Demands Description V N Vopp Load Type

This document summarizes the design checks performed on a beam-to-column connection. It provides the demands on the connection, geometric details, and results of 7 design checks comparing the capacity of various components to the demands. The critical strength ratio is 0.67, as the beam web shear capacity is the limiting check. Notes indicate unsuitable bolt grade, diameter and plate grades based on detailing recommendations.

Uploaded by

andibol
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
74 views1 page

Demands Description V N Vopp Load Type

This document summarizes the design checks performed on a beam-to-column connection. It provides the demands on the connection, geometric details, and results of 7 design checks comparing the capacity of various components to the demands. The critical strength ratio is 0.67, as the beam web shear capacity is the limiting check. Notes indicate unsuitable bolt grade, diameter and plate grades based on detailing recommendations.

Uploaded by

andibol
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

DEMANDS

Description V* N* Vopp* Load type


[KN] [KN] [KN]
----------------------------------------------------------------------
180.00 0.00 0.00 Design
----------------------------------------------------------------------

GEOMETRIC CONSIDERATIONS
Dimensions Unit Value Min. value Max. value Sta. References
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
CHECK 1 - Detailing requirements
End plate depth, di [mm] 210.00 150.00 -- DG6 Part D Sec. D1
Bearing pad depth, dj [mm] 200.00 150.00 -- DG6 Part D Sec. D1
Bearing pad width, bj [mm] 150.00 150.00 -- DG6 Part D Sec. D1
Bearing pad thickness, tj [mm] 20.00 20.00 24.00 DG6 Part D Sec. D1
End plate thickness, ti [mm] 20.00 12.00 -- DG6 Part D Sec. D1
CHECK 8 - Beam rotation check
Beam rotation 0.01 -- 0.02 DG3 Sec. 10.8
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

DESIGN CHECK
Verification Unit Capacity Demand Ctrl EQ Ratio References
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
CHECK 2 - Design shear capacity of beam web at end plate
Uncoped beam shear capacity [KN] 270.67 180.00 0.67 DG3 Sec. 10.5
CHECK 3 - Design bearing capacity at interface of plates
Interface bearing capacity [KN] 756.00 180.00 0.24 Cl. 5.13.3
CHECK 4 - Design capacity of end plate (compression)
End plate compression capacity [KN] 756.00 180.00 0.24 Cl. 6.2.1
CHECK 5 - Design capacity of bearing pad (compression/shear)
Bearing pad compression and shear capacity [KN] 756.00 180.00 0.24 DG6 Part D Sec. D6
CHECK 6 - Design capacity of weld to end plate
End plate weld capacity [KN] 919.43 180.00 0.20 Handbook 1 Sec. 4.5,
Cl 9.7.3.10
CHECK 7 - Design capacity of weld to bearing pad
Bearing pad weld capacity [KN] 391.00 180.00 0.46 Handbook 1 Sec. 4.5,
Cl 9.7.3.10
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Global critical strength ratio 0.67
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

NOTES
- Unsuitable bolt grade for recommended detailing, should be 8.8/S.
- Unsuitable bolt diameter for recommended detailing, should be 20 [mm] or 24 [mm].
- Unsuitable steel plate grade for recommended detailing, plates are either cut from plate (Grade 250) or are cut from standard square edge flat bar
components (Grade 300).