0% found this document useful (0 votes)
41 views14 pages

Design of Isolated Footing

The document summarizes the design of 6 isolated footings (MKD F1 through MKD F6). For each footing, it provides the size, design load, reinforcement details, and checks for bending capacity, one-way shear capacity, and two-way shear capacity. All footings were found to meet the design requirements for the given loads and soil conditions.

Uploaded by

IS CODE
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
41 views14 pages

Design of Isolated Footing

The document summarizes the design of 6 isolated footings (MKD F1 through MKD F6). For each footing, it provides the size, design load, reinforcement details, and checks for bending capacity, one-way shear capacity, and two-way shear capacity. All footings were found to meet the design requirements for the given loads and soil conditions.

Uploaded by

IS CODE
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 14

DESIGN OF ISOLATED FOOTING MKD F1

SIZE = 300 X 300

P= 184.1 KN DESIGN LOAD = 203 KN

2
L= 1.5 M B= 1.5 M fck = 25 N / MM
2
Fy = 500 N / MM
BASE PRESSURE = 90.00 KN/SQM

DESIGN FOR BENDING:

CANTILEVER= 0.6 M BM = 16.20 KNM/M


MU = 24.30 KNM/M

D1 = 150 MM EFFECTIVE DEPTH= 215 MM


D2 = 125 MM

MU/BD2 = 0.526 N / SQMM Pt = 0.205 Ast = 440.75 SQMM

PROVIDE 12 TOR @ 225 MM C / C ( Ast = 565 SQMM PER METRE )

CHECK FOR ONE WAY SHEAR:

SF = 34.65 KN Vu= 51.98 KN

EFFECTIVE DEPTH AVAILABLE = 170 MM Tv = 0.305 N / SQMM

Pt = 0.26 Tc = 0.36 N / SQMM

CHECK FOR TWO WAY SHEAR:

LENGTH OF SHEAR SECTION= 2060 MM

EFFECTIVE DEPTH AVAILABLE = 192.60 MM

Tv = 0.77 N / SQMM

Ks = 1.00 B C= 1

Tc = 1.250 N / SQMM

Ks Tc = 1.250 N / SQMM

Ks Tc > Tv HENCE O.K.


DESIGN OF ISOLATED FOOTING MKD F2

SIZE = 300 X 300

P= 250.56 KN DESIGN LOAD = 276 KN

2
L= 1.75 M B= 1.75 M fck = 25 N / MM
2
Fy = 500 N / MM
BASE PRESSURE = 90.00 KN/SQM

DESIGN FOR BENDING:

CANTILEVER= 0.725 M BM = 23.65 KNM/M


MU = 35.48 KNM/M

D1 = 150 MM EFFECTIVE DEPTH= 240 MM


D2 = 150 MM

MU/BD2 = 0.616 N / SQMM Pt = 0.205 Ast = 492 SQMM

PROVIDE 12 TOR @ 200 MM C / C ( Ast = 678 SQMM PER METRE )

CHECK FOR ONE WAY SHEAR:

SF = 43.65 KN Vu= 65.47 KN

EFFECTIVE DEPTH AVAILABLE = 190 MM Tv = 0.344 N / SQMM

Pt = 0.26 Tc = 0.36 N / SQMM

CHECK FOR TWO WAY SHEAR:

LENGTH OF SHEAR SECTION= 2160 MM

EFFECTIVE DEPTH AVAILABLE = 215.17 MM

Tv = 0.89 N / SQMM

Ks = 1.00 B C= 1

Tc = 1.250 N / SQMM

Ks Tc = 1.250 N / SQMM

Ks Tc > Tv HENCE O.K.


DESIGN OF ISOLATED FOOTING MKD F3

SIZE = 300 X 300

P= 327.27 KN DESIGN LOAD = 360 KN

2
L= 2 M B= 2 M fck = 25 N / MM
2
Fy = 500 N / MM
BASE PRESSURE = 90.00 KN/SQM

DESIGN FOR BENDING:

CANTILEVER= 0.85 M BM = 32.51 KNM/M


MU = 48.77 KNM/M

D1 = 150 MM EFFECTIVE DEPTH= 290 MM


D2 = 200 MM

MU/BD2 = 0.580 N / SQMM Pt = 0.205 Ast = 594.5 SQMM

PROVIDE 12 TOR @ 175 MM C / C ( Ast = 791 SQMM PER METRE )

CHECK FOR ONE WAY SHEAR:

SF = 50.40 KN Vu= 75.60 KN

EFFECTIVE DEPTH AVAILABLE = 222 MM Tv = 0.341 N / SQMM

Pt = 0.27 Tc = 0.36 N / SQMM

CHECK FOR TWO WAY SHEAR:

LENGTH OF SHEAR SECTION= 2360 MM

EFFECTIVE DEPTH AVAILABLE = 255.88 MM

Tv = 0.89 N / SQMM

Ks = 1.00 B C= 1

Tc = 1.250 N / SQMM

Ks Tc = 1.250 N / SQMM

Ks Tc > Tv HENCE O.K.


DESIGN OF ISOLATED FOOTING MKD F4

SIZE = 300 X 300

P= 432.82 KN DESIGN LOAD = 476 KN

2
L= 2.3 M B= 2.3 M fck = 25 N / MM
2
Fy = 500 N / MM
BASE PRESSURE = 90.00 KN/SQM

DESIGN FOR BENDING:

CANTILEVER= 1M BM = 45.00 KNM/M


MU = 67.50 KNM/M

D1 = 150 MM EFFECTIVE DEPTH= 340 MM


D2 = 250 MM

MU/BD2 = 0.584 N / SQMM Pt = 0.205 Ast = 697 SQMM

PROVIDE 12 TOR @ 150 MM C / C ( Ast = 904 SQMM PER METRE )

CHECK FOR ONE WAY SHEAR:

SF = 59.40 KN Vu= 89.10 KN

EFFECTIVE DEPTH AVAILABLE = 255 MM Tv = 0.349 N / SQMM

Pt = 0.27 Tc = 0.36 N / SQMM

CHECK FOR TWO WAY SHEAR:

LENGTH OF SHEAR SECTION= 2560 MM

EFFECTIVE DEPTH AVAILABLE = 297.50 MM

Tv = 0.94 N / SQMM

Ks = 1.00 B C= 1

Tc = 1.250 N / SQMM

Ks Tc = 1.250 N / SQMM

Ks Tc > Tv HENCE O.K.


DESIGN OF ISOLATED FOOTING MKD F5

SIZE = 300 X 300

P= 511.36 KN DESIGN LOAD = 562 KN

2
L= 2.5 M B= 2.5 M fck = 25 N / MM
2
Fy = 500 N / MM
BASE PRESSURE = 90.00 KN/SQM

DESIGN FOR BENDING:

CANTILEVER= 1.1 M BM = 54.45 KNM/M


MU = 81.67 KNM/M

D1 = 150 MM EFFECTIVE DEPTH= 390 MM


D2 = 300 MM

MU/BD2 = 0.537 N / SQMM Pt = 0.205 Ast = 799.5 SQMM

PROVIDE 12 TOR @ 125 MM C / C ( Ast = 1017 SQMM PER METRE )

CHECK FOR ONE WAY SHEAR:

SF = 63.90 KN Vu= 95.85 KN

EFFECTIVE DEPTH AVAILABLE = 284 MM Tv = 0.338 N / SQMM

Pt = 0.28 Tc = 0.375 N / SQMM

CHECK FOR TWO WAY SHEAR:

LENGTH OF SHEAR SECTION= 2760 MM

EFFECTIVE DEPTH AVAILABLE = 336.82 MM

Tv = 0.91 N / SQMM

Ks = 1.00 B C= 1

Tc = 1.250 N / SQMM

Ks Tc = 1.250 N / SQMM

Ks Tc > Tv HENCE O.K.


DESIGN OF ISOLATED FOOTING MKD F6

SIZE = 300 X 300

P= 596.45 KN DESIGN LOAD = 656 KN

2
L= 2.7 M B= 2.7 M fck = 25 N / MM
2
Fy = 500 N / MM
BASE PRESSURE = 90.00 KN/SQM

DESIGN FOR BENDING:

CANTILEVER= 1.2 M BM = 64.80 KNM/M


MU = 97.20 KNM/M

D1 = 150 MM EFFECTIVE DEPTH= 415 MM


D2 = 325 MM

MU/BD2 = 0.564 N / SQMM Pt = 0.205 Ast = 850.75 SQMM

PROVIDE 12 TOR @ 110 MM C / C ( Ast = 1130 SQMM PER METRE )

CHECK FOR ONE WAY SHEAR:

SF = 70.65 KN Vu= 105.97 KN

EFFECTIVE DEPTH AVAILABLE = 303 MM Tv = 0.350 N / SQMM

Pt = 0.28 Tc = 0.375 N / SQMM

CHECK FOR TWO WAY SHEAR:

LENGTH OF SHEAR SECTION= 2860 MM

EFFECTIVE DEPTH AVAILABLE = 358.80 MM

Tv = 0.96 N / SQMM

Ks = 1.00 B C= 1

Tc = 1.250 N / SQMM

Ks Tc = 1.250 N / SQMM

Ks Tc > Tv HENCE O.K.


DESIGN OF ISOLATED FOOTING MKD F7

SIZE = 300 X 300

P= 688.1 KN DESIGN LOAD = 757 KN

2
L= 2.9 M B= 2.9 M fck = 25 N / MM
2
Fy = 500 N / MM
BASE PRESSURE = 90.00 KN/SQM

DESIGN FOR BENDING:

CANTILEVER= 1.3 M BM = 76.05 KNM/M


MU = 114.08 KNM/M

D1 = 150 MM EFFECTIVE DEPTH= 440 MM


D2 = 350 MM

MU/BD2 = 0.589 N / SQMM Pt = 0.205 Ast = 902 SQMM

PROVIDE 12 TOR @ 110 MM C / C ( Ast = 1130 SQMM PER METRE )

CHECK FOR ONE WAY SHEAR:

SF = 77.40 KN Vu= 116.10 KN

EFFECTIVE DEPTH AVAILABLE = 322 MM Tv = 0.361 N / SQMM

Pt = 0.28 Tc = 0.375 N / SQMM

CHECK FOR TWO WAY SHEAR:

LENGTH OF SHEAR SECTION= 2960 MM

EFFECTIVE DEPTH AVAILABLE = 380.77 MM

Tv = 1.01 N / SQMM

Ks = 1.00 B C= 1

Tc = 1.250 N / SQMM

Ks Tc = 1.250 N / SQMM

Ks Tc > Tv HENCE O.K.


DESIGN OF ISOLATED FOOTING MKD F8

SIZE = 300 X 300

P= 786.27 KN DESIGN LOAD = 865 KN

2
L= 3.1 M B= 3.1 M fck = 25 N / MM
2
Fy = 500 N / MM
BASE PRESSURE = 90.00 KN/SQM

DESIGN FOR BENDING:

CANTILEVER= 1.4 M BM = 88.20 KNM/M


MU = 132.30 KNM/M

D1 = 200 MM EFFECTIVE DEPTH= 490 MM


D2 = 350 MM

MU/BD2 = 0.551 N / SQMM Pt = 0.205 Ast = 1004.5 SQMM

PROVIDE 12 TOR @ 100 MM C / C ( Ast = 1243 SQMM PER METRE )

CHECK FOR ONE WAY SHEAR:

SF = 81.90 KN Vu= 122.85 KN

EFFECTIVE DEPTH AVAILABLE = 368 MM Tv = 0.334 N / SQMM

Pt = 0.27 Tc = 0.36 N / SQMM

CHECK FOR TWO WAY SHEAR:

LENGTH OF SHEAR SECTION= 3160 MM

EFFECTIVE DEPTH AVAILABLE = 428.75 MM

Tv = 0.96 N / SQMM

Ks = 1.00 B C= 1

Tc = 1.250 N / SQMM

Ks Tc = 1.250 N / SQMM

Ks Tc > Tv HENCE O.K.


DESIGN OF ISOLATED FOOTING MKD F9

SIZE = 300 X 300

P= 891 KN DESIGN LOAD = 980 KN

2
L= 3.3 M B= 3.3 M fck = 25 N / MM
2
Fy = 500 N / MM
BASE PRESSURE = 90.00 KN/SQM

DESIGN FOR BENDING:

CANTILEVER= 1.5 M BM = 101.25 KNM/M


MU = 151.88 KNM/M

D1 = 200 MM EFFECTIVE DEPTH= 515 MM


D2 = 375 MM

MU/BD2 = 0.573 N / SQMM Pt = 0.205 Ast = 1055.75 SQMM

PROVIDE 12 TOR @ 95 MM C / C ( Ast = 1243 SQMM PER METRE )

CHECK FOR ONE WAY SHEAR:

SF = 88.65 KN Vu= 132.98 KN

EFFECTIVE DEPTH AVAILABLE = 386 MM Tv = 0.344 N / SQMM

Pt = 0.27 Tc = 0.36 N / SQMM

CHECK FOR TWO WAY SHEAR:

LENGTH OF SHEAR SECTION= 3260 MM

EFFECTIVE DEPTH AVAILABLE = 450.63 MM

Tv = 1.00 N / SQMM

Ks = 1.00 B C= 1

Tc = 1.250 N / SQMM

Ks Tc = 1.250 N / SQMM

Ks Tc > Tv HENCE O.K.


DESIGN OF ISOLATED FOOTING MKD F10

SIZE = 300 X 300

P= 1090.03 KN DESIGN LOAD = 1199 KN

2
L= 3.65 M B= 3.65 M fck = 25 N / MM
2
Fy = 500 N / MM
BASE PRESSURE = 90.00 KN/SQM

DESIGN FOR BENDING:

CANTILEVER= 1.675 M BM = 126.25 KNM/M


MU = 189.38 KNM/M

D1 = 200 MM EFFECTIVE DEPTH= 590 MM


D2 = 450 MM

MU/BD2 = 0.544 N / SQMM Pt = 0.205 Ast = 1209.5 SQMM

PROVIDE 16 TOR @ 150 MM C / C ( Ast = 1407 SQMM PER METRE )

CHECK FOR ONE WAY SHEAR:

SF = 97.65 KN Vu= 146.48 KN

EFFECTIVE DEPTH AVAILABLE = 431 MM Tv = 0.339 N / SQMM

Pt = 0.28 Tc = 0.375 N / SQMM

CHECK FOR TWO WAY SHEAR:

LENGTH OF SHEAR SECTION= 3560 MM

EFFECTIVE DEPTH AVAILABLE = 510.75 MM

Tv = 0.99 N / SQMM

Ks = 1.00 B C= 1

Tc = 1.250 N / SQMM

Ks Tc = 1.250 N / SQMM

Ks Tc > Tv HENCE O.K.


DESIGN OF ISOLATED FOOTING MKD F11

SIZE = 300 X 300

P= 1181.46 KN DESIGN LOAD = 1300 KN

2
L= 3.8 M B= 3.8 M fck = 25 N / MM
2
Fy = 500 N / MM
BASE PRESSURE = 90.00 KN/SQM

DESIGN FOR BENDING:

CANTILEVER= 1.75 M BM = 137.81 KNM/M


MU = 206.72 KNM/M

D1 = 250 MM EFFECTIVE DEPTH= 590 MM


D2 = 400 MM

MU/BD2 = 0.594 N / SQMM Pt = 0.205 Ast = 1209.5 SQMM

PROVIDE 16 TOR @ 150 MM C / C ( Ast = 1407 SQMM PER METRE )

CHECK FOR ONE WAY SHEAR:

SF = 104.40 KN Vu= 156.60 KN

EFFECTIVE DEPTH AVAILABLE = 455 MM Tv = 0.344 N / SQMM

Pt = 0.27 Tc = 0.36 N / SQMM

CHECK FOR TWO WAY SHEAR:

LENGTH OF SHEAR SECTION= 3560 MM

EFFECTIVE DEPTH AVAILABLE = 522.57 MM

Tv = 1.05 N / SQMM

Ks = 1.00 B C= 1

Tc = 1.250 N / SQMM

Ks Tc = 1.250 N / SQMM

Ks Tc > Tv HENCE O.K.


DESIGN OF ISOLATED FOOTING MKD F12

SIZE = 300 X 300

P= 1276.57 KN DESIGN LOAD = 1404 KN

2
L= 3.95 M B= 3.95 M fck = 25 N / MM
2
Fy = 500 N / MM
BASE PRESSURE = 90.00 KN/SQM

DESIGN FOR BENDING:

CANTILEVER= 1.825 M BM = 149.88 KNM/M


MU = 224.82 KNM/M

D1 = 250 MM EFFECTIVE DEPTH= 615 MM


D2 = 425 MM

MU/BD2 = 0.594 N / SQMM Pt = 0.205 Ast = 1260.75 SQMM

PROVIDE 16 TOR @ 150 MM C / C ( Ast = 1407 SQMM PER METRE )

CHECK FOR ONE WAY SHEAR:

SF = 108.90 KN Vu= 163.35 KN

EFFECTIVE DEPTH AVAILABLE = 472 MM Tv = 0.346 N / SQMM

Pt = 0.27 Tc = 0.36 N / SQMM

CHECK FOR TWO WAY SHEAR:

LENGTH OF SHEAR SECTION= 3660 MM

EFFECTIVE DEPTH AVAILABLE = 543.39 MM

Tv = 1.06 N / SQMM

Ks = 1.00 B C= 1

Tc = 1.250 N / SQMM

Ks Tc = 1.250 N / SQMM

Ks Tc > Tv HENCE O.K.


DESIGN OF ISOLATED FOOTING MKD F13

SIZE = 300 X 300

P= 1375.36 KN DESIGN LOAD = 1513 KN

2
L= 4.1 M B= 4.1 M fck = 25 N / MM
2
Fy = 500 N / MM
BASE PRESSURE = 90.00 KN/SQM

DESIGN FOR BENDING:

CANTILEVER= 1.9 M BM = 162.45 KNM/M


MU = 243.67 KNM/M

D1 = 250 MM EFFECTIVE DEPTH= 640 MM


D2 = 450 MM

MU/BD2 = 0.595 N / SQMM Pt = 0.205 Ast = 1312 SQMM

PROVIDE 16 TOR @ 135 MM C / C ( Ast = 1608 SQMM PER METRE )

CHECK FOR ONE WAY SHEAR:

SF = 113.40 KN Vu= 170.10 KN

EFFECTIVE DEPTH AVAILABLE = 488 MM Tv = 0.348 N / SQMM

Pt = 0.27 Tc = 0.36 N / SQMM

CHECK FOR TWO WAY SHEAR:

LENGTH OF SHEAR SECTION= 3760 MM

EFFECTIVE DEPTH AVAILABLE = 564.21 MM

Tv = 1.07 N / SQMM

Ks = 1.00 B C= 1

Tc = 1.250 N / SQMM

Ks Tc = 1.250 N / SQMM

Ks Tc > Tv HENCE O.K.


DESIGN OF ISOLATED FOOTING MKD F14

SIZE = 450 X 450

P= 1512.82 KN DESIGN LOAD = 1664 KN

2
L= 4.3 M B= 4.3 M fck = 25 N / MM
2
Fy = 500 N / MM
BASE PRESSURE = 90.00 KN/SQM

DESIGN FOR BENDING:

CANTILEVER= 1.925 M BM = 166.75 KNM/M


MU = 250.13 KNM/M

D1 = 250 MM EFFECTIVE DEPTH= 665 MM


D2 = 475 MM

MU/BD2 = 0.566 N / SQMM Pt = 0.205 Ast = 1363.25 SQMM

PROVIDE 16 TOR @ 125 MM C / C ( Ast = 1809 SQMM PER METRE )

CHECK FOR ONE WAY SHEAR:

SF = 113.40 KN Vu= 170.10 KN

EFFECTIVE DEPTH AVAILABLE = 501 MM Tv = 0.340 N / SQMM

Pt = 0.27 Tc = 0.36 N / SQMM

CHECK FOR TWO WAY SHEAR:

LENGTH OF SHEAR SECTION= 4460 MM

EFFECTIVE DEPTH AVAILABLE = 582.95 MM

Tv = 0.96 N / SQMM

Ks = 1.00 B C= 1

Tc = 1.250 N / SQMM

Ks Tc = 1.250 N / SQMM

Ks Tc > Tv HENCE O.K.