Amine Unit Start Up

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 11

Amine-unit startup illustrates commissioning

considerations

Effective startups usually stem from efficient scheduling and attention to detail during project design
and commissioning. While commissioning of typical amine units can be straightforward, a disconnect
often may exist between design and real-world operating conditions. The earlier this disconnect is
discovered, the easier startup becomes.
In 2015 an Indian refiner commissioned an amine methyldiethanolamine (MDEA) unit to remove acid
gas (carbon dioxide, CO2) from low-pressure gas feedstock as part of a broader refinery expansion
project.
During and following initial startup, the unit experienced a series of operational issues. While the
MDEA unit has since achieved optimal and consistent operations, the troubleshooting process
highlighted important considerations applicable to design and startup-commissioning of acid-gas
removal systems.
This article uses the authors' amine-treating experience at the Indian refinery and from previous
assignments to outline a detailed approach to identifying and troubleshooting sources of common
operational issues with monoethanolamine (MEA) and MDEA-based amine units. It also presents
relevant unit design and precommissioning techniques that can be employed to streamline startup.
Technology selection
CO2 absorption by amine solutions is a reversible process, the equilibrium of which depends on
factors such as the temperature, concentration, and circulation rate of the amine solution, as well as
the partial pressure of CO2 in feed gas.
The gas treatment industry uses, among others, the alkanolamine solutions MEA and MDEA to
absorb CO2 and hydrogen sulfide (H2S) from acid gas. MEA is a primary amine because only a single
carbon atom bonds to the nitrogen atom (i.e., only one hydrogen atom in the ammonia molecule is
replaced). Because they have a higher heat of reaction and are more alkaline, MEA solutions tend to
be more reactive and require more stripping steam than MDEA solutions.
With MDEA, a tertiary amine, all hydrogen atoms in the ammonia molecule are replaced by carbon.
These tertiary solutions are more sterically hindered, resulting in lower reactivity, lower alkalinity, and
slower reactions. MDEA solutions also are virtually noncorrosive. MDEA, however, must be
combined with a special vendor-provided activator to enhance its reaction kinetics with the acid gas
targeted for removal.
The accompanying table compares advantages and disadvantages of using MEA and MDEA in gas
treatment applications.
The reaction of CO2 with primary MEA doesn't stop with formation of one stable product in the rich
amine. Acid-loaded MEA solutions react further to form diamines and other byproducts such as
carboxylic acids. Over time, these byproducts make amine solutions even more corrosive and result
in hydrogen-assisted stress corrosion cracking (SCC) on vessels and piping at welds, requiring the
MEA unit to operate at limited amine concentrations as a form of mitigation (Box 1).
The Indian refiner selected MDEA to remove CO2 from its low-pressure gas feedstock for the
following reasons:
• MDEA's ability to operate at a higher concentration and higher values of acid gas (CO 2) mole/mole
of amine loadings-i.e., pure amine, not the solution-enabled a 39% lower flowrate of MDEA solution
vs. MEA solution based on the amine unit's design.
• Due to its tertiary nature, MDEA's heat of solution with CO2 in the absorber tower was lower (575
btu/lb) than MEA's (825 btu/lb), allowing for lower steam requirements in the stripping section. 1
• MDEA's slow reactivity could be addressed by adding piperazine, an activator, to enhance MDEA-
CO2 reaction kinetics.
• Feed-gas pressure to the absorber was designed to 2 barg, whereas MEA solutions tend to have
high vapor pressures that can lead to major vaporization losses, especially in low-pressure
operations.
• MDEA is relatively noncorrosive.
Unit overview
The refinery's amine plant design centered around performance of the absorber tower, which like
most in the industry, has a bottom and top section. In the bottom section, feed gas to the unit is
counter scrubbed with lean-amine solution before moving to the top section where, past the chimney
tray, the gas is washed with demineralized water to remove any entrained amine solution and, if
necessary, reduce its temperature. To ensure the unit could meet its design capacity for acid gas
removal, packing was used throughout the absorber based on its superior turndown capability vs.
trays, as well as its tendency for more flow capacity and lower pressure drops than trays in towers
with a similar diameter and similar CO2-scrubbing efficiency.
From a design perspective, proper vapor-liquid distribution is critical if packing is used throughout an
absorber. Unlike trays, packing does not redistribute either vapor or liquid, which can lead to
channeling and poor contacting efficiency between the two phases. To avoid these problems, a
channel-type gravity lean-amine solution distributor (e.g., a multi-through distributor with slotted
tubes) is preferable to spray nozzles, which often require a pressure drop across the distributor. On
the gas side, a chimney-tray distributor with adequate pressure drop (e.g., a minimum of several mm
mercury) creates good gas distribution, especially when using a half-open feed pipe for gas entry into
the column. Packing-bed depth should not exceed 15-20 ft.
The Indian refinery's unit required more packing area in the low-pressure absorber. The packing bed
was divided into two bed areas, with a vapor-liquid redistributor installed between them.
When operating below designed feed-gas rates, a typical MDEA unit's amine-solution circulation rate
(both lean and rich) can be slightly lowered to achieve designed acid gas (CO2) mole/mole of amine
circulation and save on steam requirements during solution regeneration in the stripper. It's important,
however, to never reduce reboiler duty to the point where vapor traffic cools off. Such cooling could
leave the operator unable to maintain requisite amine levels in the reflux drum. A unit's amine-flow
turndown also could be limited by mechanical requirements such as pump turndowns or flow
requirements for packing spray coverage in the absorber.
Fig. 1 shows a diagram of the Indian refinery's MDEA unit.

Process flow
Rich charged MDEA collects in the bottom of the absorber column and is pumped to a CO 2 stripper
by the rich-amine solution pump, while a level control maintains the column level. The unit's rich-
amine solution pumps, both running and spare, are equipped with minimum-flow protection to prevent
spillback to the absorber. Before reaching the stripper, rich-amine solution is preheated by lean-
amine solution in the crossflow plate-and-frame heat exchanger. Amine solution flashes into the
stripper column across the absorber's level control valve, with valve placement downstream of the
exchanger helping minimize vaporization of gases in the plate-and-frame exchanger.2 The stripper
operates at a pressure of about 0.7 barg, with the kettle-type reboiler supplying the heat required for
stripping.
To adjust duty, a temperature controller partially floods the reboiler tubes with condensate, while a
temperature indicator located at the top of the column (above the reflux-return line) provides
feedback to the temperature controller. To prevent steam breakthrough, a low-level steam
condensate pot will override the temperature controller. On the overhead vapor line, an exchanger
condenses vapor to liquid.
Gas-liquid separation occurs in the reflux drum, liquid from which flows to the stripper via a level
control. The pressure control valve at the reflux drum's vent line controls tower backpressure, while
offgas vents to an atmospheric incinerator.
The heat energy required for amine regeneration in the stripper raises the temperature of feed
solution to the temperature of lean solution leaving the reboiler, reverses the amine-CO2 gas reaction
and dissociates the amine-CO2 compounds, and vaporizes reflux water into steam to serve as
stripper vapor.3
Heat exchanged with rich-amine solution in the crossflow plate-and-frame exchanger cools lean-
amine solution from the stripper before it is sent for further cooling by temperature-controlled
exchangers. A cool lean-amine slipstream is routed for mechanical and carbon filtering by packed
absorbers to scrub particulates entrained in feed gas that, if not properly removed, can cause fouling
and foaming in the unit.
Since water balance always affects MDEA concentration circulating through a unit by saturating
treated gas from the absorber and CO2 offgas from the stripper-which, over time, leads to system
water loss-makeup water added to the absorber's washing section can be increased to attain the
required MDEA strength.
If, however, a unit experiences amine loss caused by high vapor saturation at the vapor outlet of the
stripper's reflux drum, less makeup water may need to be added.
While treated gas can remove water from a unit by increasing the temperature of lean-amine solution
fed to the absorber, it is important to limit the temperature difference between feed gas to the
absorber and treated gas. Temperatures of feed gas and lean-amine solution fed to the absorber
should closely match to prevent high losses or oversaturation of solution. Saturation levels of treated
gas exiting the unit can be adjusted by changing the temperature of cooling wash water in the
absorber tower's wash section.
The temperature of lean-MDEA solution entering the absorber should be 50-60° C., as a temperature
below 50° C. may slow the rate of CO2 absorption due to decreased reaction speed. At lower
temperatures, however, even with a higher potential for absorption, a short residence in the packed
absorber will not be enough to reach required CO2-removal targets.

Precommissioning
Parallel commissioning of the MDEA unit and gas refining project enabled the refinery to increase
efficiency of precommissioning works, which included testing of electrical, mechanical, and partial
operational systems by methods such as valve and leak checks, pressurization, and lean and rich-
amine pump runs.
Because corrosion and foaming are common and serious problems for even the most well-designed
amine units, prestartup activities at the new MDEA plant focused on treating its stainless-steel
vessels and equipment to mitigate against corrosion and fouling mechanisms.
• Step 1. The absorber was degreased using a hydroflush of low-chloride water. Before flushing,
vortex breakers, bottom degassing packing, and orifice plates in liquid lines were removed, and
manholes in the tower column and tanks were opened.
• Step 2. After the operations team ensured that amine-solution pumps to the absorber were not
blocked by grease and grime, strainers were installed on the pumps' suction-sides to prepare the
absorber for a potassium carbonate wash (about 3 wt %) treatment. This also provided a good
opportunity both to test control valves and safety interlocks and to test the unit for leaks by
pressurizing the system with nitrogen to 80 kPag.
• Step 3. For the potassium carbonate wash, a low-chloride solution of potassium carbonate was
introduced at the stripper's bottom and the stripper was pressurized with nitrogen. The solution was
circulated in the system using a 10-hr rotation between both primary and spare rich and lean-amine
solution pumps (extra time should be taken, if available) at 50-60° C. Before emptying the system, a
few samples of potassium carbonate solution were taken from different locations within the unit for
visual inspection. The samples showed a relatively clear solution, so no additional washing was
required. The solution was neutralized for disposal and drained from the unit.
• Step 4. After reinstalling bottom degassing packing and orifice plates removed ahead of the Step 1
degreasing, the system was filled with clean, treated water circulated at 60° C. under the unit's
designed flow conditions using primary and spare rich and lean-amine solution pumps. Because this
clean-water circulation wash previews how water from the unit would react with fresh MDEA solution,
a sample of water was taken from the unit and mixed with a sample of MDEA matching the unit's
designed amine-solution concentration. Results of a foam test (described below) showed no
indication of foaming. If the clean water-MDEA solution mix had shown signs of foaming, a second
clean-water wash would have been required.
• Step 5. The system next was purged with N2 to bring the oxygen concentration below 0.4 vol %.
Using an activated carbon bed that processes an amine side slipstream (10-20% of main lean-amine
flow) is a good way to ensure an oil and particulate-free solution throughout the entire unit. An
improperly commissioned carbon bed, however, can lead to increased foaming.
Because of its highly porous nature, the activated carbon bed was filled in batches. The vessel was
filled first with 30% treated water and next with 30% of required activate carbon by volume. After the
activated carbon became saturated, additional batches of water and carbon were added. During the
saturation period, the vessel was vented. Supply water temperature was increased to help expedite
filling of carbon internal pores.
To eliminate any particles in the bed that could be carried out with solution and cause foaming, a
temporary 1-in. purge-water stream was added to the bed's bottom to act as a temporary backwash.
The water overfilled the tank and carried out small, unsaturated particles. The water flow rate was set
low enough (at 0.15 cu m/sq m) to prevent lifting of the particles

During startup, the unit's multistaggered-level gauge arrangement showed a


discrepancy between amine liquid levels in the vessel vs. levels in the gauge glass
(split-level gauge reading), an early indication of foaming inside the column (Fig. 3).
Unit operation
After pressurizing the absorber and stripper tower, MDEA-solution circulation was established. During
this startup phase, feed-gas flow initially bypassed the absorber by setting the bypass valve at 100%
open. The absorber's motorized inlet and outlet isolation valves then were slowly opened, which was
followed by a slow closing of the bypass around the absorber.
If feed gas had been introduced to the column all at once, CO2 absorption would have been almost
instantaneous. Such an initially high-removal rate of CO2 (constituting about 15-30% concentration in
feed gas) would have caused a decrease in forward flow of treated gas from the absorber as well as
a sudden loss of pressure to downstream units.
Absorber temperature profile
As CO2 absorbs into and reacts with the MDEA solution in the absorber, the heat of reaction
increases the solution's temperature as it descends the column. While the amine solution transfers
some heat to the feed gas at the absorber's bottom, feed gas ascending to the top of the absorber is
cooled to a temperature within a few degrees of the lean-amine solution entering the absorber. A
majority of the heat of reaction, then, is removed by the rich-amine solution pump at the absorber's
bottom. The temperature of rich-amine solution increases as acid gas (CO2) mole/mole of amine
loading increases.
During the MDEA unit's startup, up to 0.23 moles of acid gas (CO2) were removed per mole of lean-
amine solution entering the absorber (Fig. 2). The temperature of rich-amine solution exiting the
absorber was about 7° C. higher than the inlet lean-amine solution and about 12° C. higher than the
entering feed gas at 0.2 CO2 mole/mole of amine, suggesting an uneven temperature profile, or
bulge, inside the absorber (Box 2).

Process control issues


The MDEA unit entered operation well below design conditions because of limited feed-gas
availability, which caused the reboiler temperature to oscillate and become unstable at various
stripper loads.
Located at the top of the tower near the return-reflux tray, the column's temperature controller
required different tuning parameters at different loads. The different parameters avoided swinging the
reboiler duty and column pressure and leaving the pressure controller to try and catch up.
Erratic changes in tower pressure can cause liquid reflux to boil and create a surge of vapor at
different sections in the packing when vapor is at dew point. To remove the need for various sets of
tuning parameters, a cascading feed-forward control was temporarily added to set steam flow to the
reboiler based on the rich-amine solution flow rate and unit-tested ratio of kg of steam/cu m of rich
amine solution, ensuring sufficient stripping of CO2 in the previous test runs.
Investigation showed that placement of the temperature controller too close to the reflux inlet-line
nozzle caused the erratic temperature swings. The tower-top temperature controller subsequently
was relocated to the stripper column's overhead line during the unit's shutdown for routine
maintenance.
Units where the stripper's pressure is floating on the inlet pressure of a downstream unit (e.g., a
sulfur recovery unit) should use an alternative reboiler steam-control mechanism. Given otherwise
stable conditions, a tower with floating or oscillating pressure also will have an inherent change in the
tower-top temperature. Instead of using temperature to control reboiler duty, reboiler steam flow
should be adjusted to achieve a reflux ratio setpoint of 12 g of water/l. of lean amine (0.10 lb/gal)
exiting the stripper. Maintaining a good top-reflux rate also reduces reboiler-tube corrosion rates
caused by occasional rich amine entering the reboiler.
The MDEA unit eventually achieved acid gas (CO2)-loading mole/amine circulation at 0.33 mole
CO2/mole amine with an average stripping ratio of 60 kg of steam/cu m of amine solution (0.5 lb of
steam/gal of amine solution), a medium-pressure steam, and an MDEA-solution concentration of
about 32 wt % (Box 3).

Fouling, foaming
The MDEA unit includes two plate-and-frame exchangers working in parallel to cool and heat the lean
and rich-amine solutions, respectively. Over time, the exchangers showed signs of fouling as the
pressure drop and temperature approach began to increase. A sample of the fouling residue revealed
evidence of iron sulfide and iron carbonate. These compounds result from reactions of saturated feed
gas with high amounts of CO2 and carbon-steel piping feeding the unit.
Because of their tight spacing, plate-and-frame exchangers often serve as very effective filters. As
differential pressure eventually increases, however, they require cleaning to remove accumulation of
sticky, black dust. Each plate must be cleaned individually, as any material left or missed during
cleaning could cause the plate gasket enabling separation of hot and cold fluids to leak upon
resealing the exchanger.
During the unit's routine maintenance, the gaskets were removed and each groove cleaned before
reattachment to prevent leaks.
MDEA-unit design did not include upstream filtration on rich-amine solution exiting the absorber. This
filtration typically is left out to avoid handling acid-gas charged amine when opening the filters for
maintenance. Excessive particulates from iron sulfide and iron carbonate, however, can stabilize and
cause foaming in the amine solution (Box 4). Feed gas to the unit contained <10 ppm H2S. But any
amount of the accumulated black dust is pyrophoric and requires special safety precautions.
Particle-size analysis established the need to install, upstream of the cross exchanger, a mechanical
mesh filter able to drain, purge to the flare, and withstand high-pressure cleaning to remove wet
scale-sludge.
Amine losses
Amine loses can occur in both the absorber and stripper column. In the absorber, frequent causes of
such losses include accumulation of particulates because of poor filtration, undersized downcomers
in tray towers, high amine strength, and excessive acid-gas loading.
In the stripper, fitting a reflux drum that runs on total reflux with a reflux purge can draw off excess
water from steam leaks in the reboiler or cooling water in the condenser. This reflux purge will contain
a small percent of amines that will be lost when the water is drawn off.
The absorber's feed-gas inlet pipe and lean-gas outlet from the waterwash contained isolation valves.
In between the isolation valves, there was a small column bypass that adjusted CO2 levels to
maintain the absorber's outlet-CO2 specification for the gas plant. To avoid amine solution flowback
into the feed-gas line during periods of high amine levels in the absorber, typical units contain an
elevated, goosenecked feed-gas pipe above the feed-gas distributor (Fig. 4).

During initial operation of the MDEA unit, the absorber experienced amine-solution carryover into the
inlet line through the gooseneck pipe whenever the gas plant tripped or forward gas flow was
interrupted.
A shutdown of the upstream gas plant prompted checking the absorber's initial amine-solution level to
ensure it wasn't too high. Excess solution can spill into the distributor. A second investigation involved
verifying there was no foam inside the absorber, preventing potential buildup above the distributor.
Eliminating both a high amine level and foaming as cause of the carryover prompted investigation of
a new theory based on observations made during initial commissioning, this one involving unit
design.
While the absorber's inlet and outlet isolation valves were designed to close in the event of a plant
upset, the absorber bypass line downstream of the feed isolation valve remained open. Amine-
solution circulation through the absorber also continued as it would during normal operations.
During a plant trip, the isolated absorber would slowly lose gas pressure as amine entrained some
gas and carried it to the stripper. Allowing the absorber's internal bypass to remain semiopen during
the plant upset enabled pressurized gas inside the column to establish a natural vapor flow from the
absorber's bottom up through the column bypass, entraining some liquid-amine solution still flowing
down the packing.
A nitrogen purge installed downstream of the absorber bypass, modified to now close in the event of
an interruption at the upstream gas plant, tested the design-based issue as a possible cause of the
carryover problem. The newly added nitrogen valve was configured to open if the absorber's inlet and
outlet isolation valves closed to give the distributor a small forward purge.
During the next trip of the upstream gas plant after the modifications, the unit no longer experienced
amine-solution carryover, allowing the refiner to maintain amine-solution circulation without issue as it
waited for the upstream plant to resume operations.