0% found this document useful (0 votes)
78 views44 pages

07 - PAC Meter

This document discusses a Sentron power management device called the PAC3200. It provides transparency into power flows from the infeed to the consumer with precise detection of consumption data. It can integrate effortlessly into power management or process control systems. The PAC3200 offers high measurement accuracy and can measure over 50 electrical parameters. It is suitable for use in a wide variety of industrial and commercial applications.

Uploaded by

Mukesh Sahu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
78 views44 pages

07 - PAC Meter

This document discusses a Sentron power management device called the PAC3200. It provides transparency into power flows from the infeed to the consumer with precise detection of consumption data. It can integrate effortlessly into power management or process control systems. The PAC3200 offers high measurement accuracy and can measure over 50 electrical parameters. It is suitable for use in a wide variety of industrial and commercial applications.

Uploaded by

Mukesh Sahu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 44

Areas of use

Sentron
Benefits

Highlights

Functions

Power Management
Technical data

Installations /
Assembly

Configuration

System
Integration

Systemintegrati
on

Ordering
information
Need for Power Management –
World-Shaking Issues
D I A
Dwindling oil supplies
-I N
Global heating

A I N
I T R
S

Rising power costs


D I A
Emission taxes

- I N
A I N
I T R
S
More efficient power utilization against rising power costs
and for our environment 3C – Combat Climate Change
SENTRON PAC3200 Industry Sector
Slide 2/48 A&D/BD - CD 2008 - Subject to modifications
Customer Concerns

D I A
§ Increasing cost pressure
- I N
A I N
I T R
à Solution: Continuous reduction of operating costs
S
§ High power costs through rising power prices

à Solution: Shifting high-load to low-load times,

D I A
optimizing power costs, raising power awareness

- I N
Reduction of operating costs through active power management
A I N
§
T R
Reduction of power procurement and operating costs by 5-20% (typical)
§
SI (typical)
Short ROI of < 2 years

SENTRON PAC3200 Industry Sector


Slide 3/48 A&D/BD - CD 2008 - Subject to modifications
Power Management Reveals Saving Potentials

D I A
- I N
A I N
I T R
S

D I A
- I N
A I N
I T R
S
Optimization of operating costs with significant saving potential
through transparency and allocation of consumption costs.
SENTRON PAC3200 Industry Sector
Slide 4/48 A&D/BD - CD 2008 - Subject to modifications
SENTRON Power Management

D I A
Areas of use
- I N
Benefits
A I N
Highlights
I T
“ You cannot manage
R what you cannot measure”
Functions
S
Technical data

Installations /
Assembly

Configuration

System
D I A
Integration

- I N
Systemintegrati
on
A
“ You cannot manageI N EFFECTIVLEY
Ordering
I T R
information
S what
you cannot measure RELIABLY”
SENTRON PAC3200 Industry Sector
Slide 5/48 A&D/BD - CD 2008 - Subject to modifications
Market Requirements

D I A
- I N
I N
Requirements in the field of low-voltage
A
power distribution:
-
T R
Transparency of power flows
I
S
from the infeed to the consumer
- Precise detection of all consumption
data throughout the entire power distribution
- Effortless integration in power management
or process control systems
D I A
-
I N
Clearly structured display of the values directly
-
A I N
on the measuring point with sound readability

I T R
S
Power Monitoring Device
SENTRON PAC3200
SENTRON PAC3200 Industry Sector
Slide 6/48 A&D/BD - CD 2008 - Subject to modifications
SENTRON PAC3200
D I A
- I N
A I N
I T R
S

D I A
- I N
A I N
I T R
S

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


D I A
- I N
SENTRON
A I N PAC3200
IT R
S
Areas of use
Highlights
D I A
Functions
- I N
I N
Technical data
A
ITR
Installations / Assembly

S Configuration
System Integration
Systemintegration
Ordering information
Benefits
SENTRON PAC3200 à at home in every sector
Applications

D I A
Infrastructure &
- I N
institutions
A I N
ITR
n Hospitals
n Airports
Industry
n Train stations
n Water works
S nProcess industry
nOil & gas
n Sewage treatment plants
nChemical & pharmaceutical
n Waste disposal plants
nMetal
n Schools / universities
nPaper
n Official buildings
n Production industry
n Etc.

D I A nMechanical engineering
nMetal

Trade & - I N nFood, beverages & tobacco


nSemiconductors

commerce
A I N n Commercial businesses
n Etc.

n Office buildings
I T R
n Shopping malls
n Multi-story buildings
n Gas stations
S
n Restaurants
n Craft businesses
n Etc.

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


D I A
- I N
SENTRON
A I N PAC3200
IT R
S
Areas of use
Highlights
D I A
Functions
- I N
I N
Technical data
A
ITR
Installations / Assembly

S Configuration
System Integration
Systemintegration
Ordering information
Benefits
SENTRON PAC3200 à high performance, low cost!
Highlights

D I A
I
§ Measurement of over 50 parameters such as VPH-N / VPH-PH /
Amps / VA, ±W, ± kvar / PF / freq. THD with min., max.- N
and average values
A I N
I T R
§ Can be used for single-phase measurements and also
S
multi-phase measurements in 3 and 4-wire networks
§ High measuring accuracy for work, Class 0.5 S
acc. to IEC62053-22
§ Current measurement via x/1A or x/5A current transformer
§ Can be connected directly to industrial networks up to
D I A
I N
3~690/400V *) AC (CATIII), higher voltages via voltage transformer
§ Large graphic LCD display with user friendly-navigation via function keys
§ Compact yet Powerful : Depth only A
I N
§ IP65 on the front throughS
R
IT seal
standard
51mm

*) 500V max. (Uph-ph) for variants with low voltage DC power supply (7KM2111-1BA00-3AA0)

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à high performance, low cost!
Highlights

D I A
I N
§ 1x Digital Input / 1x Digital Output as Standard feature
-
§ Import / Export of Energy Parameters
A I N
§ Monitoring of Limit Values
I T R
§ Integrated Ethernet interface Sfor network connection.
§ Supports SEAbus over Ethernet or Modbus TCP protocol
via the integrated Ethernet interface.
§ Plug-in extension modules such as
§ PAC PROFIBUS DP with PROFIBUS DPV1 protocol
D I A
- I
§ PAC RS485 with Modbus RTU or SEAbus protocolN
A I N
§ Coverage of all typical power supplies with only 2 models:

I T R
§ Wide range AC/DC power supply: 95...240VAC ±10% / 50/60Hz &
S 110...340VDC ±10%
§ Low voltage DC power supply: 22.....65VDC ±10%
§ Free configuration software included in the packaging of each meter.

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à certified for USA and Canada
Certificates

D I A
- I N
§ IP65 on the front
I N
A § Device class PICQ
I T R § File number: E314880
S § Over voltage category III
§ UL certified for voltages up
to 600V *)

I A
§ UL 61010-1, 2nd Ed.
D
- I N
Safety of Electrical Equipment for Measure-
ment, Control and Laboratory Use

A I N Part 1: General Requirements

I T R § CAN/CSA-C22.2 NO. 61010-1-04, 2nd Ed.


S Safety of Electrical Equipment for Measure-
ment, Control and Laboratory Use
*) 500V max. (Uph-ph) for variants with low voltage
DC power supply (7KM2111-1BA00-3AA0)

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


D I A
- I N
SENTRON
A I N PAC3200
IT R
S
Areas of use
Highlights
D I A
Functions
- I N
I N
Technical data
A
ITR
Installations / Assembly

S Configuration
System Integration
Systemintegration
Ordering information
Benefits
SENTRON PAC3200 à accurate, transp. and reliable!
Functions

D I A
Accurate energy measurement
I N
§ Meets the precision requirements of the-0.5S class in compliance with
A
IEC62053-22 for static meters for I N
active energy
I T R
Transparency in energy S matters
§ 10 energy meters for active, reactive and apparent energy constantly monitor
energy consumption in the system for
import and export, broken down into high and low tariffs
§ SENTRON PAC3200 supplies the necessary average active and reactive
D I
power demand values for the creation of load profilesA
Protection against unauthorized access - I N
A I N
§ Energy and parameter data can be protected against unauthorized access by

I T R
the integral password protection
S are recorded by a configuration counter and can
§ Changes to parameterization
be read out via an interface

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à supplies the details!
Functions

D I A
Instantaneous rms values
- I N
Voltage

A I N
phase-phase / phase-neutral ●
Current

I T
Apparent, active and reactive power R per phase
per phase and total


Power factor
Frequency
S per phase and total ●

THD for voltage and current per Phase ●
Min.- / max.- values ●
Average values over all phases ●
Energy measurement
Active energy
D I A
import / export; high / low tariff ●/●
Reactive energy
I N
inductive / capacitive ; high / low tariff

-
●/●

Apparent energy

A I N
high / low tariff
Active and reactive power demand values per measuring period ●

ITR
Amount of measuring periods to store 1

S
Measuring period interval selectable
Min.- / max.- values for power within the measuring period
Operating hours meter (load)
1…60 min.



Universal counter (e.g. to count the energy pulses of a external kWh / kvarh meter) ●

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à monitors, communicates - and more!
Functions

D I A
Accuracy
- I N
Voltage

A I N ±0,3%
Current
Power

I T R ±0,2%
±0,5%
Active energy

Reactive energy
S Class 0,5S according
to IEC62053-22
Class 2 according
to IEC62053-23
Monitoring functions
Limit monitoring up to 6 limits
Simple logical operations possible for limits ●
Unbalance
Communication
voltage and current

D I A ●

Ethernet
Protocols
- I
integrated
N 10 Mbit/s
SEAbus TCP or

Profibus DP
A I Nvia optional extension module
Modbus TCP

ITR ●
Modbus RTU / SEAbus via optional extension module
In-/Outputs
Digital input
Digital output
S multifunctional
multifunctional
1
1
Miscellaneous
Password protection ●
Certifications USA (UL) and Kanada (CSA) ●

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à clearly arranged!
Functions

D I A
Displays in plain text
I N
§ Large, full graphics LCD with backlit and-plain text displays are easy to read even
A
at a distance and in poor lighting I N
conditions
I T R
S
adaptable on
menu-assisted
the lighting
operation
conditions

D I A
- I N
Plain text

A I N
4 function
Direct navigation in
the measurement
displays

§ To adjust the display S I T R keys

for ambient conditions, it is possible to set contrast,


menus

brightness and whether the screen should be displayed with inverted colors.
§ Programmable dimming or blanking time to reduce energy and to increase
backlight lifetime.

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à user-friendly!
Functions

D I A
Operation in a choice of languages
- I N
in English, German, Portuguese, A I N
§ Intuitive, menu-assisted user guidance via function keys and plain text displays
Turkish, Spanish, Italian, French, Chinese
and Russian.
I T R
S 8 selectable languages
delivered in the device,
additional languages can
be downloaded via
configuration software

D I A
- I N
A I N 4 function
keys Direct navigation in the

I T R measurement menus

S
§ Direct navigation in the measurement menus for practiced users
the arrow keys can be used to move directly to the next measurement display

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à 0100011110000011!
Functions

D I A
Multi-functional digital input and output
- I N
§ Digital input:
A I N
I T R
§ Counting input for kWh, kvarh – impulses (S0)

S
§ Status monitoring e.g. for switching devices
§ HT/LT - tariff switching 1xDI / 1xDO

§ Synchronization of measuring periods

D I A
- I N
A I N
§ Digital output:
I T R
S
§ Pulse output for kWh, kvarh – impulses (S0)
§ Alarm output for signaling limit violations
§ Operating status display of the SENTRON PAC3200
§ Display of direction of rotation
§ Switching output to remote control via system software

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à everything under control!
Functions

D I A
Monitoring and service
- I N
§ Limit monitoring:
A I N
I T R
§ Monitoring of up to 6 limits for overrange and undershoot

S
§ Voltages, currents, power, power factors, THD,
frequency or asymmetry U/I can be monitored
§ Delay time and hysteresis can be set
§ Logical AND / OR operations possible for limits
§ Result of logical operation can itself be used like

I
the limits to trigger a wide variety of actions
D A
§ Actions to be triggered in case of limit violation can be programmed
§ Switching of digital output
- I N
§ Communication via interfaces
A I N
T R
§ Universal meter for adding up all events
I
S
§ Monitoring of phase symmetry for voltage and current in order to avoid unbalanced
loads
§ Operating hours meter for monitoring the running time of connected consumers
such as motors, pumps, machines, etc.

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à perfect communication!
Functions

D I A
I N
Effective communication via Ethernet or serial
-
Interface modules

A N
I§ 10 Mbit/s Ethernet interface provided as standard
I T R for network communication. IP-Address, subnet
S mask and gateway can be parameterized from
front of device or via configuration software
10Base-T
§ Supports SEAbus over Ethernet or Modbus TCP

I A
protocol; configurable on the device or via confi-
D
- I N
guration software.
§ Mounting
N location for extension modules such as
AI § SENTRON PAC PROFIBUS DP
I T R
S § SENTRON PAC RS485
for serial communication (RS485)
Module
mounting
location

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à perfect communication!
Functions

D I A
Effective communication via PROFIBUS DPV1
- I N
PAC PROFIBUS DP extension module IN
T R A
§
configuration softwareS
I
Can be parameterized from front of device or via Expansion-Module
PAC PROFIBUS DP

§ Simple integration via GSD file


§ Measurement parameters selectable via GSD file
§ Baud rates of 9.6kBit/s up to 12 MBit/s +
§ 9-pole sub-D plug connection in compliance
D I A =

with IEC 61158


- I N
§ I
No external auxiliary power necessary
A N
§
I T R
Status display LED on module Module mounting
Expansion-
Module

§ SDPV1
Protocol: PPROFIBUS
location on
PAC3200
installed

Synchronous and Asynchronous data transmission


including parameter setting.

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à perfect communication!
Functions

D I A
Effective communication via RS485 Interface
- I N
PAC RS485 extension module AI
N
T
Can be parameterizedIfrom
Rfront of
§
S software
device or via configuration
Expansion-Module
PAC RS485

§ Supports Modbus RTU and SEAbus


protocol (protocols swichable)
§ Plug and Play +
§ Baud rates of 4,8 / 9,6 / 19,2 and 38,4 kBd
D I A =

§ 6-pole connection via screw terminal


- I N
§
A I N
No external auxiliary power necessary
§
I T R
Status display LED on module Module mounting
Expansion-
Module

S location on
PAC3200
installed

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


D I A
- I N
SENTRON
A I N PAC3200
IT R
S
Areas of use
Highlights
D I A
Functions
- I N
I N
Technical data
A
ITR
Installations / Assembly

S Configuration
System Integration
Systemintegration
Ordering information
Benefits
SENTRON PAC3200 à high-level technology!
Technical data

D I A
Technical data
- I N
I N
2 quadrant (import) / 4 quadrant (import and export) measurement

A
4Q

ITR
Measurement in single / multi phase systems 1ph, 2ph or 3ph
Suitable for the following systems TN, TT, IT
Sampling
S
Voltage measurement (direct connection up to max. - delta/wye - without VT’s)
Wide range AC/DC pow er supply 7KM2112-0BA00-3AA0
zero blind

690V / 400V
CATIII
Low voltage DC pow er supply 7KM2111-1BA00-3AA0 500V / 289V
CATIII
Current measurement x/1A and x/5A
Auxiliary voltage
Wide range AC/DC pow er supply 7KM2112-0BA00-3AA0

D I A 95-240V AC (±10%)

Low voltage DC pow er supply

- I N
7KM2111-1BA00-3AA0
140-340V DC (±10%)
22-65V DC (±10%)
Dimensions

A I Nl x w in mm
installation depth without module (mm)
96x96
51

ITR
installation depth with module (mm) 73

S
Protection front side IP65
back side IP20
Operating temperature °C -5 … +55
Display type graphics LCD
with backlit
resolution (pixel) 128x96
Language for text outputs multi-language

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à small and slim!
Dimensions

D I A
- I N
A I N
I T R
S

D I A
- I N
A I N
I T R
S
Dimensions in mm

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à easy to connect!
Terminal connections

D I A
-
No.I N Terminal Function

A I N
(1) IL1 k Phase current, Ia, input

I T R (2)
(3)
IL1
IL2
l
k
Phase current, Ia, output
Phase current, Ib, input

S (4)
(5)
IL2
IL3
l
k
Phase current, Ib, output
Phase current, Ic, input
(6) IL3 l Phase current, Ic, output
(7) V1 Phase voltage Va
(8) V2 Phase voltage Vb
(9) V3 Phase voltage Vc
(10)
(11)
VN
L/+

D I A AC:
Neutral conductor Vn
Connection: Conductor (Ph)

- I
(12) N DC: Connection: +
N/- AC: Con.: Neutral conductor (N)

A I N
(13)
DC:
Functional ground
Connection: -

I T R (14) DI - Digital input -

S (15)
(16)
(17)
DI
DO -
DO +
+ Digital input +
Digital output -
Digital output +

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à fits into any network!
Wiring diagrams

D I A
Three-phase measuring, four conductors, unbalanced
load, without voltage transformers, with three current
transformers
- I N
Three-phase measuring, four conductors, unbalanced
load, with voltage transformers, with three current

Connection type 3P4W

A I N transformers
Connection type 3P4W

I T R
S

Three-phase measuring, four conductors, balanced load,


D I A
Three-phase measuring, four conductors, balanced load,
without voltage transformer, with one current
transformer
I N
with voltage transformer, with one current transformer

-
Connection type 3P4WB

A I N Connection type 3P4WB

I T R
S
* Fuses to be provided by the customer.
** Connection for supply voltage

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à fits into any network!
Wiring diagrams

D I A
Three-phase measuring, three conductors, unbalanced
load, without voltage transformers, with three current
I N
Three-phase measuring, three conductors, unbalanced

-
load, with voltage transformers, with three current
transformers
Connection type 3P3W

A I N transformers
Connection type 3P3W

I T R
S

Three-phase measuring, three conductors, unbalanced


load, without voltage transformers, with two current I A
Three-phase measuring, three conductors, unbalanced

D
load, with voltage transformers, with two current
transformers

I N
transformers

-
Connection type 3P3W

A I N Connection type 3P3W

I T R
S
* Fuses to be provided by the customer.
** Connection for supply voltage

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à fits into any network!
Wiring diagrams

D I A
Three-phase measuring, four conductors, unbalanced
load, with voltage transformers, with three current
transformers
- I N
* Fuses to be provided by the customer.
** Connection for supply voltage
Connection type 3P3W

A I N
I T R
S

Three-phase measuring, three conductors, balanced


D I A
Three-phase measuring, three conductors, balanced
load, without voltage transformers, with one current
transformer
I N
load, with voltage transformers, with one current

-
transformer
Connection type 3P3WB

A I N Connection type 3P3WB

I T R
S

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à fits into any network!
Wiring diagrams

D I A
Two-phase measuring, three conductors, unbalanced
load, without voltage transformers, with two current
transformers
- I N
Single-phase measuring, two conductors, without
voltage transformers, with one current transformer

Connection type 3P4W

A I N Connection type 1P2W

I T R
S

* Fuses to be provided by the customer.


** Connection for supply voltage

D I A
- I N
A I N
I T R
S

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


D I A
- I N
SENTRON
A I N PAC3200
IT R
S
Areas of use
Highlights
D I A
Functions
- I N
I N
Technical data
A
ITR
Installations / Assembly

S Configuration
System Integration
Systemintegration
Ordering information
Benefits
SENTRON PAC3200 à quickly installed!
No-tool installation

D I A
Quick, simple assembly
- I N
I N
§ Fast, no-tool assembly in the control
A
I
combination slot-in mountT R
cabinet door using a sophisticated

S
§ Seal integrated as standard

I A
§ The screws integrated into the combi-
D
- I N
nation slot-in mount can be used to
increase contact pressure and thus

A I N improve the degree of protection to

I T R IP65
S
§ Trouble-free assembly of adjacent devices thanks to easy-to-use combination
mount and low installation depth of just 51 mm (73 mm with extension module)

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à easy to connect!
Installation

D I A
Trouble-free, convenient installation
- I N Voltage and

A N
§ Connections for measuring voltage, measuring
current and the auxiliary supply I
current inputs;
auxiliary supply

I
§ Available multi-range powerT R
supply models
§ Wide range AC/DCS power supply:
95...240VAC ±10% / 50/60Hz & 110...340VDC ±10%
§ Low voltage DC power supply: 22…65VDC ±10%
§ Generous provision of screw terminals
throughout the device
§ Conductor cross-sections of 0.5 to 4 mm² D I A
or AWG 20 to 14 connectable
- I N
A I N
§ Connections for digital input, digital output

I T R and functional ground

S § Removable terminal block


§ Conductor cross-sections of
Terminal block 0.2 to 2.5 mm² or AWG 24 to 18
for DI / DO
connectable

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


D I A
- I N
SENTRON
A I N PAC3200
IT R
S
Areas of use
Highlights
D I A
Functions
- I N
I N
Technical data
A
ITR
Installations / Assembly

S Configuration
System Integration
Systemintegration
Ordering information
Benefits
SENTRON PAC3200 à click and go!
Device configuration

D I A
Configuration via Point-to-Point connection
- I N
N
§ Direct connection between PC and PAC3200
via standard Cross Over Cable AI
I T
§ No special networking skills R
necessary
Sfor SENTRON
§ No administrator rights
Point-to-Point
powerconfig required (except during installation Connection
of the software)

Configuration via Ethernet-Network


D I A
-
§ Communication via switch or Hub within theI N
I N
network; standard patch cable sufficient
A
I T R
§ Easy-to-use search function for the detection of
S
all PAC3200s within a local Ethernet network
§ Establishing a connection to a device and
displaying the connection status in the software Network-
connection
is simple

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


D I A
- I N
SENTRON
A I N PAC3200
IT R
S
Areas of use
Highlights
D I A
Functions
- I N
I N
Technical data
A
ITR
Installations / Assembly

S Configuration
System Integration
Systemintegration
Ordering information
Benefits
SENTRON PAC3200 à short delivery time!
Ordering information for power monitoring devices

D I A
SENTRON
- I N
Wide range AC/DC power supply; compression terminals
PAC3200
A I N
§ 95…240VAC ±10% / 110…340VDC ±10%
§ x/1A or x/5A
I T R
§ max. 3~ 690/400V; 45...65 Hz
S MLFB: 7KM2112-0BA00-3AA0
SENTRON Low voltage DC power supply; compression terminals
PAC3200 § 22…65VDC ±10%
§ x/1A or x/5A
D I A
§ max. 3~ 500/289V; 45...65 Hz
- I N
MLFB: 7KM2111-1BA00-3AA0

A I N
SENTRON WideR
PAC3200 T
S§§I x/1A
range AC/DC power supply; ring lug terminals
95…240VAC ±10% / 110…340VDC ±10%
or x/5A
§ max. 3~ 690/400V; 45...65 Hz
MLFB: 7KM2112-0BA00-2AA0

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à short delivery time!
Ordering information for expansion modules

D I A
- I N
ExpansionN
V1A
DPR
I module PAC PROFIBUS DP

In
T
S 9,6kBit/s bis 12 MBit/s
n

MLFB: 7KM9300-0AB00-0AA0

D I A
- I N
Expansion module PAC RS485
n
A I N
Modbus RTU / SEAbus (switchable)
4,8R
T
S I
n / 9,6 / 19,2 / 38,4 KBd

MLFB: 7KM9300-0AM00-0AA0

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


D I A
- I N
SENTRON
A I N PAC3200
IT R
S
Areas of use
Highlights
D I A
Functions
- I N
I N
Technical data
A
ITR
Installations / Assembly

S Configuration
System Integration
Systemintegration
Ordering information
Benefits
SENTRON PAC3200 à saves time and money!
Benefits

D I A
measurement tasks - thus saving storage - N
§ A wide range of functions means that only one device
I acquisition costs.
and
is required for a variety of

A I N
§ Quick, simple assembly saves installation
§ Saves costs and space I asT
R costs.

*) S it can be connected to power distribution systems of up


to 690V without a voltage transformer. No expensive voltage transformer is
required.
§ Comprehensive and precise energy measurement forms the basis for identifying
savings potential in the system.
§ The SENTRON PAC3200's wide variety of measuring and monitoring functions
D I A
I N
contribute indirectly to better protection against failure as faults are recognized
earlier. -
A I N
§ With its technical design, various approvals and certifications, e.g. UL and CSA
I T R
for USA and Canada, as well as the support of 9 languages, the SENTRON
PAC3200 can be used worldwide. S
§ A shallow mounting depth of only 51 mm saves space.
*) 500V max. (Uph-ph) for variants with low voltage DC power supply (7KM2111-1BA00-3AA0)

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à saves time and money!
Benefits

D I A
-
conditions and opens up a wider application
N
§ A large, illuminated graphic display guarantees good
Iarea for the device.
reading even in poor light

A I N
I T R
§ The multilingual, intuitive operation the PAC3200 enables quick initial start-up and

S
easy daily operation, saving both time and money.
§ The network capable Ethernet interface, which comes standard without additional
costs, reduces system integration costs. In addition, the wide bandwidth increases
the system performance significantly.

D I A
§ SENTRON powerconfig, which is free of charge, makes it easier to configure the
devices. This leads to a considerable reduction in time, when multiple PAC3200
have to be setup.
- I N
I N
§ The expansion module PAC PROFIBUS DP or PAC RS485 provides an easy
A
T R
integration in automation or power management systems, e.g. SIMATIC WinCC
I
S
powerrate or SIMATIC PCS 7 powerrate and thereby saves time and
implementation costs.

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


D I A
- I N
SENTRON
A I N PAC3200
I T R Thank you
S

D I A
- I N
A I N
I T R
S