0% found this document useful (0 votes)
122 views

Heat Input Sheet

This document contains a heat input calculation for a welding process with multiple layers including a root pass, hot pass, fill pass, and cap pass. It lists the current, voltage, welding time, weld length, travel speed, and resulting heat input for each layer. Decimal values should use a period instead of comma. Signatures from FB QC, Allseas, and Noble are required at the bottom to verify the calculation.

Uploaded by

ricardo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
122 views

Heat Input Sheet

This document contains a heat input calculation for a welding process with multiple layers including a root pass, hot pass, fill pass, and cap pass. It lists the current, voltage, welding time, weld length, travel speed, and resulting heat input for each layer. Decimal values should use a period instead of comma. Signatures from FB QC, Allseas, and Noble are required at the bottom to verify the calculation.

Uploaded by

ricardo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 1

Heat Input Calculation

Alterar apenas os valores do Current, Voltage, Welding Time e Weld Length

Para valores decimais usar ponto e nao virgula

Type of Interpass / Welding Weld Travel Heat


Layer Welding Current Voltage current / pre-heat time length speed input
process [A] [V] polarity temp [°C] [sec] [mm] [cm/min] [kJ/mm]

root 115.00 16.50 206 250 7.28 1.56


Hot pass 205.00 22.70 76 250 19.74 1.41
Fill 203.00 23.40 64 250 23.44 1.22
Cap 207.00 22.50 55 250 27.27 1.02

Signature FB QC: Signature Allseas: Signature Noble: