Minimum design dead loads are specified for ceilings, floors, floor finishes, roof and wall coverings, frame walls, hollow concrete masonry units, wood joists, and more.

MEMBER WEIGHT

LL Kpa
WALL 3.8 Kpa
ROOF Kpa
Occupancy Use 0 Kpa
Topping & tiles= 0 Kpa l=1 16
Ceiling+ Services= Kpa l=2 13.2
Meachanical duct= Kpa
Partiton= 0 Kpa l=3 11.7
W= 1.2 Kpa l=4 9.68
l=5
TRIBUTARY AREA

A C
S
B D
L

AB/CD= WS/3
AC/BD= WS/6(3-M^2)
M= S/L
Slab 1
S= 6
L= 6
M= 1
AB/CD= 2.4 TOTAL Pu = for columns ( assumed base on weight assigned)
AC/BD= 2.4 1036.8 KN

4.5
6

at entrance
0.8607968

8.6079684

SOHAR MALL
*for mall sohar TOTAL UNFACTORED WEIGHT OF THE STRUCTURE =
TOTAL UNFACTORED WEIGHT OF THE STRUCTURE APPLIED =
thk
floor wt= 0.2 WEIGHT OF ROOF
4.7088 kpa
walls

NO. OF SUPPORTS 1408

LOAD PER COLUMN 863.28

for ski TOTAL UNFACTORED WEIGHT OF THE STRUCTURE =


for uniform loads TOTAL UNFACTORED WEIGHT OF THE STRUCTURE APPLIED =
s 9.255
l 11.23 WEIGHT OF ROOF

pu 1 3990.845 kn
pu 2 1338.46 kn
total columns
load per columns

*hotel and ballroom


pu= 1091.336 kn
s 11.055 TOTAL UNFACTORED WEIGHT OF THE STRUCTURE =
l 13.473 TOTAL UNFACTORED WEIGHT OF THE STRUCTURE APPLIED =
floor wt= 0.18
4.23792 kpa WEIGHT OF ROOF

0.18
4.23792 kpa
total columns
load per columns
TOTAL UNFACTORED WEIGHT OF THE STRUCTURE = 144113.328 KN
TOTAL UNFACTORED WEIGHT OF THE STRUCTURE APPLIED = 81785.16
TOTAL =

744481.875 KN
467380.25 KN

3637.116 KN

1,215,499.24

KN

180229.438 KN
86124.93 KN

KN

266,354.37

199
1,338.46

156270.469 KN
93942.031 KN

KN

250,212.50

112
2,234.04
URE = 144113.328 KN
URE APPLIED = 81785.164 KN
Table 204-2 Minimum Design Dead Load(Kpa) (Use actual loads when available)
MINIMUM DESIGN DEAD LOAD (Kpa)

CEILINGS FLOOR FILL


Acoustical Fiber Board 0.05 Kpa Cinder Conc per mm 0.017
Gypsum board(per mm thk) 0.008 Kpa Lightweight conc per mm 0.015
Mechanical duct allowance 0.2 Kpa Sand per mm 0.015
Plaster on tile or Conc. 0.24 Kpa Stone Conc per mm 0.023
Plaster on wood lath 0.38 Kpa
Suspended steel chamber channel 0.1 Kpa FLOOR AND FLOOR FINISHES
Wood furring Suspention System 0.12 Kpa asphalt block(50mm),13mm mortar 1.44
Cement finish(25mm) on stone conc. Fill
COVERING, ROOF & WALL Ceramic or Quarry tile(20mm) on 1.53
Asphalt shingles 0.1 Kpa 25mm Mortar bed
Cement Tile 0.77 Kpa Ceramic or Quarry tile(20mm) on 0.77
Clay tile(for mortal add 0.48KPa) 13mm Mortar bed
Book tile(50mm) 0.57 Kpa Ceramic or Quarry tile(20mm) on 1.1
Book tile(75mm) 0.96 Kpa 25mm Mortar bed
Ludowici 0.48 Kpa Conc. Fill finish(per mm thk) 0.023
Roman 0.57 Kpa hardwood flooring 22mm 0.19
Spanish 0.91 Kpa Linoleum or asphalt tile 6mm 0.05
Composition Marble & mortar on stone conc. Fill 1.58
Three-ply ready roofing 0.05 Kpa Slate(per mm thk) 0.028
Four-ply felt & gravel 0.26 Kpa Solid flat tile on 25mm mortar base 1.1
Five-ply felt & gravel 0.29 Kpa Subflooring 19mm 0.14
Copper or Tin 0.05 Kpa Terrazzo(38mm)directly on slab 0.91
Corr. Asbestos-cement roofing 0.19 Kpa Terrazzo(25mm)directly on stone conc. Fill 1.53
Deck metal 20Gauge 0.12 Kpa Terrazzo(25mm)50mm stone conc. 1.53
Deck metal 18Gauge 0.14 Kpa Wood Block(76mm)on mastic no fill 0.48
Fiberboard 13mm 0.04 Kpa Wood Block(76mm)on 13mm mortar base 0.77
Gypsum sheating 13mm 0.1 Kpa
Insulation,roof boards(per mm thk) FRAME WALLS
Cellular glass 0.0013 Kpa Exterior stud walls
Fibrous glass 0.0021 Kpa 50x100 @ 400mm,15mm gypsum,
Fiberboard 0.0028 Kpa insulated,10mm siding 0.53
Pertile 0.0015 Kpa 50x150 @ 400mm,15mm gypsum,
Polysterene Foam 0.0004 Kpa insulated,10mm siding 0.57
Urethane Foam w/ skin 0.0009 Kpa Exterior stud wall w/ brick veneer 2.3
Plywood(per mm thk) 0.006 Kpa Window glass,frame,& sash 0.38
Rigid Insulation(13mm) 0.04 Kpa Clay brick wythes:
Skylight,metal frame 10mm 100mm 1.87
wire glass 0.38 Kpa 200mm 3.8
Slate(5mm) 0.34 Kpa 300mm 5.5
Slate(6mm) 0.48 Kpa 400mm 7.42
Waterproofing membranes:
Bituminious,gravel-covered 0.26 Kpa
Bituminious,smooth-covered 0.07 Kpa
Liquid applied 0.05 Kpa
Single-ply sheet 0.03 Kpa
wood Sheating(per mm thk) 0.0057 Kpa
Wood Shingles 0.14 Kpa
Kpa
Kpa
Kpa
Kpa

Kpa FLOOR,WOOD JOIST (no plaster)


Joist sizes Joist-Spacing
Kpa (mm) 300mm 400mm 500mm
50x150 0.3 0.25 0.25
Kpa 50x200 0.3 0.3 0.25
50x250 0.35 0.3 0.3
Kpa 50x300 0.4 0.35 0.3

Kpa
Kpa
Kpa
Kpa
Kpa
Kpa
Kpa
Kpa
Kpa
Kpa
Kpa
Kpa

Hollow Concrete Masonry units


Note: add for each face plastered 0.24 Kpa
Kpa Width Thickness(mm)
Grout spacing
100 150 200
Kpa Class C 16.5 KN/cu.m. Density of Unit
Kpa No Grout 1.05 1.15 1.48
Kpa 800 1.53 2.01
600 1.63 2.2
Kpa 400 1.92 2.54
Kpa FULL 2.63 3.59 stl load
Kpa Class B 19.6 KN/cu.m. Density of Unit conc. Load
Kpa No Grout 1.24 1.34 1.72 wal/partitions
800 1.72 2.25 LL/OCCUPANCY USE
600 1.87 2.44
400 2.11 2.82
FULL 2.82 3.88
Class A 21.2 KN/cu.m. Density of Unit
No Grout 1.39 1.44 1.87
800 1.82 2.39
600 1.96 2.59
400 2.2 2.92
FULL 2.97 3.97
0.096

1.90272

accomodation load for footing

984.24
28.12611

2.4
LOAD CRITERIA

DEAD LOAD
Reinforced Conc= 24KN/cu.m.
Super Imposed DL:
As internal masonry walls 4" CHB= 2.5KPa
External masonry wall 6" CHB= 3.6KPa
Exterior wall 6" CHB w/ window= 3.6KPa
Floor fin.,toppings,plaster & screed= 1.2KPa
Ceiling & utilities= 0.60KPa

LIVE LOAD
Offices= 2.4KPa
Stairs & hallways= 4.80KPa
Flat Conc. Roofs= 3.00KPa
Restroom= 2.4KPa
movable Partion= 1.00KPa

ACI LIMITATION
Mini. Thk of slab unless deflection are computed

Member End Condition fy=40ksi fy=60ksi

solid 1-way Simple Support S/25 S/20

Slabs 1-end Continous S/30 S/34


Both Ends S/35 S/18

Materials :

Concrete : Normal weight concrete with 28-days compressive cube streght ( Cylindrical compressive strenght)
as follows;

FOUNDATION 30 mpa ( Fc' -= 24mpa)


SUSPENDED SLABS and BEAMS 30 mpa ( Fc' -= 24mpa)
COLUMNS 30 mpa ( Fc' -= 24mpa)
SHEAR WALLS 30 mpa ( Fc' -= 24mpa)

Concrete Reinforcement : ASTM A615M Grade 60 ( minimum yield stress 420 Mpa ).

Ec = 23025.3 Mpa
Es = 21000 Mpa

LOAD COMBINATION
All designs for shear walls and link beams were compute using ACI - 318 / IBC load Combinations

1.4DL
1.7LL
1.4(D+SDL)+1.7LL
IBCx+IBCz+(1.4DL+1.7LL+SDL)

Dl DEAD LOAD
LL LIVE LOAD
SDL SUPERIMPOSED DEAD LOAD
WL WIND LOAD

FOUNDATION:
Bearing Capacity as Soil Report
Foundation Level as Soil Report