New features
With peak efficiencies of 97,8% and an input voltage range
from 340 to 900 V, the new NT series offers the optimum
yield for many interconnection options.
All inverters comply with the new German medium-voltage
guideline and, due to Power Control, they are applicable in
installations with an output of more than 100 kW.
The new NT series can be used throughout Europe: the coun-
try of installation can be set on site at the touch of a button.
DC Input
Rated DC power 2625 W 3885 W 4410 W 5250 W
Maximum DC current 7.5 A 11.0 A 13.0 A 18.0 A
Nominal DC voltage 340 V
MPP voltage range 340 V ... 750 V
Maximum voltage DC 900 V
Number of inputs per MPP tracker 2 x Tyco Solarlok
Number of MPP trackers 1
AC output
Rated AC output power 2500 W 3680 W 4200 W 5000 W
Maximum AC power 2500 W 3700 W 4200 W 5000 W
Nominal AC current 10.9 A 16.0 A 18.3 A 21.7 A
Maximum AC current 12.0 A 17.8 A 20.2 A 24.0 A
Nominal frequency 50 Hz
Frequency tolerance range 47.5 Hz ... 50.2 Hz (according to DIN VDE 0126-1-1)
Grid voltage 230 V
AC voltage range -20% ... +15% (according to DIN VDE 0126-1-1)
Distortion factor at Pn < 2%
Reactive power factor (cos phi) 1 or adjustable from –0,9 to +0,9
Grid voltage monitoring according to DIN VDE 0126-1-1
Earth fault protection RCD (according to DIN VDE 0126-1-1)
Insulation, frequency and DC current monitoring integrated (according to DIN VDE 0126-1-1)
Required phases, number of grid connections 3 (L1, L2, L3, N, PE)
Number of feed-in phases (230 V single-phase) 1
Performance
Stand-by consumption 4.0 W
Night-time consumption < 0.1 W
Maximum efficiency 97,8% 97,8% 97,8% 97,8%
European efficiency 97,4% 97,4% 97,3% 97,2%
MPP efficiency (static) > 99%
Switching concept HERIC® topology, transformerless
Other
DC switch (according to IEC 60947-1/3) integrated
Grid-connection fuse layout 16 A 25 A 32 A 32 A
Data interfaces Ethernet, CAN, RS485, voltageless alarm relay, S0 pulse output, modem
Sensor interfaces irradiation, temperature
Display LCD, backlit, 128 x 64 pixels
Plant supervision Active alarm via e-mail, Sunways Browser, Sunways Portal
IP degree of protection according to IEC 60529 IP 54
Max. relative humidity 95%
Cooling free convection
Ambient temperature -25°C ... 45°C (at full load)
Overload behaviour working point adjustment
Dimensions (height x width x depth) 59 x 35 x 21 cm
Weight 26 kg
Type of installation wall installation
Noise development < 35 dB (A)
Standard warranty (option) 5 years (10 years)
Certificates CE, DIN VDE 0126-1-1
100%
99%
98%
97%
96%
95%
94%
93%
92%
91%
90%
89%
88%
87%
86%
85%
84%
83% UDC=340 V
82% UDC=500 V
81% UDC=720 V
80%
0 250 500 750 1000 1250 1500 1750 2000 2250 2500
Output power (%) 5,0 10,0 20,0 30,0 50,0 100,0 Max Euro
Efficiency 340 V 94,7 96,4 97,3 97,6 97,7 97,2 97,8 97,4
500 V 93,8 95,4 96,6 97,0 97,3 96,9 97,3 96,9
720 V 92,6 94,5 95,8 96,4 96,8 96,6 96,9 96,3
Values based on 230 V mains voltage, cos phi = 1 and an ambient temperature of 25°C.
80%
0 370 740 1110 1480 1850 2220 2590 2960 3330 3700
Ausgangsleistung
Output power (W)(W)
Output power (%) 5,0 10,0 20,0 30,0 50,0 100,0 Max Euro
Efficiency 340 V 96,0 96,9 97,6 97,7 97,5 96,9 97,8 97,4
500 V 95,1 95,9 97,0 97,2 97,2 96,5 97,3 96,9
720 V 93,8 95,1 96,4 96,7 96,8 96,2 96,9 96,4
Values based on 230 V mains voltage, cos phi = 1 and an ambient temperature of 25°C.
100%
99%
98%
97%
96%
95%
94%
93%
92%
91%
90%
89%
88%
87%
86%
85%
84%
83% UDC=340 V
82% UDC=500 V
81% UDC=720 V
80%
0 420 840 1260 1680 2100 2520 2940 3360 3780 4200
Output power (%) 5,0 10,0 20,0 30,0 50,0 100,0 Max Euro
Efficiency 340 V 96,0 97,2 97,6 97,7 97,3 96,7 97,8 97,3
500 V 95,1 96,1 97,1 97,3 97,1 96,6 97,3 96,9
720 V 93,8 95,5 96,6 96,8 96,7 96,1 96,9 96,4
Values based on 230 V mains voltage, cos phi = 1 and an ambient temperature of 25°C.
80%
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000
Ausgangsleistung
Output power (W)(W)
Output power (%) 5,0 10,0 20,0 30,0 50,0 100,0 Max Euro
Efficiency 340 V 96,4 97,3 97,7 97,6 97,2 96,4 97,8 97,2
500 V 95,4 96,6 97,2 97,3 96,9 96,3 97,3 96,8
720 V 94,5 95,8 96,7 96,8 96,6 95,8 96,9 96,4
Values based on 230 V mains voltage, cos phi = 1 and an ambient temperature of 25°C.