N Main Features: NOTE: " " This Terminal Not Present For A4 & C5 Type (MEET UL873 Spacing)

The document summarizes the main features, applications, ordering information, and specifications of the TR90 relay. The TR90 is a 30A SPST or 20A SPDT relay available as an open frame, with a dust cover, or sealed plastic case. It is used for power switching in applications like heating, cooling, and appliances. Ordering information includes coil voltage and current, contact arrangement, and insulation standards.

Uploaded by

Sailu Katragadda
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
90 views2 pages

N Main Features: NOTE: " " This Terminal Not Present For A4 & C5 Type (MEET UL873 Spacing)

The document summarizes the main features, applications, ordering information, and specifications of the TR90 relay. The TR90 is a 30A SPST or 20A SPDT relay available as an open frame, with a dust cover, or sealed plastic case. It is used for power switching in applications like heating, cooling, and appliances. Ordering information includes coil voltage and current, contact arrangement, and insulation standards.

Uploaded by

Sailu Katragadda
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

TR90

n MAIN FEATURES
Ÿ Up to 30A switching in SPST and 20A switching in spot arrangements.
Ÿ Available as an open-frame relay, with a snap-on dust cover or with an
immersion cleanable, plastic sealed case.
Ÿ Meet UL F Insulation class.

t. w
n APPLICATIONS
Ÿ Used for power switching, Electrical Heater, ventilator, Air conditioning,
Refrigerating, Automobile and House-hold Appliance.

m
n ORDERING INFORMATION

Structure F : Flux Free Type

c o
Nominal Coil Voltage : 5V , 6V , 9V , 12V , 15V , 18V , 24V , 48V , 110V

.
Type
S : Washable Type
Nil : Open Type

g
TR90 12V DC F B C F Nil : Stand
F : UL Class F insulation standard

n
Contact Material B : AgCdO (No need for A4 & C5 Type)

i
C : AgSnIn Contact Arrangement
A : 1 Form A

h
C : 1 Form C
A4 : 1 Form A without common Terminal between coil Terminals
UL class F insulation standard

s
C5 : 1 Form C without common Terminal between coil Terminals

i-
UL class F insulation standard

n DIMENSION(unit:mm) n DRILLING (unit:mm) n WIRING DIAGRAM

.t a
w
w
w
NOTE : “ * ” This Terminal not present for A4 & C5 Type ( MEET UL873 Spacing ).

Tai-Shing Electr onic Components Cor p. 69


n COIL DATA CHART (AT20¢C)
Coil Coil Voltage Nominal Nominal Coil Power Pull-In Drop-Out Max-Allowable
Sensitivity Code Voltage Current Resistance Consumption Voltage Voltage Voltage
(VDC) (mA) (W) ±10% (W) (VDC) (VDC) (VDC)
05 5 185 27
06 6 150 40
09 9 93 97
12 12 77 155
TR90 abt. 0.93W 80% Max. 10% Max. 120%Max.
15 15 59 256

t. w
18 18 47 380
24 24 36 660
48 48 19 2560
110 110 8 13450 ±15%

m
n CONTACT RATING n REFERENCE DATA

o
Type TR90
FORM C OPEN-STYTLE RELAYY,
FORM A FORM B

c
Item N/O N/C NO DUST COVER

.
Resistive Load 30A 240VAC 15A 240VAC 20A 240VAC 10A 240VAC 120
(cosF=1) 30A 28VDC 10A 28VDC 20A 28VDC 10A 28VDC 110
General 240VAC 2HP 240VAC 0.5HP 240VAC 2HP 240VAC 0.5HP

g
100
Motor 120VAC 1HP 120VAC 0.25HP 120VAC 1HP 120VAC 0.25HP

Temperature Rise (℃)


90
Tungsten TV-5 TV-3 TV-5 TV-3

n
80
Ballast 10A 277VAC 3A 277VAC 10A 277VAC 3A 277VAC

i
70
LRA/FLA 240VAC 80/30 240VAC 30/10 240VAC 50/20 240VAC 20/7 30A
60

h
50
20A
40
n PERFORMANCE (at initial value) 30
10A

s
20

i-
Type TR90 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0

Item UL508 UL873 Coil Power (W)


Contact Resistance 100mW Max. SEALED RELAY

t. a
Operation Time 15msec Max.
Release Time 10msec Max. 160

Dielectric Strength 140


Between coil & contact 1500VAC 50/60HZ (1 minute) 2500VAC
120
Between contacts 1500VAC
Insulation Resistance 10 MW Min. (500VDC) 100

w
Temperature Rise(℃)

Max. ON/OFF Switching 80 30A


Mechanically 300 operation/min 60
Electrically 30 operation/min 20A

w
40
Operating Ambient -55° to +85°C (operating)with UL approval 10A
Temperature -55° to +105°C (operating)without UL approval 20

-55° to +155°C (storage)

w
0
0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0
Operating Humidity 45 to 85% RH
Coil Temperature Rise 60 deg. Max. Coil Power (W)
Vibration
Endurance 10 to 55Hz Double Amplitude 1.5mm
Error Operation 10 to 55Hz Double Amplitude 1.5mm
Shock
Endurance 100 m/sec2(abt. 100g’s)
Error Operation 10 m/sec2(abt. 10g’s)
Life Expectancy
Mechanically 10 ´ 106
Electrically 10 ´ 104
Weight abt. 22grs, 28grs(SEALED)
UL File No. E156406
CSA File No. LR700159

70 Tai-Shing Electr onic Components Cor p.