FC722 Fire Control Panel: Building Technologies

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

FC722 Cerberus® PRO

Fire control panel


Series FS720 (MP1XS)

z Compact, prefabricated microprocessor-controlled fire control panel for the


connection of up to 252 addresses
z Fire control panel can be used as stand-alone version or networked
z Up to 16 stations such as fire control panels and fire terminals (in any ar-
rangement) can be connected in one network
z Integrated emergency operation function
z Redundant network node, degrade operation according to EN 54
z Fast Ethernet interface for heterogeneous network
z Integrated user-friendly operating unit
z Optional printer, key switch, LED indicators
z Slots for RS232, RS485 serial ports
z Emergency power supply for up to 72 h emergency power time
z Detection and automatic read-in (auto configuration) of all C-NET devices, pro-
viding immediate simple operation
z Processes signals from the Cerberus PRO FD720 detector series
z Floor repeater devices, alarm devices and mimic displays in the detector loop
(C-NET)
z Flexible programming of complex applications and controls
z Stored data can be uploaded via remote access
z Firmware download of all processor controlled control panel components

Building Technologies
Fire Safety & Security Products
System overview

Expansion to a complex fire detection system

The high-performance C-WEB makes it possible to network up to 16 FC722/724 fire


control panels and FT724 fire terminals together as required. The innovative redundant
network nodes not only set new standards in terms of failsafe characteristics but also
for high-speed data transfer.
In addition, an Ethernet connection is available at each station. This Ethernet connec-
tion enables a maximum of 4 stations (inclusive Central Access Point ‘CAP’) to be net-
worked together (not EN 54-compliant).

Î For details about system networking, please refer to product data sheet
A6V10227649.

2
Building Technologies
Fire Safety & Security Products
Characteristics

– The FC722 is a compact fire control panel with an integrated operating unit that can
process signals from FD720 devices.
– The control panel can be used as a stand-alone unit or in a network.
– The control panel can be programmed with the user-friendly Cerberus-Engineering-
Tool to create a system with great versatility.
– All detector lines are monitored for ground faults.
– Adaptation of the user text directly on the terminal or with the software engineering
tool.
– Up to 2000 events can be stored according to various criteria.
– Automatic summer/winter time change.
– Connection of Siemens Danger Management System via BACnet

Functional elements

Operating unit
The following are located on the operating unit:
– CPU module and the electronics for the operating unit
– Ethernet connection
– Slots for RS232, RS485 modules and networking modules (SAFEDLINK)
– Space for 'Kaba' or 'Nordic' key switch
– Space for event printer (except FC722-YZ)

Periphery board
The following are located on the periphery board:
– Connection terminals for C-NET loops, remote transmission (alarm, fault), horn
output, programmable control inputs/outputs, monitored alarm and fault output,
degrade supply, power supply
– Plug-in position for loop extension (C-NET)

Power supply 70 W or 150 W, emergency power supply


The power supply supplies the hardware and charges the batteries
– The batteries supply the emergency power in case of power failure

Housing
A pivoting mounting panel can be installed on the housing backplane to allow installa-
tion of:
– 1 fire brigade periphery module (for Germany)
– 1 sounder module (can also be mounted onto the U-rail TS35)

Configuration
The FXS7212 Cerberus-Engineering-Tool permits the system to be adapted to specific
customers' requirements.

Application ranges

The FC722 is ideally suited for applications, e.g. in workshops, hotels, etc. or when
networked as part of much larger applications.
The FC722 can be used by the flexible cross-linking possibilities however also for ex-
tensive systems.

3
Building Technologies
Fire Safety & Security Products
Operation

Each control panel has an integrated operating unit. Additionally the control panel can
be operated from another separate FT724 operator terminal.
Î For details and further information, please refer to product data sheet A6V10207898.

Overview of FC722 fire control panels

Housing (Standard) Housing (Comfort)


FC722-ZZ FC722-YZ FC722-ZA FC722-ZE
With 24 indicator groups With 48 indicator groups
with each one red + yellow LED with each one red + yellow LED

2 Loops 2 Loops
With power supply (70 W) With power supply (70 W)
Battery capacity max. 12 Ah Battery capacity max. 12 Ah

2 Loops 2 Loops
With power supply (150 W) With power supply (150 W)
Battery capacity max. 26 Ah Battery capacity max. 26 Ah

Expansion External printer


FH7202-Z3 FH7203-Z3 FTO2001-A1 DL3750+
Housing (Standard) Housing (Comfort) Event printer Matrix printer (Extern)
430 x 398 x 160 mm 430 x 796 x 160 mm RS232 interface
Empty housing for various applications

Can be installed in all


panels except RS232 module must be ordered
– FC722-YZ separately
RS232 module must be ordered
separately
e.g. for additional batteries,
operating add-on or Operating add-on
Event printer FCM7211-Y3
Space for batteries 48 indicator groups
2 x FA2003-A1 (7 Ah) or with each one red + yellow LED
2 x FA2004-A1 (12 Ah) or
2 x FA2006-A1 (26 Ah)
e.g. for additional batteries,
operating add-on or
Event printer For retrofitting
Space for batteries
2 x FA2003-A1 (7 Ah) or
2 x FA2004-A1 (12 Ah) or
2 x FA2005-A1 (17 Ah) or
2 x FA2006-A1 (26 Ah)

4
Building Technologies
Fire Safety & Security Products
Configuration of FC722 in housing (Standard)

19

1 21 11
2
4 7 8 5

16
3

6
17
15
9 10
18 14
12 13
14 20

16

Basic equipment Designation Notes


1 Rear (Standard) FHA2002-A1
2 Periphery board (2-loop) FCI2002-A1 Pos. 1-5 –> Basic equipment for each FC722-xx (Standard)
3 Power supply (70 W) FP2001-A1
4 Mains terminals on DIN mounting rail TS35 – Space for socket, relay modules, etc.
5 Operating unit FCM72xx-xx Combined operating unit and CPU, incl. cover
6 Space for batteries – 2 x 12 V / 7…12 Ah
Expansion
7 Relay module Z3B171 Relay for fire controls
8 Event printer FTO2001-A1 For event logging
Key switch (Kaba) FTO2005-C1
9 For operating access rights
Key switch (Nordic) FTO2006-B1
10 Mounting plate FHA2007-A1 E.g. for fire brigade peripheral
11 Loop extension (FDnet/C-NET) FCI2003-A1 For loop extension of 2 to 4, number of addresses remains the
same
12 RS485 module (isolated) FCA2002-A1 For peripheral devices with RS485 port
13 RS232 module (isolated) FCA2001-A1 For stations with RS232 port
14 Networking module (SAFEDLINK) FN2001-A1 For networking various stations
15 Repeater (SAFEDLINK) FN2002-A1 For the extension of the system bus C-WEB, max. 1 between 2
stations (mounting direct onto plane surface, onto a U-rail TS35 or
in housing FDCH221)
16 Sounder module FCA2005-A1 For split-up of 1 to 4 conventional horn lines
Battery (12V, 7Ah, VDS) FA2003-A1
17 For emergency power supply
Battery (12V, 12Ah, VDS) FA2004-A1
18 Fire brigade periphery module FCI2001-D1 For Germany (FBF, FSD, ÜE, FSE, ÖA, KL)
rd
19 19" mounting kit FHA2016-A1 For the installation in 3 party housings
License key L1 or FCA2012-A1 For Cerberus-Remote
20
License key (L2) FCA2013-A1 For Cerberus-Remote und BACnet
21 Cable kit (communication) FCA2014-A1 For flexible cable connections to the modules on the operating unit

5
Building Technologies
Fire Safety & Security Products
Configuration of FC722 in housing (Comfort)

19

21 1 11
7
8 5

16
21
2

18

9 3
14 12
13 14
20

4
15

6
17

16 22
8
18
10

Basic equipment Designation Notes


1 Rear (Comfort) FHA2003-A1
2 Periphery board (2-loop) FCI2002-A1 Pos. 1-5 –> Basic equipment for each FC722-xx (Comfort)
3 Power supply (SV 24V-150 W) V24230-Z6-A2
4 Mains terminals on DIN mounting rail TS35 – Space for socket, relay modules, etc.
5 Operating unit FCM72xx-xx Combined operating unit and CPU, incl. cover
6 Space for batteries – 2 x 12 V / 7… 26 Ah
Expansion
7 Relay module Z3B171 Relay for fire controls
8 Event printer FTO2001-A1 For event logging
Key switch (Kaba) FTO2005-C1
9 For operating access rights
Key switch (Nordic) FTO2006-B1
10 Mounting plate FHA2007-A1 E.g. for fire brigade peripheral
11 Loop extension (FDnet/C-NET) FCI2003-A1 For loop extension of 2 to 4, number of addresses remains the
same
12 RS485 module (isolated) FCA2002-A1 For peripheral devices with RS485 port
13 RS232 module (isolated) FCA2001-A1 For stations with RS232 port
14 Networking module (SAFEDLINK) FN2001-A1 For networking various stations
15 Repeater (SAFEDLINK) FN2002-A1 For the extension of the system bus C-WEB, max. 1 between 2
stations (mounting direct onto plane surface, onto a U-rail TS35 or
in housings FDCH221)
16 Sounder module FCA2005-A1 For split-up of 1 to 4 conventional horn lines

6
Building Technologies
Fire Safety & Security Products
Battery (12 V, 7 Ah, VDS) FA2003-A1
17 Battery (12 V, 12 Ah, VDS) FA2004-A1 For emergency power supply
Battery (12 V, 26 Ah, VDS) FA2006-A1
18 Fire brigade periphery module FCI2001-D1 For Germany (FBF, FSD, ÜE, FSE, ÖA, KL)
rd
19 19" mounting kit FHA2016-A1 For the installation in 3 party housings
License key L1 or FCA2012-A1 For Cerberus-Remote
20
License key (L2) FCA2013-A1 For Cerberus-Remote and BACnet
21 Cable kit (communication) FCA2014-A1 For flexible cable connections to the modules on the operating unit
22 Power supply kit (150 W, B) FP2005-A1 For additional power supply

Technical data

FC722 in housing (Standard) FC722 in housing (Comfort)


Mains voltage 85… 265 VAC 230 VAC
Power supply 70 W 150 W
Operating voltage 21… 28.6 VDC 21… 28.4 VDC
Operating current max. 2.5 A max. 5 A
Battery capacity 2 x 12 V, 7… 12 Ah 2 x 12 V, 26 Ah
Battery monitoring yes yes
Mains monitoring yes yes
Connectable detector series Cerberus PRO FD720 (C-NET) Cerberus PRO FD720 (C-NET)
Number of lines
– Loops (with loop extension) or 2 (4) 2 (4)
– Stub lines 4 (8) 4 (8)
Number of addresses max. 252 max. 252
Integrated inputs/outputs
– Relay output
– Remote transmission alarm 1 1
– Remote transmission fault 1 1
– Monitored outputs
– Alarm 1 1
– Fault 1 1
– Horn 1 1
– Free programmable inputs/outputs 8 8
Operating unit integrated integrated
Plug-in position for serial interfaces RS232, 2 2
RS485
Plug-in position for network module 2 2
Plug-in position for loop extension 1 1
Mounting place for cable kit (communication) 1 2
Sounder module max. 1 max. 1
Ethernet connection RJ45 1 1
Operating temperature -8… +42 °C -8… +42 °C
Storage temperature -20… +60 °C -20… +60 °C
Humidity (no condensation permitted) ≤95 % rel. ≤95 % rel.
Dimensions (B x H x T) 430 x 398 x 160 mm 430 x 796 x 160 mm
Color
– Housing grey, ~RAL 7035 grey, ~RAL 7035
– Cover grey, ~RAL-Design 050 00 00 grey, ~RAL-Design 050 00 00
Protection category (IEC 60529) IP30 IP30
Approvals
– VdS G209076 G209076
– LPCB pending pending

7
Building Technologies
Fire Safety & Security Products
FC722

Details for ordering

Type Part no Designation Weight


Fire control panels FC722-ZZ S54400-C29-A5 Fire control panel (2L) 10.660 kg
FC722-YZ S54400-C29-A4 Fire control panel (2L, 1LED) 10.500 kg
FC722-ZA S54400-C29-A2 Fire control panel (2L) 18.250 kg
FC722-ZE S54400-C29-A1 Fire control panel (2L, 2LED) 20.850 kg
Expansion Z3B171 BPZ:4843830001 Relay module 250 VAC / 10 A (1 relay) 0.042 kg
FTO2001-A1 A5Q00010126 Event printer 0.250 kg
– A5Q00017619 Replacement printer rolls (10 rolls) 0.090 kg
FTO2005-C1 A5Q00010113 Key switch (Kaba) 0.013 kg
FTO2006-B1 A5Q00010129 Key switch (Nordic) 0.050 kg
FHA2007-A1 A5Q00010151 Mounting plate 0.800 kg
FCI2003-A1 A5Q00010136 Loop extension (FDnet/C-NET) 0.064 kg
FCA2002-A1 A5Q00009923 RS485 module (isolated) 0.067 kg
FCA2001-A1 A5Q00005327 RS232 module (isolated) 0.068 kg
FN2001-A1 A5Q00012851 Network module (SAFEDLINK) 0.077 kg
FN2002-A1 S24236-B2502-A1 Repeater (SAFEDLINK) 0.154 kg
FCA2005-A1 A5Q00014866 Sounder module 0.140 kg
FCA2014-A1 A5Q00023027 Cable kit (communication) 0.224 kg
FCI2001-D1 A5Q00013100 Fire brigade periphery module 0.482 kg
FH7202-Z3 S54400-B70-A101 Housing (Standard) 7.500 kg
FH7203-Z3 S54400-B71-A101 Housing (Comfort) 15.000 kg
FCM7211-Y3 S54400-F75-A1 Operating add-on (2xLED-ind.) 2.600 kg
FHA2016-A1 A5Q00020179 19" mounting kit 3.000 kg
Additional power supply FP2003-A1 A5Q00016005 Power supply kit (70 W) 0.650 kg
FP2004-A1 A5Q00020825 Power supply kit (150 W) for installation 1.366 kg
in empty housing
FP2005-A1 A5Q00018779 Power supply kit (150 W, B) ) for cascad- 1.100 kg
ing
Batteries FA2003-A1 A5Q00019353 Battery (12 V, 7 Ah, VDS) 2.450 kg
FA2004-A1 A5Q00019354 Battery (12 V, 12 Ah, VDS) 3.930 kg
FA2005-A1 A5Q00019677 Battery (12 V, 17 Ah, VDS) 5.640 kg
FA2006-A1 A5Q00019356 Battery (12 V, 26 Ah, VDS) 7.572 kg
Software license FCA2012-A1 A5Q00018856 License key (L1) 0.010 kg
FCA2013-A1 A5Q00018857 License key (L2) 0.010 kg
External printer DL3750+ A5Q00023962 Matrix printer (Extern) 7.300 kg
Spare part – A5Q00023963 Black typewriter ribbon for matrix printer 0.078 kg
DL3750+

Siemens Switzerland Ltd


Industry Sector
Building Technologies Division
International Headquarters © 2009 Copyright by
Fire Safety & Security Products Siemens Switzerland Ltd
Gubelstrasse 22
CH-6301 Zug Data and design subject to change without notice.
Tel. +41 41 724 24 24 Supply subject to availability.
www.siemens.com/buildingtechnologies
Document no. A6V10206525_b_en_-- Manual FS720
Edition 06.2009 Section 1

You might also like