MC 111 Cs
MC 111 Cs
MC100CM
MC110CS
Fast Ethernet Media Converter
MC111CS
MC112CS
WDM Fast Ethernet Media Converter
http://www.tp-link.com
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or
more of the following measures:
CE Mark Warning
Note:
Make sure that the package contains the above items. If any of the
listed items are damaged or missing, please contact your distributor.
1
More user manuals on ManualsBase.com
Chapter 1 Introduction
Thank you for choosing the MC100CM/MC110CS Fast Ethernet
Media Converters or the MC111CS/MC112CS WDM Fast Ethernet
Media Converters!
Note:
This media converter can also be powered by 5VDC adapter.
2
More user manuals on ManualsBase.com
1.2 Conventions
The Converter mentioned in this guide stands for Fast Ethernet
Media Converters or the WDM Fast Ethernet Media Converters
without any explanation.
The TP port mentioned in this User Manual stands for the TX port
without any explanations.
Note:
The four converters are sharing this User Guide. The differences
between them please refer to the table of the section 1.4.
1.3 Features
¾ Complies with 802.3u 10/100Base-TX, 100Base-FX standards.
¾ Provides one SC fiber connector and one RJ-45 connector.
¾ Supports auto negotiation of duplex mode on TP port.
¾ Supports auto negotiation of 10/100Mbps and auto MID/MID-X for
TP port.
¾ Supports Link Fault Pass Through function and Far End Fault
function.
¾ Extends fiber distance up to 2km for multi-mode fiber and
20-60km for single-mode fiber.
¾ Easy-to-view LED indicators provide status to monitor network
activity easily.
¾ External power supply.
3
More user manuals on ManualsBase.com
¾ Connectors: RJ-45, SC.
¾ Network Cables: Cat.5 Twisted-Pair (below abbreviated as
TP), 1300nm 62.5/125, 50/125um Single-mode/Multi-mode
fiber.
Transmission Transmission Output Center
Model NO. Interface
Distance Media Wavelength
Multi-mode
MC100CM RJ45--SC 2km 1310nm
Fiber, TP
Single-mode
MC110CS-20 RJ45--SC 20km 1310nm
Fiber, TP
Single-mode
MC110CS-40 RJ45--SC 40km 1310nm
Fiber, TP
Single-mode
MC110CS-60 RJ45--SC 60km 1310nm
Fiber, TP
Single-mode 1550nmTX
MC111CS-20 RJ45--SC 20km
Fiber, TP 1310nmRX
Single-mode 1550nmTX
MC111CS-40 RJ45--SC 40km
Fiber, TP 1310nmRX
Single-mode 1550nmTX
MC111CS-60 RJ45--SC 60km
Fiber, TP 1310nmRX
Single-mode 1310nmTX
MC112CS-20 RJ45--SC 20km
Fiber, TP 1550nmRX
Single-mode 1310nmTX
MC112CS-40 RJ45--SC 40km
Fiber, TP 1550nmRX
Single-mode 1310nmTX
MC112CS-60 RJ45--SC 60km
Fiber, TP 1550nmRX
4
More user manuals on ManualsBase.com
Name Status Indication
On Power on
PWR
Off Power off
On The Link Fault Pass Through function enable.
LFP
Off The Link Fault Pass Through function disable.
On There’s a valid link.
5
More user manuals on ManualsBase.com
1.5.2 Switch
6
More user manuals on ManualsBase.com
The Mode Of The Device Switch
TP_AUTO, TP_100M, TP_FDX,
TP:AUTO; LFP ON
LFP_ON
TP_AUTO, TP_100M, TP_FDX,
TP:AUTO; LFP OFF
LFP_OFF
TP_DIS, TP_100M, TP_FDX,
TP:FORCE,100M,FULL; LFP ON
LFP_ON
TP_DIS, TP_100M, TP_FDX,
TP:FORCE,100M,FULL; LFP OFF
LFP_OFF
(TP_DIS or TP_AUTO), TP_100M,
TP:FORCE,100M, HALF; LFP ON
TP_HDX, LFP_ON
(TP_DIS or TP_AUTO), TP_100M,
TP:FORCE,100M, HALF; LFP OFF
TP_HDX, LFP_OFF
TP_DIS, TP_10M, TP_FDX,
TP:FORCE,10M,FULL; LFP ON
LFP_ON
TP_DIS, TP_10M, TP_FDX,
TP:FORCE,10M,FULL; LFP OFF
LFP_OFF
(TP_DIS or TP_AUTO), TP_10M,
TP:FORCE,10M, HALF; LFP ON
TP_HDX, LFP_ON
(TP_DIS or TP_AUTO), TP_10M,
TP:FORCE,10M, HALF; LFP OFF
TP_HDX, LFP_OFF
Note:
1) We suggest leaving the switches on TP_AUTO, TP_100M,
TP_FDX, and LFP_ON, because this configuration is suitable for
lots of situations.
2) You have to reset the converter after configuring the switches.
7
More user manuals on ManualsBase.com
With the Link Fault Pass Through function enabled (optional with
switch LFP), TP port and FX port of the same converter will inform
each other the fault link status so that when one side of the link fails,
the other side will force the link to shut down as soon as noticed. The
procedure will be illustrated as shown below.
If link fail happens on TP port (A), the FX port (A) sends non-idle
pattern to notice the FX port (B). The FX port (B) then forces its TP
port (B) to link failed after receiving the non-idle pattern. Link status
LED will also be off for both Converters and Devices as shown below.
Link LED
Device A Off
Device B Off
FX_LFP FX_Link/Act TP_Link/Act
Converter A On Off Off
Converter B On Off Off
8
More user manuals on ManualsBase.com
Chapter 2 Installation Guide
2.1 Fast Ethernet Media Converter
1. The SC fiber connector of MC100CM transmits/receives data by
1310nm short wave laser on multi-mode fiber.
2. The SC fiber connector of MC110CS transmits/receives data by
1310nm short wave laser on single-mode fiber.
Note:
You have to use either two MC100CM connectors or two MC110CS
connectors to cooperate.
9
More user manuals on ManualsBase.com
Transmits and receives data on the same fiber
Note:
You have to use MC111CS and MC112CS at the same time to
cooperate.
10
More user manuals on ManualsBase.com
Chapter 3 Configuration
In order to achieve the aim of effectively expanding a Fast Ethernet
network, you can use the converter like the following examples:
Note:
You should use two MC100CM Media Converters or two MC110CS
Media Converters, or one MC111CS and one MC112CS to expand
your network. Error will occur when you use other ways.
11
More user manuals on ManualsBase.com
3.1 Installation Procedure
Use a fiber cable to connect two converters, or connect a converter
with a 100Base-FX Device.
• Make sure that the length of the Cat.5 twisted pair cable
between the 10/100Base-TX device and the converter is less
than 100 meters.
• Connect one end of the Cat.5 twisted pair cable to the RJ45
jack on the converter and the other end of the cable to the
RJ45 jack on the 10/100Base-TX device.
12
More user manuals on ManualsBase.com
Appendix: Specifications
Storage: 5% ~ 90% RH
Non-condensing
Humidity
Working: 10% ~ 90% RH
Non-condensing
13
More user manuals on ManualsBase.com
7106503725
14