0% found this document useful (0 votes)
75 views2 pages

Sewerage: Gravity Collection Parameters

This document provides minimum and maximum slope parameters for sewerage and drainage pipes of various diameters. The slopes are specified in millimeters per meter. It also lists recommended flow velocity ranges of 0.75 to 2.5 meters per second.

Uploaded by

akash nair
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
75 views2 pages

Sewerage: Gravity Collection Parameters

This document provides minimum and maximum slope parameters for sewerage and drainage pipes of various diameters. The slopes are specified in millimeters per meter. It also lists recommended flow velocity ranges of 0.75 to 2.5 meters per second.

Uploaded by

akash nair
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 2

GRAVITY COLLECTION PARAMET

SEWERAGE
Min. Slope Max. Slope
Diameter (mm) (mm per metre) (mm per metre)

160 6.60 74.00

200 4.90 55.00

250 3.65 41.00

315 2.70 30.20

400 2.00 22.15

500 1.50 16.65

600 1.20 13.20

700 0.97 10.85

800 0.82 9.15

900 0.71 7.90

1000 0.62 6.95

Flow Velocity 0.75 m/s 2.5 m/s


ECTION PARAMETERS

DRAINAGE
Min. Slope Max. Slope
Diameter (mm) (mm per metre) (mm per metre)

160 4.30 55.50

200 3.23 41.00

250 2.43 31.30

315 1.81 23.35

400 1.34 17.30

500 1.02 13.10

600 0.81 10.45

700 0.67 8.60

800 0.57 7.30

900 0.49 6.30

1000 0.49 5.55

Flow Velocity 0.75 m/s 2.5 m/s