Chapter 01

This document contains questions and answers about calculating errors in electrical measurements. It discusses computing the absolute and percentage errors when a measured current of 1.46 A differs from the actual current of 1.5 A. It also covers finding the relative and percentage accuracy of a resistor measurement of 1.93 kΩ that has an actual value of 2 kΩ. Finally, it determines which of six voltage measurements ranging from 19.85 to 20.2 V is most precise based on its difference from the average of 20.0167 V.

Uploaded by

tmya06
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
516 views15 pages

Chapter 01

This document contains questions and answers about calculating errors in electrical measurements. It discusses computing the absolute and percentage errors when a measured current of 1.46 A differs from the actual current of 1.5 A. It also covers finding the relative and percentage accuracy of a resistor measurement of 1.93 kΩ that has an actual value of 2 kΩ. Finally, it determines which of six voltage measurements ranging from 19.85 to 20.2 V is most precise based on its difference from the average of 20.0167 V.

Uploaded by

tmya06
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 15

Q1: The current through a resistor is 1.

5 A, but measurement
yields a value of 1.46 A. Compute the absolute error and the
percentage of error of the measurement.
Q1: The current through a resistor is 1.5 A, but measurement
yields a value of 1.46 A. Compute the absolute error and the
percentage of error of the measurement.

A1:
Yn = 1.5A, Xn = 1.46A
Q1: The current through a resistor is 1.5 A, but measurement
yields a value of 1.46 A. Compute the absolute error and the
percentage of error of the measurement.

A1:
Yn = 1.5A, Xn = 1.46A

The absolute error:

e = Yn − Xn = 1.5 − 1.46 = 0.04 A


Q1: The current through a resistor is 1.5 A, but measurement
yields a value of 1.46 A. Compute the absolute error and the
percentage of error of the measurement.

A1:
Yn = 1.5A, Xn = 1.46A

The absolute error:

e = Yn − Xn = 1.5 − 1.46 = 0.04 A

The percent of error of the measurement:


e 0.04
Percent error = × 100% = × 100% = 2.7%
Yn 1.5
Q2: The value of a resistor is 2kΩ; however, measurement yields a
value of 1.93kΩ. Compute:

(a) The relative accuracy of the measurement.

(b) The percent accuracy of the measurement.


Q2: The value of a resistor is 2kΩ; however, measurement yields a
value of 1.93kΩ. Compute:

(a) The relative accuracy of the measurement.

(b) The percent accuracy of the measurement.

A2: Yn = 2kΩ, Xn = 1.93kΩ


Q2: The value of a resistor is 2kΩ; however, measurement yields a
value of 1.93kΩ. Compute:

(a) The relative accuracy of the measurement.

(b) The percent accuracy of the measurement.

A2: Yn = 2kΩ, Xn = 1.93kΩ



Yn −Xn
(a) A = 1 − Yn = 1 − 2k−1.93k

= 1 − 0.035 = 0.96.
2k
Q2: The value of a resistor is 2kΩ; however, measurement yields a
value of 1.93kΩ. Compute:

(a) The relative accuracy of the measurement.

(b) The percent accuracy of the measurement.

A2: Yn = 2kΩ, Xn = 1.93kΩ



Yn −Xn
(a) A = 1 − Yn = 1 − 2k−1.93k

= 1 − 0.035 = 0.96.
2k

(b) a = A × 100 = 96%.


Q3: If the average of a set voltage readings is 30.15V, compute
the precision of one of the readings that was equal to 29.9V.
Q3: If the average of a set voltage readings is 30.15V, compute
the precision of one of the readings that was equal to 29.9V.

A3: Xn = 29.9V, X n = 30.15V.


Q3: If the average of a set voltage readings is 30.15V, compute
the precision of one of the readings that was equal to 29.9V.

A3: Xn = 29.9V, X n = 30.15V.


Xn − X n
Precision = 1 −

Xn

29.9 − 30.15
=1− = 1 − 0.0083 = 0.992.
30.15
Q4: The output voltage of an amplifier was measured by six
different students using the same oscilloscope with the following
results.
(a) 20.20V (b) 19.90V (c) 20.05V
(d) 20.10V (e) 19.85V (f) 20.00V
Which is the most precise measurement?
Q4: The output voltage of an amplifier was measured by six
different students using the same oscilloscope with the following
results.
(a) 20.20V (b) 19.90V (c) 20.05V
(d) 20.10V (e) 19.85V (f) 20.00V
Which is the most precise measurement?

A4:
Q4: The output voltage of an amplifier was measured by six
different students using the same oscilloscope with the following
results.
(a) 20.20V (b) 19.90V (c) 20.05V
(d) 20.10V (e) 19.85V (f) 20.00V
Which is the most precise measurement?

A4:
20.20 + 19.90 + 20.05 + 20.10 + 19.85 + 20.00
Xn =
6
120.1
= = 20.0167.
6
Q4: The output voltage of an amplifier was measured by six
different students using the same oscilloscope with the following
results.
(a) 20.20V (b) 19.90V (c) 20.05V
(d) 20.10V (e) 19.85V (f) 20.00V
Which is the most precise measurement?

A4:
20.20 + 19.90 + 20.05 + 20.10 + 19.85 + 20.00
Xn =
6
120.1
= = 20.0167.
6
(a) Precision = 0.9908 (b) Precision = 0.9942
(c) Precision = 0.9983 (d) Precision = 0.9958
(e) Precision = 0.9917 (f) Precision = 0.9992

The most precise measurement is 20.00V.