3UG48221AA40 Datasheet en
3UG48221AA40 Datasheet en
3UG48221AA40 Datasheet en
Measuring circuit:
Number of poles for main current circuit 1
Type of current for monitoring AC/DC
Measurable current A 0.05 ... 10
Measurable current at AC mA 50 ... 750 000
Measurable line frequency Hz 500 ... 40
Adjustable pick-up value current
●1 A 0.05 ... 10
●2 A 0.05 ... 10
Adjustable response delay time
● when starting s 0 ... 999.9
● with lower or upper limit violation s 0 ... 999.9
Adjustable switching hysteresis for measured current mA 5 ... 10
value
Operating voltage rated value V 24 ... 24
Response time maximum ms 450
Relative metering precision % 5
Accuracy of digital display +/-1 digit
Communication/ Protocol:
Type of voltage supply via input/output link master Yes
IO-Link transfer rate COM2 (38,4 kBaud)
Protocol is supported IO-Link protocol Yes
Amount of data
● of the address area of the outputs with cyclical byte 2
transfer total
● of the address area of the inputs with cyclical byte 4
transfer total
Point-to-point cycle time between master and IO-Link ms 10
device minimum
Mechanical data:
Width mm 22.5
Height mm 92
Depth mm 91
Mounting position any
Required spacing for grounded parts
● forwards mm 0
● Backwards mm 0
● at the side mm 0
● upwards mm 0
● downwards mm 0
Required spacing with side-by-side mounting
● forwards mm 0
● Backwards mm 0
● at the side mm 0
● upwards mm 0
● downwards mm 0
Required spacing for live parts
● forwards mm 0
● Backwards mm 0
● at the side mm 0
● upwards mm 0
● downwards mm 0
Mounting type snap-on mounting
Type of electrical connection
● for auxiliary and control current circuit screw-type terminals
Outputs:
Number of NO contacts delayed switching 0
Number of NC contacts delayed switching 0
Number of CO contacts delayed switching 1
Ampacity
● of the output relay
— at AC-15
— at 250 V at 50/60 Hz A 3
— at 400 V at 50/60 Hz A 3
— at DC-13
— at 24 V A 1
— at 125 V A 0.2
— at 250 V A 0.1
● for permanent overcurrent maximum A 15
permissible
Operating current at 17 V minimum A 0.01
Continuous current of the DIAZED fuse link of the A 4
output relay
Thermal current of the switching element with A 5
contacts maximum
Mechanical service life (switching cycles) typical 10 000 001
Electrical endurance (switching cycles) at AC-15 at 100 000
230 V typical
Operating frequency with 3RT2 contactor maximum 1/h 5 000
Certificates/ approvals:
Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
http://www.siemens.com/industrial-controls/catalogs
Industry Mall (Online ordering system)
http://www.siemens.com/industrymall
Cax online generator
http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3UG4822-1AA40
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/ww/en/ps/3UG4822-1AA40
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3UG4822-1AA40&lang=en
11
IN
L-
<I>
IO-Link
12
14
M