Sub
Female 44 pins)
Input/Output Signal
NE2: Network Element
Level: RS-485
DSC (RS-232C): 2 CH
Bit rate: 9600 bps
Level: RS-232C
DSC (V.11): 2 CH
Bit rate: 64 Kbps
Level: V.11
Impedance: 100 ohms
NE (RJ-45): Network Element
Level: 10 Base-T
LCT (USB): Serial interface USB-B type connector with PC
NMS (RJ-45): PNMS
Level: 10 Base-T
Indicators (CTRL)
MAINT Maintenance mode can be Actively blinks: In progress of program data download.
selected by LCT, PNMT and Inactively blinks:Protect Mode for CTRL replacement
PNMS into effect.
“The maintenance Mode
“ON” is selected”.
MEMORY Memory Card (MMC) status. ON: Enable access to Memory Card
OFF: Disable access to Memory Card
Blinks: Accessing Memory Card
IDU IDU Summary alarm. Check ALM LEDs on each module to find the cause
and/or connect LCT to check the performance condition.
2-6
ROI-S05749 OPERATING EQUIPMENT
Switch (CTRL)
Terminal Description
CTRL
ALM/AUX IN/OUT Service channel data input/output
(D-sub Female, 44 Pins)
Pins 1 (+) and 16 (–) EOW input 1
Pins 2 (+) and 17 (–) EOW output 1
Pins 3 (+) and 18 (–) EOW input 2
Pins 4 (+) and 19 (–) EOW output 2
Pin 5 Ground
Pins 25 (COM), 40 (NC) Maintenance alarm output
and 11 (NO) ⎯ RL1*1 Between Between
Pins 25 and 40 Pins 25 and 11
Normal state : Closed Open
Alarm state : Open Closed
Pins 24 (COM), 39 (NC) IDU CPU/PS1/PS2 alarm output
and 10 (NO) ⎯ RL2*1 Between Between
Pins 24 and 39 Pins 24 and 10
Normal state : Closed Open
Alarm state : Open Closed
Pins 23 (COM), 38 (NC) ODU1/ODU2 alarm output*2
and 9 (NO) ⎯ RL3 Between Between
Pins 23 and 38 Pins 23 and 9
Normal state : Closed Open
Alarm/Event state : Open Closed
2-7
OPERATING EQUIPMENT ROI-S05749
Terminal Description
2-8
ROI-S05749 OPERATING EQUIPMENT
Terminal Description
CTRL
SC IN/OUT NE2/DSC Service channel data input/output
(D-sub Female, 44 Pins)
Pins 1 (+) and 2 (–) NE2 TXD
Pin 3 Ground
Pins 4 (+) and 5 (–) V.11-1 data input
Pins 6 (+) and 7 (–) V.11-1 data output
Pins 8 (+) and 9 (–) V.11-2 data input
Pins 10 (+) and 11 (–) V.11-2 data output
Pins 12 and 13 (G) RS-232C-1 data input
Pins 14 and 15 (G) RS-232C-2 data input
Pin 16 NE2 RXD TERM
Pins 17, 18 Ground
Pins 19 (+) and 20 (–) V.11-1 clock input
Pins 21 (+) and 22 (–) V.11-1 clock output
Pins 23 (+) and 24 (–) V.11-2 clock input
Pins 25 (+) and 26 (–) V.11-2 clock output
Pins 27, 28, 29 Ground
Pins 30 (+) and 31 (–) NE2 RXD
Pin 32 Ground
Pins 33 (+) and 34 (–) V.11-1 frame pulse input
Pins 35 (+) and 36 (–) V.11-1 frame pulse output
Pins 37 (+) and 38 (–) V.11-2 frame pulse input
Pins 39 (+) and 40 (–) V.11-2 frame pulse output
Pins 41 and 42 (G) RS-232C-1 data output
Pins 43 and 44 (G) RS-232C-2 data output
2-9
OPERATING EQUIPMENT ROI-S05749
Terminal Description
2-10
ROI-S05749 OPERATING EQUIPMENT
EOW Connection
When EOW signal is connected between two IDUs, perform wiring as follows.
EOW 4W S 1 1 1
2 2 2
3 3 EOW 3
4 4 4W S 4
16 16 16
EOW 4W R
17 17 17
18 18 EOW EOW 18
19 19 4W R Extension 19
Buzzer IN 30 30 30
Call OUT 31 31 31
32 32 Buzzer IN 32
33 33 Call OUT 33
2-11
OPERATING EQUIPMENT ROI-S05749
2.3 MODEM
! IF IN/OUT
TX PWR PULL
RX ODU
XPIC MD/
XIF IN XIF OUT XPIC CTRL RESET CBL SELV PWR
XPIC CTRL
XIF OUT
PWR
XIF IN
Caution: Do not apply to the equipment a voltage that varies sharply. The equipment
may operate wrongly.
Caution: Do not remove/connect the IF cable with the IDU power ON, Turn the IDU
power OFF before connecting/disconnecting the IF cable, or equipment may
be damaged.
Caution: Do not insert/extract the MODEM with the power ON, turn the IDU power
OFF and remove all cables connected to the MODEM before insert/extract the
MODEM, or MODEM may be damaged.
Caution: The top surface of the IDU shelf above MODEM is hot in operation.
2-12
ROI-S05749 OPERATING EQUIPMENT
2-13
OPERATING EQUIPMENT ROI-S05749
Indicators (MODEM)
PWR The PWR switch of the MODEM is turned DC power is supplied to the
on. ODU also.
Transmit RF power of the ODU decreased Check Metering using LCT for
approx. −3 dB from preadjusted ATPC local and/or opposite site in
minimum (MIN) level in provisioning. Maintenance menu
Receiver input level of the ODU falls below
squelch level.
APC loop of local oscillator in ODU is
ODU
unlocked.
IF signal from the MODEM to ODU is lost.
Blinks when IF cable is open circuit.
Connected ODU is not matched with
inventory.
MD/CBL Blinks when IF cable is short circuit.
TX (only 1+1) Selected status of ODU TX When TX mute control: LED
Off
RX (only 1+1) Selected status of MODEM RX output signal When RX SWO switched to
opposite: LED Off
XPIC RESET XPIC function is OFF condition Only XPIC configuration.
Propagation condition
deteriorated or XPIC is reset
from LCT control.
Switches (MODEM)
PWR IDU and ODU power On/Off switch. Refer to Start-up and Shut-down the
Equipment in Maintenance Section
2-14
ROI-S05749 OPERATING EQUIPMENT
Terminal Description
SELV
SELV (DC IN) −48 V DC power input
(Molex M5569-04A1 Connector, Note: Only −48 V (−40.5 to −57 V) is available.
4 Pins)
Pins 1 and 3 Ground
Pins 2 and 4 −48 V
IF IN/OUT
TNC Jack (Female) * IF signal IN/OUT and PS OUT to the ODU
XPIC CTRL
(D-Sub Female, 15 pins) Used for interconnection between IDUs in XPIC
configuration.
Pins 1 (+) and 6 (–) XPIC SV TXD
Pins 2 (+) and 7 (–) XPIC SV RXD
Pin 3 Ground
Pins 4 (+) and 9 (–) XPIC SEL IN
Pins 5 (+) and 10 (–) XPIC SEL OUT
Pins 8 (+) and 12 (–) XPIC RESET IN
Pin 11 Ground
Pins 13 (–) and 14 (+) XPIC RESET OUT
Pin 15 Ground
2-15
OPERATING EQUIPMENT ROI-S05749
ALM
2M IN/OUT-A 2M IN/OUT-B 2M IN/OUT-C
Caution: Do not insert/extract the 48E1 INTFC with the power ON, turn the IDU power OFF
and remove all cables connected to the 48E1 INTFC before insert/extract the 48E1
INTFC, or 48E1 INTFC may be damaged.
Following I/O BOARD can be provided when the D-SUB 37 pins interface is required to the 2M IN/OUT INTFC
instead of MDR interface.
D-Sub 37 pins Connector
6 D-Sub Connectors are provided for 48E1.
User Interface
MDR 68 pins Connector
Note: One Unit space is necessary to install I/O BOARD above IDU.
The 48E1 INTFC applies for up to 48E1 (2.048 Mbps) signals interface.
The module performs, Bipolar-Unipolar/Unipolar-Bipolar conversion,
Stuffing/Destuffing, Multiplex/Demultiplex the radio section frame,
Hitless Switching, AIS Detection/Generation and Near End/Far End
loopback for each E1 CH. The interface impedance can be selected from
75 ohms/unbalanced and 120 ohms/balanced using LCT.
2-16
ROI-S05749 OPERATING EQUIPMENT
ALM Loss of output signal to DTE is detected. Perform Far End loopback test.
Error of channel usage. Signal is applied to unused channel.
Mounting module is not matched with Change LCT setting or other ( )INTFC
inventory. module.
2-17
OPERATING EQUIPMENT ROI-S05749
Terminal Description
48E1 INTFC
2M IN/OUT-A 2.048 Mbps HDB3 coded data signal input/output from/to
(CH 1 to CH 16) DTE
(MDR Connector, 68 pins) (CH 1 to CH 16), 75/120 ohms (selectable)
2-18
ROI-S05749 OPERATING EQUIPMENT
Terminal Description
2-19
OPERATING EQUIPMENT ROI-S05749
Terminal Description
48E1 INTFC
2M IN/OUT-B 2.048 Mbps HDB3 coded data input/output from/to DTE
(CH 17 to CH 32) (CH 17 to CH 32), 75/120 ohms (selectable)
(MDR Connector, 68 pins)
Note: Ground level is applied from DTE to (−) terminal
through interface cable when unbalanced impedance
is used.
Pins 1, 34, 35 and 68 Ground
Pins 33 (+) and 67 (−) CH17 data output
Pins 32 (+) and 66 (−) CH17 data input
Pins 31 (+) and 65 (−) CH18 data output
Pins 30 (+) and 64 (−) CH18 data input
Pins 29 (+) and 63 (−) CH19 data output
Pins 28 (+) and 62 (−) CH19 data input
Pins 27 (+) and 61 (−) CH20 data output
Pins 26 (+) and 60 (−) CH20 data input
Pins 25 (+) and 59 (−) CH21 data output
Pins 24 (+) and 58 (−) CH21 data input
Pins 23 (+) and 57 (−) CH22 data output
Pins 22 (+) and 56 (−) CH22 data input
Pins 21 (+) and 55 (−) CH23 data output
Pins 20 (+) and 54 (−) CH23 data input
Pins 19 (+) and 53 (−) CH24 data output
Pins 18 (+) and 52 (−) CH24 data input
Pins 17 (+) and 51 (−) CH25 data output
Pins 16 (+) and 50 (−) CH25 data input
Pins 15 (+) and 49 (−) CH26 data output
Pins 14 (+) and 48 (−) CH26 data input
Pins 13 (+) and 47 (−) CH27 data output
Pins 12 (+) and 46 (−) CH27 data input
2-20
ROI-S05749 OPERATING EQUIPMENT
Terminal Description
2-21
OPERATING EQUIPMENT ROI-S05749
Terminal Description
48E1 INTFC
2M IN/OUT-C 2.048 Mbps HDB3 coded data input/output from/to DTE
(CH 33 to CH 48) (CH 33 to CH 48), 75/120 ohms (selectable)
(MDR Connector, 68 pins)
Note: Ground level is applied from DTE to (−) terminal
through interface cable when unbalanced impedance
is used.
Pins 1, 34, 35 and 68 Ground
Pins 33 (+) and 67 (−) CH33 data output
Pins 32 (+) and 66 (−) CH33 data input
Pins 31 (+) and 65 (−) CH34 data output
Pins 30 (+) and 64 (−) CH34 data input
Pins 29 (+) and 63 (−) CH35 data output
Pins 28 (+) and 62 (−) CH35 data input
Pins 27 (+) and 61 (−) CH36 data output
Pins 26 (+) and 60 (−) CH36 data input
Pins 25 (+) and 59 (−) CH37 data output
Pins 24 (+) and 58 (−) CH37 data input
Pins 23 (+) and 57 (−) CH38 data output
Pins 22 (+) and 56 (−) CH38 data input
Pins 21 (+) and 55 (−) CH39 data output
Pins 20 (+) and 54 (−) CH39 data input
Pins 19 (+) and 53 (−) CH40 data output
Pins 18 (+) and 52 (−) CH40 data input
Pins 17 (+) and 51 (−) CH41 data output
Pins 16 (+) and 50 (−) CH41 data input
Pins 15 (+) and 49 (−) CH42 data output
Pins 14 (+) and 48 (−) CH42 data input
Pins 13 (+) and 47 (−) CH43 data output
Pins 12 (+) and 46 (−) CH43 data input
2-22
ROI-S05749 OPERATING EQUIPMENT
Terminal Description
2-23
OPERATING EQUIPMENT ROI-S05749
Terminal Description
8E1 INTFC
2M IN/OUT-A 2.048 Mbps HDB3 coded data input/output from/to DTE
(CH 1 to CH 8) (CH 1 to CH 8), 75/120 ohms (selectable)
(D-Sub Connector, 37 pins)
Note: Ground level is applied from DTE to (−) terminal
through interface cable when unbalanced impedance
is used.
Pins 5, 10, 15, 24 and 33 Ground
Pins 1 (+) and 2 (−) CH8 data input
Pins 3 (+) and 4 (−) CH7 data input
Pins 6 (+) and 7 (−) CH6 data input
Pins 8 (+) and 9 (−) CH5 data input
Pins 11 (+) and 12 (−) CH4 data input
Pins 13 (+) and 14 (−) CH3 data input
Pins 16 (+) and 17 (−) CH2 data input
Pins 18 (+) and 19 (−) CH1 data input
Pins 20 (+) and 21 (−) CH8 data output
Pins 22 (+) and 23 (−) CH7 data output
Pins 25 (+) and 26 (−) CH6 data output
Pins 27 (+) and 28 (−) CH5 data output
Pins 29 (+) and 30 (−) CH4 data output
Pins 31 (+) and 32 (−) CH3 data output
Pins 34 (+) and 35 (−) CH2 data output
Pins 36 (+) and 37 (−) CH1 data output
2-24
ROI-S05749 OPERATING EQUIPMENT
Terminal Description
8E1 INTFC
2M IN/OUT-B 2.048 Mbps HDB3 coded data input/output from/to DTE
(CH 9 to CH 16) (CH 9 to CH 16), 75/120 ohms (selectable)
(D-Sub Connector, 37 pins)
Note: Ground level is applied from DTE to (−) terminal
through interface cable when unbalanced impedance
is used.
Pins 5, 10, 15, 24 and 33 Ground
Pins 1 (+) and 2 (−) CH16 data input
Pins 3 (+) and 4 (−) CH15 data input
Pins 6 (+) and 7 (−) CH14 data input
Pins 8 (+) and 9 (−) CH13 data input
Pins 11 (+) and 12 (−) CH12 data input
Pins 13 (+) and 14 (−) CH11 data input
Pins 16 (+) and 17 (−) CH10 data input
Pins 18 (+) and 19 (−) CH9 data input
Pins 20 (+) and 21 (−) CH16 data output
Pins 22 (+) and 23 (−) CH15 data output
Pins 25 (+) and 26 (−) CH14 data output
Pins 27 (+) and 28 (−) CH13 data output
Pins 29 (+) and 30 (−) CH12 data output
Pins 31 (+) and 32 (−) CH11 data output
Pins 34 (+) and 35 (−) CH10 data output
Pins 36 (+) and 37 (−) CH9 data output
2-25
OPERATING EQUIPMENT ROI-S05749
Terminal Description
8E1 INTFC
2M IN/OUT-A 2.048 Mbps HDB3 coded data input/output from/to DTE
(CH 17 to CH 24) (CH 17 to CH 24), 75/120 ohms (selectable)
(D-Sub Connector, 37 pins)
Note: Ground level is applied from DTE to (−) terminal
through interface cable when unbalanced impedance
is used.
Pins 5, 10, 15, 24 and 33 Ground
Pins 1 (+) and 2 (−) CH24 data input
Pins 3 (+) and 4 (−) CH23 data input
Pins 6 (+) and 7 (−) CH22 data input
Pins 8 (+) and 9 (−) CH21 data input
Pins 11 (+) and 12 (−) CH20 data input
Pins 13 (+) and 14 (−) CH19 data input
Pins 16 (+) and 17 (−) CH18 data input
Pins 18 (+) and 19 (−) CH17 data input
Pins 20 (+) and 21 (−) CH24 data output
Pins 22 (+) and 23 (−) CH23 data output
Pins 25 (+) and 26 (−) CH22 data output
Pins 27 (+) and 28 (−) CH21 data output
Pins 29 (+) and 30 (−) CH20 data output
Pins 31 (+) and 32 (−) CH19 data output
Pins 34 (+) and 35 (−) CH18 data output
Pins 36 (+) and 37 (−) CH17 data output
2-26
ROI-S05749 OPERATING EQUIPMENT
Terminal Description
8E1 INTFC
2M IN/OUT-B 2.048 Mbps HDB3 coded data input/output from/to DTE
(CH 25 to CH 32) (CH 25 to CH 32), 75/120 ohms (selectable)
(D-Sub Connector, 37 pins)
Note: Ground level is applied from DTE to (−) terminal
through interface cable when unbalanced impedance
is used.
Pins 5, 10, 15, 24 and 33 Ground
Pins 1 (+) and 2 (−) CH32 data input
Pins 3 (+) and 4 (−) CH31 data input
Pins 6 (+) and 7 (−) CH30 data input
Pins 8 (+) and 9 (−) CH29 data input
Pins 11 (+) and 12 (−) CH28 data input
Pins 13 (+) and 14 (−) CH27 data input
Pins 16 (+) and 17 (−) CH26 data input
Pins 18 (+) and 19 (−) CH25 data input
Pins 20 (+) and 21 (−) CH32 data output
Pins 22 (+) and 23 (−) CH31 data output
Pins 25 (+) and 26 (−) CH30 data output
Pins 27 (+) and 28 (−) CH29 data output
Pins 29 (+) and 30 (−) CH28 data output
Pins 31 (+) and 32 (−) CH27 data output
Pins 34 (+) and 35 (−) CH26 data output
Pins 36 (+) and 37 (−) CH25 data output
2-27
OPERATING EQUIPMENT ROI-S05749
Terminal Description
8E1 INTFC
2M IN/OUT-A 2.048 Mbps HDB3 coded data input/output from/to DTE
(CH33 to CH 40) (CH 33 to CH 40), 75/120 ohms (selectable)
(D-Sub Connector, 37 pins)
Note: Ground level is applied from DTE to (−) terminal
through interface cable when unbalanced impedance
is used.
Pins 5, 10, 15, 24 and 33 Ground
Pins 1 (+) and 2 (−) CH40 data input
Pins 3 (+) and 4 (−) CH39 data input
Pins 6 (+) and 7 (−) CH38 data input
Pins 8 (+) and 9 (−) CH37 data input
Pins 11 (+) and 12 (−) CH36 data input
Pins 13 (+) and 14 (−) CH35 data input
Pins 16 (+) and 17 (−) CH34 data input
Pins 18 (+) and 19 (−) CH33 data input
Pins 20 (+) and 21 (−) CH40 data output
Pins 22 (+) and 23 (−) CH39 data output
Pins 25 (+) and 26 (−) CH38 data output
Pins 27 (+) and 28 (−) CH37 data output
Pins 29 (+) and 30 (−) CH36 data output
Pins 31 (+) and 32 (−) CH35 data output
Pins 34 (+) and 35 (−) CH34 data output
Pins 36 (+) and 37 (−) CH33 data output
2-28
ROI-S05749 OPERATING EQUIPMENT
Terminal Description
8E1 INTFC
2M IN/OUT-B 2.048 Mbps HDB3 coded data input/output from/to DTE
(CH41 to CH 48) (CH 41 to CH 48), 75/120 ohms (selectable)
(D-Sub Connector, 37 pins)
Note: Ground level is applied from DTE to (−) terminal
through interface cable when unbalanced impedance
is used.
Pins 5, 10, 15, 24 and 33 Ground
Pins 1 (+) and 2 (−) CH48 data input
Pins 3 (+) and 4 (−) CH47 data input
Pins 6 (+) and 7 (−) CH46 data input
Pins 8 (+) and 9 (−) CH45 data input
Pins 11 (+) and 12 (−) CH44 data input
Pins 13 (+) and 14 (−) CH43 data input
Pins 16 (+) and 17 (−) CH42 data input
Pins 18 (+) and 19 (−) CH41 data input
Pins 20 (+) and 21 (−) CH48 data output
Pins 22 (+) and 23 (−) CH47 data output
Pins 25 (+) and 26 (−) CH46 data output
Pins 27 (+) and 28 (−) CH45 data output
Pins 29 (+) and 30 (−) CH44 data output
Pins 31 (+) and 32 (−) CH43 data output
Pins 34 (+) and 35 (−) CH42 data output
Pins 36 (+) and 37 (−) CH41 data output
2-29
OPERATING EQUIPMENT ROI-S05749
ALM
2M IN/OUT-A 2M IN/OUT-B
100M PORT 1 PORT 2 100M
100M(green)
COLLISION/DUPLEX(amber)
LINK(green)
Caution: Do not insert/extract the 16E1 INTFC with the power ON, turn the IDU power OFF
and remove all cables connected to the 16E1 INTFC before insert/extract the 16E1
INTFC, or 16E1 INTFC may be damaged.
Following I/O BOARD can be provided when the BNC 16E1 interface is required to the 2M IN/OUT INTFC instead
of D-Sub 37 pins.
CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8
2M IN/OUT-B
CH9 CH10 CH11 CH12 CH13 CH14 CH15 CH16 CH9 CH10 CH11 CH12 CH13 CH14 CH15 CH16
Note: One Unit space is necessary to install I/O BOARD above or below IDU and 2 D-Sub/D-
Sub cables also.
The 16E1 INTFC applies for up to 16E1 (2.048 Mbps) signals interface.
The module performs, Bipolar-Unipolar/Unipolar-Bipolar conversion,
Stuffing/Destuffing, Multiplex/Demultiplex the radio section frame,
Hitless Switching, AIS Detection/Generation and Near End/Far End
loopback for each E1 CH. The interface impedance can be selected from
75 ohms/unbalanced and 120 ohms/balanced using LCT.
2-30
ROI-S05749 OPERATING EQUIPMENT
ALM Loss of output signal to DTE is detected. Perform Far End loopback test.
Error of channel usage. Signal is applied to unused channel.
Mounting module is not matched with Change LCT setting or other ( )INTFC
inventory. module.
LAN link failure occurs. (e/w LAN Check LAN cable connection.
PORT)
100M LAN signal is in 100BASE-TX mode.
LINK LAN and associated equipment are linked
and flashing under the exchanging the
packet.
COLLISION/ Input/Output LAN signal is in Full
DUPLEX Duplex mode. Flashing when a collision
condition occurs.
2-31
OPERATING EQUIPMENT ROI-S05749
Terminal Description
16E1 INTFC
2M IN/OUT-A 2.048 Mbps HDB3 coded data input/output from/to DTE
(CH 1 to CH 8) (CH 1 to CH 8), 75/120 ohms (selectable)
(D-Sub Connector, 37 pins)
(I/O BOARD IDU INTFC) Note: Ground level is applied from DTE to (−) terminal
through interface cable when unbalanced impedance
is used.
Pins 5, 10, 15, 24 and 33 Ground
Pins 1 (+) and 2 (−) CH8 data input
Pins 3 (+) and 4 (−) CH7 data input
Pins 6 (+) and 7 (−) CH6 data input
Pins 8 (+) and 9 (−) CH5 data input
Pins 11 (+) and 12 (−) CH4 data input
Pins 13 (+) and 14 (−) CH3 data input
Pins 16 (+) and 17 (−) CH2 data input
Pins 18 (+) and 19 (−) CH1 data input
Pins 20 (+) and 21 (−) CH8 data output
Pins 22 (+) and 23 (−) CH7 data output
Pins 25 (+) and 26 (−) CH6 data output
Pins 27 (+) and 28 (−) CH5 data output
Pins 29 (+) and 30 (−) CH4 data output
Pins 31 (+) and 32 (−) CH3 data output
Pins 34 (+) and 35 (−) CH2 data output
Pins 36 (+) and 37 (−) CH1 data output
2-32
ROI-S05749 OPERATING EQUIPMENT
Terminal Description
16E1 INTFC
2M IN/OUT-B 2.048 Mbps HDB3 coded data input/output from/to DTE
(CH 9 to CH 16) (CH 9 to CH 16), 75/120 ohms (selectable)
(D-Sub Connector, 37 pins)
(I/O BOARD IDU INTFC) Note: Ground level is applied from DTE to (−) terminal
through interface cable when unbalanced impedance
is used.
Pins 5, 10, 15, 24 and 33 Ground
Pins 1 (+) and 2 (−) CH16 data input
Pins 3 (+) and 4 (−) CH15 data input
Pins 6 (+) and 7 (−) CH14 data input
Pins 8 (+) and 9 (−) CH13 data input
Pins 11 (+) and 12 (−) CH12 data input
Pins 13 (+) and 14 (−) CH11 data input
Pins 16 (+) and 17 (−) CH10 data input
Pins 18 (+) and 19 (−) CH9 data input
Pins 20 (+) and 21 (−) CH16 data output
Pins 22 (+) and 23 (−) CH15 data output
Pins 25 (+) and 26 (−) CH14 data output
Pins 27 (+) and 28 (−) CH13 data output
Pins 29 (+) and 30 (−) CH12 data output
Pins 31 (+) and 32 (−) CH11 data output
Pins 34 (+) and 35 (−) CH 10 data output
Pins 36 (+) and 37 (−) CH 9 data output
2-33
OPERATING EQUIPMENT ROI-S05749
Terminal Description
2-34
ROI-S05749 OPERATING EQUIPMENT
ALM
STM-1 IN STM-1 OUT
ALM
STM-1 OUT STM-1 IN ONLINE
ALM (red)
ONLINE(green)
Caution: Do not insert/extract the STM-1 INTFC with the power ON, turn OFF the PWR
switch on the MODEM and remove all cables connected to the STM-1 INTFC before
insert/extract the STM-1 INTFC, or STM-1 INTFC may be damaged.
The STM-1 INTFC provides STM-1 signal interface with two types, one is
electrical and the other is optical. The module performs,
2-35
OPERATING EQUIPMENT ROI-S05749
2-36
ROI-S05749 OPERATING EQUIPMENT
2-37
OPERATING EQUIPMENT ROI-S05749
2.7 E3 INTFC
E3 CH1 E3 CH2
ALM
IN OUT IN OUT WS IN/OUT 100M PORT 1 PORT 2 100M
100M(green)
COLLISION/DUPLEX(amber)
LINK(green)
Caution: Do not insert/extract the E3 INTFC with the power ON, turn the IDU power OFF and
remove all cables connected to the E3 INTFC before insert/extract the E3 INTFC, or
E3 INTFC may be damaged.
The E3 INTFC applies for up to two (2) E3 (34.368 Mbps) signals, four (4)
or eight (8) WS (2.048 Mbps) signals and two (2) port LAN (10/
100BASE-T(x)) signals interface. The module performs, Bipolar-
Unipolar/Unipolar-Bipolar conversion, Stuffing/Destuffing, Multiplex/
Demultiplex the radio section frame, Hitless Switching and AIS Detection/
Generation for each E3 and WS (E1) signal. The interface impedance of
the WS can be selected from 75 ohms/unbalanced and 120 ohms/balanced
using LCT.
2-38
ROI-S05749 OPERATING EQUIPMENT
ALM Loss of output signal to DTE is detected. Perform Far End loopback test.
Mounting module is not matched with Change LCT setting or other ( )INTFC
inventory. module.
LAN link failure occurs. (e/w LAN Check LAN cable connection.
PORT)
100M LAN signal is in 100BASE-TX mode.
LINK LAN and associated equipment are linked
and flashing under the exchanging the
packet.
COLLISION/ Input/Output LAN signal is in Full
DUPLEX Duplex mode. Flashing when a collision
condition occurs.
2-39
OPERATING EQUIPMENT ROI-S05749
Terminal Description
WS INTFC
WS IN/OUT 2.048 Mbps HDB3 coded data input/output from/to DTE
(CH 1 to CH 8) (CH 1 to CH 8), 75/120 ohms (selectable)
(D-Sub Connector, 37 pins)
Note: Ground level is applied from DTE to (−) terminal
through interface cable when unbalanced impedance
is used.
Pins 5, 10, 15, 24 and 33 Ground
Pins 1 (+) and 2 (−) CH8 data input
Pins 3 (+) and 4 (−) CH7 data input
Pins 6 (+) and 7 (−) CH6 data input
Pins 8 (+) and 9 (−) CH5 data input
Pins 11 (+) and 12 (−) CH4 data input
Pins 13 (+) and 14 (−) CH3 data input
Pins 16 (+) and 17 (−) CH2 data input
Pins 18 (+) and 19 (−) CH1 data input
Pins 20 (+) and 21 (−) CH8 data output
Pins 22 (+) and 23 (−) CH7 data output
Pins 25 (+) and 26 (−) CH6 data output
Pins 27 (+) and 28 (−) CH5 data output
Pins 29 (+) and 30 (−) CH4 data output
Pins 31 (+) and 32 (−) CH3 data output
Pins 34 (+) and 35 (−) CH2 data output
Pins 36 (+) and 37 (−) CH1 data output
2-40
ROI-S05749 OPERATING EQUIPMENT
Terminal Description
2-41
OPERATING EQUIPMENT ROI-S05749
DC-DC CONV
− 43V + PULL
PWR
G
OUT ALM PWR
STD FUSE (250V/8AH) SELV
Note: If the PWR LED is not lit though the PWR switch has set to ON, set the PWR switch to
OFF, remove two fuses from the module and check the conduction of them.
Caution: Do not apply to the equipment a voltage that varies sharply. The equipment may
operate wrongly.
Caution: Do not remove/connect the power supply cable with the PWR switch ON, Turn the
PWR switch OFF before connecting/disconnecting the power supply cable IN or
OUT, if not, module may be damaged.
SELV
2-42
ROI-S05749 OPERATING EQUIPMENT
PWR IDU and ODU power on/off switch. Refer to Start-up and Shut-down the
Equipment in Maintenance Section
Terminal Description
SELV
SELV (DC IN) −20 to −60/20 to 60 V DC power input
(Molex M5569-04A1 Connector,
4 Pins)
Pins 1 and 3 0 V /(or +20 to +60 V)
Pins 2 and 4 −20 to −60 V/(or 0 V)
−43V OUT
(Molex M5569-02A1, −43 V DC power output (connects to the SELV connector of
2 pins) (DC OUT) the MODEM module using accessory cable)
Pin 1 Ground
Pin 2 −43 V
ALM Power supply ALM signal output
(D-Sub Female, 9 pins)
Pins 6 (COM), 1 (NC) and PS and input voltage alarm output
2 (NO) Between Between
Pins 1 and 6 Pins 6 and 2
Normal state : Closed Open
Alarm state : Open Closed
Pin 9 Ground
Pins3,4,5,7,8 No connected
2-43
OPERATING EQUIPMENT ROI-S05749
2.9 ODU
RF IN/OUT
RX LEV
MON IFL FG
RF IN/OUT
(REAR VIEW)
Coaxial Cable Type (6/7/8 GHz)
The ODU receives 340 MHz IF signal from the IDU and converts it to an
RF signal using a local signal generated by a synthesized local oscillator.
This RF signal is then sent to the antenna through the BPF which limits the
RF transmit signal dispersion. The TX output level is controlled to the
specified from the IDU corresponded to the QPSK/16QAM/32QAM or
128QAM modulation.
The RF signal received from the antenna is amplified to the required level.
Afterward the signal is converted into the 140 MHz IF signal by mixing
with a local signal generated by a synthesized local oscillator. Then the
140 MHz IF signal is sent to the IDU through the IF cable.
2-44
ROI-S05749 OPERATING EQUIPMENT
IFL (N Female)
TX Frequency 340 MHz
RX Frequency: 140 MHz
Power supply: −48 V
Impedance: 50 ohms
Connecting IF Cable length:
5D-FB: less than 150 m
8D-FB: less than 300 m
10D-FB: less than 350 m
FG (Screw) Frame ground, connecting near by ground point.
RF IN/OUT RF signal interface.
- N female connector for the 6/7/8 GHz ODU with coaxial
cable connection.
- NEC proprietary flange for the 10 to 52 GHz ODU with
antenna mounting (direct/OMT/HYB COMB/TX ATT).
- Waveguide connection flange;
6 GHz: PDR70
7/8 GHz: PDR84
10/11 GHz: PDR100
13 GHz: PBR120
15 GHz: PBR140
18/23 GHz: PBR220
26 GHz: PBR260
28/32/38 GHz:PBR320
RX LEV MON: Monitoring RX LEV in AGC voltage Use LCT to check the RX LEV in
using the digital voltmeter or PASOLINK Maintenance.
MONITOR unit * for antenna
orientation.
2-45
OPERATING EQUIPMENT ROI-S05749
2-46
46 pages
ROI-S05749 SYSTEM SETUP
3. SYSTEM SETUP
This section provides system setup to make up proper system
configuration. The setup is performed accessing to the LCT program using
the PC. For the detail procedure, refer to Section IV Appendix LCT
Operation Manual.
The setup of the equipment performs upon PDH system or SDH system as
listed in the following table.
3-1
SYSTEM SETUP ROI-S05749
3-2
ROI-S05749 SYSTEM SETUP
3-3
SYSTEM SETUP ROI-S05749
The setup of the provisioning performs upon PDH system or SDH system
as items listed in the following table.
3-4
ROI-S05749 SYSTEM SETUP
3-5
SYSTEM SETUP ROI-S05749
3-6
ROI-S05749 SYSTEM SETUP
3-7
SYSTEM SETUP ROI-S05749
The alarm and status condition based upon equipment setup and
provisioning setup, therefore indication items vary depending on the those
setup.
ODU
TX Power
TX Input
RX Level
APC
ODU CPU/Cable Open
Mute Status
LO REF
TX SW Status : only 1+1 configuration
RX SW Status : only 1+1 configuration
MODEM
Unequipped
Module
LOF
Frame ID
High BER
Low BER
Early Warning
MOD
DEM
Input Voltage
Power Supply : only 1+1 configuration
IF Cable Short
Linearizer Status
Linearizer Fail
Cable EQL
ATPC Power Mode
CTRL
CTRL Module
MMC
APS SW Fail
APS Online Status
3-8
ROI-S05749 SYSTEM SETUP
3-9
SYSTEM SETUP ROI-S05749
Note:(*1) The items of RMON(History) and RMON(Current) are displayed the same.
3-10
ROI-S05749 SYSTEM SETUP
ODU
ODU
TX Power
TX Input
RX Level
APC
ODU CPU
Mute Status
LO REF
TX SW Status : only 1+1 configuration
RX SW Status : only 1+1 configuration
IDU
IDU
IDU CPU
MODEM
MODEM
MODEM Unequipped
LOF
Route ID
High BER
Low BER
Early Warning
MOD
DEM
Input Voltage
Power Supply : only 1+1 configuration
IF Cable Short
Linearizer Status
Linearizer Fail
Cable EQL
XIF
XCTRL : only XPIC configuration
XPIC Status
XREF
ATPC Power Mode
CTRL
CTRL Module
MMC Mount
UAE
STM-1(1)/UAE(DMR)
STM-1(1)/UAE(MUX)
3-11
SYSTEM SETUP ROI-S05749
TCN-RX LEV
TCN-RX LEV-15min
TCN-RX LEV-1day
3-12
ROI-S05749 SYSTEM SETUP
3-13
SYSTEM SETUP ROI-S05749
3.4 Control
The control items that are displayed on the LCT PC are listed in the
following table. the control operation can be performed in Maintenance
“ON”.
3-14
ROI-S05749 SYSTEM SETUP
3-15
SYSTEM SETUP ROI-S05749
3.5.1 Automatic Laser Shutdown Control (only for SDH OPT INTFC)
(SDH)
The STM-1 INTFC (only for OPT) is provided with the Automatic Laser
Shutdown (ALS) function that can be enabled or disabled. If the ALS
function is enabled, the laser output is periodically turned ON and OFF
when the optical cable carrying the STM-1 signal is disconnected
inadvertently, or intentionally during maintenance. When the ALS
function is disabled, the laser output is always ON even if the optical cable
is disconnected. Fig. 3-1 shows a block diagram of the ALS function.
If a fault occurs at point A and the absence of the optical input signal in the
RX 2 lasts for 550 ±50 msec (STM-1 LOS alarm condition), the optical
signal bound for the RX 1 (MUX equipment) from the TX 2 (OPT INTFC
module) is interrupted by a control signal generated inside the OPT INTFC
module. The MUX equipment detects the loss of signal at RX1 and the
ALS function in the MUX will, subsequently, turn off the laser output of
TX1. When the fault at point A is cleared the system can be restored by
controlling the laser output of TX2 through one of the following modes:
• Automatic control
3-16
ROI-S05749 SYSTEM SETUP
MUX
EQUIPMENT CTRL
OPT INTFC
RX2
A
TX1 O/E
RLOS 550 ± 50 ms CLEAR
90±10S 2±0.25S 2S
TIMER TX ON
TX ON TX ON
TIMER TIMER TIMER
ALS CONT
TX2 ENABLE/DISABLE
60/180/
CONT
300 sec.
DELAY
RX1 O/E
SB/DATA
DATA BUS
BUS
LCT or PNMT
3-17
SYSTEM SETUP ROI-S05749
SW
Protection OPT IN
OPT OUT STM-1 (OPT)
INTFC MODEM
LOS/LOF/BER
DET
Module Failure
The STM-1 (OPT) INTFC monitors the OPT line input signal
interface condition and when an alarm condition occurs in the optical
cable or optical interface module, APS is activated. Also the APS is
activated when remote control signal is received.
Uni-directional APS is performed only in the receiving section of the
local side when a failure or signal degradation of the received signal
is detected in one direction. Fig. 3-3 shows APS switching mode.
3-18
ROI-S05749 SYSTEM SETUP
SW CTRL
ASSOCIATED EQUIPMENT
PASOLINK NEO
Received OPT failure
WORKING
(Working) WORKING STM-1 (OPT) INTFC
(1) (No.1)
PROTECTION
(Protection) STM-1 (OPT) INTFC
PROTECTION (No.2)
WORKING
(Working) STM-1 (OPT) INTFC
WORKING (No.1)
(2)
PROTECTION STM-1 (OPT) INTFC
(Protection) (No.2)
PROTECTION
SW CTRL
WORKING
(Working) WORKING STM-1 (OPT) INTFC
(1) (No.1)
PROTECTION
(Protection) STM-1 (OPT) INTFC
PROTECTION (No.2)
WORKING
(Working) STM-1 (OPT) INTFC
WORKING (No.1)
(2)
PROTECTION STM-1 (OPT) INTFC
(Protection) (No.2)
PROTECTION
Note: ON LINE
OFF LINE
3-19
SYSTEM SETUP ROI-S05749
• UNEQUIP > LKI*1 > FSW > SF > SD*2 > MSW
• UNEQUIP > LKI*1 > SF(P) > FSW > SF(W) > SD*2 > MSW
3-20
ROI-S05749 SYSTEM SETUP
LCT MENU
---Condition for APS--- Range
Alarm/Status
APS Maintenance Mode Manual Forced
Equipment Setup
APS Condition-SF(PROT) Priority High Priority Low
Inventory
AUX I/O APS Condition-SD(B1) Included SD Excluded SD
Maintenance Lock in Usage Not Used Used
Provisioning Lock in Detect Count [times] 4 1 to 255
BER Threshold Setting Lock in Detect Time [min] 10 1 to 60
SC Assignment Lock in Hold Time [hours]) 24 1 to 48
STM-1 Setting
TX Power Control
Condition for TX/RX SW
Condition for APS
Relay Setting
TCN Threshold (15min)
TCN Threshold (1day)
PMON Select
Others
Metering
PMON(Current)
PMON(History)
• APS Condition-SF(PROT):
This is a setup to give higher priority to switchover by SF in
Protection side.
Priority High: This setup gives highly priority to SF of Protection
side (installed in INTFC Slot2) for switchover
control condition. Since the setup gives priority
higher than the Forced Control, the ONLINE is
maintained in Working side (installed in INTFC
Slot1) under occurrence of SF condition of
Protection side.
3-21
SYSTEM SETUP ROI-S05749
• APS Condition-SD(B1)
This is a setup that it includes the SD or excludes SD for the
switchover control condition. When including it, the switchover is
performed when SD reaches the threshold value which is set in BER
Threshold/SD (MUX) in provisioning.
Include SD: Including SD for switchover condition
Exclude SD: Excluding SD for switchover condition
• Lock in
The function is used to pause the switchover activation for a period of
time when in the switchover of frequent occurrence.
The following setting is needed to be used for it.
Lock in Count: Setup for the Lock in threshold value of the
switchover number of times.
(setting range: 1 to 255 times)
Lock in Detect time: Setup for the watching interval of counting
number of times for Lock in.
(setting range: 1 to 60 minutes)
Lock in Hold time: Setup for the duration of pause of switchover
in the Lock in condition.
(setting range: 1 to 48 hours)
The Lock in condition may be released after passing the Lock in Hold
time or the change of setting.
The following is an example in default value.
• Lock in Count: 4
• Lock in Detect time: 10
• Lock in Hold time: 24
This sets into the Lock in condition when the switchover is activated
more than 4 times within 10 minutes interval of watching number of
times. The switchover activation pauses during 24 hours after set in
the Lock in condition. The Lock in condition will be released after
passing of 48 hours and it sets into normal mode.
3-22
ROI-S05749 SYSTEM SETUP
3-23
SYSTEM SETUP ROI-S05749
MODEM TX RX MODEM
REMOTE REMOTE
CTRL CTRL
MODEM RX TX MODEM
-50 dBm
5 dB
RX LEVEL
(ATPC
HYSTERESIS)
-55 dBm
(RX THRESHOLD
LEVEL)
3-24
ROI-S05749 SYSTEM SETUP
Using MTPC-ATPC
Even if the station is set in the MTPC mode, the opposite station is likely
to be set in the ATPC mode. Therefore, setting the RX Threshold (ATPC
Threshold level) is required for controlling the transmission level of the
opposite station. Between the stations that are respectively set in the
MTPC mode, however, the setting is disabled.
STATION A STATION B
PASOLINK PASOLINK
ODU ODU
MTPC ATPC
(RX Threshold: −50 dBm)
3-25
SYSTEM SETUP ROI-S05749
(MTPC)
MASTER
(ATPC) STATION (ATPC)
SUBSTATION 1 (B) SUBSTATION 2
(A)
(C)
(ATPC)
SUBSTATION 5
(ATPC)
SUBSTATION 3
(ATPC)
SUBSTATION 4
(A),(B) : Diffraction to other route.
(C) : RX received level down.
3-26
ROI-S05749 SYSTEM SETUP
The loopback function is provided for checking the system quality during
maintenance and/or to quickly isolate a fault location on the PDH and
SDH configuration. The control is performed by the LCT, the PNMT or
the PNMS.
STM-1/E1/E3 STM-1/E1/E3
DATA CODE CODE DATA
MUX MOD TX RX DEM DEMUX
IN CONV CONV OUT
STM-1/E1/E3
DATA CODE CODE STM-1/E1/E3
DEMUX DEM RX TX MOD MUX CONV
OUT CONV DATA
IN
( )INTFC MODEM MODEM ( )INTFC
CTRL
3-27
SYSTEM SETUP ROI-S05749
Link Loss Forwarding control provides two kinds of functions for 10/
100BASE-T interface. One is to automatically stop the output from the
LAN port to alert the equipment connected with the LAN port when the
system has been disconnected by the fault in the radio section. The other is
to transmit the information for cutting the link interconnected with the
LAN port in the opposite station when the link between the LAN port and
equipment is faulty. This function can be selected by setting
“Provisioning” on LCT to “Enable” or “Disable”.
Radio Fault
FAULT
HUB LAN LAN HUB
PASOLINK NEO
DATA DATA
IN OUT
MUX PASOLINK PASOLINK MUX
RADIO SECTION
3-28
ROI-S05749 SYSTEM SETUP
STATION A STATION B
PASOLINK NEO PASOLINK NEO
MODEM MODEM
STM-1 STM-1 RFCOH RFCOH STM-1 STM-1
INPUT INTFC ODU ODU FSYNC INTFC OUTPUT
MUX DEMUX
INPUT
LOSS LOF STM-1
LOF
LOS
LOF RFCOH
Station A Station B
LCT
Event STM-1
LED LCT LED STM-1 Output OUTPUT
Control
STM-1 Input Loss at MAIN INTFC Shutdown *
IDU ALM ⎯ Under Execution
Station A LOS (or all “1”)
STM-1 Loss of MAIN INTFC Shutdown *
IDU ALM ⎯ Under Execution
Frame at Station A LOF (or all “1”)
Shutdown *
RX Level Down ⎯ N/A ODU ALM Under Execution
(or all “1”)
Loss of Radio Shutdown *
⎯ N/A IDU ALM Under Execution
Frame at Station B (or all “1”)
BER Degrade
⎯ N/A IDU ALM Normal N/A
(≤1E-4) at Station B
3-29
SYSTEM SETUP ROI-S05749
V-pol V-pol
IDU ODU ODU IDU
Local/Remote XPIC
V/H reset V-pol
OMT OMT REMOTE
Local/Remote XPIC
reset H-pol
• The XPIC RESET control is applied from the DEM module in the X-
pol. channel.
3-30
ROI-S05749 SYSTEM SETUP
PASOLINK PASOLINK
NEO NEO
PNMS PNMT
3-31
SYSTEM SETUP ROI-S05749
When both the No. 1 and No. 2 channels are in normal operating
condition, the STM-1/E1/E3 data streams from the associated MUX
equipment are sent to the receiving end through the No. 1 and No. 2
channels. At the receiving end, the output data streams of the No. 1 and
No. 2 channels MODEM enter the HL SW. The data signal selected by
HL SW is fed to associated MUX equipment.
At the receiving end, when the low bit error alarm (LOW BER ALM) is
detected in the MODEM of the No. 1 channel, the alarm signal is sent to
the switch control logic circuit on the CTRL module. The switch control
logic circuit send the HL SW control signal to the ( ) INTFC module.
Then, the HL SW selects the data signal from No.2 channel. The
switching condition is shown on the RX1 and RX2 STATUS indicators on
the IDU.
When both the No. 1 and No. 2 channels are in normal operating
condition, the STM-1/E1/E3 data signal from the associated MUX
equipment are sent to the No. 1 and No. 2 channel ODUs through the No. 1
and No. 2 channel IDUs. Here, either of the No. 1 or No. 2 channel signal
is selected at the TX switch on the ODU and fed to the receiving end. At
the receiving end, the output data signal of the No. 1 and No. 2 channels
MODEM enter the HL SW on the ( ) INTFC module. The data signal
selected by HL SW is fed to associated MUX equipment.
3-32
ROI-S05749 SYSTEM SETUP
At the receiving end, when the low bit error alarm (LOW BER ALM) is
detected in the MODEM of the No. 1 channel, the alarm signal is sent to
the switch control logic circuit on the CTRL module. The switch control
logic circuit send the HL SW control signal to the ( )INTFC module. Then,
the HL SW selects the data signal from No.2 channel. The switching
condition is shown on the RX1 and RX2 STATUS indicators on the IDU.
The following explains the protection switching function in the 1+1 Twin-
path and HS system.
(a) TX Switching
TX switching in HS system is accomplished by muting the TX
output power of either No.1 or No.2 channel ODU. Two mode of
TX switch controls are provided: automatic switching that is
initiated by detection of a failure in the transmit section of the IDU
or ODU, and manual switching is performed by using the LCT.
TX switching, either manually or automatically, may cause a
momentary interruption of the traffic. TX switching have the
following operational mode:
• Switching Mode:
• Switching Priority:
3-33
SYSTEM SETUP ROI-S05749
(b) RX Switch
RX switching in 1+1 Twin-path/HS system is performed by the HL
SW on the ( ) INTFC module.
Two types of RX switch controls are provided: automatic
switching that is initiated by the quality deterioration of the
received signal and manual switching that is initiated by the
operator using the LCT.
The switching mode and switching priority for automatic and
manual switching are identical to those of TX switching. However,
the switching priority is only valid under automatic switching
control. This is because automatic switching is implemented by
hardware logic and manual switching is implemented by software
logic. That is, automatic switching and manual switching are
completely independent and separate operations. Thus, when the
operator reverts to automatic switching after performing manual
switching, the channel will be re-selected by the switch control
logic circuit.
• Switching Mode:
• Switching Priority:
• RX SW Maintenance Mode:
3-34
ROI-S05749 SYSTEM SETUP
• RX SW Condition-Early Warning
3-35
SYSTEM SETUP ROI-S05749
3-36
36 pages