Schaltbau S800

Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

Connect - Contact - Control

2 Snap-action switches

Series
S800, S804, S814, S820
Changeover switches
with double-break contacts
and positive opening operation
Catalogue D20.en

more information here:


schaltbau-gmbh.com
2

Snap-action switches, S800, S804, S814, S820 Series

Featuring double-break contacts and positive opening operation

S800 and S804 series – application proven snap switches  S820 – snap switches featuring higher ampacity
S800 and S804 series switches feature a VDE approved positive opening S820 series switches add to the well proven standard products, offering a
operation which guarantees - within the requirements of the standard - current-carrying capacity which is twice as high (Ith = 20 A) as for example
the forced opening of contacts that have become welded together after S800, as well as a more ruggedized design making them best suited for
a short-circuit. This makes them ideally suited for use in all safety related use under unfavourable ambient conditions which call for higher shock
applications. and vibration resistance. A typical field of application is medium-voltage
switchgear and controlgear.
S814 series The S820 is a Form Zb SPDT-DB switch with double-break contacts. Its
The S814 has a plunger running through the switch. This makes it possible two mechanically linked rigid contact bridges are galvanically isolated,
to mount two switches on top of each other, and trigger two operations thus ensuring the failsafe closing of two separate load circuits with
with only one actuation. Wiping contacts ensure high contact reliability independent voltage levels.
over the life of the switch.

Features   Series S800/S804/S814/S820

Positive opening operation: Reliable interruption of IP rating:  Protection against dust, hazardous substances
both circuits even after contact welding, in compliance and direct contact with live parts in compliance with IP40
max
with IEC 60947-5-1, Annex K (except for S814) IEC 60529: Contacts IP40 / Terminals IP00

Contact material:  Ag
Double-break contacts:  High electrical rating due to rigid
S800 and S814:  Silver or Gold
contact bridge Au
S804 and S820:  Silver

Precision switch: High switching accuracy and resistance Blowouts:  Optional magnetic blowout to ensure efficient
to shock and vibration quenching of electric arcs and high DC switching capacity

Switch design and function   Series S800/S820

●● Standard: Pushbutton
►► Actuators 
●● Aux. actuator: roller lever

●● Front mount
►► Mounting styles 
●● Side mount (ganging)

●● Double-break contacts and rigid contact bridge


►► Contacts  ●● Positive opening operation
●● Contact material: silver or gold
●● M3 screws with saddle clamp
►► Terminals  ●● Flat tabs 6.3x0.8
●● M3 screws with spring washer

Competence   Applications   Series S800/S804/S814/S820

The success of a product is owed to its quality Schaltbau snap-action switches are typically used with systems and
The Schaltbau product line is clearly defined and keeps up with the techno- components that require a high degree of safety and reliability, such as:
logical requirements of today‘s markets. Behind every individual snap-action ●● Limit switches for machine, door and plant control systems
switch you will find decades of experience in engineering and manufacturing. ●● Aux. switches in cam gear and control and indicating devices
Snap-action switches are designed with a snap-mechanism that allows fast ●● Switching elements for automation
switching, largely independent of the actuation speed. This precisely repro- ●● Safety limit switches for control systems and plant controls
duces the operating position, and controls the arc more efficiently.
With their well known transparent-green housing, the safety function in
Schaltbau´s snap-action switches is visible.
Subject to technical alterations
3

Specifications   Series S800/S804/S814/S820

Standard S800, S804 S814 S820

Contact configuration IEC 60947


  SPDT-DB switch, contact bridge:
   rigid (Form Za)
--- S800 b20
   galvanically isolated (Form Zb)
--- --- Version with pushbutton
  Positive opening operation
--- (standard),
  Wiping action --- --- silver contacts and
flat tabs 6.3 x 0.8
Conv. thermal current Ith IEC 60947 10 A at T = 85° C 10 A at T = 85° C 20 A at T = 85° C

IEC 60947 400 V 250 V 400 V


Rated insulation voltage Ui
UL 508 300 V *1 --- ---
IEC 60947 PD3 PD3 PD3
Pollution degree
UL 508 D3 *1 --- ---
Rated impulse withstand voltage Uimp IEC 60947 4 kV 2.5 kV 4 kV
S800 aL
IEC 60947 OV3 OV3 OV3 Version with roller lever,
Overvoltage category mounting brackets,
UL 508 V3 *1 --- ---
silver contacts,
AC-15: 230 V / 3.0 A AC-15: 230 V / 1.0 A AC-15: 230 V / 5.0 A M3 screws with saddle clamp
IEC 60947 and blowouts
Utilization category DC-13: 110V / 1.0 A DC-13: 60V / 0.5 A DC-13: 110V / 1.0 A
  for silver contacts *2 240 V AC, 8 A
UL 508 *1 general purpose --- ---

Contact gap, typ. IEC 60947 2x 1.2 mm 2x 0.4 mm 2x 2.0 mm


Contact force, typ. IEC 60947 0.35 ... 0.75 N 0.4 N 1.2 N
Contact resistance, typ. IEC 60947 100 mΩ (no leads connected)
Positive opening force *3 IEC 60947 35 N --- 35 N
S800: see page 5
Actuator travel for positive opening IEC 60947 --- see page 13
S804: see page 9
S800 e20
Maximum actuator travel *3 IEC 60947 3,2 mm 2,0 mm 4,0 mm Version with roller lever,
silver contacts and
max. 1 m/s max. 240 mm/s max. 1 m/s
Actuating speed IEC 60947 flat tabs 6.3 x 0.8
min. 1 mm/s min. 0,1 mm/s min. 1 mm/s
Vibration resistance, no aux. actuator,
at 0.1 ms max. opening time
IEC 60068-2-6
  10 … 150 Hz all directions 30 g 20 g ---
  10 … 500 Hz all directions --- --- 50 g
Shock resistance
  (no aux. actuator IEC 60068-2-27 80 g, half sinus 50 g, half sinus 60 g, half sinus
  at 0.1 ms max. opening time)
S804 b
Short-circuit protection Version with pushbutton
IEC 60269-2 6 A gR --- 6 A gR
for silver contacts *2 (standard),
silver contacts and
Operating frequency, max. IEC 60947 465 cycles/min 300 cycles/min 80 cycles/min M3 screws with saddle clamp
Actuating force *3
IEC 60947
  Standard / reinforced 3.3 N / 5,5 N 3.2 N / 5,2 N 8 N / 18 N
Release force *3
IEC 60947
  Standard / reinforced 0.2 N / 2.9 N 0.5 N / 2.0 N 1.5 N / 2.0 N
IP rating
 Contacts IEC 60529 IP40
 Terminals IP00 S814 b
Version with pushbutton
Mechanical endurance, cycles IEC 60947 10 million min. 1 million min. (standard),
silver contacts and
Temperature range IEC 60947 -40 °C … +85 °C M3 screws with saddle clamp
Material
 Contacts Hard silver (AgCu3) or gold (AuAg26Ni3) Hard silver (AgCu3)
 Terminals --- Brass, silver or gold plated Brass, silver-plated
 Housing PC, light green, transparent PES, amber, transparent
Mounting orientation --- any
Weight, no aux. actuator --- S800: 26 g / S804: 25 g 25 g 45 g
*1

Approvals ---   C US
   

S820 a7
Version with roller lever,
*1  S800 series only mounting brackets,
*2  S800 and S814 only: Data for gold contacts on request Note:  silver contacts and
*3  Measured next to actuator Data valid for new switches under laboratory conditions M3 screws with saddle clamp
and at room temperature, unless otherwise mentioned.
Subject to technical alterations
4

S800  Ordering code, Accessories Series S800

●● Ordering code
Example:   S800 b10/20/40 L 
Series, Contact configuration    Special designs, optional
S800 Form Za SPDT-DB switch with positive opening Blowouts L
operation and rigid contact bridge
  Actuating and release forces
Actuator and mounting styles  Standard *
Actuator Front mount Stronger reset spring 40
b Pushbutton no mounting brackets
 Terminals
c Pushbutton with mounting brackets
M3 screws with saddle clamp *
e Roller lever no mounting brackets
Flat tabs 6.3x0.8 20
a Roller lever with mounting brackets
as Roller lever with mounting brackets,
slotted holes
d Roller lever with mounting brackets,
angled on one end
Contact material 
* Silver
Note:
10 Gold This catalogue shows only stock items. For some variants
minimum quantities apply. Please ask for the conditions.
Special variant:
If you need a special variant of the switch, please do not
hesitate to contact us. Maybe the type of switch you are
●● Accessories looking for is among our many special designs. If not, we
can also supply customized designs. In this case minimum
SK-100 Protective housing (half shells) made of PA6
quantities apply.
SK-200 Protective cover made of flexible soft PVC
SK-400 Protective cap made of glass fibre reinforced PC *  No index

Parameter Code Version


IP rating: contacts / terminals IP40/20
Actuator styles

►► Pushbutton (standard)
b
No mounting brackets

►► Pushbutton
c
with mounting brackets

►► Roller lever
e
No mounting brackets

►► Roller lever
a
with mounting brackets

►► Roller lever
with mounting brackets, as
slotted holes

►► Roller lever
with mounting brackets, d
angled on one end

►► Series S800
►► Contact material * / 10 S800
Ag
►► Actuating and release force * / 40
►► Blowouts (special design) L
Terminal styles

►► M3 screws with saddle clamp --- *

►► Flat tabs 6.3x0.8 20

Subject to technical alterations


5

Dimension and circuit diagrams   Series S800

●● Dimensions S800 b  Form Za SPDT-DB switch Circuit diagram

3 4
3 4
1 2 1 2

Front mount (M3)


42 Torque 0.9 Nm max.
28 Side mount / ganging
Torque 1.0 Nm max.
8.4
13

2.2
M3

S800
8.85 ±0.2

30
4KV/3
Form Za SPDT-DB switch with positive
3.5
5 ... 6.5

>PC-FR< N N S N
opening operation, silver or gold contacts
4.1

and rigid contact bridge


50 12 max. S800  b Pushbutton (standard)

Blowout magnets (optional)


for increased DC breaking capacity

Screwable thread length of Free position


fastening screw

Actuator styles and positions Series S800

●● S800 Pushbutton ( standard)  b / c

Actuator positions Pushbutton (standard)  b  /  c


Dimension in mm
Free position 8.85 ± 0.20
Operating position 6.60 ± 0.35
Release position 7.80 ± 0.35
Total positive opening travel 5.85
Total travel position 5.65
Movement differential
1.3
(between operating and
(typical)
release position)

Note:  To ensure proper operation of the positive opening function it is


necessary to depress the plunger to the point of total positive opening travel.
However, it must not be pushed beyond total travel position.
Data is valid for new switches.

●● S800 Roller lever  e / a / as / d

7,1 6,8
Actuator positions Roller lever  e  /  a  /  as  /  d
8 Dimension in mm
Free position 20.25 ± 0.35
Operating position 16.60 ± 0.50
Release position 18.40 ± 0.50
Total positive opening travel 13.60
Total travel position 13,3 min.
Movement differential
2.2
(between operating and
(typical)
release position)

Note:  To ensure proper operation of the positive opening function it is


necessary to depress the plunger to the point of total positive opening travel.
However, it must not be pushed beyond total travel position.
Data is valid for new switches.

Dimensions in mm / Subject to technical alterations


6

Mechanical fastening  Front mount, ganging Series S800

Front mount Ganging


●● No mounting brackets:  By way of the nut retainers (M3) that are ●● Through the transversal bore holes with 4 mm screws or bolts.
inserted into the switch housing. Torque 0.9 Nm max. Torque 1.0 Nm  max.
●● With mounting brackets:  By way of M3 screws for all actuator styles. ●● Alternatively DUO clips or retaining rings can be used.
Torque 0.9 Nm max.

Actuators without mounting brackets  Actuators with mounting brackets 

●● Pushbutton (standard)  style b ●● Pushbutton style c

max.
max.

Front mount

12
12

9
M3

3,5
3.5
Max. screwable thread length
of fastening screw

1
28 58
5 ... 6.5

42 67

●● Roller lever style a

Ganging
max.
max.

12
12

9
(side mount)

3,5
4.1

1
3.5

58
28
67

●● Roller lever style e ●● Roller lever style as


max.
max.

12
12

9
3,5
1

4.1 58
3.5

28 67

●● Roller lever style d
max.
12

9
3,5

3,2
3
1

29 31
68,7

Terminal styles  M3 screws, flat tabs 6.3x0.8 Series S800

●● M3 screws with saddle clamp (standard)  style * ●● Flat tabs 6.3x0.8  style 20

3 4 3 4

1 2 1 2
50 *  No index 75

Note: 
●● Single and multiple-wire conductors with wire gauges AWG 18 ... 12 (0.75 mm² ... 2.5 mm²) can
be clamped without wire end ferrules. If a ferrule is used the maximum wire gauge is AWG 14
(1.5 mm² max.)
●● Max. 2 conductors with the same wire gauge can be clamped per terminal.
●● Tightening torque of terminal screws should be 0.9 Nm max.
●● IP rating: contacts IP00 / terminals IP40 Dimensions in mm / Subject to technical alterations
7

Instruction  on when to use a roller lever (examples) Series S800

Snap-action switches are designed for actuation with and without roller lever. A roller lever is required,
if the direction of actuation deviates more than ±15° from the perpendicular line.
●● Switch with roller lever actuated by cam disk ●● Switch with roller lever actuated by trigger cam

Total travel pos. + 0.2 ... 0.3


Free pos. + 0.2 ... 0.3

Total travel pos. + 0.2 ... 0.3


Free pos. + 0.2 ... 0.3
≥4

° ≥40
≥40 °

Stroke 5 min.
Stroke 7 max. 1 max.
Stroke 5 min.
Stroke 7 max. 1 max.

Cam disk  Clearance 


40 mm 3.6 mm
60 mm 0 mm
100 mm (max.) 0 mm

Protective housing  SK-100, SK-200, SK-400, SK-400-B Series S800

SK-100 SK-200
Protective housing (half shells) made of fibre glass reinforced PC. Screw- Protective cover made of flexible soft PVC. Protective cover SK-200 pre-
type terminals of switches used with protective housing SK-100 are vents accidental contact with the 4 live M3 screw terminals.
sealed to IP40.

Note:  Note: 
For use with screw-type terminals For use with screw-type terminals
(M3 screws) only. (M3 screws) only.
38,5
55

58

Strain relief
10

Bore hole for cable clamp


1,5
32

Cable clamp:
for cable diameter 5 ... 8 mm
Retention force: 80 N min.
14.5

Cable clamp:
for cable diameter 8 ... 10.9 mm
Retention force: 80 N min.
14.5

61,5

SK-400
Protective cap made of fibre glass reinforced PC. Protective cap SK-400
prevents accidental contact with the 4 live M3 screw terminals.
37.5
33
27

52.5 14

Dimensions in mm / Subject to technical alterations


8

S804  Ordering code Series S804

Example:   S804 b40 
Series, Contact configuration 
S804
Form Za SPDT-DB switch with silver contacts,
positive opening operation, and rigid contact bridge

Actuator and mounting styles 


b Pushbutton

Actuating and release force 


* Standard
40 Stronger reset spring

Note:
This catalogue shows only stock items. For some variants
minimum quantities apply. Please ask for the conditions.
Special variant:
If you need a special variant of the switch, please do not
hesitate to contact us. Maybe the type of switch you are
looking for is among our many special designs. If not, we
can also supply customized designs. In this case minimum
quantities apply.
*  No index

Parameter Code Version


IP rating: contacts / terminals IP40/20
Actuator style

►► Pushbutton (standard) b

►► Series S804 S804


►► Actuating and release force * / 40

Terminal style

►► M3 screws with saddle clamp --- *

Subject to technical alterations


9

Dimension and circuit diagrams   Series S804

●● Dimensions S804 b  Form Za SPDT-DB switch Circuit diagram

28±0.15 13.4 max. 3 4


8.2
1 2
3.2±0.1

13.35
17.1
4.5
30

8.2

25 7.2
Free position

Mount / ganging S804


Torque 1.0 Nm max.
Form Za SPDT-DB switch with positive
Terminal screws opening operation, silver contacts and
22

M3 with saddle clamp rigid contact bridge


Torque 0.9 Nm max.
S804  b Pushbutton (standard)
36
Note: 
●● Single and multiple-wire conductors with wire gauges
AWG 18 ... 12 (0.75 mm² ... 2.5 mm²) can be clamped with-
out wire end ferrules. If a ferrule is used the maximum wire
gauge is AWG 14 (1.5 mm² max.)
●● Max. 2 conductors with the same wire gauge can be
clamped per terminal
●● IP rating: contacts IP00 / terminals IP40

Acutator style and positions   Series S804

●● S804 Pushbutton ( standard)  b

Actuator positions Pushbutton (standard)  b


Dimension in mm
Free position 13.35 ± 0.15
Operating position 11.10 ± 0.35
Release position 12.30 ± 0.35
Total positive opening travel 10.35
Total travel position 10.15
Movement differential
1.3
(between operating and
(typical)
release position)

Note:  To ensure proper operation of the positive opening function it is


necessary to depress the plunger to the point of total positive opening travel.
However, it must not be pushed beyond total travel position.
Data is valid for new switches.

Dimensions in mm / Subject to technical alterations


10

S814  Ordering code Series S814

Example:   S814 b10/40 
Series, Contact configuration 
S814
Form Za SPDT-DB switch with rigid contact bridge

Actuator style 
b Pushbutton

Contact material 
* Silver
10 Gold

Actuating and release force 


* Standard
40 Stronger reset spring

Note:
This catalogue shows only stock items. For some variants
minimum quantities apply. Please ask for the conditions.
Special variant:
If you need a special variant of the switch, please do not
hesitate to contact us. Maybe the type of switch you are
looking for is among our many special designs. If not, we
can also supply customized designs. In this case minimum
quantities apply.
*  No index

Parameter Code Version


IP rating: contacts / terminals IP40/20
Actuator style

►► Pushbutton (standard) b

►► Series S814
►► Contact material * / 10 S814
Ag/Au
►► Actuating and release force * / 40

Terminal style

►► M3 screws with saddle clamp --- *

Dimensions in mm / Subject to technical alterations


11

Dimension and circuit diagrams   Series S814

●● Dimensions S814 b  Form Za SPDT-DB switch Circuit diagram

28±0.15 16.3±0.2 3 4
5.5 5.5
3.2±0.1

1 2

12.6
8.5
10

16.5
31
33.7

7
Free position
9.2 Mount / ganging
19.2 Torque 1.0 Nm max. S814
Terminal screws Form Za SPDT-DB switch with silver or gold
M3 with saddle clamp contacts, rigid contact bridge and wiping
Torque 0.9 Nm max. action
22

S814  b Pushbutton (standard)


Note: 
36
●● Single and multiple-wire conductors with wire gauges
AWG 18 ... 12 (0.75 mm² ... 2.5 mm²) can be clamped with-
out wire end ferrules. If a ferrule is used the maximum wire
gauge is AWG 14 (1.5 mm² max.)
●● Max. 2 conductors with the same wire gauge can be
clamped per terminal
●● IP rating: contacts IP00 / terminals IP40

Plunger travelling full length throug the switch   Series S814

A special feature of the S814 is its plunger which, on actuation travels the full-length of the switch.
This makes them ideally suited for applications where the switching element must be in line with
the perpendicular line of actuation. It is thereby possible to mount two S814 switches on top of
each other and trigger two switching operations with only one actuation, like a full-blown dual
changeover switch.
For this reason they are especially suited for use as emitter switches for meters and counters, for
use with indicating devices, master controllers and control units and, last but not least, as
switching elements for membrane switches.

Actuator style and positions   Series S814

●● S814 Pushbutton ( standard)  b

Actuator positions Pushbutton (standard)  b


Dimension in mm
Free position 12.6 ± 0.2
Operating position 11.6 ± 0.2
Release position 12.1 ± 0.2
Total travel position 10.6
Movement differential
0.5
(between operating and
(typical)
release position)

Note:
Actuator must not be pushed beyond total travel position.
Data is valid for new switches..

Dimensions in mm / Subject to technical alterations


12

S820  Ordering code Series S820

Example:   S820 b7/40 L 
Series, Contact configuration    Special design, optional
S820 Blowouts L
Form Zb SPDT-DB with positive opening operation
and galvanically isolated contact bridges   Actuating and release force
Standard *
Actuator styles 
Stronger reset spring 40
Actuator style Mounting style
b Pushbutton No mounting brackets
e Roller lever No mounting brackets
a Roller lever With mounting brackets

Contact material 
Note:
7 Silver (Fixed contact AgCu3 / contact bridge AgSnO2)
This catalogue shows only stock items. For some variants
minimum quantities apply. Please ask for the conditions.
Special variant:
If you need a special variant of the switch, please do not
hesitate to contact us. Maybe the type of switch you are
looking for is among our many special designs. If not, we
can also supply customized designs. In this case minimum
quantities apply.
*  No index

Parameter Code Version


IP rating: contacts / terminals IP40/20
Actuator styles

►► Pushbutton (standard),
b
no mounting brackets

►► Roller lever,
e
no mounting brackets

►► Roller lever,
a
with mounting brackets

►► Series S820
S820
►► Contact material 7 Ag
►► Actuating and release force 40
►► Blowouts (special design) L

Terminal style

►► M3 screws with saddle clamp --- *

Dimensions in mm / Subject to technical alterations


13

Dimension and circuit diagrams   Series S820

●● Dimensions S820 b Form Zb SPDT Circuit diagram

+3 -4 3 4
-1 +2
1 2
Front mount (M3)
42 Torque 0.9 Nm max.
28 Side mount / ganging
8.4 Torque 1.0 Nm max.
13

2.2
M3 9 ±0.15

PES 4KV/3
3.5
max. 5

44.7
4.1

N N S N
S820
N N S N Form Zb SPDT-DB with silver contacts,
positive opening operation and galvanic-
ally isolated contact bridges
36
S820  b Pushbutton (standard)
50 12 max.

8 blowout magnets (optional)


for increased DC breaking capacity

Screwable thread length of Free position


fastening screw

Actuator styles and positions   Series S820

●● S820 Pushbutton ( standard)  b

Actuator positions Pushbutton (standard)  b


Dimension in mm
Free position 9.0 ± 0.15
Operating position 6.0 ± 0.35
PES 4KV/3
Release position 8.0 ± 0.35
Total positive opening travel 5.2
Total travel position 5.0
Movement differential
2.0
(between operating and
(typical)
release position)

Note:  To ensure proper operation of the positive opening function it is


necessary to depress the plunger to the point of total positive opening travel.
However, it must not be pushed beyond total travel position.
Data is valid for new switches.

●● S820 Roller lever  e , a


7.1 6.8
Actuator positions Roller lever  e , a
8 Dimension in mm
Free position 20.9 ± 0.35
Operating position 15.6 ± 0.5
Release position 18.85 ± 0.5
Total positive opening travel 13.1
Total travel position 12.9
PES 4KV/3
Movement differential
3.25
(between operating and
(typical)
release position)

Note:  To ensure proper operation of the positive opening function it is


necessary to depress the plunger to the point of total positive opening travel.
However, it must not be pushed beyond total travel position.
Data is valid for new switches.

Dimensions in mm / Subject to technical alterations


14

Mechanical fastening  Front mount, ganging Series S820

Front mount Ganging


●● No mounting brackets:  By way of the nut retainers (M3) that are ●● Through the transversal bore holes with 4 mm screws or bolts.
inserted in the housing of the switch. Torque 0.9 Nm max. Torque 1.0 Nm  max.
●● With mounting brackets:  By way of M3 screws for all actuator styles. ●● Alternatively DUO clips or retaining rings can be used.
Torque 0.9 Nm max.

Actuators without mounting brackets   Actuators with mounting brackets 

●● Pushbutton (standard) no mounting brackets  style b ●● Roller lever with mounting brackets style a
max.

max.
Front mount
12

12

9
M3

3,5
Max. screwable thread length
of fastening screw

1
28 58
5 max.

42 67
max.

Ganging
12

(side mount)

4.1
3.5

28

●● Roller lever without mounting brackets style e


max.
12

3.5

4.1
28

Terminal style  M3 screws Series S820

●● M3 screws with saddle clamp (standard)  style *

PES 4KV/3
44.7

3 1 2 4 Note: 
12 max. ●● Single and multiple-wire conductors with wire gauges AWG 18 ... 12
(0.75 mm² ... 2.5 mm²) can be clamped without wire end ferrules. If a ferrule is used
+3 -4
-1 +2 the maximum wire gauge is AWG 14 (1.5 mm² max.)
●● Max. 2 conductors with the same wire gauge can be clamped per terminal.
50 *  No index ●● Tightening torque of terminal screws should be 0.9 Nm max.
●● IP rating: contacts IP00 / terminals IP40

Dimensions in mm / Subject to technical alterations


15

Instruction  on when to use a roller lever (examples) Series S820

Snap-action switches are designed for actuation with and without roller lever. A roller lever is required,
if the direction of actuation deviates more than ±15° from the perpendicular line.

●● Switch with roller lever actuated by cam disk ●● Switch with roller lever actuated by trigger cam

Total travel pos. + 0.2 ... 0.3


Free pos. + 0.2 ... 0.3

Total travel pos. + 0.2 ... 0.3


Free pos. + 0.2 ... 0.3
≥4

° ≥40
≥40 °

Stroke 5 min.
Stroke 7 max. 1 max.
Stroke 5 min.
Stroke 7 max. 1 max.

Cam disc  Clearance  


40 mm 3.6 mm
60 mm 0 mm
100 mm (max.) 0 mm

Mounting and safety instructions, environmental conditions   Series S800/S804/S814/S820

Mounting instructions: Non-permissible environmental conditions:


●● Snap-action switches should be mounted by qualified professional ●● Cleaning agents, adhesives, solvents, or screw-retaining varnish must be
staff only. compatible with polycarbonate (S800, S804, S814 series) and polyether-
●● Observe the required clearance and creepage distances. This is also sulfone (S820 series), respectively. Never use chemicals not compat-
true for connected wires. ible with polycarbonate for S800, S804 and S814 series switches and
●● It is necessary to use insulating plates when ganging or mounting polyethersulfone for S820 series switches, respectively.
switches on uninsulated surfaces. ●● Using chemicals which are not compatible can result in cracks, deforma-
●● The switches can be mounted in any desired position. tion, breakage and dissolution of the housing or complete destruction
●● When mounting the switches mechanically make sure to have of the switch.
2 fastening elements (e.g. screws).
●● Only use adequate fastening elements such as cylinder head or Safety instructions:
collar screws or DUO-clips, including washers. When fastening make ●● Be sure to make visual inspections regularly.
sure not to exceed the maximum tightening torque.
●● Improper handling of the switch, e. g. when hitting the floor with some
●● When mounting switches with mounting brackets make sure that the impact, can result in breakage, visible cracks and deformation.
mounting surface is level.
●● Avoid tilting the screw when mounting and prevent mechanical
Defective parts must be replaced immediately!
tension on the housing.
●● The actuator may not be pre-tensioned when in the free position.
When actuated, the actuator should travel well beyond the operating
position, for at least 50% of the predefined overtravel, all the way to
total travel position.
●● To ensure the proper function of the positive opening operation it is Standards   Series S800/S804/S814/S820
necessary to depress the plunger to the end point of the positive
opening travel. ●● IEC 60947-5-1:  Low-voltage switchgear and controlgear,
●● To prevent mechanical destruction of the switch, make sure that actua- Part 5-1: Control circuit devices and switching elements - Electrome-
tion of the switch does not exceed the specified total travel position. chanical control circuit devices
Avoid using the switch as a mechanical end stop. ●● IEC 60947-5-1, Annex K:  Special requirements for control switches
●● High-impact actuation of the switch can also have a negative effect on with direct opening action
its mechanical life. ●● UL508:  Industrial control equipment
●● When securing stripped wire ends in the terminal clamp, make sure the ●● IEC 60529:  Degrees of protection provided by enclosures (IP Code)
wire insulation is flush with the clamp. ●● UL 94V-0:  Flammability Standard
●● Make sure that strain relief of the connected leads functions. ●● DIN 41636-6:  Dimensions correspond to type F as defined by the
●● Prevent a transfer of forces to the switch terminals. standard
●● When using versions with blowout magnets observe the right polarity, ●● DIN 40050-9:  Road vehicles; degrees of protection (IP code); protec-
see circuit diagram at the bottom of the switch. tion against foreign objects; water and contact; electrical equipment
●● DIN 46244:  Tabs for receptacles

Dimensions in mm / Subject to technical alterations


Schaltbau GmbH with compliments:

For detailed information on our products


and services visit our website –
or give us a call!

Schaltbau GmbH
Hollerithstrasse 5
81829 Munich
Germany
can c can c
you you
RoHS
Phone +49 89 9 30 05-0

ou

ou
Quality

Quality
nt on

nt on
2011/65/EC
Fax +49 89 9 30 05-350 Sc
h a lt b a u
Sc
h a lt b a u

Internet www.schaltbau-gmbh.com
Schaltbau GmbH The production facilities Certified to Certified to
e-Mail [email protected] manufactures in of Schaltbau GmbH have DIN EN ISO 14001 DIN EN ISO 9001
compliance been IRIS certified since since 2002. For the most since 1994. For the most
with RoHS. 2008. recent certificate visit recent certificate visit
our website. our website.

Electrical Components and Systems for


Railway Engineering and Industrial Applications

Connectors Connectors manufactured to industry standards


Connectors to suit the special requirements of
communications engineering (MIL connectors)
Charging connectors for battery-powered
machines and systems
Connectors for railway engineering,
including UIC connectors
Special connectors to suit customer requirements

Snap-action switches Snap-action switches with positive opening operation


Snap-action switches with self-cleaning contacts
Enabling switches
Special switches to suit customer requirements

Contactors Single and multi-pole DC contactors


High-voltage AC/DC contactors
Contactors for battery powered vehicles and power supplies
Contactors for railway applications
Terminal bolts and fuse holders
DC emergency disconnect switches
Special contactors to suit customer requirements

Electrics for rolling stock Equipment for driver's cab


Equipment for passenger use
High-voltage switchgear
High-voltage heaters
High-voltage roof equipment
Equipment for electric brakes
Design and engineering of train electrics
to customer requirements

We reserve the right to make technical alterations without prior notice.


For updated product information visit www.schaltbau-gmbh.com
D2074/1512/1.0 Printed in Germany Issued 03-2016