75% found this document useful (4 votes)
7K views6 pages

Mikro - Power Factor Regulator

The document describes a power factor regulator that automatically adjusts the power factor of an electrical system. It features microprocessor control, automatic switching and compensation, monitoring of power metrics, programmable sensitivity settings, and alarms. Models include 6, 8, 12, or 14 output steps, operate at 50 or 60 Hz, can adjust lagging or leading power factors from 0.8 to 0.8, and have IP54 enclosure protection for panel mounting.

Uploaded by

shawonscribd
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
75% found this document useful (4 votes)
7K views6 pages

Mikro - Power Factor Regulator

The document describes a power factor regulator that automatically adjusts the power factor of an electrical system. It features microprocessor control, automatic switching and compensation, monitoring of power metrics, programmable sensitivity settings, and alarms. Models include 6, 8, 12, or 14 output steps, operate at 50 or 60 Hz, can adjust lagging or leading power factors from 0.8 to 0.8, and have IP54 enclosure protection for panel mounting.

Uploaded by

shawonscribd
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Power Factor Regulator

PFR140
PFR120
PFR80
PFR60
Features
• Microprocessor based intelligent auto switching
control

• Automatic C/K and rated step adjustment

• Automatic CT polarity correction

• Display of power factor, current & total harmonic


distortion of current

• Programmable sensitivity

• Last step can be used as alarm/fan output

• Under/over voltage alarm, under/over compensate


alarm & high harmonic distortion alarm

• User-friendly setting

• Complies with IEC 61000-6-2 standard

Technical Data
RATINGS AUXILIARY POWER SUPPLY CURRENT INPUT ENVIRONMENTAL CONDITIONS
Current Supply voltage : 220~240 V AC / Rated current ( In ) :5A Temperature : -5˚C to +55˚C
380~415 V AC Operating Limits : 0.05 A to 6.5 A Humidity : 56 days at 93% RH and
Operating Limits : -15% + 10% Rated Frequency : 50 Hz or 60 Hz 40˚C non-condensing
Consumption : 10 VA max
PFR 140 / 120 / 80 / 60

Rated frequency : 50 Hz or 60 Hz
CONTROL RANGE MECHANICAL
Power factor setting : 0.8 Ind - 0.8 Cap Mounting : Panel mounting
OUTPUT CONTACTS C/K setting : 0.03 - 1.20 / Automatic Dimension (mm) : 144(w) x 144(h) x 90(d)
Numbers of outputs : 6 / 8 / 12 / 14 ( PFR60 Switching sensitivity : 5 - 600 s/step Enclosure protection : IP54 at the panel
/ PFR80 / PFR120 / Reconnection time for Approximate weight : 1.2 kg
PFR140 ) same step : 5 - 240 s
Rated voltage : 250 V AC THD threshold : 0.20 - 3.00 ( 20% - 300% ) /
Contact rating : 5A OFF
Expected electrical life : 100,000 operations at Switching Program : Automatic / Automatic
rated current Rotate / 4-quadrant /
Expected mechanical life : 5 x 106 operations Manual
Max current for the Rated step coefficient : 0 / 1 / 2 / 3 / 4 / 5 / 6 / 8 /
common terminals : 12 A continuous 12 / 16
( Automatic if C/K set to
Auto )
Power Factor Regulator

Typical Application Diagram

MAIN
N L3 L2 L1
13 13

220~240 V AC
AUX AUX

380~415 V AC
VOLTAGE 1 VOLTAGE
14 14
2

Power Factor Regulator


1
15 2 3 15
16 3 4 16
P1 17 5
CURRENT 4
18 6 For 220~240 V AC Model Only
/5A 5
P2 19 6 7
20 11 7 8
21 12 8 9
22 13 9 10
23 14 10 11
24 12
FUSE

K14 K13 K2 K1

LOAD

Ordering Information Case Dimensions


144 mm

MODEL DESCRIPTION
PFR60 - 415 - 50 6 Steps, 50 Hz system, auxiliary voltage 380~415 V AC
144 mm

PFR80 - 415 - 50 8 Steps, 50 Hz system, auxiliary voltage 380~415 V AC Front


PFR120 - 415 - 50 12 Steps, 50 Hz system, auxiliary voltage 380~415 V AC
PFR140 - 415 - 50 14 Steps, 50 Hz system, auxiliary voltage 380~415 V AC
PFR60 - 220 - 50 6 Steps, 50 Hz system, auxiliary voltage 220~240 V AC
PFR80 - 220 - 50 8 Steps, 50 Hz system, auxiliary voltage 220~240 V AC 90 mm
76 mm
PFR120 - 220 - 50 12 Steps, 50 Hz system, auxiliary voltage 220~240 V AC
PFR 140 / 120 / 80 / 60

PFR140 - 220 - 50 14 Steps, 50 Hz system, auxiliary voltage 220~240 V AC


PFR60 - 415 - 60 6 Steps, 60 Hz system, auxiliary voltage 380~415 V AC
Side
PFR80 - 415 - 60 8 Steps, 60 Hz system, auxiliary voltage 380~415 V AC
PFR120 - 415 - 60 12 Steps, 60 Hz system, auxiliary voltage 380~415 V AC
PFR140 - 415 - 60 14 Steps, 60 Hz system, auxiliary voltage 380~415 V AC
PFR60 - 220 - 60 6 Steps, 60 Hz system, auxiliary voltage 220~240 V AC
138 mm
PFR80 - 220 - 60 8 Steps, 60 Hz system, auxiliary voltage 220~240 V AC
PFR120 - 220 - 60 12 Steps, 60 Hz system, auxiliary voltage 220~240 V AC
PFR140 - 220 - 60 14 Steps, 60 Hz system, auxiliary voltage 220~240 V AC
138 mm

Panel
Cutout
Power Factor Regulator
PFR96
PFR96P
Features
• Microprocessor based intelligent auto
switching control

• Automatic C/K and rated step


adjustment

• Automatic CT polarity correction

• Display of power factor & current

• Programmable sensitivity

• Last step can be used as alarm/fan output

• Under/over voltage alarm, under/over


compensate alarm

For PFR 96 For PFR 96P • User-friendly setting

• For single-phase system • For 3-phase system • Complies with IEC 61000-6-2 standard

Technical Data
RATINGS AUXILIARY POWER SUPPLY CURRENT INPUT ENVIRONMENTAL CONDITIONS
Model PFR96 : 110 ~ 120 V AC / Rated current ( In ) :5A Temperature : -5˚C to +55˚C
220 ~ 240 V AC Operating Limits : 0.15 A to 6.5 A Humidity : 56 days at 93% RH and
Model PFR96P : 380 ~ 415 V AC Rated frequency : 50 Hz or 60 Hz 40˚C non-condensing
Operating Limits : -15% + 10%
Consumption : 10 VA max
Rated frequency : 50 Hz or 60 Hz CONTROL RANGE MECHANICAL
Power factor setting : 0.8 Ind - 0.8 Cap Mounting : Panel mounting
C/K setting : 0.03 - 1.20 / Automatic Dimension (mm) : 96(w) x 96(h) x 90(d)
OUTPUT CONTACTS Switching sensitivity : 5 - 600 s/step Approximate weight : 0.6 kg
Numbers of outputs : 6 Reconnection time for
Rated voltage : 250 V AC same step : 5 - 240 s
Contact rating : 5A Switching Program : Automatic / Automatic
Expected electrical life : 100,000 operations at Rotate / 4-quadrant /
PFR 96 / 96P

rated current Manual


Expected mechanical life : 5 x 106 operations Rated step coefficient : 0 / 1 / 2 / 3 / 4 / 5 / 6 / 8
Max current for the / 12 / 16
common terminals : 12 A continuous ( Automatic if C/K set to
Auto )
Power Factor Regulator

Typical Application Diagram


Diagram 1 - For model PFR96 Diagram 2 - For model PFR96P

MAIN MAIN
N L3 L2 L1 N L3 L2 L1

8 16 8 16
6 6
FUSE 15 FUSE
7 7 VOLTAGE 15
Power Factor

Power Factor
VOLTAGE 5
380~415
Regulator

6 14

Regulator
220 V AC / 4 6 14
V AC 4
5 110 V AC 13 5 13
3 3
4 12 4 12
2 2
P1 3 11 P1 3 11
CURRENT 1 CURRENT 1
2 /5A 10 2 10
/5A
P2 9 P2
1 1 9

FUSE FUSE

K1 K5 K6 K1 K5 K6

LOAD LOAD

Ordering Information Case Dimensions


96 mm
MODEL DESCRIPTION
PFR96 - 220 - 50 6 Steps, for 50 Hz system, auxiliary voltage 220~240 V AC
PFR96 - 220 - 60 6 Steps, for 60 Hz system, auxiliary voltage 220~240 V AC
96mm

Front
PFR96 - 110 - 50 6 Steps, for 50 Hz system, auxiliary voltage 110~120 V AC
PFR96 - 110 - 60 6 Steps, for 60 Hz system, auxiliary voltage 110~120 V AC
PFR96P - 415 - 50 6 Steps, for 50 Hz system, auxiliary voltage 380~415 V AC
PFR96P - 415 - 60 6 Steps, for 60 Hz system, auxiliary voltage 380~415 V AC 90 mm
70 mm

Side
PFR 96 / 96P

91.0 ± 0.5 mm
91.0 ± 0.5 mm

Panel
Cutout
Power Factor Regulator
PFRLCD
Features
• 2” inch, 64 x 128 dot matrix LCD display
with back lighting
• Three phase and single phase detection
of reactive power
• 12 (or 8 for 8 step model) output with
two additional
• Independent contact for signal alarm
output and fan output
• Three phase compensation mode
• 5 different switching program
• Automatic detection of C/K and rated
step value
Measurement Parameters • No Voltage release
• Active, reactive, apparent power • Up till 31st order Harmonics • Various configurable alarm settings
measurement in graphical and table
• Temperature format • Alarm linked signal contact
• Phase voltage and phase current • Power Factor and Displacement • Programmable fan control
Power Factor (Cosφ)
• Frequency • ModBus-RTU communication

Typical Application Diagram


PFRLCD Connection diagram for 3 Phase 12 Step model PFRLCD Connection diagram for 1 Phase 12 Step model
LOAD LOAD

K12 K2 K1 K12 K2 K1

FUSE FUSE

FUSE FUSE
SIG SIG
31 30 24 23 14 13 12 11 10 9 8 7 6 5 4 3 2 1 20 21 22
31 30 24 23 14 13 12 11 10 9 8 7 6 5 4 3 2 1 20 21 22

SIG SIG
32 44 43 42 41 40 39 38 37 36 35 34 33
32 44 43 42 41 40 39 38 37 36 35 34 33

N L
N L

FAN
AUX

FAN
AUX

FAN FAN
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
P2

N L1 L2 L3 S1 S2 S1 S2 S1 S2
CT3

PFR LCD
PFR LCD
P1
P2

PFR LCD
CT2
P1

P2
P2

N L1 L2 L3 In Out
CT1
CT1

P1
P1

N- N-
RS485 RS485
RP RP
Modbus Modbus
P+ P+
-RTU -RTU
GND GND
T1 T1
T2 Thermistor T2 Thermistor
L1
L2
L3
L1
L2
L3

N
N

PFRLCD120P3-230-50 PFRLCD120P1-230-50
Power Factor Regulator

Technical Data
CURRENT INPUT CONTROL RANGE DISPLAY
(EACH PHASE) Target Power factor : 0.80 Inductive – 0.80 %THDI & %THDV : 0 – 500%
Nominal Current : 5 A rms Capacitive Harmonics Resolution : Up till 31st Harmonics
Operating Limits : 0.01-10 A rms C/K setting : 0.03 – 1.20 / Automatic Active power : 0– 3000 W
Rated frequency : 50 Hz or 60 Hz detect Reactive power : 0 – 3000 VAR
Sensitivity : 5 - 300s / Step Apparent power : 0 – 3000 VA
VOLTAGE INPUT Reconnection time : 5 – 240s Voltage : 0 – 300 VAC
(EACH PHASE with respect to neutral) Switching program : Automatic/ Manual/ Current : 0.00 – 10.0 A rms
Nominal Voltage : 230 Vrms Four-quadrant/ Temperature : 0 – 100 °C
Operating Limits : 0 - 277 V L-N Rotational/ Linear Frequency : 45 – 65Hz
Consumption : 0.05 VA Rated step coefficient : 0/ 1/ 2/ 3/ 4/ 5/ 6/ 8/ 12/ Power Factor : -1.00 – 1.00
Rated Frequency : 50 Hz or 60 Hz 16/ Fixed Displacement Power Factor : -1.00 – 1.00
Catagory : III Detection mode : L1 / L2 / L3 / Max Load /
Three Phase ENVIRONMENT CONDITIONS
THERMISTOR INPUT Fan Setting : Fixed on / Output On / Temperature : -5°C to +55°C
Thermistor Temperature range : 0 – 100 °C Temperature / None Humidity : 56 days at 93%RH and
Signal Contact : Linked to 10 different 40°C non-condensing
programmable alarm / Pollution Degree : II
AUXILIARY
None Dielectric Withstand : IEC61010-1
Auxiliary Input Voltage Range : 85 - 265 Vrms
Consumption : 10 VA max Altitude : 2000 m
Rated Frequency : 50 Hz or 60 Hz ALARM SETTING RANGE
%THDI : 20 - 300% / OFF ELECTROMAGNETIC COMPATIBILITY (EMC)
Over Voltage : 253 – 264 V/ OFF Part 6-2: Generic standards : IEC61000-6-2
OUTPUT CONTACTS
Under Voltage : 195 – 204 V/ OFF Immunity for industrial
Number of outputs : 14 (model dependent)
Over Current : 5.50 – 7.00 A/ OFF environments
Rated voltage : 250 V AC
Under Current : 0.01 – 0.15 A/ OFF Part 6-4: Generic standards : IEC61000-6-4
Contact rating : 5A
Under Compensate : On / OFF Emission standard for industrial
Expected electrical life : 100,000 operations at
Over Compensate : On / OFF environments
rated current
*CT Polarity Error : On / OFF
Expected mechanical life : 5 x 106 operations
Step Error : On / OFF MECHANICAL
Temperature : 36 – 70 °C / OFF Mounting : Panel mounting
Dimension (mm) : 144(w) x 144(h) x 122(d)
Case Dimensions Enclosure protection : IP54 at the panel
IP20 at the body
144mm
Approximate weight : 1.2 kg
(for three phase model),
1 kg
144mm

(for single phase model)

Front View
Ordering Information
122mm
102mm

MODEL DESCRIPTION
PFRLCD120P3-230-50 12 Step, 3 Phase, 230Vrms, 50Hz Model
PFRLCD80P3-230-50 8 Step, 3 Phase, 230Vrms, 50Hz Model
PFRLCD120P1-230-50 12 Step, 1 Phase, 230Vrms, 50Hz Model
PFR LCD

Side View PFRLCD80P1-230-50 8 Step, 1 Phase, 230Vrms, 50Hz Model


138mm PFRLCD120P3-230-60 12 Step, 3 Phase, 230Vrms, 60Hz Model
PFRLCD80P3-230-60 8 Step, 3 Phase, 230Vrms, 60Hz Model
PFRLCD120P1-230-60 12 Step, 1 Phase, 230Vrms, 60Hz Model
138mm

PFRLCD80P1-230-60 8 Step, 1 Phase, 230Vrms, 60Hz Model

Panel Cutout

You might also like