Powercom Vanguard
Powercom Vanguard
Main Features
True on-line technology provides all power protection
Pure sine wave output with less than 3% THD
Fully digitized microprocessor controlled
LCD display front panel Special Features
Wide input voltage range 15 UPS status display
Power factor correction Easy viewing of UPS status from LCD panel including
Output Voltage Output Load (%) Battery Charge (%)
Lightning and surge protection
Output Frequency Output Watt (W) Temperature (°C)
EMI/RFI noise filter Input Voltage Output VA Battery Pack Number
Short circuit and overload protection Input Frequency Output Currency (A) Rating (VA)
Battery Voltage Back Up Time (Min.) CPU Version
Cold start function (DC power on)
Advanced battery management (ABM) 14 UPS parameter setting
Output Voltage Set Manual Bypass Site Failure Set
Automatic battery charge in UPS off mode
Input Frequency Set Outlet Segment Set Language Selection
Battery replacement warning Input Bypass Set Battery Set Generator Option Set
Automatic diagnostics and battery check Free Run Set Silence Mode Set RS-232 Control
High Efficiency Mode Battery Cabinet Set
Load segmentation receptacles controllable
Fan speed auto control when load varies Load segmentation receptacles controllable
Extended back up time with battery pack Emergency power off (EPO) function
Network/fax/modem surge protection LAN/TEL/Modem surge protection
SNMP control card (option)
UPSMON plus software monitoring
Extended battery pack (EBP, option)
Hot swappable battery by user USB communication port (option)
Emergency power off (EPO) function
High efficiency mode selectable
Battery remain time display Powercom UPSMON Suite
Multiple language LCD display The industrys most comprehensive
On line output voltage selected software bundle, the Powercom
software suite, is free and included
RS-232 communication port with UPSMON software with every Powercom Vanguard UPS.
Support USB communication
UPSMON plus wizard guides you
Manual bypass setting through software selection and
Free run mode setting installation.
Optional extension battery pack UPSMON plus features the following
Optional SNMP card slot power management software:
Automatic shutdown Battery level display
User notification of power events Power quality data log
UPS power events log Printing power events list
Automatic reboot Graphic display by meter
Broadcast power abnormal status Support Windows NT service and start UPS
Smart save file monitoring software before user log in under
Scheduled system shutdown /reboot Windows 95/98/ME/NT/2000/XP.
UPS battery low warning Compatible with Windows 95/98/NT/2000/XP/2003
Server, Novell and Linux etc.
Real-time graphical display
Front Panel Display Tower Model 19 Rack-Mount Model
Informative user interface with LCD, five LED and audible alarms. Power rating 700VA, 1kVA, 1.5kVA, 2kVA and 3kVA Power rating 700VA-1kVA, 1U model
Power rating 700VA-3kVA, 2U model
1 UPS On 6 LCD display
2 On-Line mode 7 Select UPS setting
3 Battery mode 8 Start Up/Shuts Down UPS
4 On Bypass mode 9 Select UPS setting parameter
5 Alarm
1
7
2
3
4
8
5
VGD-700, 1000
9 and 1500 VGD-700-RM to VGD-3000-RM (front, 2U)
VGD-2000 and 3000
Vanguard Specifications
Tower Model VGD-700 VGD-1000 VGD-1500 VGD-2000 VGD-3000
19 Rack-Mount Model VGD-700-RM VGD-1000-RM VGD-1500-RM VGD-2000-RM VGD-3000-RM
Input Capacity (VA) 700VA 1000VA 1500VA 2000VA 3000VA
Power Factor Correction > 0.99
Voltage 220Vac ±27%
Frequency 50Hz ±10%
Output Voltage 208, 220, 230 and 240Vac ±1% (selectable output voltage)
Frequency 50Hz ±0.1%
Transfer Time 0 ms
Overload recovery Auto transfer to UPS
High Efficiency Mode (AC to AC) > 95%
UPS Design Technology True on-line double conversion, full digitized microprocessor controlled
Output Wave Form Sine wave
Harmonic Distortion < 3% of THD at linear load
Crest Factor 3:1
Protection and Surge Protection 220V (IEEEC6100-4-5 level 3)
Filtering Overload Protection 150% for 30 seconds
Short Circuit Protection UPS output cut off immediately or input fuse/circuit breaker protection
System Display and Visual Display (LED) UPS on (green), line-mode (green), battery mode (yellow), bypass (yellow) and fault (red)
Warning Visual Display (LCD) Input/output voltage, input/output frequency, on-line mode, back up mode, battery capacity and load level
Audible Alarm (battery back up) Beep every 5 sec
UPS Fault Continuous beeping sound and LCD display
Communication RS-232 serial port (option for USB port)
Battery Type Sealed, maintenance-free lead acid batteries
Typical Recharge Time to 90% Full 4 hours
Management Self-test, adjustable battery transfer points and alarm setting
Battery Protection Cut off without draining any current when battery is low
Cold Start (DC start) Yes
Back Up Time 15 minutes
Expansion Back Up Time Optional
Physical Tower Model Dimensions 155 × 400 × 240 (5.7 × 15.7 × 9.4) 215 × 405 × 370 (7.6 × 18.1 × 14.6)
W × D × H, mm (inch)
19 Rack-Mount Model Dimensions 428 × 610 × 44 (16.9 × 24.0 × 1.7) for 1U None
W × D × H, mm (inch) 428 × 425 × 84 (16.9 × 16.7 × 3.3) for 2U 428 × 610 × 84 (16.9 × 24 × 3.3) for 2U
Tower Model Net Weight, kg (lb) 12.0 (26.4) 13.0 (28.6) 17.0 (37.4) 27.0 (59.4) 33.0 (72.6)
Tower Model Shipping Weight, kg (lb) 15.0 (33.0) 16.0 (35.2) 20.0 (44.0) 31.0 (68.2) 37.0 (81.4)
Environment Operating Temperature 0~40 °C (32~104 °F)
Storage Temperature -20~50 °C (-4~122 °F)
Altitude 3,500 meters max
Audible Noise (1 meter from surface) <40 dBA
Relative Humidity 0~95% humidity, non-condensing
Conformance Safety EN 50091-1-1/EN 6095, IEC 60950
Electromagnetic Compatibility EN 50091-2, EN 55022/B, IEC 62040-2, IEC 61000-3-2, IEC 61000-4-2/3/4/5
Specifications are subject to change without notice. All brands and logos are registered trademarks of their respective owners.