Fan Coil Units (DX-COIL With Heat Pump) : High Wall
Fan Coil Units (DX-COIL With Heat Pump) : High Wall
HVAC
Fan Coil Units (DX-COIL With Heat Pump)
Supply, Install of Split type air conditioning unit, condensing unit, fixings to pad , support
framing, control, wiring, thermostat, refrigerant and condensate drain pipework, insulation
and all other accessories.
High Wall
Cooling capacity FCU-01/ACU-01 (18,000 Btu/hr ) - 1.5 TR
Cooling capacity FCU-02/ACU-02 (24,000 Btu/hr ) - 2.0 TR
Cooling capacity FCU-03/ACU-03 (30,000 Btu/hr ) - 2.5 TR
Cooling capacity FCU-04/ACU-04 (36,000 Btu/hr ) - 3.0 TR
Free Stand Unit
Cooling capacity FCU-05/ACU-05 (96,000 Btu/hr ) - 8.0 TR
Cooling capacity FCU-06/ACU-06 (100,000 Btu/hr ) - 8.3 TR
Refrigerant Pipe Concealed
3/5"
3/8"
Refrigerant Pipe Exposed - Pipe Insulation
3/5"
3/8"
condensate drain pipe
20mm
25mm
Ventilating Fans
Supply, install, testing and commissioning Fans (UL listed), including flanges, support
framing, mounting bolts, isolating switches, overload protection, back draft damper,
shutter damper c/w wire mesh, fixings, accessories and connection.
Wall Mounted Fan Type
Wall Mounted Fan EF-01,Capacity - 100cfm
Exhaust Fans, Inline Type
Inline Fan EF-02,Capacity - 300cfm
Exhaust Fans, Dome Type
Dome Fan EF-03,Capacity - 300cfm
Dome Fan EF-04,Capacity - 6,000cfm
Galvanised Sheet Steel Duct
Supply, install, exhaust air duct and all other accessories. Concealed
26 Guage
Exhaust Air Diffuser
Supply, install, exhaust air diffusers
150X150mm
Exhaust Air Louver
Supply, install, exhaust air louver
300X150mm
Quantity Unit
18 No
14 No
8 No
17 No
2 No
5 No
748 mtr.
748 mtr.
76 mtr.
76 mtr.
1,046 mtr.
434 mtr.
33 No
1 No
1 No
61 No
46 Sq.m
9 No
1 No
ELECTRIC FIREPUMP-2000 GPM @ 10BAR PRESSURE 1
DISEL STANDBY FIREPUMP-2000 GPM @ 7BAR PRESSURE 1
JOCKY FIREPUMP-200 GPM @ 10 BAR PRESSURE 1
FIRE HOSE CABINET 1" X 30 MTR. LONG - FHC 23
ZONE CONTROL VALVE - ZCV-4" 2
ZONE CONTROL VALVE - ZCV-6" 4
FIRE EXTINGUISHER DRY POWDER 6KG - FED 59
FIRE EXTINGUISHER CO2 6KG - FEC 41
UPRIGHT SPRINKLER 1/2" 629
ALARM CHECK VALVE - 8" 1
GATE VALVE - 1/5" 1
GATE VALVE - 2" 2
GATE VALVE - 4" 1
GATE VALVE - 8" 1
CHECK VALVE - 8" 1
FIRE DEPARTMENT CONNECTION 4"x2.5"x2.5" 1
U/G PVC PIPE ∅6'' 92m
U/G PVC PIPE ∅8'' 226m
FOAM System
PENDENT FOAM SPRINKLER 1/2" 175
FOAM SPRINKLER PIPE Ø1.5" 525m
FOAM SPRINKLER PIPE Ø6" 313m
Foam Liquid Concentrate Tank 1
Deluge Valve 1
Check Valve 1
Gate Valve 3
Description Quantity Unit
Supply and installation of seamless steel pipe ASTM A-53, sch 40 complete
with fittings, as shown on drawings and specified
25 mm dia. 1 mtr
32 mm dia. 1 mtr
40 mm dia. 1 mtr
50 mm dia. 1 mtr
63 mm dia. 1 mtr
75 mm dia. 1 mtr
100 mm dia. 1 mtr
150 mm dia. 1 mtr
External Works
Isolating Valves
25 mm diameter. 1 No
Inspector test & drain connection, 50mm dia with 6mm PRV 1 No
PRS, 65 mm diameter. 1 No
Drain
SupplyValve
and Installation of drain valves, complete with accessories required for
a complete functioning system and complying to relevant authorities
regulations, all in accordance with the specifications and drawings.
Approved Makes: Watts, Keystone, Oventrop, T&A, Econosto and Tozen.
Valve, 25 mm diameter. 1 No
Ditto, 32 mm diameter (Threaded) 1 No
Ditto, 40 mm diameter (Threaded) 1 No
Angle valve
Valve, 20 mm diameter. 1 No
Pressure Guage
Supply and installation of pressure gauge, liquid filled, heavy duty, all as
specified and shown on drawings.
Approved Makes: Hunter, Weiss, Trerice and Badotherm.
PGV, 20 mm diameter. 1 No
Breaching Inlet
Supply and Install breching inlet as per the authority regulations, all in
accordance with the specifications and drawings.
Valve, 150 mm diameter 4 way breaching inlet with cap and drain. 1 No
Valve, 150 mm diameter 2 way breaching inlet with cap and drain. 1 No
Siamese Connection-4"x2-1/2"x2-1/2" 1 No
Sprinkler System
Supply and installation of automatic zone check system complete with flow
switch with alarm, pressure gauges, test drain valve, gate valve with
supervisory switch, all in accordance with the specifications and drawings.
Ditto, 65 mm diameter 1 No
Ditto, 80 mm diameter 1 No
Ditto, 100 mm diameter 1 No
Ditto, 125 mm diameter 1 No
Ditto, 150 mm diameter 1 No
Ditto, 200 mm diameter 1 No
5 kg CO2 (portable) 1 No
Fire Blanket 1 No
ELECTRIC PUMP
Fire Electric - Horizontal Spilt case, 47 l/s (750 gpm) ,70m head (2 E) 1 No
SS-FP-2, horizontal split-case, external hydrant fire pumps (electric), 1,000 gpm
capacity, 10.35 bar (150 psi) approx. head (standby operation). No
1
DIESEL PUMP
Supply of UL listed and FM approved diesel pump, Base frame,controller,
control panel dialy fuel tank , all in accordance with the specifications and
drawings and the concerned authority regulations.
Fire Diesel pump - Horizontal Spilt case, 63l/s (998 gpm), 170m head + No
1
Diesel Storage tank
Fire Pump - Diesel - Horizantal split ,94.7l/s, 125m head (1S) 1 No
JOCKEY PUMP
Supply of UL listed and FM approved jockey fire pump, including the base
frame, controller and control panel , all in accordance with specifications and
drawings and relevant authority regulations.
Fire jockey pump - Vertical Multi Stage, 4l/s (63 gpm), 175m head 1 No
Fire jockey pump - Vertical Multi Stage, 3l/s (50 gpm), 390 ft head. 1 No
Fire jockey pump - Vertical Multi Stage, 3l/s (50 gpm), 70m head. 1 No
FM 200 SYSTEM
FM 200 system including cylinders, pipes, pipe fittings, nozzles, valves and
necessary accessories, cylinder brackets, discharge flexible horse, supports,
hangers and connections complete