Moduflex Valve System
Moduflex Valve System
Catalogue PDE2536TCUK
PDE2536TCUK
Moduflex Valve System - P2M
! WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY
DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical expertise. It is
important that you analyse all aspects of your application and review the information concerning the product or system in the current product catalogue. Due to the variety of operating conditions and applications for these
products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the
application are met. The products described herein, including without limitation, products features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at
any time without notice.
SALE CONDITIONS
The itms described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered into by Parker will be governed by the provisions stated in
Parker’s standard terms and conditions of sale (copy available upon request).
Summary...............................................................................................................................Page
V Series .............................................................................................................................. 16 - 19
P Series .............................................................................................................................. 26 - 27
T Series, Lockable connector IP67 and Clip connector IP40 & V Series ..................................... 29
P Series ..................................................................................................................................... 31
Maintenance ..................................................................................................................................... 33 - 34
Dimensions ....................................................................................................................................... 35 - 41
V Series Innovative
V Series
The 6 patents awarded to the
Moduflex Valve System reflect that
innovation is core to the Parker
design process. Maintaining a clear
understanding of our customer’s
Multi wiring expectations has defined the
individuality of the Moduflex, and
Fieldbus & IO-Link clearly differentiated it as a leading
automation solution.
T Series
Adaptive
No other system can be adapted
so simply once specified. Unique,
captive fitting release system,
quick release electrical connectors
and single mechanical screw
Lockable Connector IP67 connection between manifolds
Clip Connector IP40 offer the ultimate capability for late
system design changes.
S Series Multi-Functional
From stand-alone valves to
fieldbus ready valve islands, from
cylinder flow controls to vacuum
generators with integrated blow-
off, the Moduflex Valve System
meets the requirements of the
Lockable Connector IP67
whole automation spectrum.
Clip Connector IP40
Light-weight
P Series An As-i compatible valve manifold
with 8 electrical inputs and 8
pneumatic outputs weighs a mere
800grams, making the Moduflex
Valve System the perfect choice
for end of arm tooling application.
Vacuum
generator Pressure regulation
module
With high performance technology, Moduflex opens a new era in the field of electro-pneumatic automation.
Valves are easily assembled into compact islands that conform to any application requirement.
Adaptive pneumatic
. Manual overrides are also adaptive: locking for set up, or long valve island straight or elbow
non-locking for production. pneumatics connectors
Valve symbol
4
and 2 2 4
MAN 4 2 LED
Island with LED LED MAN MAN Island with
traditional 5/2 Moduflex 4/2
spool valves: slides valves:
Before any Each marking,
action, LED and LED and MAN
MAN have to be line up with the
carefully related to corresponding
the corresponding output.
output.
Man-machine
Man-machine dialogue is easy.
dialogue is difficult.
Adaptive design
individual electrical connector
Lockable M8 Connector - IP67 or Clip Connector - IP40
or Valve Bank with integrated 3 valves sizes in the same valve bank
IP65 electrical connections
Typical cylinder speeds are shown on next pages. Module size, tube diameter and length, cylinder size, load and exhaust collection are taken into account.
The charts below give the cylinder working speeds at 6 bar, under different conditions:
- non loaded or 50 % loaded double acting cylinder;
- exhaust piped through 2 m. long tubing, or exhaust muffled.
Field of application :
WCS
Wear Compensating System
Visualisation LED's
Pneumatic valve body For easy man-machine dialog
24 V DC solenoid valve
M8 - 3 pins for lockable
connector - IP67
For traditional wiring
Pneumatic symbol
4 mm orientable
push-in fitting
Locking system For pneumatic
for clip-on fittings remote pilot
Internal connection
Up to 19 solenoids
Associating tie-rod
For easy module assembly
Straight or elbow clip-on push-in fittings Auxiliary channels
For size 1: 4 or 6 mm OD tubing Independent pilot pressure
For size 2: from 6 to 12 mm OD tubing and exhaust
Electrical specifications
Technical characteristics
Vacuum module
Fluid Materials
Compressed air or inert gas, filtered 40µ mini., not lubricated
Body: Polyamide 6,6 reinforced fibreglass
Working pressure
1 to 8 bar Poppet: Nitrile
Pressure sensor
Fluid Materials
Air or inert gas, filtered 40µ mini., not lubricated
Body: Polycarbonate
Working temperature
0°C to +50°C
Supply
10,8 to 30 V DC
Digital output
PNP 125 mA
Connection drawing
Electrical or pneumatic
actuated valves Pressure sensor
Vacuum generator
3/2 blow-off 2 2
1 2 Vacuum cup
Blow-off
reservoir
Check
1 3 valve Speed
control
3/2 vacuum
Double check 3
Exhaust
4 valve
1 Venturi
Specific characteristics
Vacuum flow
Flow: 25Nl/min at 0 % vacuum and 6,5 bar
Evacuation time in s/l to reach different vacuum levels % (at P = 6,5 bar)
Vacuum % 0 10 20 30 40 50 60 70 80 90
Time in s 0,0 / 0,0 0,3 / 0,3 0,4 / 0,5 0,8 / 0,9 1,4 / 1,5 2,0 / 2,2 2,7 / 3,2 3,7 / 4,9 5,9 / 9,8 10,7 / -
Flow in NI/min 24,9 / 23,2 22,1 / 20,3 19,3 / 17,3 16,6 / 14,4 13,8 / 11,5 11,0 / 8,5 8,2 / 5,6 5,5 / 2,7 2,7 / 0,0 0,0 / -
Performances
Flow in Nl/min
Flow Nl/min
W
ith
W si
ith le
ca nc
pt er
ur
ed
ex
ha
us
t*
* 1 m exhaust - tube Ø6 mm
3 m exhaust - tube Ø8 mm
Operating information
Dual 4/2 Dual 3/2 3/2 4/2
Working pressure -0,9 to 8 bar
Pilot pressure 3 to 8 bar *
Size 1 Qmax. 275 l/min 415 l/min 415 l/min 510 l/min
Working temperature -15 °C to 60 °C
Protection individual M8 connectors IP 67 NEMA4 Qn 165 l/min 235 l/min 235 l/min 310 l/min
Protection individual clip connector IP40
Protection integrated connectors IP 65 Size 2 Qmax. - 805 l/min 805 l/min 1340 l/min
Voltage 24 V DC
Qn - 450 l/min 440 l/min 800 l/min
* Single and double 3/2 3,5 to 8 bar
In addition to the complete product adaptability, the Moduflex valve 1 - Basic modules ordering
range offers ordering flexibility for V, T, S and P series with 3 different
designs; from all components separately ordered (basic module) to Using this option, all basic components are separately
pre-assembled and tested valve island. ordered :
Stand-alone
valve module
Peripheral
2 - Complete modules ordering
module
Using this option, modules are defined, ordered and
supplied, pneumatic connectors and electrical
connection equiped. One part number defines:
- Function module
- Pneumatic connectors, muffler and plugs
- Electrical connection and cable
T series
V series
Tail
Island head Valve island assembly plate
module assembly
Pneumatic
head
module
LED
Island mounting and marking for easy man / machine dialog
Labelling Torx T8 screw driver
Manual (order code : P2M1K0TASD)
Field bus Multi-connector head module: Valve modules Valve module Intermediate Tail
head module: . guillotine, width: 47 mm size 1: size 2: module: plate:
. width: 94 mm . sub-D 25, width: 56 mm . width: 25 mm . width: 37.5 mm . width: 25 mm . width: 16 mm
Size 2 2 x 3/2 NC + NO 106 P2M1VEEE2CV P2M2VEEE2CV
115
with exhaust check valves
Valve island pneumatic 64 P2M2HXT01
head and tail module set
P2M2HXT01
Valve island intermediate 68 P2M2BXV0A
supply module with a set
of 4 configuration plates
P2M2BXV0A
V series valve island: Electrical field bus head modules for AS-i protocol
V series valve island: Electrical field bus head modules for device bus
Electrical modules for 16 outputs
(The V series modules may have up to 16 solenoid pilot valves)
Description Bus Protocol Bus In / Bus Out Power supply Weight (g) Order code
InterBus-S M23 - 9 Pins M12 - A coding 300 P2M2HBVS11600
Power
supply female All M12 - A coding 25 P8CS1205AA
straight connector
DeviceNet M12 - B coding 25 P8CS1205AB
CANopen
P2M2HBVP21600
The Moduflex IO-Link Class A module can handle a Moduflex Valve bank having up to 19 pilot
solenoid valves.
Thanks to its 2 x M12 A codded male connectors, it can be connected to any IO-Link Class A masters
and separately receive its auxiliary power supply for valves from an independent source.
The Moduflex IO-Link Class A module exists in 3 versions with the Auxiliary Power M12 connector
pin out adapted to any sourcing through a standard M12 cable:
• P2M2HBVL12400A13 version: 24 Vdc / 0 Vdc on pins 1 & 3 – Standard version
• P2M2HBVL12400A43 version: 24 Vdc / 0 Vdc on pins 4 & 3 – Compatible with Siemens wiring
• P2M2HBVL12400A42 version: 24 Vdc / 0 Vdc on pins 4 & 2 – Compatible with Rockwell wiring
The Moduflex IO-Link Class B module can handle a Moduflex Valve bank having up to 19 pilot
solenoid valves.
Thanks to its single M12 A codded male connectors, it can be connected to any IO-Link Class B
masters receiving its auxiliary power supply for valves on pins 2 & 5 from the only cable simplifying the
connection.
Diagnostic
The Moduflex IO-Link module offers a local diagnostic through 4 LED’s located on the visible top
side, showing:
• IO-Link com status
• Module error
• Output error
• Auxiliary power
Additionnal useful diagnostic information can be read by the PLC through the network simplifying
diagnostic and allowing predictive maintenance (all details in the user manual)
IODD file can be downloaded from IODD Finder or the Moduflex web site:
https://ioddfinder.io-link.com
www.parker.com/pde/io-link
Accessories
LED
Labelling Torx T8 screw driver
M8 lockable Island mounting
Manual (order code : P2M1K0TASD)
connector and marking for override
Clip IP67
easy
connector man / machine
IP40
dialog
In its IP40 version, each solenoid shows Clip 3 mm dia.
connection integrating LED and voltage surge
maxi.
protection. The clip connector with flying leads
may be ordered separately with independent or Island assembly with
interconnected common. a single screw per module
In its IP67 version, each solenoid shows a M8
connection. Lockable connectors, IP67 protected,
with LED voltage surge protection and flying lead
cable may be ordered for the required length. Modules and island ordering
Choice between 3 approaches: 2 - Complete modules ordering:
2 - Air pilot valve modules 1 - Basic modules ordering: Page 27 shows the ordering chart for
The following page shows these modules modules supplied with their connectors.
supplied without connector, together with 3 - Assembled island ordering:
the choice of clip-on connectors separately Page 30 shows the valve island configurator
4 mm supplied (10 units packs). This approach CD-Rom to specify a valve island that may be
OD tube gives the maximum flexibility. delivered assembled.
Electrical connectors
M8 lockable Description Connector type Cable length W (g) Order code
connector
Individual lockable connector – IP67 M8 / 2 x Flying leads 2 meters 62 P8LS08L226C
Clip connector Including LED and surge protection 5 meters 155 P8LS08L526C
2 Flying leads 9 meters 180 P8LS08L926C
Clip connector – IP40 1 x Clip connector 1 meter 8 P8LW021C
Individual: Including 2 flying leads 2 meter 12 P8LW022C
Multiple: Including 1 common (0 Vdc) 2 x Clip connectors 1 meter 12 P8LW021C02
and 1 flying lead per connector 4 x Clip connectors 1 meter 20 P8LW021C04
8 x Clip connectors 1 meter 36 P8LW021C08
Straight cable quick connect to thread M8 12 P8CS0803J
connector, IP67 protected M12 15 P8CS1204J
As an alternative to electrical controls, valves with air pilots are also available,
to be controlled by individual pneumatic signals.
Electrical connectors
M8 lockable Description Connector type Cable length W (g) Order code
connector
Individual lockable connector – IP67 M8 / 2 x Flying leads 2 meters 62 P8LS08L226C
Clip connector Including LED and surge protection 5 meters 155 P8LS08L526C
2 Flying leads 9 meters 180 P8LS08L926C
Clip connector – IP40 1 x Clip connector 1 meter 8 P8LW021C
Individual: Including 2 flying leads 2 meter 12 P8LW022C
Multiple: Including 1 common (0 Vdc) 2 x Clip connectors 1 meter 12 P8LW021C02
and 1 flying lead per connector 4 x Clip connectors 1 meter 20 P8LW021C04
8 x Clip connectors 1 meter 36 P8LW021C08
Straight cable quick connect to thread M8 12 P8CS0803J
connector, IP67 protected M12 15 P8CS1204J
Pressure regulator
The thrust developed by a cylinder often requires adjustment by controlling Pressure regulator may be equiped
the pressure to the front or back of the piston. This pressure regulator with a pressure gauge or without, thus
ready for a
module enables manual adjustment of pressure on one side of the piston,
clip-on
with visual indication provided by the pressure gauge. connection
to a remote
clip-on gauge
gauge
Vacuum generator
Vacuum Vacuum Blow-off
This multi-purpose module controls vacuum pads with a choice between
two basics schematics:
- Controlled with only one 3/2 NC valve, the vacuum generator Control valves
provides vacuum to the pads during valve actuation and then
blow-off supplied from an integrated chamber.
- Controlled with a double 3/2 NC + NC, the vacuum generator
provides vacuum during the first valve actuation, and then strong
blow-off from the second valve.
Integrated blow-off flow controller. Optional plug-in vacuum sensor.
Vacuum pads
Peripheral
module
To
cylinder
Plug-in
Peripheral modules may either be mounted: peripheral Plug-in
- Plugged into the valve module through double male unions; module peripheral In -line
size 1 module
- Or in line, close to the cylinder to control it better. peripheral
size 2 module
size 1
Exception:
Peripheral module
Valve A peripheral module cannot be plugged onto
close to cylinder
module a double 4/2 valve module. In -line
With this type of valve, use in-line installation peripheral
To module
only.
cylinder size 2
Clip-on accessories
Description Connection Pressure range Weight (g) Order code
Electrical
Complete module ordering, as compared to basic module ordering clip-on
connectors
V series
See opposite page for complete module order code chart
Multi-connectors or fields bus electrical head modules Size 1 Size 1 Size 1 Size 2
to be ordered from pages 18 and 19 2x4/2 4/2 solenoid spring 4/2 double solenoid 4/2 double solenoid
P2M1VJEE2CV00F4 P2M1V4ES2CV00C6 P2M1V4EE2CV00F6 P2M2V4EE2CV00F0
S and P series
See page 28 and 29 for complete module order code charts.
Complete Moduflex modules, equipped with their electrical and pneumatic connectors, may be ordered.
To do so, use the below chart to define the complete module order codes.
Valve modules
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Minimum ordering
P 2M1 V 4 E E 2 C V 0 0 F 6 quantity: 10 pieces
Voltage
00 Pneumatic pilot
2C 24VDC
Complete Moduflex stand alone valves, equipped with their electrical and pneumatic connectors, may be ordered.
To do so, use the below chart to define the complete module order codes.
Stand alone valve modules
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Minimum ordering
P 2M1 S 4 E E 2 C V 5 A F 6 quantity: 10 pieces
Voltage
00 Pneumatic pilot
2C 24VDC
0 10 mm OD
Size 1 Size 1
4/2 solenoid spring 2x3/2 NC + NC
P2M1S4ES2CV5CC6 P2M1SDEE2CV2BC6
Outlets
2
E
3
4
1 P
Complete Moduflex peripheral module, equipped with their pneumatic connectors, may be ordered.
To do so, use the below chart to define the complete module order codes.
Dual flow control, dual pilot operated check valve, and pressure regulator peripheral modules
1 2 3 4 5 6 7 8 9 10 11 12
Minimum ordering
quantity: 10 pieces
P 2M1 P X F A J J F 6
P 2 M 1 P X V A F 6 A F 6 CMA
Minimum ordering
quantity: 10 pieces
Pressure & Blow-off port connectors Vacuum and Vacuum Sensor port connectors
F4 Straight 4 mm OD A 2 similar connectors
JJ Clip-on double male union A 2 clip-on male union
C4 Elbow 4 mm OD 1 connector on vacuum port
F4 Straight 4 mm OD B
1 plug on vacuum sensor port
C4 Elbow 4 mm OD A 2 push-in connectors F6 Straight 6 mm OD
1 Connector on Vacuum Port
F6 Straight 6 mm OD C6 Elbow 6 mm OD D
1 push-in connector 1 Dig/Ana Vacuum Sensor MPS-V34G-PCI
C6 Elbow 6 mm OD
B F1 Straight threaded 1/8"
F1 Straight threaded 1/8" 1 plug on blow-off port 1 Connector on Vacuum Port
C1 Elbow threaded 1/8" E
C1 Elbow threaded 1/8" 1 Analog Vacuum Sensor MPS-V8T-AG
Moduflex is totally flexible: islands may have up to 19 valves for the V Series and is not limited for the T series with a
choice of 3 valve sizes, depending on the required flow. Thus, each island has specific needs for the size of it pressure
supply and its exhaust collection.
pressure
plug
supply
exhaust
collection
Sizing recommendations
The 3 valve islands above present typical situations for sizing islands We would recommend the following:
pressure supply and exhaust collection.
- air supply connection at least equivalent to largest output tube
In a given island, valves do not deliver their flow at the same to cylinders;
moment. Thus, the number of valves in an island is not the major - exhaust collection at least twice the section area of the largest
factor to consider. More important is the size of the largest valve output tube to cylinders.
and of the largest output tubes to the cylinders.
For islands with high flows, the following options are possible:
- use tubes up to 12 mm OD or mufflers providing exhaust
ID section areas of standard tubings collection is not necessary;
2 x 4 mm: 3 mm² 5.5 x 8 mm: 24 mm² 10 x12 mm: 80 mm² - provide additional P and/or E connection ports by inclusion
2.7 x 4 mm: 6 mm² 6 x 8 mm: 28 mm² of intermediate supply modules, thus keeping tube size small.
4 x 6 mm: 12 mm² 7 x 10 mm: 40 mm² muffler: 100 mm²
At the machine commissioning stage, the supply and exhaust
8 x 10 mm: 50 mm² equivalent
connections can be easily modified until the required performance
is achieved.
Maintenance procedure
The latest generations of compact pneumatic valves have a when necessary the solenoid pilot, valve or connector can be
life expectancy which generally exceeds the equipment they easily replaced without removing the island base, as shown
control. Therefore, although maintenance is seldom required, below.
S and T
series
Please, use a
Torx T8 screw
driver. Also
possible to
use a 3.5 mm
screwdriver.
V series
With only one universal solenoid pilot Multi-function adaptable manual override
for all configurations, maintenance is
simple
24V DC is now a global standard for all machines.
Because all Moduflex valve and island configurations are 1 - push - 2 - push -
supplied with this unique solenoid pilot, maintenance release twist -
operations remain very simple. lock
isolation
fork
locking
P2M2K0FA
stop
Maintenance components
bistable 25 P2M1X4EE
double NO + NO 28 P2M1XCEE
double NC + NO 28 P2M1XEEE
single NC 25 P2M1X3ES
P2M1X4EE
4/3 CE double 3/2 NC + NC without exhaust check valve 28 P2M1XGEE
size 2 valve modules without solenoid pilot and without sub-base Weight (g) Order code
bistable 30 P2M2X4EE
double NO + NO 32 P2M2XCEE
double NC + NO 32 P2M2XEEE
single NC 28 P2M2X3ES
Head Dual
Module Intermediate Module Tail
module 4/2
- - - - : sub-D 25 size 1 module size 2 plate
module
2 screws
4 mm dia.
surface
mounting
sub-D 25 or
2 mounting holes 4.3 mm dia DIN rail DIN rail 35x7 mm or 35x15 mm
mounting
Pneumatic
Electrical field head Module Intermediate Module Tail
bus head module module size 1 module size 2 plate 2 screws
4 mm dia.
surface
mounting
or
DIN rail
mounting
Pneumatic Dual
head 4/2 Module Intermediate Module Tail
module module size 1 module size 2 plate
2 screws
4 mm dia.
surface
mounting
Stand-alone
valve
size 2 Lockable connector or side mounting with
2 screws 4 mm dia. With Lockable connector
Clip connector
With Clip connector
Reminder: peripheral modules may either be plugged in the valve output ports or mounted in line separate from the valve
- with gauge
- without gauge
possible mounting
with 2 screws
3 mm dia.
- without gauge
possible mounting
with 2 screws
Dual P.O. check valve module size 2 3 mm dia.
25 39.5
13.5 15.5
47
16.6
37.5
80.6
32.8 24.7
40.8
34 68
26 15.5
12.5 7.2
20.7
32.6
26.5
15
27
34.8
140
16.6
27.5
33 4.5 24.7
41
Recommendations for building machines with imperial OD tubes (US usual standard)
size 1 modules Moduflex is a global product available in the US with the two standards
that are commonly used in this country:
- metric OD tubes with the metric connectors shown in this catalogue,
- imperial OD tubes with specific connectors for the US.
Such components will easily be obtained with the 2 - Select from the list below the clip-on
following procedure: connectors for the required imperial OD tubes.
1/4’’, 5/16’’, 3/8’’ or 1/2’’
OD tube
1 - select the required basic modules (with no Push-in the connectors into the basic modules
connector). 3 - ports in order to obtain complete modules.
FMD04-1
FMD07-1 elbow version straight version
pneumatic connectors for size 1 modules Pack Weight Order Weight Order
Quant. (g) per unit code (g) per unit code
guillotine
lock
fool proof
positioner
multi-
connector
solenoid pilot position into the island
Multi-connector addressing
When assembling a V series island, modules are The colour code addressing given below
Ø 8.6 mm automatically connected to the head module conforms to the DIN 47100 standard.
through the modular principle of the integrated
electrical connections. To each wire colour code corresponds a solenoid
pilot position in the island.
Sub-D 25 addressing
Pin Pin
Address Number Number Address
Not used
Not used
Not used
Not used
Not used
Common
IO-Link
Class B Class A
+24 Vdc
1 1 1 +24 Vdc 1
For compatibility with a safe output pulsed C/Q
4 2
+24 Vdc
C/Q
4 2
+24 Vdc
N.C.
4
N.C.
4
1s
50% 50%
10% 90%
1s
50% 50% Supply
diagnostic functionalities, please refer to IO-Link Communication Module Diagnostic Outputs (valves)Diagnostic Auxiliary Power Supply
the User Manual available from the product
web page:
www.parker.com/pde/io-link
Inside the bus module, solenoid valve control is protected - The solenoid pilot power supply indicator, green
against short-circuits, with the following visual indication when supply is OK.
provided: - The red LEDs detecting solenoid valve short-circuits
with code shown above.
Addressing
Use the .GSD file on Moduflex web site:
www.parker.com/pneu/moduflex
The coding wheels enable configuration
of the decimal address.
Diagnostic equipment
adress 1-99
1 : drains
2 : V+
Bus cable connections 3:V-
4 : CAN-H
DeviceNet standard male and female type A M12 5 : CAN-L
M12 male M12 femelle
connectors. A type
A type
The supply for the module is supplied from the
V+ and V- (24 V DC) of «bus in» connector.
Use of prefabricated cables available from your
usual electrical supplier is recommended. bus active bus communication error
Line termination, P8BPA00MA, is necessary on the solenoid pilot diagnostic
«bus out» connector of the last station.
Addressing
Use the .EDS file on Moduflex web site:
www.parker.com/pneu/moduflex
The coding wheels enable configuration
of the decimal address.
Diagnostic
Diagnostic according to the module equipment bus speed: 125 K baud, 250 K baud, 500 K baud
dialogue shown on the illustration. MAC ID 1-63
1 : drains
2 : V+
3:V-
Bus cable connections 4 : CAN-H
CANopen standard male and female type A M12 M12 male 5 : CAN-L M12 female
connectors. A type A type
The supply for the module is supplied from the V+
and V- (24 V DC) of «bus in» connector.
Use of prefabricated cables available from your
usual electrical supplier is recommended. bus active bus communication error
Line termination, P8BPA00MA, is necessary on the solenoid pilot diagnostic
«bus out» connector of the last station.
Addressing
Use the .EDS file on Moduflex web site:
www.parker.com/pneu/moduflex
The coding wheels enable configuration
of the decimal address.
Diagnostic
bus speed: 20 K baud, 125 K baud, 250 K baud
Diagnostic according to the module dialogue equipment Other: auto-detection 10 K baud to 1 M baud
shown on the illustration. MAC ID 1-63
Bus cable connections bus in pin out bus out pin out
(as seen on module) (as seen on module)
1: D0 1: D0
The M23 connectors conform to «Interbus
remote bus». 2: D0 2: D0
3: DI 3: DI
Use of prefabricated cables available from your 4: DI 4: DI
electrical usual supplier is recommended.
5: ground 5: ground
6: NC 6: NC
Automatic Addressing 7: NC 7: NC
InterBus-S is self addressing. Thus it does not need 8: NC 8: NC
any software or hardware configuration. M23 male 9: NC M23 female 9: RBST
Manual Addressing Note: for more details please consult «Interbus remote bus» documentation
Diagnostic
Diagnostic according to the module dialogue
shown on the illustration.
This diagnostic conforms to the InterBus-S
standard.
Bus diagnostic
second node Power supply sol. pilot supply normal operation solenoid overload
first node
green red green red
first node LEDs state second node LEDs state System condition
green LED red LED green LED red LED
Normal operation
6 7
No module + sensor supply
Input overload
No AS-i communication
Input wiring
Physical input ( I, II, III, IV ) = D (0 1 2 3) first node, physical input ( V, VI, VII, VIII ) = D (0 1 2 3) second node
Examples : physical input III = logical input 6.2, physical input V = logical input 7.0
M8 female connectors M12 female connectors
pin out
1 - 24 V DC / AS-i
2 - second input
pin out 3 - 0 V DC / AS-i
1 - 24 V DC / AS-i 4 - first input
3 - 0 V DC / AS-i 5 - not connected
4 - input
Note : with only one node, the inputs
II and IV are connected to the
connections on the right.
With local inventories reduced to the modules and connectors shown here, any local distributor,
machine manufacturer or user easily obtains the valve island or stand-alone that he needs and will
then completely master any evolution required by the machine commissioning.
Note : the functional poster proposed below reproduces this illustration at A1 format (60 x 84 cm).
1
Electrical field bus head modules ASi Std 4O í P2M2HBVA10400
Island head and intermediate module sets Size 2
4O/4I M12 í P2M2HBVA10404B
8O í P2M2HBVA10800 V series T series
8O/8I M8 í P2M2HBVA10808A
Valve island pneumatic head and tail
8O/8I M12 í P2M2HBVA10808B
module set
P2M2HXT01 P2M2HXT01
ASi v 2.1 6O í P2M2HBVA20600
6O/8I M8 í P2M2HBVA20608A
6O/8I M12 í P2M2HBVA20608B Valve island intermediate supply module
P2M2BXV0A P2M2BXT0A
with a set of 4 configuration plates
ProfiBus DP 160 í P2M2HBVP11600
DeviceNet 160 í P2M2HBVD11600
CANopen 160 í P2M2HBVC11600
Electrical connectors
InterBus S 160 í P2M2HBVS11600
Description Connector type Cable length
IO-Link A 24DO í P2M2HBVL12400A13 M8 lockable
IO-Link A 24DO í P2M2HBVL12400A42 connector Individual lockable connector – IP67 2m P8LS08L226C
IO-Link A 24DO í P2M2HBVL12400A43 Including LED and surge protection M8 / 2 x Flying leads 5m P8LS08L526C
Electrical multi-connector head module IO-Link B 24DO í P2M2HBVL12400B25 2 Flying leads 9m P8LS08L926C
Description Protection Cable length 1 x Clip connector 1m P8LW021C
Guillotine type Multi-connection head module P2M2HEV0A Clip connector – IP40 2m P8LW022C
Individual : Including 2 flying leads
Guillotine connector 2m P8LMH20M2A Clip connector 2 x Clip connectors 1m P8LW021C02
Multiple : Including 1 common (0 Vdc)
with flying leads IP65 5m P8LMH20M5A 4 x Clip connectors 1m P8LW021C04
and 1 flying lead per connector
multi-cable 9m P8LMH20M9A 8 x Clip connector 1m P8LW021C08
Multi-connection head module P2M2HEV0D
Standard Sub-D 25 P8CS0803J Straight cable quick connect to M8 P8CS0803J
Sub-D 25 connector 3m P8LMH25M3A
type IP40 P8CSY1212A thread connector, IP67 protected M12 P8CS1204J
with flying leads 9m P8LMH25M9A
« Y » shape M12 Male - 2 x M12 Female P8CSY1212A
multi-cable IP65 9m P8LMH25B9A
2
150 400 1200 24 V P= - 0.9 bar / +8 bar
NI/mn NI/mn NI/mn
Size 1 Size 2
IP65 IP67 IP40 IP65 IP67 IP40
V T S T S V T S T S
25mm 25mm 37.5mm
P2M1V4ES2CV P2M1T4ES2C P2M1S4ES2C P2M1T4ES2CW P2M1S4ES2CW P2M2V4ES2CV P2M2T4ES2C P2M2S4ES2C P2M2T4ES2CW P2M2S4ES2CW
Size 1
4/2 P2M1V4EE2CV P2M1T4EE2C P2M1S4EE2C P2M1T4EE2CW P2M1S4EE2CW P2M2V4EE2CV P2M2T4EE2C P2M2S4EE2C P2M2T4EE2CW P2M2S4EE2CW
P2M1VDEE2CV P2M1TDEE2C P2M1SDEE2C P2M1TDEE2CW P2M1SDEE2CW P2M2VDEE2CV P2M2TDEE2C P2M2SDEE2C P2M2TDEE2CW P2M2SDEE2CW
P2M1VCEE2CV P2M1TCEE2C P2M1SCEE2C P2M1TCEE2CW P2M1SCEE2CW P2M2VCEE2CV P2M2TCEE2C P2M2SCEE2C P2M2TCEE2CW P2M2SCEE2CW
3/2 P2M1VEEE2CV P2M1TEEE2C P2M1SEEE2C P2M1TEEE2CW P2M1SEEE2CW P2M2VEEE2CV P2M2TEEE2C P2M2SEEE2C P2M2TEEE2CW P2M2SEEE2CW
Size 2 P2M1V3ES2CV P2M1T3ES2C P2M1S3ES2C P2M1T3ES2CW P2M1S3ES2CW P2M2V3ES2CV P2M2T3ES2C P2M2S3ES2C P2M2T3ES2CW P2M2S3ES2CW
3 Optimal nominal section for a full flow with appropriate fitting Size 2 Size 1 Size 01
Clip-On pneumatic connectors Tube OD Size 1 Size 2
Nominal section 40 mm2 Nominal section 12 mm2 Nominal section 4 mm2
Straight connector G1/8 FMDG1-1
3 valve sizes lead to a Qn 1200 NI/mn* Qn 400 NI/mn*
Qn 150 NI/mn*
4mm FMD04-1
Qmax 1340 NI/mn* Qmax 510 NI/mn*
4
Basic peripheral modules (without connector) Size 1 Size 2 Clip-on accessories
Description Connection Pressure range
Dual flow control P2M1PXFA P2M2PXFA
0 to 4 bar P2M1K0GT
Clip-on pressure gauge for pressure
Clip-on 0 - 7 bar P2M1K0GL
regulator modules, size 1 or size 2
Dual P.O. check valve P2M1PXCA P2M2PXCA 0 - 11 bar P2M1K0GN
© 2017 Parker Hannifin Corporation. All rights reserved. Catalogue PDE2536TCUK - V7 - April 2017