IP 10 IDU Installation Rev B 01 PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 33

FibeAir® IP-10

IDU
Installation
Guide

Part ID: BM-0237-0


Doc ID: DOC-00018797 Rev b.01
January 2009

1-1
Notice
This document contains information that is proprietary to Ceragon Networks Ltd.
No part of this publication may be reproduced, modified, or distributed without prior written authorization of
Ceragon Networks Ltd.
This document is provided as is, without warranty of any kind.

Registered TradeMarks
®
Ceragon Networks is a registered trademark of Ceragon Networks Ltd.
®
FibeAir is a registered trademark of Ceragon Networks Ltd.
®
CeraView is a registered trademark of Ceragon Networks Ltd.
Other names mentioned in this publication are owned by their respective holders.

TradeMarks
TM TM TM TM TM TM TM
CeraMap , PolyView , EncryptAir , ConfigAir , CeraMon , EtherAir , and MicroWave Fiber , are
trademarks of Ceragon Networks Ltd.
Other names mentioned in this publication are owned by their respective holders.

Statement of Conditions
The information contained in this document is subject to change without notice.
Ceragon Networks Ltd. shall not be liable for errors contained herein or for incidental or consequential damage
in connection with the furnishing, performance, or use of this document or equipment supplied with it.

Information to User
Any changes or modifications of equipment not expressly approved by the manufacturer could void the user’s
authority to operate the equipment and the warranty for such equipment.
Copyright © 2008 by Ceragon Networks Ltd. All rights reserved.

Corporate
Corporate Headquarters: European Headquarters:
Ceragon Networks Ltd. Ceragon Networks (UK) Ltd.
24 Raoul Wallenberg St. 4 Oak Tree Park, Burnt Meadow Road
Tel Aviv 69719, Israel North Moons Moat, Redditch,
Tel: 972-3-645-5733 Worcestershire B98 9NZ, UK
Fax: 972-3-645-5499 Tel: 44-(0)-1527-591900
Email: [email protected] Fax: 44-(0)-1527-591903
www.ceragon.com Email: [email protected]
North American Headquarters: APAC Headquarters
Ceragon Networks Inc. Ceragon Networks (HK) Ltd.
10 Forest Avenue, Singapore RO
Paramus, NJ 07652, USA Level 34 Centennial Tower
Tel: 1-201-845-6955 3 Temasek Avenue
Toll Free: 1-877-FIBEAIR Singapore 039190
Fax: 1-201-845-5665 Tel - + 65 6549 7886
Email: [email protected] Fax: +65 6549 7011

®
FibeAir IP-10 IDU Installation Guide 1-2
Contents

Chapter 1: Installation ................................................................................... 1-4

General ................................................................................................................1-4

Site Requirements ..............................................................................................1-4

Pre-Installation....................................................................................................1-4

Unpacking Equipment at the Site ......................................................................1-5

Installation Requirements ..................................................................................1-5

FibeAir IP-10 Description ...................................................................................1-7

Installing the IDU in a Rack................................................................................1-8

Grounding the IDU............................................................................................1-10

Connecting the IDU ..........................................................................................1-12

TDM Interface Add-on Slots…………………………………………………………1-12

IP-10 Nodal Design…………………………………………...……………………….1-14

Configuring the IDU..........................................................................................1-16

Appendix A: Line Interfaces ....................................................................... 1-17

Appendix B: Connector Pin-Outs ............................................................... 1-21

Appendix C: Protection Information .......................................................... 1-27

Appendix D: Accesories.............................................................................. 1-30

Appendix E: Fan Tray Replacment............................................................. 1-33

®
FibeAir IP-10 IDU Installation Guide 1-3
Chapter 1: Installation
General
This chapter provides instructions for the installation of the FibeAir IP-10 IDU at the customer site.

Site Requirements
Must be located indoors.

The environment temperature must be between -5 C and +55 C.

Easily accessible, but only by authorized personnel.

Available power source of -48 VDC, and the site must comply with National Electric Code (NEC)
standards.

Available management connection (Ethernet or dial-up).

No more than 300 m from RFU location.

In addition, since the IDU will be connected to the RFU, when considering a site, it is important to check for
current and future obstacles on the roof or tower. Possible future obstacles may include trees, new buildings,
window cleaners on the roof, snow that may accumulate in front of the antenna, etc. The site should be
accessible to certified personnel only.
Note about Heat Dissipation: The IP-10 IDU overall heat dissipation is 25W max (~85 BTU/h).
Note about Antenna Location: As with any type of construction, a local permit may be required before
installing an antenna. It is the owner’s responsibility to obtain any and all permits.

Pre-Installation
Packing

The equipment is packed at the factory, and sealed moisture-absorbing bags are inserted.

Transportation

 The equipment is prepared for public transportation. The cargo must be kept dry during transportation,
in accordance with ETS 300 019-1-2, Class 2.3.

 It is recommended to transport the equipment to the installation site in its original packing case.

 If intermediate storage is required, the packed equipment must be stored in dry and cool conditions and
out of direct sunlight, in accordance with ETS 300 019-1-1, Class 1.2.

®
FibeAir IP-10 IDU Installation Guide 1-4
Inspection

Check the packing lists, and ensure that the correct part numbers and quantities of components arrived.

Unpacking Equipment at the Site


A single FibeAir system (1+0) is shipped in 5 crates. Upon delivery, make sure that the following items are
included:

Two indoor units and accessories

Two outdoor units


For 13-38 GHz systems, verify that there is a high RFU and low RFU.

One CD with a management user guide.

Unpack the contents and check for damaged or missing parts. If any part is damaged or missing, contact your
local distributor.

Installation Requirements
Required Tools

The following tools are required to install the IDU:

Philips screwdriver (for mounting the IDU to the rack and grounding screw)

Flathead small screwdriver (for PSU connector)

Sharp cutting knife (for wire stripping)

Crimping tool for ground cable lug crimping (optional: if alternative grounding cable is used).

Cables

In addition to the tools mentioned above, the interface connectors and their pin-outs, can be found in the
following sections in this guide:

Appendix A: Line Interfaces

Appendix B: Connector Pin-Outs

®
FibeAir IP-10 IDU Installation Guide 1-5
Requirements for North America

Restricted Access Area: DC powered equipment should only be installed in a Restricted Access Area.

Installation Codes: The equipment must be installed according to country national electrical codes. For
North America, equipment must be installed in accordance to the US National Electrical Code, Articles 110-
16, 110-17 and 110-18, and the Canadian Electrical Code, Section 12.

Overcurrent Protection: A readily accessible Listed branch circuit overcurrent protective device, rated 15 A,
must be incorporated in the building wiring.

CAUTION: This equipment is designed to permit connection between the earthed conductor of the DC
supply circuit and the earthing conductor at the equipment.

Grounded Supply System: The equipment shall be connected to a properly grounded supply system. All
equipment in the immediate vicinity shall be grounded the same way, and shall not be grounded elsewhere.

Local Supply System: The DC supply system is to be local, i.e. within the same premises as the equipment.

Disconnect Device: A disconnect device is not allowed in the grounded circuit between the DC supply source
and the frame/grounded circuit connection.

®
FibeAir IP-10 IDU Installation Guide 1-6
FibeAir IP-10 Description
FibeAir IP-10 is Ceragon's comprehensive high capacity migration-to-IP network solution. The innovative IP-
10 was designed as a native Ethernet microwave radio platform that can integrate smoothly in any network,
while providing a broad range of software-configurable licensed channel schemes.

IP-10 follows in the tradition of Ceragon's Native2, which allows your network to benfit from both native
TDM and native Ethernet using the same radio. Flexible bandwidth sharing between the TDM and Ethernet
traffic ensures optimal throughput for all your media transfer needs.

IP-10 features a flexible design capable of addressing all network migration scenarios. With its Native2
capability for optimal traffic delivery, and modular architecture for all sites (Tail, Chain, Agg3, Agg2), this
state-of-the-art radio platform offers the best approach to IP migration for advanced networks.

With the widest capacity range (10-500 Mbps) for all capacity needs, advanced Adaptive Code Modulation for
the best spectrum utilization, and a scalable system that ensures future-proof network expansion, IP-10 is the
ideal solution for risk-free migration.

Some of the important points that place IP-10 at the top of the wireless IP market include:

Supports all licensed bands, from 6 to 38 GHz

Supports channel bandwidths of from 7 MHz to 56 MHz

Supports throughputs of from 10 to 500 Mbps per radio carrier (QPSK to 256 QAM)

Incorporates advanced integrated Ethernet switching capabilities

In addition, using unique Adaptive Code & Modulation (ACM), your network benefits from non-stop,
dependable capacity deliverance.

FibeAir IP-10 IDU

®
FibeAir IP-10 IDU Installation Guide 1-7
Installing the IDU in a 19"/ETSI Rack
Warning! The intra-building port(s) of the equipment or subassembly is suitable for
connection to intra-building or exposed wiring or cabling only. The intra-building port(s) of the
eqiupment or subassembly MUST NOT be metallically connected to interfaces that connect
to the OSP or its wiring. These interfaces are designed for use as intra-building interfaces
only and require isolation from the exposed OSP cabling. The addition of Primary Protectors
is not sufficient protection in order to connect these interfaces metallically to OSP wiring.

The FibeAir IP-10 IDU is installed in a standard 19" ETSI rack as shown in the following illustration.

As shown in the illustration, four screws, supplied with the installation kit, are used to secure the IDU to the
rack.

®
FibeAir IP-10 IDU Installation Guide 1-8
IDU Dimensions
The following illustration shows the dimensions (in millimeters) of the FibeAir IP-10 IDU.

®
FibeAir IP-10 IDU Installation Guide 1-9
Grounding the IDU
The following illustration shows how the IDU is grounded to the rack.

Single
Point
Stud
Grounding
Wire

A grounding wire is connected below the IDU-RFU interface using a single screw with two washers.

IDU Grounding Notes

• The IDU is suitable for installation in a Common Bonding Network (CBN).

• Only copper wire should be used.

• The wire must be at least 6 AWG.

• Connector and connection surfaces must be plated. Bare conductors must be be coated with antioxidant
before crimp connections are made to the screws.

• FibeAir provides a ground for each IDU, via a one-hole mounted lug onto a single-point stud. The stud
must be installed using a UL-listed ring tongue terminal, and two star washers for anti-rotation.

®
FibeAir IP-10 IDU Installation Guide 1-10
• For antenna ports, lightning protection is used that does not permit transients of a greater magnitude than
the following:
Open Circuit: 1.2-50us 600V
Short Circuit: 8-20us 300A

• The ampacity of the conductor connecting the IDU frame to the DC return conductor is equal to, or
greater than, the ampacity of the associated DC return conductor.

Power Supply Notes

When selecting a power source, the following must be considered:

• DC power can be from -40.5 VDC to -60 VDC.

• Recommended: Availability of a UPS (Uninterrupted Power Source), battery backup, and emergency
power generator.

• Whether or not the power source provides constant power (i.e., power is secured on weekends or is shut
off frequently and consistently).

• The power supply must have grounding points on the AC and DC sides.

Caution!
The user power supply GND must be connected to the positive pole in the IDU power supply. Any other
connection may cause damage to the system!

Power supply grounding should be in accordance with the following illustration:

®
FibeAir IP-10 IDU Installation Guide 1-11
Connecting the IDU
This section describes how the IDU interfaces are connected for a 1+0 system. The interfaces include line,
system (IDU-RFU), and management ports.
For interface specifications, see Appendix A - Line Interfaces and Cables.
For connector pin-outs, see Appendix B - Connector Pin-Outs.
For a list of accessories, see Appendix D - Accessories.

Note: For a 1+1 system, a protection panel is used, as described in Appendix C - Protection Information.

Interface Descriptions

The following photo shows the different IDU ports and their functions.

IDU Front Panel


TDM interfaces Fans
add-on slot drawer

16 x E1/T1s
External
(optional) GND
Alarms RFU
(DB9) interface Power
Protection
Interface 2 x GE ”combo” 5 x FE (N-Type) -48V DC
Engineering User ports Electrical
order-wire (RJ45)
Channel Electrical (RJ45) (RJ45)
(optional) (optional) or Optical (SFP)
(RJ45)

The IDU front panel includes the following auxiliary interfaces:

Terminal console

Ethernet out-of-band management

Ethernet wayside

®
FibeAir IP-10 IDU Installation Guide 1-12
Optional:

Engineering Order Wire (EOW)

User channel (V11, RS232)

External alarms

Note: The Fast Ethernet interface channels can be logically configured for either Fast Ethernet traffic, or
protection, wayside, or management traffic.

TDM Interface Add-on Slots:

FibeAir IP-10 Release 2 supports TDM interface expansion cards ("T-cards") for:

16 x E1s/T1s (32 total per unit)

STM-1/OC-3 (terminal mux for up to 63 E1s or 84 T1s)

Supported TDM Expansion Card Types

The T-cards are field-upgradable, and add a new dimension to the FibeAir IP-10 migration flexibility.

16 x E1/T1 T-Card

®
FibeAir IP-10 IDU Installation Guide 1-13
IP-10 Nodal Design
IP-10 design for the nodal solution is based on a "blade" approach. Viewing the unit from the rear, each IDU
can be considered a "blade" within a nodal enclosure.

A "blade" can operate as a stand-alone unit at a tail site.

The "rack chassis" is also modular, for optimum economical future upgrade, network design flexibility,
and efficient installation, maintenance, and expansion.

The solution is modular and forms a single unified nodal device, with a common Ethernet Switch,
common E1 Cross-Connect, single IP address, and a single element to manage.

®
FibeAir IP-10 IDU Installation Guide 1-14
Nodal Design Types

The following types of nodal enclosures are supported:

Modular Rack Chassis

The nodal enclosure is a scalable unit. Each enclosure can be added to another enclosure for modular rack
installation.

®
FibeAir IP-10 IDU Installation Guide 1-15
IDU-ODU/RFU Coax Cable
The Coax Cable that connects between the IDU and the ODU/RFU should be terminated with N-type male
connectors.

Important! Make sure that the inner pin of the connector does not exceed the edge of the connector.

The cable should have a maximum attenuation of 30 dB at 350 MHz.

Configuring the IDU


After the system is installed and tested, and antenna alignment is performed, the next step is IDU setup and
configuration.
Setup procedures are performed using the FibeAir IP-10 CLI (Command Line Interface) or Web Based
Management.
For an explanation of the CLI, see the FibeAir IP-10 CLI Guide.
For an explanation of the Web Based Management, see the FibeAir IP-10 Web Based Management Guide.

®
FibeAir IP-10 IDU Installation Guide 1-16
Appendix A: Line Interfaces
This section provides a description of the FibeAir main channel, wayside channel, and order wire channel
interfaces.

The interfaces are located on the FibeAir IDU front panel.

The following interface terms should be noted:

 For connectors or signals labeled TX, the signals are sent from FibeAir.

 For connectors or signals labeled RX, the signals are sent to FibeAir.

Main Channel Interfaces


Main channel interfaces include the following:

Gigabit Ethernet (Optical)

1000Base-SX (Multi Mode)

Wavelength: 850 nm
Receptacle: MSA compliant, SFP (Small Form Factor Pluggable Ports)
Connector: LC
Max Segment Length: 220 m (1351 ft), 500 m (1650 ft)
Cable Type: For Max Segment = 220 m: 62.5 µm MMF
For Max Segment = 500 m: 50 µm MMF

1000Base-LX (Single Mode)

Wavelength: 1350 nm
Receptacle: MSA compliant, SFP (Small Form Factor Pluggable Ports)
Connector: LC
Max Segment Length: 550 m (1805 ft), 5000 m (16404 ft)
Cable Type: For Max Segment = 550 m: 62.5 µm MMF, 50 µm MMF
For Max Segment = 5000 m: 10 µm SMF

®
FibeAir IP-10 IDU Installation Guide 1-17
Gigabit Ethernet / Fast Ethernet (Electrical)

100/1000BaseT (Twisted Pair Cable)


Connector: RJ-45
Max Segment Length: Up to 100 m (328 ft) per IEEE802.3
Cable Type: Compatible with shielded and unshielded twisted pair category 5 cables.

Optional 16xE1/T1
Connector MDR 69-pin
Used with: Twisted pair
Interface Type E1/T1
Number of ports 16 per unit (optional)
Timing mode: Retimed
Framing Unframed (full transparency)
Coding E1: HDB3
T1: AMI/B8ZS
Range: 5m
Line Impedance 120 Ω/100 Ω balanced. Optional module for 75 Ω unbalanced
Compatible Standards ITU-T G.703, G.736, G.775, G.823, G.824, G.828, ITU-T I.432, ETSI ETS 300
147, ETS 300 417, ANSI T1.105, T1.102-1993, T1.231, Bellcore GR-253-core,
TR-NWT-000499

Wayside Channel Interface


The wayside channel is used as an auxiliary audio or data channel.

10/100BaseT (Ethernet)

Connector: Shielded RJ-45


Used with: UTP Cat 5
Protocols supported: Ethernet (10/100BaseT), half or full duplex
Timing mode: Retimed
Range: 100 m
Impedance: 100 Ω

®
FibeAir IP-10 IDU Installation Guide 1-18
Protection Channel Interface

Protection

Connector: Shielded RJ-45


Used with: UTP Cat 5
Protocols supported: Ethernet (10/100BaseT), half or full duplex
Timing mode: Retimed
Range: 100 m
Impedance: 100 Ω

Management Channel Interface

Out-of-Band Management

Connector: Shielded RJ-45


Used with: UTP Cat 5
Protocols supported: Ethernet (10/100BaseT), half or full duplex
Timing mode: Retimed
Range: 100 m
Impedance: 100 Ω

Order Wire Channel Interface


The Order Wire is used for audio transmission for testing or maintenance purposes.
The specifications for this channel are as follows:

Termination Type: Headset stereo plug, 2.5 mm

Frequency band (KHz) 0.3-3.4

Input impedance (ohms) ~2000

Output impedance (ohms) 32

®
FibeAir IP-10 IDU Installation Guide 1-19
User Channel Interface
The user channel is a CVSD audio channel that delivers 64 Kbps, via an RJ-45 connector.
The interface can be used for one of the following:

Asynchronous RS-232

Asynchronous V-11

Co and Contra Directional

®
FibeAir IP-10 IDU Installation Guide 1-20
Appendix B: Connector Pin-Outs

General
This appendix provides pin-outs for FibeAir IDU connectors, including the following:

 External Alarms Connector

 Protection/Wayside/Management Connector

 Power Connector

 16 x E1/T1 Connector

 Ethernet 10/100/1000 Connector

 Ethernet 10/100 Connector

 User Channel Connector

®
FibeAir IP-10 IDU Installation Guide 1-21
External Alarms Connector Pin-Out
The External Alarms connector is a D-type 9-pin connector.

Pin Signal I/O Description

1 EXT_IN5 Input External input alarm #5

2 EXT_IN4 Input External input alarm #4

3 EXT_IN3 Input External input alarm #3

4 EXT_IN2 Input External input alarm #2

5 EXT_IN1 Input External input alarm #1

6 GND GND GND

7 RELAY_1_NO Output Relay #1, normally open pin

8 RELAY_1_C Output Relay #1, common pin

9 RELAY_1_NC Output Relay #1, normally closed pin

Protection/Wayside/Management Connector Pin-Out


The Protection/Wayside/Management connector is an RJ-45, 8-pin, female type connector.

RJ-45 Male
Connector Signal
Pin
1
Twisted Pair, Out - Tx
2
3
Twisted Pair, In - Rx
6
4
Not Connected
5
7
Not Connected
8

®
FibeAir IP-10 IDU Installation Guide 1-22
Power Connector Pin-Out
The power connector pin-out is as follows:

Left Pin (#1) Right Pin (#2)

-48V (return current) 0V

Note that right/left refers to viewing the panel from the front.

16 x E1/T1 Connector
The 16 x E1/T1 connector is a SCSI 68-pin connector.

Label on the
Pin # Signal Type
Twisted Pair
1 OUT - TIP1
Ch1 Tx TWISTED PAIR
35 OUT - RING1
2 OUT - TIP2
Ch2 Tx TWISTED PAIR
36 OUT - RING2
3 OUT - TIP3
Ch3 Tx TWISTED PAIR
37 OUT - RING3
4 OUT - TIP4
Ch4 Tx TWISTED PAIR
38 OUT - RING4
5 OUT - TIP5
Ch5 Tx TWISTED PAIR
39 OUT - RING5
6 OUT - TIP6
Ch6 Tx TWISTED PAIR
40 OUT - RING6
7 OUT - TIP7
Ch7 Tx TWISTED PAIR
41 OUT - RING7
8 OUT - TIP8
Ch8 Tx TWISTED PAIR
42 OUT - RING8
9 OUT - TIP9
Ch9 Tx TWISTED PAIR
43 OUT - RING9
10 OUT - TIP10
Ch10 Tx TWISTED PAIR
44 OUT - RING10
11 OUT - TIP11 Ch11 Tx TWISTED PAIR

®
FibeAir IP-10 IDU Installation Guide 1-23
45 OUT - RING11
12 OUT - TIP12
Ch12 Tx TWISTED PAIR
46 OUT - RING12

Label on the
Pin # Signal Type
Twisted Pair
13 OUT - TIP13
Ch13 Tx TWISTED PAIR
47 OUT - RING13
14 OUT - TIP14
Ch14 Tx TWISTED PAIR
48 OUT - RING14
15 OUT - TIP15
Ch15 Tx TWISTED PAIR
49 OUT - RING15
16 OUT - TIP16
Ch16 Tx TWISTED PAIR
50 OUT - RING16
19 IN - TIP1
Ch1 Rx TWISTED PAIR
53 IN - RING1
20 IN - TIP2
Ch2 Rx TWISTED PAIR
54 IN - RING2
21 IN - TIP3
Ch3 Rx TWISTED PAIR
55 IN - RING3
22 IN - TIP4
Ch4 Rx TWISTED PAIR
56 IN - RING4
23 IN - TIP5
Ch5 Rx TWISTED PAIR
57 IN - RING5
24 IN - TIP6
Ch6 Rx TWISTED PAIR
58 IN - RING6
25 IN - TIP7
Ch7 Rx TWISTED PAIR
59 IN - RING7
26 IN - TIP8
Ch8 Rx TWISTED PAIR
60 IN - RING8
27 IN - TIP9
Ch9 Rx TWISTED PAIR
61 IN - RING9
28 IN - TIP10
Ch10 Rx TWISTED PAIR
62 IN - RING10
29 IN - TIP11
Ch11 Rx TWISTED PAIR
63 IN - RING11
30 IN - TIP12 Ch12 Rx TWISTED PAIR

®
FibeAir IP-10 IDU Installation Guide 1-24
64 IN - RING12
31 IN - TIP13
Ch13 Rx TWISTED PAIR
65 IN - RING13
32 IN - TIP14
Ch14 Rx TWISTED PAIR
66 IN - RING14

Label on the
Pin # Signal Type
Twisted Pair
33 IN - TIP15
Ch15 Rx TWISTED PAIR
67 IN - RING15
34 IN - TIP16
Ch16 Rx TWISTED PAIR
68 IN - RING16
17 SHELL - SHIELD
18 SHELL - SHIELD
51 SHELL - SHIELD
52 SHELL - SHIELD

Ethernet 10/100/1000 Connector Pin-Out


The Ethernet 10/100/1000 connector is an RJ-45, 8-pin, female type connector.

RJ-45
Female
Signal
Connector
Pin
1
Twisted Pair (Tx & Rx)
2
3
Twisted Pair (Tx & Rx)
6
4
Twisted Pair (Tx & Rx)
5
7
Twisted Pair (Tx & Rx)
8

®
FibeAir IP-10 IDU Installation Guide 1-25
Ethernet 10/100 Connector Pin-Out
The Ethernet 10/100 connector is an RJ-45, 8-pin, female type connector.

RJ-45
Female
Signal
Connector
Pin
1
Twisted Pair, Out - Tx
2
3
Twisted Pair, In - Rx
6
4
Not Connected
5
7
Not Connected
8

User Channel Connector Pin-Out


The user channel connector is an RJ-45 connector.

Asynchronous Asynchronous
Pin I/O
RS-232 V11

1 NC UC_TXD_P Out

2 NC UC_TXD_N Out

3 NC NC NC

GND GND
4 COM
Signal Ground Signal Ground

UC_RS232_TXD
5 NC Out
Transmitted Data

UC_RS232_RXD
6 NC In
Received Data

7 NC UC_RXD_P In

8 NC UC_RXD_N In

®
FibeAir IP-10 IDU Installation Guide 1-26
Appendix C: Protection Information

General
This appendix provides information about the FibeAir IP-10 protection equipment.

Protection Patch Panel


In IP-10 protection configurations, a protection patch panel is used to connect the units and provide protection
switching.

As shown in the illustration above, the protection panel (in the middle) provides the ports used to link the two
IP-10 units for protection switching when a system fault occurs.

®
FibeAir IP-10 IDU Installation Guide 1-27
Panel Components
The following illustration shows the panel components.

User
IDU #1 User FE
16xE1/T1
4 x FE Open-Ended
Open-Ended
Straight RJ-45 Cross RJ-45
IDU #1 MDR Connector
Connectors Connectors
16xE1/T1
MDR Connector

IDU #2
16xE1/T1 User
IDU #2 Optical GbE
MDR Connector 4 x FE LC/LC
Straight RJ-45 Connector
Connectors

Part Numbers
The part numbers for the MDR cables are as follows:

16 x E1/T1 MDR Connector:


WA-0276-0, 0.6 meters

User 16 x E1/T1 MDR Connector:


WA-0277-0, 5 meters
WA-0278-0, 10 meters
WA-0309-0, 25 meters

Optical splitter used for GbE 1+1 systems (see the following section):
AO-0038-0
AO-0039-0
AO-0059-0
AO-0060-0

®
FibeAir IP-10 IDU Installation Guide 1-28
GbE Optical Splitter
The following illustration shows the rear side of the IP-10 protection panel, with the optical splitter.

Optical Splitter

The optical splitter is an LC/LC female adapter.

®
FibeAir IP-10 IDU Installation Guide 1-29
Appendix D: Accessories
The following tables list the FibeAir IP-10 accessories.

Cables
Part Number Marketing Model Marketing Description
WA-0242-1 X-WSC-E1/T1 E1/T1 WSC x-ed cable
WA-0246 IDU-EXT-ALARMS-CBL-2.5m IDU External Alarms open cable 2.5m
WA-0259 CBL-16E1-CB-120-75 16E1 cable MDR/2xDB44 5m to CB-120-75
WA-0275 IDU-UC-CBL-2m User channel cable 2m D-type 9 pin male
WA-0276-0 IP10-CBL-16IO-PROT-0.6m IP-10 16 I/O port protection cable straight 0.6m
WA-0277-0 IP10-CBL-16IO-5M IP-10 16 I/O port cable open 5M
WA-0278-0 IP-10-CBL-16IO-10M IP-10 16 I/O port cable open 10M
WA-0284-0 IP10-CBL-16IO-XED-0.6m IP-10 16 I/O port crossed cable 0.6m
WA-0309-0 IP-10-CBL-16IO-25M IP-10 16 I/O port cable open 25M

Panels
Part Number Marketing Model Marketing Description
EN-0254-0 IP10-ETH-16E1-PROT-PANEL IP-10 Eth + 16E1 protection panel
EN-0256-0 IP10-ETH-16T1-PROT-PANEL IP-10 Eth + 16T1 protection panel
EN-0258-0 IP10-16E1-PROT-PANEL IP-10 16E1 protection panel
EN-0259-0 IP10-16T1-PROT-PANEL IP-10 16T1 protection panel
EN-0262-0 IP10-ETH-PROT-PANEL IP-10 Eth only protection panel

®
FibeAir IP-10 IDU Installation Guide 1-30
Optical Splitters
Part Marketing
Marketing Model Item Description
Number Description
SM/LC Optical 1x2 Single mode Fiber Dual Windows Wideband
AO-0038-0 GBE-SPL-SM Splitter conn. Couplers, ±40nm, LC/LC, 1310nm,1m length,
1300nm 50/5 PVC 2.0mm cable (yellow), 50/50 coupling ratio.
1x2 multimode mode Fiber Dual Windows
MM/LC Optical
Wideband Couplers, ±40nm, LC/LC, 850nm,1m
AO-0039-0 GBE-SPL-MM-2M Splitter 62.5/125
length for each port, PVC 2.0mm cable, 50/50
2M
coupling ratio
1x2 multimode mode Fiber Dual Windows
MM/LC Optical
Wideband Couplers, ±40nm, LC/LC,
AO-0059-0 GBE-SPL-MM-1M Splitter 62.5/125
850nm,0.5m length for each port, PVC 2.0mm
1M
cable, 50/50 coupling ratio
1x2 multimode mode Fiber Dual Windows
MM/LC Optical
Wideband Couplers, ±40nm, LC/LC,
AO-0060-0 GBE-SPL-MM-0.6M Splitter 62.5/125
850nm,0.3m length for each port, PVC 2.0mm
0.6M
cable, 50/50 coupling ratio

Optical Cables
Part Marketing
Marketing Model Item Description
Number Description
Pairs of Fiber Patchcord Single mode- LC/SC,
Duplex Optical
OP-SM-CBL-LC-SC- Length:15M, Duplex PVC 2mm cable, with LC
AO-0033-0 Cable LC-SC
DPLX 15M connector type on one end and SC connector on
SM 15M
the other end.
Pairs of Fiber Patchcord Single mode- LC/SC,
Duplex Optical
OP-SM-CBL-LC-SC- Length:3M, Duplex PVC 2mm cable, with LC
AO-0035-0 Cable LC-SC
DPLX 3M connector type on one end and SC connector on
SM 3M
the other end.
Duplex Optical
OP-SM-CBL-LC-SC- DUPLEX LC-SC (Tx TO Tx) SM 9/125 YELLOW
AO-0041-0 Cable LC-SC
DPLX 1M COLOR R-9D-1-P, 13MM, 1M
SM 1m
Duplex Optical DUPLEX FIBER OPTIC MM PATCH CORD
OP-MM-CBL-LC-
AO-0044-0 Cable LC-SC WITH LC/UPC-SC/UPC (Tx TO Tx) 62.5/125,
SC-DPLX 2M
MM 2M ORANGE COLOR, 2M, 3MM O.D.
Duplex Optical DUPLEX FIBER OPTIC MM PATCH CORD
OP-MM-CBL-LC-
AO-0045-0 Cable LC-SC WITH LC/UPC-SC/UPC (Tx TO Tx) 62.5/125,
SC-DPLX 10M
MM 10M ORANGE COLOR, 10M, 3MM O.D.
Duplex Optical DUPLEX FIBER OPTIC MM PATCH CORD
OP-MM-CBL-LC-
AO-0048-0 Cable LC-LC WITH LC/UPC-LC/UPC (Tx TO Tx) 62.5/125
LC-DPLX 0.5M
MM 0.5M ORANGE COLOR, 0.5M, 2MM O.D.
Duplex Optical
OP-SM-CBL-LC-SC- DUPLEX LC-SC (Tx TO Tx) SM 9/125 YELLOW
AO-0055-0 Cable LC-SC
DPLX 10M COLOR, 3MM, 10M
SM 10m

®
FibeAir IP-10 IDU Installation Guide 1-31
Part Marketing
Marketing Model Item Description
Number Description
Duplex Optical
OP-SM-CBL-LC-SC- DUPLEX LC-SC (Tx TO Tx) SM 9/125 YELLOW
AO-0057-0 Cable LC-SC
DPLX 5M COLOR, 3MM, 5M
SM 5m
Duplex Optical DUPLEX FIBER OPTIC MM PATCH CORD
OP-MM-CBL-LC-
AO-0066-0 Cable LC-LC WITH LC/UPC-LC/UPC (Tx TO Tx) 62.5/125
LC-DPLX 3M
MM 3M ORANGE COLOR, 3M, 2MM O.D.
Duplex Optical DUPLEX FIBER OPTIC MM PATCH CORD
OP-MM-CBL-LC-
AO-0067-0 Cable LC-LC WITH LC/UPC-LC/UPC (Tx TO Tx) 62.5/125
LC-DPLX 6M
MM 6M ORANGE COLOR, 6M, 2MM O.D.
Pairs of Fiber Patchcord Single mode- LC/LC,
Duplex Optical
OP-SM-CBL-LC-LC- Length:3M, Duplex PVC 2mm cable, with LC
AO-0071-0 Cable LC-LC
DPLX 3M connector type on one end and LC connector on
SM 3M
the other end.

Optical Adaptors
Part Marketing
Marketing Model Item Description
Number Description
Adaptor
OP-SM-LC-LC-
AO-0042-0 Female/Female SM SIMPLEX LC-LC SM ADAPTOR
ADPT-SMPLX
LC-LC Simplex

®
FibeAir IP-10 IDU Installation Guide 1-32
Appendix E: Fan Tray Replacement

Fan Tray Replacment Procedure


If it is necessary to replace the fan tray in the IDU, replace it as follows:

1. Remove the current fan tray by releasing the safety screw and removing the tray.

2. Insert the new fan tray entirely in its place and tighten the safety screw.

®
FibeAir IP-10 IDU Installation Guide 1-33