TD1005 Free and Forced Convection Datasheet 0518 PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

thermodynamics

T D1 0 0 5
free and forced convection
Shows free and forced convection from different heat
transfer surfaces.

Screenshot of the Optional VDAS ®


sof twa re

K ey f e at u res Learning Outcomes


• Includes three of the most common heat • Comparing free and forced convection for different
transfer surfaces: flat plate, pinned and finned surfaces
• Thermocouples and a sensitive anemometer • Comparison of free convection from vertical and
measure temperatures and air velocity – horizontal (finned) surfaces
shown on a digital display
• Comparison of heat transfer surface efficiency
• Additional hand-held thermocouple probe
• Comparing the coefficient of heat transfer and Nusselt
included – to measure temperatures along
Number for forced and free convection
the length of the pins and fins of two heat
transfer surfaces • Temperature distribution along finned and pinned
surfaces
• Variable-speed fan and variable power heat
source for a range of tests
• Can connect to TecQuipment’s Versatile Data
Acquisition System (VDAS®)

TecQuipment Ltd, Bonsall Street, long eaton, Nottingham NG10 2AN, UK


tecqu ipment. c o m +4 4 115 972 2611 [email protected]

DB/bw 0518 Page 1 of 3


T D1 0 0 5

free and forced convection


Description Two controls allow students to set different air velocities
and heater power for a full range of tests.
The bench-mounting equipment includes a vertical
duct that holds the chosen heat transfer surface and all A digital display shows the heater power, air velocity and
instruments needed. the temperatures measured by the thermocouples.
TecQuipment includes three different common heat You can do tests with or without a computer connected.
transfer surfaces with the equipment: However, for quicker tests with easier recording of results,
TecQuipment can supply the optional Versatile Data
• A flat plate
Acquisition System (VDAS®). This gives accurate real-time
• A pinned surface – similar to a tubular heat exchanger data capture, monitoring and display, calculation and
charting of all the important readings on a computer
• A finned surface – similar to the fins on air-cooled
(computer not included).
engines or electrical heat sinks
Each surface has its own built-in variable-power electric R ec o mmend ed Anc illar ies
heater. Students choose which surface they need to test • VDAS-B (bench-top version of the Versatile Data
and fit it to the duct using simple fixings. Acquisition System)
For free convection tests, the heated air rises from the
surface and up the duct. For forced convection tests, a Standard Features
variable-speed fan draws air up through the duct and • Supplied with comprehensive user guide
across the surface. Thermocouples measure the air
temperature upstream and downstream of the surface • Five-year warranty
and the temperature at the heat transfer surface. The • Made in accordance with the latest European Union
downstream probe moves in a traverse mechanism to directives
measure the temperature distribution across the duct,
allowing calculation of the bulk outlet temperature. • ISO9001 certified manufacturer
An additional probe allows students to measure the
temperature distribution along the extended surfaces of
the pinned and finned heater transfer surfaces. A sensitive
anemometer measures the air velocity.

Pi nne d S ur fac e

1200 mm

Fin ne d S urfac e

F l at p l at e
550 mm

850 mm

TecQuipment Ltd, Bonsall Street, long eaton, Nottingham NG10 2AN, UK


tecqu ipment. c o m +4 4 115 972 2611 [email protected]

DB/bw 0518 Page 2 of 3


T D1 0 0 5

free and forced convection


O p e rat i n g C on di ti ons Essential Services
O per at ing env iro nme n t: B ench space needed:
Laboratory 850 mm x 550 mm, plus space for a suitable computer if
you need to use the optional VDAS
Note: This equipment accurately measures temperatures
and low speed convection air flow, so you must use it in a Electrical supply (determined by order):
laboratory with stable temperature and airflow conditions, • 220 to 240 VAC 50 Hz to 60 Hz at 0.6 A
away from direct heat sources and sunlight.
or
Storage temperature range:
• 110 to 120 VAC 50 Hz to 60 Hz at 1.2 A
–25°C to +55°C (when packed for transport)
O per at ing t emper at ur e r a n ge : Technical Details
+5°C to +40°C TecQuipment is committed to a programme of continuous
O per at ing r el at iv e hum i d i ty r a n ge : improvement; hence we reserve the right to alter the
design and product specification without prior notice.
80% at temperatures < 31°C decreasing linearly to 50% at
40°C Net t dimensio ns a nd weight ( when assemb led wi th
anemometer on duct):
Sound Levels 850 mm wide x 550 mm front to back x 1200 mm high and
Less than 70 dB(A) approximately 30 kg (including the three heat transfer
surfaces)
Approximate packed vo lume and weight:
0.6 m3 and 40 kg

TecQuipment Ltd, Bonsall Street, long eaton, Nottingham NG10 2AN, UK


tecqu ipment. c o m +4 4 115 972 2611 [email protected]

DB/bw 0518 Page 3 of 3

You might also like