CET Power - AGIL Tri-Tri Datasheet v2.5

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

www.cet-power.

com AGIL TRI-TRI

20-640
kVA

TELECOM DATACOM MASS TRANSIT OIL & GAS POWER UTILITIES

20 kVA = 20 kW
module

MODULAR UPS
Module POWER 20 kVA - 20 kW
INPUT 3x400 Vac + N
OUTPUT 3x400 Vac + N

DESCRIPTION
AGIL is a compact and scalable modular UPS providing a
pure sine wave AC supply.
The “Twin Sine Innovation” (TSI) technology ensures
independent “hot pluggable and hot swap” modules that
include virtually all functions of a conventional UPS (AC/
DC, DC/AC, battery charger, Static Switch), eliminating all
potential single points of failure.
Up to 32 modules can be installed in parallel to bring the full
output power potential to 640 kVA.
MAIN FEATURES
APPLICATIONS Selectivity
All traditional data centers applications that require flexibility Versatile charging
in their power needs. Battery sustainability
But also a large variety of applications where a multidirectional Harshest AC input conditions
energy converter is required. High efficiency, certified by SGS

Illustrations are non-binding and may include customized fittings.


www.cet-power.com AGIL TRI-TRI
AGIL Module AGIL 60 AGIL 160 AGIL 200 AGIL 640
GENERAL
EMC (immunity) EN 61000-4-2 / EN 61000-4-3 / EN 61000-4-4 / EN 61000-4-5 / EN 61000-4-6 / EN 61000-4-8
EMC (emission) (class) EN 55022 (A)
Safety EN 62040-1-1
EN62040-3 performance level VFI-SS-111
MTBF / Cooling 240 000 hrs / Forced
Efficiency (Typical): Enhanced power conversion / on line 96% / 96% certfiied by SGS at 45% load
True Redundant Systems – compliant 3 disconnection levels on AC out and DC in power ports / 4 disconnection levels on AC in port
Vibration GR63 office vibration 0 to 100 hz-0.1 g / transport vibration 5-100 Hz 0.5 g 100 to 500 hz-1.5 g / Drop test
Designed for installation in an IP20 or IP21 environment.
Operating conditions
When installed in a dusty or corrosive environment, appropriate measures (air filtering, …) must be taken.
Altitude above sea without de-rating 1500m / Above 1500m : 0.8% derating per 100m
Ambient / storage temperature / relative humidity -10 to 40 °C / -40 to 70 °C / 95%, non-condensing
Material (casing) Coated steel-ALU ZINC-Front plate coated black RAL9005
AC OUTPUT POWER
Nominal Output power (VA) / (W) 20 kVA / 20 kW 60 kVA / 60 kW 160 kVA / 160 kW 200 kVA / 200 kW 640 kVA / 640 kW
Short time overload capacity (@PF 0.9) 150% - 15s | 130% - 30s | 120% - 60s | 110% permanent
Admissible load power factor Full power rating from 0 inductive to 0 capacitive
Internal temperature management and switch off Yes
DC BATTERY SPECIFICATIONS
Nominal voltage (DC) 408 Vdc (204 cells VRLA) or 336 cells (NiCd)
Voltage range (DC) 336 Vdc to 490 Vdc
Nominal current (at 408 Vdc) 52 A 156 A 416 A 520 A 1664 A
Maximum input current (for 5 second) / voltage ripple 67 A / < 400 mV rm 201 A / < 400m V rms 536 A / < 400m V rms 670 A / < 400m V rms 2144 A / < 400m V rms
Input voltage boundaries User selectable with T4S interface
AC INPUT SPECIFICATIONS
Nominal voltage (AC) 3x380V / 400V / 415V + Neutral 5 wires
Voltage range (AC) 150 Vac to 275 Vac line to neutral (derating 150 to 220 Vac)
Conformity range before transfer to DC Adjustable
Power factor > 99%
Frequency range (selectable) / synchronization range 50 or 60 Hz / range 30 to 70 Hz adjustable
AC OUTPUT SPECIFICATIONS
Nominal voltage (AC*) 3x380V / 400V / 415V + Neutral 5 wires for 3 phases
Frequency / frequency accuracy 50 - 60 Hz / 0.03 %
Total harmonic distortion (resistive load) < 1.5 %
Load impact recovery time 0.4 ms
Turn on delay 20 s to 40 s depending on the number of module installed
Nominal current per phase 29 A per phase 87 A per phase 232 A per phase 290 A per phase 928 A per phase
Crest factor at nominal power 2.8 : 1
5 x In for 20 msec - Available while Mains is available at AC input port
Short circuit clear up capacity
With magnitude control and management
Short circuit current on battery, per phase 53 A 20 mS - 38 A Rms 15 Sec.
IN TRANSFER PERFORMANCE
Max. voltage interruption / total transient voltage duration (max) 0s/0s
SIGNALING & SUPERVISION
Display Synoptic LED
Alarms output / supervision Dry contacts on T4S / MODBUS, TCP-IP, SNMP
Remote on / off On rear terminal of the shelf via T4S
CABINETS
carmeldesign.be 10/2014

Dimensions (WxHxD) with external MBP ** 19" x 3U x 515 mm 600 x 2100 x 800 mm 2400 x 2100 x 800
Nbr of cabinets N/A 1 1 1+1 (for external MBP) 3+1 (for external MBP)
TSI AGIL Tri-Tri – Datasheet v2.5 Specifications can change without notice. New data will be updated on our Web site: www.cet-power.com. The present equipment is protected by several international patents, trademarks and copyrights. * Operation within lower voltage
networks leads to de-rating of
power performances.
554/572 mm ** Other cabinet heights on
demand

2100 mm
3U

24 kg
485 mm / 19"
600 mm 800 mm
Illustrations are non-binding and may include customized fittings.