A320 Fault Reset PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 156

AIR-PACK 1(2) FAULT

Aircraft configuration prior to reset:

Associated fault light illuminated on overhead pushbutton. Valve is amber on bleed page.

Circuit breakers to reset:

None

Steps to clear warning:

Select associated PACK “OFF”, then“ON” using overhead pushbuttons.

Reset duration:

5 seconds.

Results of power up test or reset:

Pass: Valve will show in-line green on bleed page.


Fail: Valve indication will be crossline amber.

Notes:

To easily determine if the valve is faulty, disconnect the flow control valve cannon plug with
bleed air present. Valve should open as per design.

Sign off:

AMM21-61-00-710-001.

Applicable deferrals:

MEL21-51-01=Flow Control Valve.


MEL21-52-01=Packs.
AIR-PACK 1(2) REGUL FAULT
Aircraft configuration prior to reset:

Select affected pack OFF, confirm on the bleed page the flow control valves are closed.

Circuit breakers to reset:

Steps to clear warning:

Open all four associated breakers for affected pack, wait 5 seconds, then close.

Reset duration:

30 seconds.

Results of power up test or reset:

Pass: Ecam fault disappears.


Fail: Ecam fault remains.

Notes:

No notes at this time.

Sign off:

AMM21-61-00-710-001.

Applicable deferrals:

MEL21-61-01=Pack Temp Control Primary Channels.


CAB PRESS SYS 1(2)FAULT

Aircraft configuration prior to reset:

No specific.

Circuit breakers to reset:

Steps to clear warning:

Open associated breakers for 2 seconds, then reset.

Reset duration:

5 seconds.

Results of power up test or reset:

Pass: Ecam fault disappears.


Fail: Ecam fault remains.

Notes:

No notes at this time.

Sign off:

AMM21-31-00-710-002.

Applicable deferrals:

MEL21-31-01=Auto System.
MEL21-31-02=Manual System.
COND-AFT CARGO HEAT FAULT
Aircraft configuration prior to reset:

No specfic.

Circuit breakers to reset:

Steps to clear warning:

Open associated breakers for 2 seconds then close. If no help perform a ground report in
CFDS.

Reset duration:

28 seconds.

Results of power up test or reset:

Pass: Ecam fault disappears.


Fail: Ecam fault remains.

Notes:

No notes at this time.

Sign off:

AMM21-28-00-710-006.

Applicable deferrals:

MEL21-43-02=Aft Cargo Heating System.


COND-RECIRC FAN FAULT
Aircraft configuration prior to reset:

No specfic.

Circuit breakers to reset:

Steps to clear warning:

Open associated breakers for 2 seconds then close.

Reset duration:

28 seconds.

Results of power up test or reset:

Pass: Ecam fault disappears.


Fail: Ecam fault remains.

Notes:

No notes at this time.

Sign off:

AMM21-21-00-710-001.

Applicable deferrals:

MEL21-21-01=Cabin Fans.
COND-TRIM AIR SYS FAULT
Aircraft configuration prior to reset:

Select affacted Pack OFF, comfirm on bleed page the flow control valve is closed. The Pack
controllers are powered and are operational

Circuit breakers to reset:

Steps to clear warning:

Open associated breakers for 2 seconds. If no help perform a CAB TEMP CTL test (300sec)
through CFDS.

Reset duration:

36 seconds.

Results of power up test or reset:

Pass: Ecam fault disappears.


Fail: Ecam fault remains.

Notes:

No notes at this time.

Sign off:

AMM21-63-00-710-004.

Applicable deferrals:

MEL21-63-02=Cockpit/Cabin Trim Air Valves.


COND-ZONE REGUL FAULT

Aircraft configuration prior to reset:

Select affacted Pack OFF, comfirm on bleed page the flow control valve is closed. The Pack
controllers are powered and are operational

Circuit breakers to reset:

Steps to clear warning:

Open associated breakers for 2 seconds. If no help perform a CAB TEMP CTL test (300sec)
through CFDS.

Reset duration:

36 seconds.

Results of power up test or reset:

Pass: Ecam fault disappears.


Fail: Ecam fault remains.

Notes:

No notes at this time.

Sign off:

AMM21-63-00-710-004.

Applicable deferrals:

MEL21-63-01=Zone Controller System.


LAV/GALLEY EXTRACT FAN FAULT
Aircraft configuration prior to reset:

No specfic.

Circuit breakers to reset:

Steps to clear warning:

Open associated breakers for 2 seconds then close.

Reset duration:

28 seconds.

Results of power up test or reset:

Pass: Ecam fault disappears.


Fail: Ecam fault remains.

Notes:

No notes at this time.

Sign off:

AMM21-61-00-710-001.

Applicable deferrals:

MEL21-23-01=Lavatory And Galley Extract Fans.


VENT-AVNCS BLOWER FAULT
Aircraft configuration prior to reset:

Blower/Exract fans in "AUTO", Ditching pushbutton "OFF".

Circuit breakers to reset:

Steps to clear warning:

Open Y17 C/B for 2 seconds, then close. If no help, open all three breakers for 2 seconds,
then close.

Reset duration:

90 seconds.

Results of power up test or reset:

Pass: Ecam fault disappears.


Fail: Ecam fault remains. Perform CFDS AVEC test.

Notes:

There is a thermal reset button on the fan motor.

Sign off:

AMM21-26-00-710-001.

Applicable deferrals:

MEL21-26-01=Blower Fan.
VENT-AVNCS EXTRACT FAULT
Aircraft configuration prior to reset:

Blower/Exract fans in AUTO, Ditching pushbutton OFF.

Circuit breakers to reset:

Steps to clear warning:

Open Y17 C/B for 2 seconds, then close. If no help, open all three breakers for 2 seconds,
then close.

Reset duration:

90 seconds.

Results of power up test or reset:

Pass: Ecam fault disappears.


Fail: Ecam fault remains. Perform CFDS AVEC test.

Notes:

There is a thermal reset button on the fan motor.

Sign off:

AMM21-26-00-710-001.

Applicable deferrals:

MEL21-26-02=Extract Fan
VENT-AVNCS SKIN VALVE FAULT
Aircraft configuration prior to reset:

Blower/Exract fans in AUTO, Ditching pushbutton OFF.

Circuit breakers to reset:

Steps to clear warning:

Open Y17 C/B for 2 seconds, then close. If no help, open all three breakers for 2 seconds,
then close.

Reset duration:

90 seconds.

Results of power up test or reset:

Pass: Ecam fault disappears.


Fail: Ecam fault remains. Perform CFDS AVEC test.

Notes:

Make sure the deactivation switch on skin air valve is in the "ON" position.

Sign off:

AMM21-26-00-710-001.

Applicable deferrals:

MEL21-26-03=SkinAirInletBypassValve.
MEL21-26-04=SkinAirOutletValve.
MEL21-26-05=Skin Air Inlet Valve.
VENT-AVNCS SYS FAULT
Aircraft configuration prior to reset:

Blower/Exract fans in AUTO, Ditching pushbutton OFF.

Circuit breakers to reset:

Steps to clear warning:

First perform a AVEC test through CFDS. If no help, open Y17 C/B for 2 seconds, then close. If
still no help, open all three breakers for 2 seconds, then close.

Reset duration:

90 seconds.

Results of power up test or reset:

Pass: Ecam fault disappears.


Fail: Ecam fault remains.

Notes:

No notes at this time.

Sign off:

AMM21-26-00-710-001.

Applicable deferrals:

MEL21-26-10=Avionics Equipment Vent Computer.


AUTO FLT-A/P 1(2) DISPLAYED IN INOP STATUS
Aircraft configuration prior to reset:

Turn off both flight directors. Both engines off.

Circuit breakers to reset:

Steps to clear warning:

Open associated breaker for 10 seconds, then reset. Do not reset again for at least two
minutes. If reset fails, power down aircraft.

Reset duration:

120 seconds, triple click.

Results of power up test or reset:

Pass: Message disappears.


Fail: Message remains, perform CFDS AFS test.

Notes:

(Please Wait), will be displayed on MCDU, do not touch MCDU for 120 seconds.

Sign off:

AMM22-91-00-710-001. (AFS Ground Scan)


AMM22-91-00-701-001. (AFS Test)

Applicable deferrals:

MEL22-83-01=FMGC.
MEL22-10-01=Autopilot.
AUTO FLT-A/P OFF DISPLAYED ON GROUND
Aircraft configuration prior to reset:

ECAM warning displayed and will not clear. Engines shut down.

Circuit breakers to reset:

None

Steps to clear warning:

Select AP1 pushbutton on FCU, the pushbutton will, illuminate. Push the red autopilot
disconnect button on one of the sidesticks.

Reset duration:

10 seconds.

Results of power up test or reset:

Pass: Message will clear and not recall.


Fail: Red AP OFF message will display.

Notes:

A/P pushbuttons must not be selected before starting engines. If selected, and engines are
started, the message is latched and will not clear. If this occurs after engine start, shut engines
down then complete steps above.

Sign off:

AMM22-91-00-710-001. (AFS Ground Scan)


AMM22-96-00-710-001-A. (AFS Test)

Applicable deferrals:

MEL22-10-01=Autopilot Systems.
AUTO FLT-A/THR OFF DISPLAYED ON GROUND
Aircraft configuration prior to reset:

ECAM warning displayed and will not clear. Engines shut down.

Circuit breakers to reset:

None

Steps to clear warning:

Select A/THR pushbutton on FCU, the pushbutton will illuminate, then push the red instinctive
disconnect button on one of the thrust levers. If message is still displayed, cycle the FADEC
switches on the 50VU, if no help reset FCU’s then FMGC’s then try realigning ADIRU’s.

Reset duration:

10 seconds.

Results of power up test or reset:

Pass: Message will clear and not recall.


Fail: A/THR OFF message will display.

Notes:

A/THR pushbutton must not be selected before starting engines. The message is latched and
will not clear using the CLR key on the ECAM control panel. If this occurs after engines start,the
message will be reset(cleared) upon takeoff power selection. (Thanks Chute for the update)

Sign off:

AMM22-91-00-710-001. (AFS Ground Scan)


AMM22-96-00-710-001-A. (AFS Test)

Applicable deferrals:

MEL22-30-01=Autothrust Function.
AUTO FLT-FCU 1(2) FAULT
Aircraft configuration prior to reset:

None specific.

Circuit breakers to reset:

Steps to clear warning:

Open associated breaker for 7 minutes, then reset.

Reset duration:

10 seconds.

Results of power up test or reset:

Pass: Message disappears.


Fail: Message remains.

Notes:

(Please Wait), will be displayed on MCDU, do not touch MCDU for 120 seconds.

Sign off:

AMM22-91-00-710-001. (AFS Ground Scan)


AMM22-96-00-710-001-A. (AFS Test)

Applicable deferrals:

MEL22-81-01=FCU
AUTO FLT-RUDDER TRAVEL LIMIT 1(2) FAULT
Aircraft configuration prior to reset:

Both engines stopped and hydraulics off.

Circuit breakers to reset:

Steps to clear warning:

First, reset associated FAC pushbutton. If no help, open associated FAC breakers for 10
seconds, then close.

Reset duration:

90 seconds.

Results of power up test or reset:

Pass: Fault messages disappear.


Fail: Message remains.

Notes:

After reset, energize hydraulics, varify no Yaw damper message display.

Sign off:

AMM22-91-00-710-001. (AFS Ground Scan)


AMM22-96-00-710-001-A. (AFS Test)

Applicable deferrals:

MEL27-23-01=Rudder Travel Limiter System.


AUTO FLT-RUDDER TRAVEL LIMIT SYSTEM FAULT
Aircraft configuration prior to reset:

Both engines stopped and hydraulics off.

Circuit breakers to reset:

Steps to clear warning:

First, reset associated FAC pushbutton. If no help, open associated FAC breakers for 10
seconds, then close.

Reset duration:

90 seconds.

Results of power up test or reset:

Pass: Fault messages disappear.


Fail: Message remains.

Notes:

After reset, energize hydraulics, varify no Yaw damper message display.

Sign off:

AMM22-91-00-710-001. (AFS Ground Scan)


AMM22-96-00-710-001-A. (AFS Test)

Applicable deferrals:

MEL27-23-01=Rudder Travel Limiter System.


AUTO FLT-RUDDER TRIM 1(2) FAULT
Aircraft configuration prior to reset:

Both engines stopped and hydraulics off.

Circuit breakers to reset:

Steps to clear warning:

First, reset associated FAC pushbutton. If no help, open associated FAC breakers for 10
seconds, then close.

Reset duration:

90 seconds.

Results of power up test or reset:

Pass: Fault messages disappear.


Fail: Message remains.

Notes:

After reset, energize hydraulics, varify no Yaw damper message display.

Sign off:

AMM22-91-00-710-001. (AFS Ground Scan)


AMM22-96-00-710-001-A. (AFS Test)

Applicable deferrals:

MEL27-22-01=Rudder Trim Systems.


AUTO FLT-RUDDER TRIM SYSTEM FAULT
Aircraft configuration prior to reset:

Both engines stopped and hydraulics off.

Circuit breakers to reset:

Steps to clear warning:

First, reset associated FAC pushbutton. If no help, open associated FAC breakers for 10
seconds, then close.

Reset duration:

90 seconds.

Results of power up test or reset:

Pass: Fault messages disappear.


Fail: Message remains.

Notes:

After reset, energize hydraulics, varify no Yaw damper message display.

Sign off:

AMM22-91-00-710-001. (AFS Ground Scan)


AMM22-96-00-710-001-A. (AFS Test)

Applicable deferrals:

MEL27-22-01=Rudder Trim Systems.


AUTO FLT-YAW DAMPER 1(2) FAULT
Aircraft configuration prior to reset:

Both engines stopped and hydraulics off.

Circuit breakers to reset:

Steps to clear warning:

First, reset associated FAC pushbutton. If no help, open associated FAC breakers for 10
seconds, then close. If yaw damper is a class 2, then cycle FAC’s with hydraulics on.

Reset duration:

90 seconds.

Results of power up test or reset:

Pass: Fault messages disappear.


Fail: Message remains.

Notes:

After reset, energize hydraulics, varify no Yaw damper message display.

Sign off:

AMM22-91-00-710-001. (AFS Ground Scan)


AMM22-96-00-710-001-A. (AFS Test)

Applicable deferrals:

MEL22-63-01=Yaw Dampers.
BARO REF FAULT DISPLAYED
Aircraft configuration prior to reset:

Both flight directors off.

Circuit breakers to reset:

Steps to clear warning:

Open FAC #1 breaker for 10 seconds, then reset.

Reset duration:

10 seconds.

Results of power up test or reset:

Pass: Message disappears.


Fail: Message remains.

Notes:

No notes at this time.

Sign off:

AMM22-91-00-710-001. (AFS Ground Scan)


AMM22-96-00-710-001-A. (AFS Test)

Applicable deferrals:

MEL22-81-01=FCU.
MCDU 1 (2) SCREEN BLANK
Aircraft configuration prior to reset:

No specific.

Circuit breakers to reset:

Steps to clear warning:

Open associated breaker for 30 seconds, then reset.

Reset duration:

45 seconds.

Results of power up test or reset:

Pass: The page is displayed.


Fail: Screen remains blank.

Notes:

No notes at this time.

Sign off:

AMM22-70-00-710-001

Applicable deferrals:

MEL22-82-01=MCDU
OFFSIDE RANGE MODE ON NAV DISPLAY

Aircraft configuration prior to reset:

Turn off both flight directors. Both engines off.

Circuit breakers to reset:

Steps to clear warning:

Open associated breaker for 10 seconds, then reset. Do not reset again for at least two
minutes.

Reset duration:

120 seconds.

Results of power up test or reset:

Pass: Message disappears.


Fail: Message remains, perform CFDS AFS test.

Notes:

(Please Wait), will be displayed on MCDU, do not touch MCDU for 120 seconds.

Sign off:

AMM22-91-00-710-001. (AFS Ground Scan)


AMM22-96-00-710-001-A. (AFS Test)

Applicable deferrals:

MEL22-83-01=FMGC.
OPPOSITE FM IN PROCESS DISPLAYED ON MCDU
Aircraft configuration prior to reset:

Turn off both flight directors. Both engines off.

Circuit breakers to reset:

Steps to clear warning:

Open associated breaker for 10 seconds, then reset. Do not reset again for at least two
minutes.

Reset duration:

120 seconds.

Results of power up test or reset:

Pass: Message disappears.


Fail: Message remains.

Notes:

(Please Wait), will be displayed on MCDU, do not touch MCDU for 120 seconds.

Sign off:

AMM22-91-00-710-001. (AFS Ground Scan)


AMM22-96-00-710-001-A. (AFS Test)

Applicable deferrals:

MEL22-83-01=FMGC.
RUDDER ARTIFICIAL FEEL INOP
Aircraft configuration prior to reset:

None specific.

Circuit breakers to reset:

Steps to clear warning:

Open rudder artificial feel breaker for 10 seconds, then reset.

Reset duration:

10 seconds.

Results of power up test or reset:

Pass: Message disappears.


Fail: Message remains.

Notes:

No notes at this time.

Sign off:

AMM22-61-00-710-001

Applicable deferrals:

MEL27-23-01=Rudder Travel Limit


SIDE STICK LOCK
Aircraft configuration prior to reset:

None specific.

Circuit breakers to reset:

Steps to clear warning:

Open side stick lock breaker for 10 seconds, then reset.

Reset duration:

10 seconds.

Results of power up test or reset:

Pass: Message disappears.


Fail: Message remains.

Notes:

No notes at this time.

Sign off:

AMM27-96-00-710-003 (Priority Test).

Applicable deferrals:

MEL=None.
WINDSHEAR FAULT
Aircraft configuration prior to reset:

Aircraft stopped, flaps up.

Circuit breakers to reset:

Steps to clear warning:

Select FAC #1 pushbutton off, pull FAC #1 breaker for 30 seconds, then reset breaker and
FAC #1 pushbutton.

Reset duration:

90 seconds.

Results of power up test or reset:

Pass: Message disappears.


Fail: Message remains.

Notes:

No notes at this time.

Sign off:

AMM22-60-00-710-004 (CFDS/AFS/WindShear)
AMM34-41-00-740-002 (Bite Test Weather Radar)

Applicable deferrals:

MEL22-66-03-Windshear Detection.
ACARS TRANSMISSION PROBLEMS
Aircraft configuration prior to reset:

None specfic.

Circuit breakers to reset:

Steps to clear warning:

Open associated breaker for 5 seconds, then close.

Reset duration:

180 seconds.

Results of power up test or reset:

Pass: ACARS standby memo disappears and weather uplink is succesful.


Fail: Still inop.

Notes:

If NO COMM is reported durning flight, yet ACARS operates ok on ground, suspect failure of
VHF3 transmissions on some frequencies.

Sign off:

AMM23-24-00-710-001.
AMM46-24-00-710-001.

Applicable deferrals:

MEL23-24-01=ACARS.
ACP INOP
Aircraft configuration prior to reset:

None specfic.

Circuit breakers to reset:

Steps to clear warning:

Turn “OFF” all RMP’s then turn “ON” to reset. If no help, reset associated ACP breakers.

Reset duration:

120 seconds.

Results of power up test or reset:

Pass: ACP functions normally.


Fail: Still will not change.

Notes:

No notes at this time.

Sign off:

AMM23-51-00-740-002.

Applicable deferrals:

MEL23-51-02=Audio Control Panel Systems (ACP).


AMU (AUDIO MANAGEMENT UNIT) FAULT
Aircraft configuration prior to reset:

None specfic.

Circuit breakers to reset:

Steps to clear warning:

Open associated breaker for 2 seconds, then close. If no help reset C/B's M-02, M-03, M-04.

Reset duration:

10 seconds.

Results of power up test or reset:

Pass: AMU functions normally.


Fail: Still inop.

Notes:

No notes at this time.

Sign off:

AMM23-51-00-740-002.

Applicable deferrals:

MEL23-51-01=Audio Management Unit (AMU).


PASSENGER ADDRESS SYSTEM INOP
Aircraft configuration prior to reset:

Aircraft on ground

Circuit breakers to reset:

Steps to clear warning:

First try reseting CIDS director at PTP. If no help, open circuit breakers for 10 seconds, then
reset.

Reset duration:

180 seconds.

Results of power up test or reset:

Pass: Passenger address system works.


Fail: Passenger address system still inop.

Notes:

DEU-A controls lights, call signs and speakers. DEU-B controls interphone, P/A, call, and
EVAC.

Sign off:

AMM23-73-00-740-005.

Applicable deferrals:

MEL23-31-01=Passenger Adress Systems Inop.


CIDS SYSTEM FAULTS
Aircraft configuration prior to reset:

Aircraft on ground, both engines stopped, all cabin doors closed.

Circuit breakers to reset:

Steps to clear warning:

First, try reset at PTP. If no help open all breakers for 10 seconds, then close.

Reset duration:

120 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

Cabin lights will flash durning test. Test pass will be displayed on the PTP upon successful
power up.

Sign off:

AMM23-73-00-740-005.

Applicable deferrals:

MEL23-73-01=CIDS Director.
COM-HF 1 (2) INOP
Aircraft configuration prior to reset:

None specfic.

Circuit breakers to reset:

Steps to clear warning:

Open associated breaker for 5 seconds, then close.

Reset duration:

10 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

No notes at this time.

Sign off:

AMM23-11-00-740-001.

Applicable deferrals:

MEL23-11-01=HF Communication System.


COM-VHF 1(2)(3) EMITTING
Aircraft configuration prior to reset:

None specfic.

Circuit breakers to reset:

Steps to clear warning:

First, check the transmission key on audio panel, then the side stick radio select button, and
then the hand held mic for a stuck button. If no help, open associated breaker for 2 seconds, then
close.

Reset duration:

10 seconds.

Results of power up test or reset:

Pass: Message disappears.


Fail: Message remains.

Notes:

No notes at this time.

Sign off:

AMM23-12-00-710-001.

Applicable deferrals:

MEL23-12-01=VHF Communications Systems.


COM-VHF TRANSMISSION PROBLEMS
Aircraft configuration prior to reset:

None specfic.

Circuit breakers to reset:

Steps to clear warning:

Open associated circuit breaker for 2 seconds, then close.

Reset duration:

10 seconds.

Results of power up test or reset:

Pass: Message disappears.


Fail: Message remains.

Notes:

No notes at this time.

Sign off:

AMM23-12-00-710-001.

Applicable deferrals:

MEL23-12-01=VHF Communications Systems.


DEU-A FAULT ON CIDS
Aircraft configuration prior to reset:

Aircraft on ground

Circuit breakers to reset:

Steps to clear warning:

First try reseting CIDS director at PTP. If no help, open circuit breakers for 10 seconds, then
reset.

Reset duration:

180 seconds.

Results of power up test or reset:

Pass: Fault clears from cids


Fail: Fault remains.

Notes:

DEU-A controls lights, call signs and speakers. DEU-B controls interphone, P/A, call, and
EVAC.

Sign off:

AMM23-73-00-740-005.

Applicable deferrals:

MEL23-73-02=CIDS (Decoder Encoder Unit) DEU-A.


DEU-B FAULT ON CIDS
Aircraft configuration prior to reset:

Aircraft on ground

Circuit breakers to reset:

Steps to clear warning:

First try reseting CIDS director at PTP. If no help, open circuit breakers for 10 seconds, then
reset.

Reset duration:

180 seconds.

Results of power up test or reset:

Pass: Fault clears from cids


Fail: Fault remains.

Notes:

DEU-A controls lights, call signs and speakers. DEU-B controls interphone, P/A, call, and
EVAC.

Sign off:

AMM23-73-00-740-005.

Applicable deferrals:

MEL23-73-03A=CIDS (Decoder Encoder Unit) DEU-B.


FLIGHT INTERPHONE INOP
Aircraft configuration prior to reset:

No specific.

Circuit breakers to reset:

Steps to clear warning:

Open circuit breaker for 2 seconds, then close. If no help reset breaker for DEU”B”-M7.

Reset duration:

10 seconds.

Results of power up test or reset:

Pass: Flight interphone works.


Fail: Still inop.

Notes:

DEU-A controls lights, call signs and speakers. DEU-B controls interphone, P/A, call, and
EVAC.

Sign off:

AMM23-73-00-740-005.

Applicable deferrals:

MEL23-43-02=Crewmember Interphone System.


FORWARD ATTENDANT PANEL (FAP) LOCKED UP
Aircraft configuration prior to reset:

No specific.

Circuit breakers to reset:

Steps to clear warning:

Open circuit breaker for 5 seconds, then close.

Reset duration:

5 seconds.

Results of power up test or reset:

Pass: Panel not lock up.


Fail: Fault remains.

Notes:

Cabin lights will flash durning test. Test pass will be displayed on the PTP upon successful
power up.

Sign off:

AMM23-73-00-740-005.

Applicable deferrals:

MEL23-73-04=FAP(OLD).
MEL23-73-08=FAP(NEW).
FWD FLIGHT ATTENDANT PTP PANEL INOP
Aircraft configuration prior to reset:

No specific.

Circuit breakers to reset:

Steps to clear warning:

Open circuit breaker for 5 seconds, then close.

Reset duration:

5 seconds.

Results of power up test or reset:

Pass: Panel powers up.


Fail: Panel inop.

Notes:

PTP = Programmed and Test Panel.

Sign off:

AMM23-73-00-740-005.

Applicable deferrals:

MEL23-73-07=FTP.
RMP LOCKED UP OR WINDOW BLANK
Aircraft configuration prior to reset:

None specfic.

Circuit breakers to reset:

Steps to clear warning:

Turn off all RMP’s then on to reset. If no help, open all above circuit breakers for 2 seconds,
then close.

Reset duration:

2 seconds.

Results of power up test or reset:

Pass: RMP functions normally.


Fail: Still locked up.

Notes:

RMP lock up could be caused by another RMP that otherwise functions normally. Thats why all
three must be reset.

Sign off:

AMM23-13-00-710-001.

Applicable deferrals:

MEL23-13-01=Radio Management Panel (RMP).


ELEC-BCL 1(2) FAULT
Aircraft configuration prior to reset:

Aircraft on ground.

Circuit breakers to reset:

Steps to clear warning:

Reset using associated battery pushbutton in overhead. If no help, open associated breakers
for 1 second, then close.

Reset duration:

10 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

All curcuit breakers are located on the 105VU in the E&E panel.

Sign off:

AMM24-38-00-710-001.

Applicable deferrals:

No MEL
ELEC-CIRCUIT BREAKER TRIPPED
Aircraft configuration prior to reset:

No specific.

Circuit breakers to reset:

Tripped breaker.

Steps to clear warning:

Reset tripped circuit breaker only once, If unsuccessful, do not make second attempt,
troubleshoot and fix problem.

Reset duration:

N/A.

Results of power up test or reset:

Pass: Message clears, associated system operates.


Fail: Fault remains.

Notes:

If no tripped breakers can be located, a green circuit breaker in the identified panel has failed.
Remember, green breakers do exist in relay panels 105VU and 106VU located in the E&E bay.

Sign off:

US AMM CHAPTER20-24-20.

Applicable deferrals:

MEL ?
ENGINE GENERATORS PARAMETERS NOT SHOWN
Aircraft configuration prior to reset:

Aircraft on ground, Engines shut down.

Circuit breakers to reset:

Steps to clear warning:

Open associated circuit breakers for 1 second, then close.

Reset duration:

1 seconds.

Results of power up test or reset:

Pass: Engine parameters return to nomral.


Fail: Fault remains.

Notes:

Associated GCU or EGIU is at fault, There is a reset button on each GCU (Nose E&E).

Sign off:

TSM24-22-00-810-805 (#1 engine parameter check).


TSM24-22-00-810-807 (#2 engine parameter check).

Applicable deferrals:

MEL24-20-01=Engine Driven Generator.


GROUND POWER WON’T CONNECT, NO AVAIL LIGHT IN
PUSHBUTTON
Aircraft configuration prior to reset:

Aircraft on ground, engines stopped, APU stopped, ground power connected.

Circuit breakers to reset:

Steps to clear warning:

Open breaker , then close.

Reset duration:

1 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

No notes at this time.

Sign off:

AMM24-41-00-740-002.

Applicable deferrals:

MEL24-41-01=External.Power.Control
MEL24-41-02=”Not.in.use”or“AVIL”light.inop
MEL24-41-03=EXT PWR PB Switch
TRANSFORMER RECTIFIER PROBLEMS
Aircraft configuration prior to reset:

Aircraft on ground.

Circuit breakers to reset:

Steps to clear warning:

First, reset T/R’s through MCDU or all three using guarded button on 103VU panel in E&E bay.
If unsuccessful, reset associated breaker.

Reset duration:

1 seconds.

Results of power up test or reset:

Pass: T/R operated correctly.


Fail: Fault remains.

Notes:

If ESS TR3 is in operation with TR1 & TR2 sericable, release the AC ESS FEED pushbutton
on the 35VU, than push the AC ESS FEED pushbutton. ESS TR3 will return to standby.

Sign off:

TSM24-30-00-810-801 (#1 TR test).


TSM24-30-00-810-802 (#2 TR test).

Applicable deferrals:

MEL24-30-01=Transformer/Rectifier Units (TR).


CREW SEAT PROBLEMS
Aircraft configuration prior to reset:

No specific.

Circuit breakers to reset:

Steps to clear warning:

Open associated circuit breakers for 1 second, then close.

Reset duration:

1 second.

Results of power up test or reset:

Pass: Seat operates correctly.


Fail: Fault remains.

Notes:

Additional circuit breaker is located under each seat on the control box.

Sign off:

AMM25-11-00-710-001.

Applicable deferrals:

MEL25-11-01=Pilot Seat Adjustment.


OVEN OR TIMER
Aircraft configuration prior to reset:

No specific.

Circuit breakers to reset:

Steps to clear warning:

Open associated circuit breakers for 1 second, then close.

Reset duration:

1 seconds.

Results of power up test or reset:

Pass: Oven operates correctly.


Fail: Fault remains.

Notes:

No notes at this time.

Sign off:

AMM25-35-00-710-015.

Applicable deferrals:

NEF.
COND/AIR-AFT CARGO HEAT/VENT FAULT
Aircraft configuration prior to reset:

On ground.

Circuit breakers to reset:

Steps to clear warning:

Open both circuit breakers for 1 second, then close.

Reset duration:

28 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

During reset, cargo heat trim air valves cycles.

Sign off:

AMM21-28-00-710-006.

Applicable deferrals:

MEL21-28-04=AFT.Cargo.Extraction.Fan.
MEL21-28-05=AFT Cargo Isolation Valves.
SDCU TROUBLE SHOOT DATA (TSD) INFO
Aircraft configuration prior to reset:

On ground.

Circuit breakers to reset:

No breakers

Steps to clear warning:

Do a read-out of the TROUBLE SHOOTING DATA from the CFDS.

The TSD shows the total number of smoke detectors installed on the smoke detection loop, e.g. xxxx xxxx xxxx xxxx
aa/bb (aa=bb shows all installed smoke detectors). The cabin layout specifies the number of smoke detectors.

If the TSD gives the complementary information xxxx xxxx xxxx xxxx A/b
(b < A)

- replace the SD (b) counted counterclockwise from the SDCU Channel 2.

- If the fault continues: replace the SD(b+1) counted counterclockwise from SDCU Channel 2 until the TSD gives the
information xxxx xxxx xxxx xxxx A/B (A=B)

If the TSD gives the complementary information xxxx xxxx xxxx xxxx a/B
(a < B)
- replace the SD(a) counted clockwise from the SDCU Channel 1.

- If the fault continues: replace the SD(a+1) counted clockwise from SDCU Channel 1 until the TSD gives the
information xxxx xxxx xxxx xxxx A/B (A=B).

A319 & A320 Configuration

A321 Configuration

Notes:

If system will not test, than you can not apply MEL.

Applicable deferrals:

MEL26-17-02=Smoke Detection Control Unit (SDCU).


SMOKE - FWD/AFT CARGO SMOKE DET
Aircraft configuration prior to reset:

On ground.

Circuit breakers to reset:

Steps to clear warning:

Open both circuit breakers for 60 second, then close both at same time.

Reset duration:

80 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

Wait two minutes after reset before testing system.

Sign off:

AMM26-16-00-710-001.

Applicable deferrals:

MEL26-16-03=FWD Cargo Smoke Det.


MEL26-16-04=AFT/Bulk Cargo Smoke Det.
SMOKE - LAVATORY DET FAULT
Aircraft configuration prior to reset:

On ground.

Circuit breakers to reset:

Steps to clear warning:

Open both circuit breakers for 60 second, then close both at same time.

Reset duration:

80 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

Wait two minutes after reset before testing system.

Sign off:

AMM26-17-00-710-001.

Applicable deferrals:

MEL26-17-01=Lavatory Smoke Detection System.


SMOKE - SDCU MAINT. MESSAGE (CLASS 2)
Aircraft configuration prior to reset:

On ground.

Circuit breakers to reset:

Steps to clear warning:

Open both circuit breakers for 60 second, then close both at same time.

Reset duration:

80 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

Wait two minutes after reset before testing system.

Sign off:

AMM26-16-00-710-001.

Applicable deferrals:

MEL26-17-02=Smoke Detection Control Unit (SDCU).


F/CTL-AILERON SERVO FAULT
Aircraft configuration prior to reset:

Aircraft on ground.

Circuit breakers to reset:

Steps to clear warning:

First, reset applicable ELAC pushbutton. If no help, open associated breaker for 5 seconds. Pushbutton to remain
in “ON” position during breaker reset.

Reset duration:

20 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

If fault is isolated to a servo, change the servo valve first prior to changing the complete servo control.

Sign off:

AMM27-93-00-710-001.

Applicable deferrals:

MEL27-14-01=Aileron.Servo.Controls.
MEL27-14-02=Aileron indications on ECAM inop.
F/CTL-ALTN LAW DISPLAY AT ENGINE START
Aircraft configuration prior to reset:

On ground, with engines running, wheels chocked.

Circuit breakers to reset:

None

Steps to clear warning:

With engines running, set parking brake, use overhead pushbuttons to switch “OFF” engine hydraulics, when
hydraulics are depressurized, select “OFF” ELAC #1 and #2 using overhead swich. After 3 seconds, switch ELAC #1
and ELAC #2 “ON”. After approx 15 seconds, select hydraulics back “ON”.

Reset duration:

30 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

Follow reset steps closely.

Sign off:

AMM27-93-00-710-001.

Applicable deferrals:

No MEL.
F/CTL-ELAC 1(2) FAULT
Aircraft configuration prior to reset:

Aircraft on ground.

Circuit breakers to reset:

Steps to clear warning:

First, reset applicable ELAC pushbutton. If no help, open associated breaker for 5 seconds. Pushbutton to remain
in “ON” position during breaker reset.

Reset duration:

20 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

ELAC #1 controls left outboard (Blue) and right inboard (Green) aileron servos. ELAC #2 controls Left inboard
(Green) and right outboard (Blue) ailerons servos. ELAC #1 is primary in roll, ELAC #2 is primary in pitch. ELAC #1
controls outboard (Blue) elevator servos. ELAC #2 controls inboard left (Green) & inboard right (Yellow) elevator
servos.

Sign off:

AMM27-93-00-710-001.

Applicable deferrals:

MEL27-93-01=ELEC.
F/CTL-FCDC 1(2) FAULT
Aircraft configuration prior to reset:

On ground, hydraulics depressurized.

Circuit breakers to reset:

Steps to clear warning:

Open circuit breakers for 5 second, then close.

Reset duration:

20 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

FCDC=Flght Control Data Concentrators.

Sign off:

AMM27-96-00-710-001.

Applicable deferrals:

MEL27-95-01=FCDC.
F/CTL-FLAP/SLAT 1 (2) FAULTS OR SLOW OPERATION
Aircraft configuration prior to reset:

On ground, hydraulics depressurized, engines stopped.

Circuit breakers to reset:

Steps to clear warning:

Open associated breakers for 5 seconds, then close.Only reset one breaker at time, reseting both system breakers
could lock out WTB.

Reset duration:

60 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

Slats slow or flaps slow message will display only durning operation. Remember running slats/flaps without all
hydraulics on can cause these faults to display. Slats use Blue & Green hydraulics. Flaps use Yellow & Green
hydraulics.

Sign off:

AMM27-51-00-740-002.

Applicable deferrals:

MEL27-51-01=Slat/Flap Control System (SFCS).


F/CTL-FLAP/SLAT INDICATION AMBER
Aircraft configuration prior to reset:

On ground, hydraulics depressurized.

Circuit breakers to reset:

Steps to clear warning:

Open circuit breakers for 5 second, then close.

Reset duration:

20 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

If ECAM upper flap/slat indications are amber, reset system #1. If not reset system #2.

Sign off:

AMM 27-93-00-710-001

Sign off:

AMM27-51-00-740-002.

Applicable deferrals:

MEL27-51-01=SFCS.
F/CTL-FLAPS(SLATS) LOCKED
Aircraft configuration prior to reset:

On ground, hydraulics depressurized.

Circuit breakers to reset:

None

Steps to clear warning:

Reset wing tip brakes though MCDU/CFDS/SFCC/TEST/RESET.

Reset duration:

30 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

After reset of wing tip brakes, fault message clears.

Sign off:

AMM27-51-00-710-002.

Applicable deferrals:

MEL27-51-02=Flap Wing Tip Brake Solenoids.


F/CTL-MAINENANCE STATUS (CLASS 2)
Aircraft configuration prior to reset:

On ground, hydraulics depressurized, engines stopped, ADIRU’s aligned.

Circuit breakers to reset:

Steps to clear warning:

Open circuit breakers for 5 second, then close.

Reset duration:

20 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

If time, run a ground scan in CFDS/FCTL/EFCS #1 to identify cause of message.

Sign off:

AMM27-96-00-710-001.

Applicable deferrals:

MEL27-00=Class 2 Maintenance Message.


F/CTL-SEC 1(2)(3)FAULT OR SPLR FAULT
Aircraft configuration prior to reset:

Aircraft on ground. Hydraulics depressurized.

Circuit breakers to reset:

Steps to clear warning:

First, reset applicable SEC pushbutton. If no help, open associated breaker for 5 seconds, then reset. The
pushbutton to remain in "ON" postion during breaker reset.

Reset duration:

20 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

If Hydraulics are pressurized, pushbutton reset will not be successful. SEC #1 controls spoilers 3 & 4. SEC #2
controls spoilers 5. SEC #3 controls spoilers 1 & 2.

Sign off:

AMM27-94-00-710-001(SEC#3).
AMM27-94-00-710-002(SEC#1).
AMM27-94-00-710-003 (SEC #2).

Applicable deferrals:

MEL27-92-01=SEC’s.
MEL27-92-02=GND Spoilers.
SIDE STICK PRIORTY MESSAGE
Aircraft configuration prior to reset:

Aircraft on ground.

Circuit breakers to reset:

Steps to clear warning:

First, reset all FAC/SEC/ELAC overhead pushbuttons. If no help, reset ELAC circuit breakers followed by
performing a side stick priorty test.

Reset duration:

20 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

Check PFR for associated messages. If you have any associated faults T/S IAW TSM.

Sign off:

AMM27-96-00-710-003 (Priority Test).

Applicable deferrals:

MEL27-92-06=Side Stick Dual Input Warning System.


THS DIDN’T RETURN TO ZERO AFTER LANDING
Aircraft configuration prior to reset:

On ground.

Circuit breakers to reset:

None

Steps to clear warning:

Reset ELAC’s using overhead pushbutton switches. Select both ELAC switches off, then on. THS will return to
zero.

Reset duration:

8 seconds.

Results of power up test or reset:

Pass: THS zeros.


Fail: THS stays.

Notes:

THS=Trimmable Horizontal Stabilizer.

Sign off:

AMM27-93-00-810-945.

Applicable deferrals:

MEL27-44-01=Stabilizer Actuator Electric Motors.


APU FUEL LP VALVE FAULT MESSAGE

Aircraft configuration prior to reset:

Fuel APU LP valve fault message triggered when the APU master switch is selected off durning autoshut down.

Circuit breakers to reset:

Steps to clear warning:

First, cycle the APU master switch "ON" then "OFF". If no help cycle the associated circuit breakers.

Reset duration:

10 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

No notes at this time.

Sign off:

AMM28-29-00-710-001

Applicable deferrals:

MEL49-70-01=APU INOP.
CENTER TANK LOW PRESSURE WARNING
Aircraft configuration prior to reset:

Less than 400 pounds of fuel in the center tank.

Circuit breakers to reset:

None

Steps to clear warning:

With less then 400lbs in center tank, select the mode switch to Auto. The center pumps should not run with low
center tank fuel.

Reset duration:

N/A.

Results of power up test or reset:

Pass: Center tank pumps shows “cross line green”


Fail: Pumps run in AUTO and no fuel in center tank.

Notes:

This could be a spurious fault with less than 400LBS in center tank, check previous PFR for history.

Sign off:

AMM28-21-00-720-001

Applicable deferrals:

MEL28-21-02=Center Tank System.


FUEL-AUTOFEED FAULT
Aircraft configuration prior to reset:

Center tank greater then 550lbs with wing tanks below 11,000.

Circuit breakers to reset:

None

Steps to clear warning:

The fault is indicated if either wing tank quantity becomes less than 11,023lbs when center tank is above 550lbs.
When fuel is reconfigured, fault will clear.

Reset duration:

N/A.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

Fuel.burn.sequence:

1st)Center.tanks.(greater.pump.output.pressure).

2nd).Inner.wing.tanks

3rd) At approx 1700lbs in either inner tank, all 4 transfer valves open and outer wing tank fuel flows to the inner tanks
for consumption.

Sign off:

AMM28-42-00-710-001

Applicable deferrals:

MEL28-20-01=Automatic Fuel Feed System.


FUEL-FQI 1(2) FAULT
Aircraft configuration prior to reset:

Aircraft on ground.

Circuit breakers to reset:

Steps to clear warning:

Open associated breakers for 3 seconds, then close. During reset the intercell transfer valves cycle.

Reset duration:

80 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

Each reset causes fuel to move form the outer cells to the inner cells. Too many resets can cause fuel
configuration problems.

Sign off:

AMM28-42-00-710-001.

Applicable deferrals:

MEL28-40-02=Fuel Quantity Indicating Computer.


INTERCELL TRANSFER VALVES OPEN
Aircraft configuration prior to reset:

On ground, refueling, with inner tanks greater than 1700lbs.

Circuit breakers to reset:

Steps to clear warning:

The Intercell transfer valves normally close when the refuel door opens. If valves fail to close properly, cycle
associated circuit breakers.

Reset duration:

10 seconds.

Results of power up test or reset:

Pass: Valves close properly when refuel door opens.


Fail: Valves remain open.

Notes:

Nuisance, caused by fuel movement in tanks due to aircraft attitude changes.

Sign off:

AMM28-46-00-740-001.

Applicable deferrals:

MEL28-15-01=Intercell Transfer Valves.


HYD RESERVOIR LOW AIR PRESSURE MSG
Aircraft configuration prior to reset:

On ground.

Circuit breakers to reset:

Steps to clear warning:

To clear, run engines or pressurize hydraulics reservoirs with APU air. If no help, check the reservoir gauge. If still
low, service it manually with N2 to 45 PSI. If no help, cycle circuit breakers.

Reset duration:

10 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

This fault normally occurs after working on hydraulic system.All 3 systems pressure switches are set at 40psi. The
blue system has an additional press switch set at 45PSI displayed on ground only. Remember some A/C have a APU
boost setting.

Sign off:

AMM29-14-00-720-001.

Applicable deferrals:

MEL29-30-04A RSVR LO AIR PRESSURE.


HYDRAULIC SYSTEM SCHEMATIC
PTU FAULT
Aircraft configuration prior to reset:

On ground with engines running.

Circuit breakers to reset:

N34

Normal PTU reset

1st) Yellow electric pump “ON”, wait 2 seconds.Turn yellow electric pump “OFF”

2nd) Set brakes, both engine pumps “OFF” yellow electric pumps “ON” , PTU pushbutton “OFF” then to “AUTO”
,yellow electric pumps “OFF”, engine pumps “ON”.

PTU reset cause by cargo door operation:

Reset with engines running.

1) Reset message using master caution P/B switch.

2) Select hydaulic page on ECAM.

3) Select yellow hydraulic electric pump "ON" then "OFF".

4) Wait minimum of 30 seconds.

5) Cycle the PTU switch "ON"-"OFF"-"ON".

6) Select engine #1 green hydraulic pump "OFF", PTU should operate yellow to green.

7) Select engine #1 green hydraulic pump "ON".

8) Select engine #2 yellow hydraulic pump "OFF", PTU should operate green to yellow.

9) Select engine #2 yellow hydraulic pump "ON".

10) ECAM should be normal.

Results of power up test or reset:

Pass: Fault clears.

Fail: Fault remains.


Notes:
PTU fault can be caused by cargo door operation 30 seconds after 2nd engine start.

Sign off:
TSM29-23-00-810-801

Applicable deferrals:

MEL29-23-01=Power Transfer Unit.


ANTI ICE - LEFT OR RIGHT WINDOW
Aircraft configuration prior to reset:

On ground.

Circuit breakers to reset:

Steps to clear warning:

If the warning occurs on the ground with OAT greater then 40°C and AC packs off, turn both packs on cool or
place damp towel on inner pane over sensors for 5 minutes. Open circuit breakers for 5 seconds, then close.

Reset duration:

5 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

If possible, cover sensors from the exterior of the aircraft.

Sign off:

AMM30-42-00-710-001.

Applicable deferrals:

MEL30-42-02=Fixed Lateral & Sliding Window Heat.


ANTI ICE - LEFT OR RIGHT WINDSHIELD
Aircraft configuration prior to reset:

On ground.

Circuit breakers to reset:

Steps to clear warning:

If the warning occurs on the ground with OAT greater then 40°C and AC packs off, turn both packs on cool or
place damp towel on inner pane over sensors for 5 minutes. Open circuit breakers for 5 seconds, then close.

Reset duration:

5 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

If possible, cover sensors from the exterior of the aircraft.

Sign off:

AMM30-42-00-710-001.

Applicable deferrals:

MEL30-42-03=Windshield Heating System.


ANTI ICE - PROBE MESSAGE SYSTEM #1
Aircraft configuration prior to reset:

On ground, probe heat not selected "ON".

Circuit breakers to reset:

Steps to clear warning:

Open associated probe breaker for 1 second, then reset. If no help, open PHC #1 (49VU-D3) for 1 second, then
reset.

Reset duration:

3 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

If probe reset did not clear, reset ADIRU C/B’s. #1=F6,C2 #2=N6,N4 #3=N5,N3

Sign off:

AMM30-31-00-710-001.

Applicable deferrals:

MEL30-31-01/02/03/04/05=Probe Heat.
ANTI ICE - PROBE MESSAGE SYSTEM #2
Aircraft configuration prior to reset:

On ground, probe heat not selected "ON".

Circuit breakers to reset:

Steps to clear warning:

Open associated probe breaker for 1 second, then reset. If no help, open PHC #2 (122VU-Y12) for 1 second, then
reset.

Reset duration:

3 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

If probe reset did not clear, reset ADIRU C/B’s. #1=F6,C2 #2=N6,N4 #3=N5,N3

Sign off:

AMM30-31-00-710-001.

Applicable deferrals:

MEL30-31-01/02/03/04/05=Probe Heat.
ANTI ICE - PROBE MESSAGE SYSTEM #3
Aircraft configuration prior to reset:

On ground, probe heat not selected "ON".

Circuit breakers to reset:

Steps to clear warning:

Open associated probe breaker for 1 second, then reset. If no help, open PHC #3 (122VU-Y16) for 1 second, then
reset.

Reset duration:

3 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

If probe reset did not clear, reset ADIRU C/B’s. #1=F6,C2 #2=N6,N4 #3=N5,N3

Sign off:

AMM30-31-00-710-001.

Applicable deferrals:

MEL30-31-01/02/03/04/05=Probe Heat.
ANTI ICE MESSAGE
Aircraft configuration prior to reset:

On ground, probe heat not selected "ON".

Circuit breakers to reset:

Steps to clear warning:

Open associated circuit breakers for 1 second, then close.

Reset duration:

3 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

No notes at this time.

Sign off:

AMM30-31-00-710-001.

Applicable deferrals:

MEL30-31-01=Probe Heat Computers.


DRAIN MAST HEATER FAULT (FWD/AFT)
Aircraft configuration prior to reset:

On ground.

Circuit breakers to reset:

Steps to clear warning:

Open circuit breakers for 5 second, then close.

Reset duration:

18 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains, CIDS caution light on FAP.

Notes:

If time, perform a bite on associated controller in cargo pit.

Sign off:

AMM30-71-00-710-001

Applicable deferrals:

MEL30-71-01=Waste Water Drain Mast Heating.


ENGINE ANTI ICE FAULT
Aircraft configuration prior to reset:

On ground, engines stopped.

Circuit breakers to reset:

Steps to clear warning:

Open circuit breakers for 1 second, then close. If no help work valve several times, make sure valve is closed.

Reset duration:

3 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

Engine anti-ice valve should be spring loaded closed on the ground with engines off.

Sign off:

AMM30-21-00-710-002 (test with engines running).

Applicable deferrals:

MEL30-21-01/02=Engine Anti Ice.


CFDS FAULT MESSAGE PRINTS IN FLIGHT
Aircraft configuration prior to reset:

Aircraft on ground.

Circuit breakers to reset:

None.

Steps to clear warning:

Go to MCDU-CFDS, the next page. Select ACARS PRINT/PROGRAM. Then select REAL TIME FAIL and WARN
print to OFF. Return to CFDS.

Reset duration:

N/A.

Results of power up test or reset:

Pass: fault message wont auto print.


Fail: fault message still auto prints.

Notes:

Sign off:

N/A

Applicable deferrals:

N/A
Class 2 ACMS message displayed
Aircraft configuration prior to reset:

Aircraft on ground, engines stopped.

Circuit breakers to reset:

Steps to clear warning:

Open associated breakers for 10 seconds, then reset.

Reset duration:

40 seconds.

Results of power up test or reset:

Pass: ACMS message clears.


Fail: Fault remains.

Notes:

ACMS = Aircraft Condition Monitor Systems.

Sign off:

AMM31-36-00-710-001

Applicable deferrals:

MEL31-00 Class 2 Maintenance Message


CLOCK DOESN’T AGREE WITH LOWER ECAM
Aircraft configuration prior to reset:

Aircraft on ground.

Circuit breakers to reset:

Steps to clear warning:

Open associated breaker for 5 seconds, then reset.

Reset duration:

60 seconds.

Results of power up test or reset:

Pass: A/C clock and lower ECAM clock will agree.


Fail: Fault remains.

Notes:

Verify clock is correctly set prior to reset of CFDIU. Clock C/B’s are F11/N02/N03.

Sign off:

AMM31-21-00-710-002.

Applicable deferrals:

MEL31-21-01=Clock System.
DISPLAY UNIT IS BLANK OR HAS DIAGONAL LINE
Aircraft configuration prior to reset:

On ground.

Circuit breakers to reset:

Steps to clear warning:

First select DMC #3 to isolate fault to DU or DMC. If DMC is at fault reset above associated circuit breaker for 5
seconds. If fault is with DU reset these (CAPT PFD/ND = G3/E1) (FO's PFD/ND = R3/R4) (Upper ECAM = E5) (Lower
ECAM = R11).

Reset duration:

5 seconds.

Results of power up test or reset:

Pass: Display operates normally.


Fail: Fault remains.

Notes:

No notes at this time.

Sign off:

AMM31-60-00-710-001. (EIS start)

Applicable deferrals:

MEL31-63-01=Display Units.
MEL31-63-02=Display Management Computers.
DISPLAY UNITS SHOWS TELELOADING
Aircraft configuration prior to reset:

On ground.

Circuit breakers to reset:

Steps to clear warning:

First, attempt to switch affected display unit to DMC #3 using switching panel. Next, open associated display unit
circuit breaker for 10 seconds, then reset.

Reset duration:

5 seconds.

Results of power up test or reset:

Pass: Display unit image is recovered.


Fail: Fault remains.

Notes:

Also try reset of associated DMC. (DMC #1 = E11) (DMC #2 = Q8) (DMC #3 = Q9). All DMC’s must be the same
manufacturer part number.

Sign off:

AMM31-60-00-710-001. (EIS start)

Applicable deferrals:

MEL31-63-01=Display Units.
DMC 1(2)(3) FAULT
Aircraft configuration prior to reset:

On ground.

Circuit breakers to reset:

Steps to clear warning:

Open associated breakers for 5 seconds, then reset.

Reset duration:

5 seconds.

Results of power up test or reset:

Pass: ECAM warning clears, display unit works.


Fail: Fault remains.

Notes:

Use switching panel 8VU to display DMC #3 images.

Sign off:

AMM31-60-00-710-001. (EIS start)

Applicable deferrals:

MEL31-63-02=Display Management Computers.


ECAM PAGE LOCKED

Aircraft configuration prior to reset:

Aircraft on ground, engines stopped.

Circuit breakers to reset:

Steps to clear warning:

Open associated breaker for 5 seconds, then reset.

Reset duration:

60 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

If both FWC’s are reset together, all warnings , will be inoperative durning the reset.

Sign off:

AMM31-50-00-710-004

Applicable deferrals:

MEL31-56-01=ECAM Control Panel.


FLIGHT CONTROL PAGE WON’T AUTO-DISPLAY
Aircraft configuration prior to reset:

Aircraft on ground, doors shut, one engine started.

Circuit breakers to reset:

Steps to clear warning:

Make sure “ALL” pushbutton light on ECAM control panel is extinguished. Move sidestick, If flight control page
doesn’t auto display, open FWC #1 breaker and try again. If successful, FWC is culprit.

Reset duration:

50 seconds.

Results of power up test or reset:

Pass: Fault message is no longer displayed, flight control page auto popup functions normally.
Fail: Fault remains.

Notes:

If any page on the ECAM control panel is manually selected, the auto-function is not operative.

Sign off:

AMM31-50-00-710-002.

Applicable deferrals:

MEL31-63-03=ECAM Memo Display.


NO AIDS PROMPT ON MCDU
Aircraft configuration prior to reset:

Aircraft on ground, engines stopped.

Circuit breakers to reset:

Steps to clear warning:

Open associated breakers for 1 seconds, then reset.

Reset duration:

40 seconds.

Results of power up test or reset:

Pass: AIDS appears on MCDU menu page.


Fail: Fault remains.

Notes:

There is a CFDS power up test bite. “CFDS-INSTRUMENT-DMU”.

Sign off:

AMM31-36-00-710-001

Applicable deferrals:

MEL31-30-07 Data Management Unit (DMU)


PFR PRINTS AUTOMATIC AFTER LANDING
Aircraft configuration prior to reset:

Aircraft on ground.

Circuit breakers to reset:

None.

Steps to clear warning:

Go to MCDU-CFDS, the next page. Select ACARS PRINT/PROGRAM. Then select post flight report PRINT to
NO. Return to CFDS.

Reset duration:

N/A.

Results of power up test or reset:

Pass: PFR wont auto print.


Fail: PFR still auto prints.

Notes:

Sign off:

N/A

Applicable deferrals:

N/A
SDAC 1(2) FAULT
Aircraft configuration prior to reset:

On ground.

Circuit breakers to reset:

Steps to clear warning:

Open associated breakers together for 3 seconds, then reset.

Reset duration:

5 seconds.

Results of power up test or reset:

Pass: SDAC ECAM message clears


Fail: Fault remains.

Notes:

No notes at this time.

Sign off:

AMM31-50-00-710-003

Applicable deferrals:

MEL31-55-01=System Data Concentrator Units.


UNABLE TO SWITCH DISPLAY UNIT (DU)
Aircraft configuration prior to reset:

On ground.

Circuit breakers to reset:

Steps to clear warning:

Open associated breakers for 5 seconds, then reset.

Reset duration:

5 seconds.

Results of power up test or reset:

Pass: Display unit image switches normally.


Fail: Fault remains.

Notes:

No notes at this time.

Sign off:

AMM31-60-00-710-001. (EIS start)

Applicable deferrals:

MEL31-61-01=EIS Switching Systems.


BRAKE SYSTEM 1(2) FAULT
Aircraft configuration prior to reset:

Aircraft on ground, not moving.

Circuit breakers to reset:

Steps to clear warning:

First, select the anti-skid/NWS off, then on. Second open associated circuit breaker for 5 seconds, then close.

Reset duration:

3 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

No notes at this time.

Sign off:

AMM32-46-00-740-001.

Applicable deferrals:

MEL32-42-03=BSCU.
BRAKES GRABBING DURNING TAXI
Aircraft configuration prior to reset:

Aircraft on ground, “NOT MOVING”.

Circuit breakers to reset:

None.

Steps to clear warning:

Reset A/SKID-NWS switch on landing gear control panel. No help, bleed associated brakes.

Reset duration:

N/A.

Results of power up test or reset:

Pass: Control of brakes switch to other BSCU channel.


Fail: Fault remains.

Notes:

Flight crews can perform this with engines running. Just make sure the aircraft is stopped.

Sign off:

AMM32-46-00-740-001

Applicable deferrals:

MEL32-42-03=BSCU.
BSCU CHANNEL 1(2) FAULT
Aircraft configuration prior to reset:

Aircraft on ground, not moving.

Circuit breakers to reset:

Steps to clear warning:

First, select the anti-skid/NWS off, then on. Second open associated circuit breaker for 5 seconds, then close.

Reset duration:

3 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

No notes at this time.

Sign off:

AMM32-46-00-740-001.

Applicable deferrals:

MEL32-42-03=BSCU.
L/G (LANDING GEAR) SYSTEM DISAGREE
Aircraft configuration prior to reset:

Aircraft on ground.

Circuit breakers to reset:

None.

Steps to clear warning:

Check post flight report for faulted gear or door sensor. Or perform a CFDS / LG / LGCIU bite check for current
faults. Check rig and/or replace faulty sensor or target. If main gear uplock disagree is shown on ground, make sure
the main gear uplocks (Hooks) have not been physically tripped.

Reset duration:

N/A.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

Sign off:

AMM32-69-00-740-001

Applicable deferrals:

No MEL
LGCIU 1(2) FAULT
Aircraft configuration prior to reset:

Aircraft on ground.

Circuit breakers to reset:

Steps to clear warning:

Open associated breaker for 1 seconds, then reset.

Reset duration:

2 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

LGCIU #1 drives landing gear panel lights. also remember probes and window heat is driven to full hot when
LGCIU breakers are open.

Sign off:

AMM32-69-00-740-001

Applicable deferrals:

MEL32-31-01=LGCIU
NO BRAKE TEMPS DISPLAYED ON ECAM
Aircraft configuration prior to reset:

Aircraft on ground.

Circuit breakers to reset:

Steps to clear warning:

Open associated breaker for 5 seconds, then reset.

Reset duration:

5 seconds.

Results of power up test or reset:

Pass: Brake temps show on ECAM.


Fail: Fault remains.

Notes:

Take off warning configuration horn will sound when BTMU is on MEL. T/O not allowed with hot brakes. MEL
requires removing cannon plug for affected wheel BTMU. Erroneos indications are extreme HI temps or amber XX.

Sign off:

AMM32-47-00-710-001.

Applicable deferrals:

MEL32-47-01=Brake Temperature Monitoring Unit.


NOSE WHEEL STEERING FAULTY
Aircraft configuration prior to reset:

Aircraft on ground, “NOT MOVING”.

Circuit breakers to reset:

None.

Steps to clear warning:

Reset A/SKID-NWS switch on landing gear control panel. No help, bleed associated brakes.

Reset duration:

N/A.

Results of power up test or reset:

Pass: Control of steering switch to other BSCU CH.


Fail: Fault remains.

Notes:

Flight crews can perform this with engines running. Just make sure the aircraft is stopped.

Sign off:

AMM32-51-00-720-003.

Applicable deferrals:

MEL32-60-04=N/WS Minor Fault Caution on ECAM.


NWS FAULT DURNING FLIGHT CONTROL CK.
Aircraft configuration prior to reset:

Aircraft on ground.

Circuit breakers to reset:

None.

Steps to clear warning:

Determine which NWS disconnect button was pushed durning rudder check. Replace that steering tiller.

Reset duration:

N/A.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

Sign off:

AMM32-51-00-720-007.

Applicable deferrals:

MEL32-51.02=Pedal DISC.
CABIN LIGHTS STUCK IN BRIGHT
Aircraft configuration prior to reset:

None specfic.

Circuit breakers to reset:

Steps to clear warning:

Open associated breaker for 3 seconds, then reset. If no help, reset CIDS or associated DEU thru PTP.

Reset duration:

2 seconds.

Results of power up test or reset:

Pass: Light dims.


Fail: Fault remains.

Notes:

If a couple successive rows of cabin lights won’t dim, associated DEU is failed.

Sign off:

AMM33-21-00-710-001 (lights test).


AMM23-73-00-740-005 (CIDS bite).

Applicable deferrals:

MEL23-73-02=DEU#A.
MEL33-21-01=Cabin Light System.
CABIN LIGHTS WON’T TURN ON
Aircraft configuration prior to reset:

None specfic.

Circuit breakers to reset:

Steps to clear warning:

Open associated breaker for 3 seconds, then reset. If no help, reset CIDS thru PTP or MCDU.

Reset duration:

2 seconds.

Results of power up test or reset:

Pass: Lights turn on.


Fail: Fault remains.

Notes:

If a couple successive rows of cabin lights won’t turn on, associated DEU is failed.

Sign off:

AMM33-21-00-710-001 (lights test).


AMM23-73-00-740-005 (CIDS bite).

Applicable deferrals:

MEL23-73-02=DEU#A.
MEL33-21-01=Cabin Light System.
COCKPIT FLOOR/CONSOLE/BRIEFCASE LIGHTS INOP
Aircraft configuration prior to reset:

Aircraft on ground.

Circuit breakers to reset:

Capt's side = Z05. F/O's side = Z06.

Steps to clear warning:

Check the condition of underseat lights for damage sockets.

Reset duration:

N/A.

Results of power up test or reset:

Pass: Panel lights work normally.


Fail: Panel lights remain inop.

Notes:

Sign off:

AMM33-12-00-710-001.

Applicable deferrals:

MEL33-10-01=Cockpit Lighting System.


EMERGENCY LIGHTS INOP
Aircraft configuration prior to reset:

Aircraft on ground.

Circuit breakers to reset:

Steps to clear warning:

Open associated breaker for 1 seconds, then reset. If multiple lights are inop, perform EPSU test from PTP or
individual EPSU.

Reset duration:

1 seconds.

Results of power up test or reset:

Pass: Lights operates.


Fail: Fault remains.

Notes:

Sign off:

AMM33-51-00-710-001.
Applicable deferrals:

MEL33-50-02=Overhead Emergency Lights.


MEL33-50-03=Floor Path Emergency Lights.
INTEGRAL PANEL LIGHTING INOP
Aircraft configuration prior to reset:

No specific

Circuit breakers to reset:

Check light controllers below for circuit breaker or fuse locations.

Steps to clear warning:

If multiple panel lights are inop, a fuse is blown in the associated light controller. Replace associated fuse, or
controller.

Reset duration:

N/A.

Results of power up test or reset:

Pass: Panel lights work normally.


Fail: Panel lights remain inop.

Controllers:
Sign off:

AMM33-13-00-710-001.

Applicable deferrals:

MEL33-10-01=Instrument Panel Lighting System.


NO LIGHTS IN MLG WHEEL WELL AREAS
Aircraft configuration prior to reset:

None specfic.

Circuit breakers to reset:

Steps to clear warning:

Open associated breaker for 1 seconds, then reset. No help, relamp or tap lens.

Reset duration:

1 seconds.

Results of power up test or reset:

Pass: Lights operates.


Fail: Fault remains.

Notes:

MLG wheel well light bulb P/N#311.

Sign off:

AMM33-37-00-710-001

Applicable deferrals:

MEL33-30-01=Cargo Service Lighting System.


READING LIGHTS INOP
Aircraft configuration prior to reset:

Aircraft on ground, reading lights switch on FAP selected “ON”.

Circuit breakers to reset:

Steps to clear warning:

Open associated breaker for 1 seconds, then reset. If no help, reset CIDS thru PTP or MCDU.

Reset duration:

1 seconds.

Results of power up test or reset:

Pass: Reading lights operate.


Fail: Fault remains.

Notes:

If no help, relamp inop reading light. In no help, replaced PCB fuse, If no help replaced the PCB.

Sign off:

AMM33-25-00-710-001 (lights test).


AMM23-73-00-740-005 (CIDS bite).

Applicable deferrals:

MEL33-20-01=Cabin Lighting System.


STROBE LIGHT WON’T SHUT OFF
Aircraft configuration prior to reset:

None specfic.

Circuit breakers to reset:

Steps to clear warning:

Open breaker to stop strobe lights flashing,replace 12LV relay to fix problem.

Reset duration:

N/A

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

The relay FIN number is 12LV P/N E0246-115B0 M&E-26-2400-3-0159.

Sign off:

AMM33-48-00-710-002.

Applicable deferrals:

MEL33-40-08=Strobe Lights.
ADIRU-FLASHING ALIGN LIGHT AT ALIGNMENT
Aircraft configuration prior to reset:

Aircraft on ground, not moving, (PPOS)-present position entered thru MCDU INIT page.

Circuit breakers to reset:

None.

Steps to clear warning:

Affected ADIRU, turn the rotary knob on ADIRS control panel to ATT for 5 seconds, then to OFF for 20 seconds,
then to NAV. If no help, affected ADIRU needs to cool down. If cool, replace ADIRU.

Reset duration:

600 seconds.

Results of power up test or reset:

Pass: Normal alignment.


Fail: Fault remains.

MCDU:

Sign off:

AMM34-13-00-740-002.

Applicable deferrals:

MEL34-10-01=ADIRS.
ADR OR IR 1(2)(3) FAULT
Aircraft configuration prior to reset:

Aircraft on ground.

Circuit breakers to reset:

Steps to clear warning:


Above breakers are main/backup power for ADIRU's. Try reseting and realinging ADIRU. No help check check
CFDS for faults. To T/S, check the CFDS/NAV/ADR or IR/ T/S DATA. The first 4 digits in the upper left corner is the
fault analysis number. The two middle digits in the fault analysis number is the failure code.

Reset duration:

600 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

A known problem of the ADIRU shelf vibrating and hitting the top of the ADIRU will cause this fault.

Sign off:

AMM34-13-00-740-002.

Applicable deferrals:

MEL34-10-01=ADIRS.
AUTO-TUNE INOP
Aircraft configuration prior to reset:

Aircraft on ground.

Circuit breakers to reset:

None.

Steps to clear warning:

Try a different station position in the MCDU “INIT” page. The nav data could be at fault. Also verify both RMP’s that
the “NAV ON” switch is off-(Plastic Guarded Switch).

Reset duration:

N/A.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

RMP:

Sign off:

AMM.

Applicable deferrals:

MEL34-00-01=Autotune System.
FLIGHT RECORDER PROBLEM
Aircraft configuration prior to reset:

Aircraft on ground, engines stopped.

Circuit breakers to reset:

Steps to clear warning:

Open breaker for 1 seconds, then reset.

Reset duration:

25 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

No notes at this time.

Sign off:

AMM31-33-00-710-006

Applicable deferrals:

MEL31-30-02=Flight Data Recorder (FDR).


GPWS FAULT
Aircraft configuration prior to reset:

Aircraft on ground.

Circuit breakers to reset:

Steps to clear warning:

Open associated breaker for 1 seconds, then reset. No help, move aircraft approx 4 feet.

Reset duration:

25 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

This problem may be by ILS freq’s that are close and interfering with the GPWS system. Move A/C. This fault may
appear and disappear during taxi for this reason.

Sign off:

AMM34-48-00-740-002.

Applicable deferrals:

MEL34-48-01=GPWS/EGPWS.
NAV - GPS 1(2) FAULT ONLY
Aircraft configuration prior to reset:

Aircraft on ground.

Circuit breakers to reset:

Steps to clear warning:

Open associated breaker for 5 seconds, then reset.

Reset duration:

10 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

Check troubleshoot data for “A7” fault code. GPS antenna normally at fault in this situation.

Sign off:

AMM34-36-00-740-003.

Applicable deferrals:

MEL34-58-01=Gobal Positioning System.


NAV - PRED WINDSHEAR DET FAULT
Aircraft configuration prior to reset:

Aircraft on ground.

Circuit breakers to reset:

Steps to clear warning:

Switch radar off, then on from the control panel, if no help open associated breaker for 5 seconds, then reset.

Reset duration:

30 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

Sign off:

AMM34-41-00-740-002 (Weather radar test).

Applicable deferrals:

MEL22-66-03-Windshear Detection.
NAV - TCAS FAULT
Aircraft configuration prior to reset:

No specific.

Circuit breakers to reset:

Steps to clear warning:

Open breaker for 5 seconds, then reset. No help, bite test TCAS computer located on the 82VU rack.

Reset duration:

10 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

Sign off:

AMM34-43-00-740-001.

Applicable deferrals:

MEL34-43-01=TCAS System.
NAV ILS/MMR 1(2)
Aircraft configuration prior to reset:

Aircraft on ground.

Circuit breakers to reset:

Steps to clear warning:

Open associated breaker for 5 seconds, then reset. If no help, check MMR in fwd E&E for fault light.

Reset duration:

10 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

MMR is normally the cause of this fault.

Sign off:

AMM34-36-00-740-003.

Applicable deferrals:

MEL34-58-01=Gobal Positioning System.


MEL34-36-01=ILS #2 System
NAV-RA 1(2) INOP
Aircraft configuration prior to reset:

Aircraft on ground.

Circuit breakers to reset:

Steps to clear warning:

Open associated breaker for 20 seconds, then reset. If no help, perform a CFDS/NAV/RA/ARINC test.

Reset duration:

30 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

Sign off:

AMM34-42-00-740-002.

Applicable deferrals:

MEL34-42-01=Radio Altimeter System.


WHITE “GPS PRIMARY” MESSAGE SHOWN
Aircraft configuration prior to reset:

Aircraft on ground.

Circuit breakers to reset:

None.

Steps to clear warning:

“GPS PRIMARY” message is normal operartion. This is stating the the GPS is the primary mode of operation. The
clear button on the MCDU will erase this message.

Reset duration:

N/A.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

MCDU:

Sign off:

AMM34-36-00-740-003.

Applicable deferrals:

MEL34-58-01=Gobal Positioning System.


WINDSHEAR DET FAULT
Aircraft configuration prior to reset:

Aircraft on ground, engines can be running, flaps up.

Circuit breakers to reset:

Steps to clear warning:

First reset FAC’S from overhead pushbuttons. Then open associated breaker for 10 seconds, then reset.

Reset duration:

90 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

If hydraulics are powered, reset duration is less than 10 seconds, 90 seconds otherwise. Also message may occur
spuriously on ground.

Sign off:

AMM22-60-00-710-004 (FAC ops test).


AMM34-41-00-740-002 (Weather radar test).

Applicable deferrals:

MEL22-66-03-Windshear Detection.
CREW OXYGEN LOW PRESSURE MESSAGE
Aircraft configuration prior to reset:

Aircraft on ground.

Circuit breakers to reset:

None.

Steps to clear warning:

Verify crew oxygen pushbutton swich is selected “ON”. If no help, make sure the crew oxygen bottle valve is
turned on. The bottle is in the FWD left equipment bay.

Reset duration:

N/A.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Overhead Panel:

Sign off:

TSM35-10-00-810-820.

Applicable deferrals:

MEL35-13-01=ECAM Page Indications.


AIR BLEED - LEFT WING LEAK/LOOP MESSAGE
Aircraft configuration prior to reset:

Aircraft on ground, packs running, engines off.

Circuit breakers to reset:

Steps to clear warning:

Reset affected bleed pushbutton first, no help open associated breakers for 1 second, then reset.

Reset duration:

25 seconds.

Results of power up test or reset:

Pass: Message disappears.


Fail: Message remains. Check BMC for faults.

Notes:

Fault means high temp(or bleed leak) sensed by one of two loops. Can be generated in hot station, then clear in
cool station due to poor loop installation,(factory problem).

Sign off:

AMM36-11-00-740-001 (BMC TEST).

Applicable deferrals:

MEL36-00=Class 2 Maintenance Messages only


AIR BLEED - RIGHT WING LEAK/LOOP MESSAGE
Aircraft configuration prior to reset:

Aircraft on ground, packs running, engines off.

Circuit breakers to reset:

Steps to clear warning:

Reset affected bleed pushbutton first, no help open associated breakers for 1 second, then reset.

Reset duration:

25 seconds.

Results of power up test or reset:

Pass: Message disappears.


Fail: Message remains. Check BMC for faults.

Notes:

Fault means high temp(or bleed leak) sensed by one of two loops. Can be generated in hot station, then clear in
cool station due to poor loop installation,(factory problem).

Sign off:

AMM36-11-00-740-001 (BMC TEST).

Applicable deferrals:

MEL36-00=Class 2 Maintenance Messages only


BMC PROBLEMS
Aircraft configuration prior to reset:

Aircraft on ground, engines off.

Circuit breakers to reset:

Steps to clear warning:

Open associated breaker for 1 second, then reset.

Reset duration:

25 seconds.

Results of power up test or reset:

Pass: Message disappears.


Fail: Message remains. Check BMC for faults.

Notes:

No notes at this time.

Sign off:

AMM36-11-00-740-001 (BMC TEST).

Applicable deferrals:

MEL36-11-01=Bleed Air Systems.


CLASS 2 AIR BLEED MESSAGE
Aircraft configuration prior to reset:

Aircraft on ground, emergency electrical generator test recently performed.

Circuit breakers to reset:

Steps to clear warning:

Open both FWC breaker for 5 seconds, then reset. If no help reset both BMC’s (D11,D12,Z22,Z23) and FWC
breakers again. If no help check BMC for faults.

Reset duration:

90 seconds, triple click.

Results of power up test or reset:

Pass: Message disappears.


Fail: Message remains. Check BMC for faults.

Notes:

This fault is latched after Emergency Generator test.

Sign off:

AMM36-11-00-740-001 (BMC TEST).

Applicable deferrals:

MEL36-00=Class 2 Maintenance MSG on ECAM.


CROSS BLEED VALVE FAULTS
Aircraft configuration prior to reset:

Aircraft on ground. Packs off.

Circuit breakers to reset:

Steps to clear warning:

Open associated circuit breaker for 1 second, then reset.

Reset duration:

5 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

No notes at this time.

Sign off:

AMM36-12-00-710-001 (Crossbleed Valve Ops Test).

Applicable deferrals:

MEL36-12-04=Cross Bleed Valve


NO WATER PRESSURE
Aircraft configuration prior to reset:

Aircraft on ground. water service panel door closed, apu bleed on.

Circuit breakers to reset:

None.

Steps to clear warning:

Check fwd flight attendant panel. Verify WTR SYSTEM DEPRESS pushbutton is not illuminated.

Reset duration:

30 seconds.

Results of power up test or reset:

Pass: Water pressure is normal.


Fail: No water pressure.

Notes:

Verify the water servicing access door is closed and servicing valve is also closed. Not all aircraft have the “WTR
SYST DEPRES” button installed on FWD FAP.

Sign off:

TSM38-41-00-810-801.

Applicable deferrals:

MEL38-10-01=Potable Water Systems.


TOILET’S WON’T FLUSH
Aircraft configuration prior to reset:

Aircraft on ground, lav service panel door is closed and the waste tank is not full, depressurization valve light off-(if
installed).

Circuit breakers to reset:

Steps to clear warning:

Open breaker for 1 seconds, then reset.

Reset duration:

5 seconds.

Results of power up test or reset:

Pass: Lav’s flush normally


Fail: Lav’s won’t flush.

Notes:

CIDS fault light also displayed, troubleshoot thru CIDS. There is also a Toilets page in the CFDS(page #2) via the
MCDU. If Vacuum Generator is inop, toilets will still flush in flight above FL180.

Sign off:

AMM38-31-00-710-002.

Applicable deferrals:

MEL38-30-01=Lavatory Waste Systems.


ATSU IS LOCKED UP ON THE MCDU
Aircraft configuration prior to reset:

Aircraft on ground.

Circuit breakers to reset:

Steps to clear warning:

Open associated breakers for 3 seconds, then close. If this does not work pull and reset these circuit breakers
(49VU-MCDU#1/B01)+(49VU SDAC#1/F04)+(49VU FWC#1/F01)+(121VU CFDIU/J18) (121VU VHF#3/L05)+(121VU
MCDU#2/N20)+(121VU FWC#2/Q07)

Reset duration:

Approx. 2 minutes.

Results of power up test or reset:

Pass: ATSU selectable.


Fail: ATSU not selectable.

Notes:

Here you go Lukas!.

Sign off:

AMM46-21-00-740-001.

Applicable deferrals:

MEL23-24-01=ACARS.
MEL46-21-01=ATSU.
TROUBLE LOADING ATSU SOFTWARE
Aircraft configuration prior to reset:

Aircraft on ground.

Circuit breakers to reset:

None.

Steps to clear warning:

After loading 20TX, must disconnect loader for 3 minutes prior to loading 22TX, and again prior to loading 24TX.

Reset duration:

N/A.

Results of power up test or reset:

Pass: Software loads.


Fail: Software will not load.

Notes:

Must load ATSU in order, 20TX, 22TX, 24TX. Adhere to manual loading procedure.

Sign off:

AMM46-21-00-740-001.

Applicable deferrals:

MEL23-24-01=ACARS.
MEL46-21-01=ATSU.
Honeywell 131-9(A) APU T/S DATA

No Start "Auto Shutdown" Message:

(No Acceleration) Reason-Apu Speed < %7 for 30 seconds.

o Action #1 = Restart with both A/C battery switches "ON" prior to master switch "ON".
o Action #2 = Verify APU rotates freely, if so R/R starter motor(8KA).
o Action #3 = If APU does not rotate freely (independent of the starter motor) R/R APU.
o General info = If A/C batteries are selected "ON" after the master switch is selected "ON", possible no acceleration
auto shutdown can occour, restart with A/C batteries "ON" first.

(No Acceleration) Reason-Accel < 0.1-0.5% for 15-60 seconds.

o Action #1 = Verify APU rotates freely. If so bleed the fuel line and perform a restart.
o Action #2 = If the auto shut down continues, R/R starter motor(8KA).
o Action #3 = If the auto shut down continues, R/R the Fuel Control Unit.
o General info = Subsequent "No Flame" and "Underspeed" auto shut downs can occur if no T/S action is taken.
o CAUTION: LIMIT APU STARTS TO 3/HR, OTHERWISE STARTER MOTOR DAMAGE CAN OCCUR.

No Flame.

o Action #1 = Bleed the fuel line and preform a restart.


o Action #2 = If the auto shut down continues R/R Ignition Exciter(P10).
o General info = Subsequent "No Flame" and "Underspeed" auto shut downs can occur if no T/S action is taken.
o CAUTION: LIMIT APU STARTS TO 3/HR, OTHERWISE STARTER MOTOR DAMAGE CAN OCCUR.

On Speed "Auto Shutdown" Message:

Emergency.

o Action #1 = Inspect 108VU panel for water ingestion and contamination of "APU EMERGENCY SHUT DOWN" button
(1KL). R/R 108VU panel per AIRBUS SB A320-92-1011.

Clogged Oil Filter.

o Action #1 = Inspect mag plug for metal contamination R/R lube and generator filter elements.
o Action #2 = If auto shut down continues, R/R both differential pressure switches.
o Action #3 = If metal contanimation found on mag plug and auto shut down continues, R/R APU.
o General info = Oil brand changes have been linked to filter clogging auto shutdowns. (no adverse inpact to APU).

Overtemperature (High temp onspeed or high temp on droop)

o Action #1 = Most Overtemp auto shut downs are due to E/C-(engine cooling) shroud delamination failures.
o Action #2 = If shroud is delamed, replace the shroud.
o Action #3 = If shroud is ok and auto shut downs continue, R/R APU.

Low Fuel Pressure.

o Action #1 = If the fault is in conjunction with an auto shut down(No Flame/No Acceleration/or Underspeed) see ASD
T/S recommendations above.
o Action #2 = If the fault continues however the APU still starts, R/R A/C Fuel Pressure Switch(5030QM).
o Action #3 = If the fault continues, check for possible defects with the A/C Fuel Pressure Switch (7QC). APU Fuel
Pump, or Air Release Valve.
o CAUTION: LIMIT APU STARTS TO 3/HR, OTHERWISE STARTER MOTOR DAMAGE CAN OCCURe
o
No, Low, or Fluctuating Bleed Air Pressure:

No Air.
o Action #1 = If no APU LRU faults are found in the CFDS, restart APU and verify bleed air operations in ECS 2-Pack
mode.
o Action #2 = If NO AIR continues, R/R A/C Bleed Switch.
o General info = Most "NO AIR" defects should have a Faulted LRU observed in the CFDS last leg reports.

FCN(Fault Code Number) = TSM Task.

(007, 008, 009, 010)=TSM49-70-00-810-816.

(016, 017, 018, 019)=TSM49-00-81-810-853.

(026, 027, 028, 029)=TSM49-00-81-810-854.

(031)=TSM49-00-81-810-852.

(076, 077, 215)=TSM49-00-81-810-835.

(079)=TSM49-00-81-810-802/806/813/824/836.

(081, 082)=TSM49-00-81-810-858.

(083)=TSM49-00-81-810-811/840.

(088, 096, 097)=TSM49-00-81-810-861.

(089, 091)=TSM49-00-81-810-856.

(099, 245)=TSM49-00-81-810-818/820/867.

(100)=TSM49-00-81-810-808/822/839.

(102)=TSM49-00-81-810-849.

(105, 106, 107)=TSM49-00-81-810-807/823/857.

(109, 110)=TSM49-00-81-810-851.

(113, 114)=TSM49-00-81-810-834.

(120)=TSM49-00-81-810-832.

(123)=TSM49-00-81-810-831.

(128, 146)=TSM49-00-81-810-825.

(204)=TSM49-00-81-810-805.

(205)=TSM49-00-81-810-810.

(206)=TSM49-00-81-810-812.

(208)=TSM49-00-81-810-819.

(209)=TSM49-00-81-810-821.

(211)=TSM49-00-81-810-829.

(212)=TSM49-00-81-810-830.

(215)=TSM49-00-81-810-835.

(216)=TSM49-00-81-810-847.

(218)=TSM49-00-81-810-850.
(240, 241, 242, 243, 244)=TSM49-00-81-810-821.
APU BLEED FAULTS
Aircraft configuration prior to reset:

No specific.

Circuit breakers to reset:

Steps to clear warning:

Shut down APU. Open above circuit breakers for 3 seconds, then reset.

Reset duration:

30 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

No notes at this time.

Sign off:

TSM36-12-00-810-801.
AMM49-00-00-710-001 (ECB self test).

Applicable deferrals:

MEL36-12-01=APU Bleed Air System.


APU ELECTRICS, NO VOLTS OR FREQS
Aircraft configuration prior to reset:

Aircraft on ground, engines stopped.

Circuit breakers to reset:

Steps to clear warning:

Select APU ELEC OFF and reset back to ON. If no help, reset above circuit breaker.

Reset duration:

30 mirco-seconds

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

No notes at this time.

Sign off:

AMM24-41-00-740-002 (GPCU test).

Applicable deferrals:

MEL24-20-02=APU Generator Channel.


APU WILL NOT START
Aircraft configuration prior to reset:

Aircraft on ground.

Circuit breakers to reset:

None.

Steps to clear warning:

Verifey both batteries are on, “FLAP OPEN” is displayed on APU page after APU master switch is selected.

Reset duration:

N/A.

Results of power up test or reset:

Pass: APU Starts.


Fail: APU will not start.

Notes:

If APU still wont start, check CFDS/APU/T-S DATA.

Sign off:

AMM49-00-00-710-008.

Applicable deferrals:

MEL49-10-01=APU System.
CABIN DOOR PRESSURE LIGHT FLASHING
Aircraft configuration prior to reset:

Aircraft on ground, engines shut down, door disarmed, no risidual cabin pressure on board.

Circuit breakers to reset:

Steps to clear warning:

Try reseting above circuit breaker, if no help T/S by removing the connector from the 14WN pressure switch in
FWD E&E. If light extingishes change switch.

Reset duration:

5 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

Light normally flashes when both engines are shut down, the associated slide is disarmed and cabin pressure is
greater then .036 PSI.

Sign off:

TSM52-73-00-810-801.

Applicable deferrals:

MEL52-70-02=Cabin Pressure Light On Door.


COCKPIT DOOR FAULT
Aircraft configuration prior to reset:

Aircraft on ground.

Circuit breakers to reset:

Steps to clear warning:

Open associated circuit breakers for 5 seconds, then reset. If no help, check for faults on the overhead door
controller.

Reset duration:

5 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

Overhead door controller.

Sign off:

AMM52-51-00-710-001.

Applicable deferrals:

MEL52-50-01=Door Lock Solenoid.


MEL52-50-02=Door Locking System.
HYD PUMP DOESN’T STOP WITH CARGO DOOR OPS.
Aircraft configuration prior to reset:

Aircraft on ground.

Circuit breakers to reset:

Steps to clear warning:

Open above circuit breaker for 5 seconds, then reset If no help check the LGCIU for faults. (Could be the time
delay relay 6MJ).

Reset duration:

5 seconds.

Results of power up test or reset:

Pass: Fault clears.


Fail: Fault remains.

Notes:

No notes at this time.

Sign off:

AMM52-30-00-860-001.

Applicable deferrals:

MEL52-30-04=Cargo Door Elec. Opening System.


ENGINE 1(2) EGT OVERLIMIT
Aircraft configuration prior to reset:

No specific

Circuit breakers to reset:

None.

Steps to clear warning:

Read the specific data report from the MCDU=(CFDS/INST/EIS1/XLOAD(optional)/ENGINE).

Reset duration:

N/A.

Results of power up test or reset:

Pass: N/A.
Fail: N/A.

Notes:

If the valve of one of these parameters is higher than the max limit, the report also shows how long (in seconds)
the associated parameter was at that limit. If no overlimit condition occured, there is no time indication.

Check history, if more than 5 hits within the first 25 cycles of the first hit, the exceedance condition must be
idenified.

You can reset these values if necessary. Push the line key adjacent to the “RESET MAX VALUES” then
“CONFIRM RESET” indications.

Sign off:

CFM=TSM73-00-00-810-849, AMM72-00-00-200-008.

V2500=TSM73-22-00-810-861, AMM71-00-00-710-014.

Applicable deferrals:

No MEL.
ENGINE 1(2) EIU FAULT
Aircraft configuration prior to reset:

Aircraft on ground, engines stopped.

Circuit breakers to reset:

Steps to clear warning:

Open associated breaker for 1 second, then reset. If you have dual EIU faults, perform a FADEC (A/B) bite, then
select start cycle rotary switch from norm to crank, wait 14 seconds and return to norm, wait 5 min, then pull ENG 1/2
oil pressure CB, reset after 5 seconds

Reset duration:

2 seconds.

Results of power up test or reset:

Pass: Fault Clears


Fail: Fault remains.

Notes:

No notes at this time.

Sign off:

AMM73-29-00-710-040.

Applicable deferrals:

No MEL.
ENGINE 1(2) EIU MAINTENANCE STATUS
Aircraft configuration prior to reset:

Aircraft on ground, engines stopped.

Circuit breakers to reset:

Steps to clear warning:

Open associated breaker for 1 second, then reset.If no help, perform FADEC (A/B) bite test.

Reset duration:

2 seconds.

Results of power up test or reset:

Pass: Fault Clears


Fail: Fault remains.

Notes:

If associated with fault message check 17(16)HB circuitry or EIU 1(2), can be caused by failed flow control valve or
relay 16HB(17HB), pack closure relay.

Sign off:

AMM73-29-00-710-040.

Applicable deferrals:

MEL71-00=Class 2 Message.
ENGINE 1(2) EPR MODE FAULT MESSAGE
Aircraft configuration prior to reset:

No specific

Circuit breakers to reset:

None.

Steps to clear warning:

Recovery of EPR on both engines may be attemped by switching off each engine’s N1 mode switch.

Reset duration:

N/A.

Results of power up test or reset:

Pass: N/A.
Fail: N/A.

Notes:

If EPR was fluctuating, check PFR for associated failures.P2/T2 or P5 failures = check associated lines for leaks.

Sign off:

AMM73-22-00-710-040.

Applicable deferrals:

No MEL.
ENGINE 1(2) FADEC A(B) CHANNEL FAULT
Aircraft configuration prior to reset:

Aircraft on ground, engines stopped.

Circuit breakers to reset:

Steps to clear warning:

Select ECU’s off, then on using pushbuttons. If no help, open associated breaker for 1 second, then reset.

Reset duration:

2 seconds.

Results of power up test or reset:

Pass: Fault Clears


Fail: Fault remains.

Notes:

No notes at this time.

Sign off:

AMM73-29-00-710-040.

Applicable deferrals:

No MEL.
ENGINE 1(2) FADEC FAULT
Aircraft configuration prior to reset:

Aircraft on ground, engines stopped, ECU’s powered.

Circuit breakers to reset:

Steps to clear warning:

Select ECU’s off, then on using pushbuttons. If no help, open associated breaker for 1 second, then reset.

Reset duration:

2 seconds.

Results of power up test or reset:

Pass: Fault Clears


Fail: Fault remains.

Notes:

HPTCC VLV(POS), HMU or TCC faults not confirmed on FADEC test are spurious.

Sign off:

AMM73-29-00-710-040.

Applicable deferrals:

NO MEL.
ENGINE 1(2) OVERSPEED PROTECTION FAULT V2500
Aircraft configuration prior to reset:

Overspeed Protection Fault identified by FMU/HC/EEC1/2 on PFR with fault code "OSFFMU".

Circuit breakers to reset:

None.

Steps to clear warning:

Read the FADEC fault codes shown in the FLIGHT DATA and GROUND DATA sections. If you have fault
code "OSFFMU" attempt to clear the overspeed protection fault as follow's. All other fault codes trouble shoot iaw
TSM.

1. On the 50VU, push the ENG FADEC GRD PWR pushbutton switch and release it again. (Resets FADEC)

2. Push INT mode key on the MCDU and enter a new flight number.

3. Start the engine and run at idle for 4 minutes with engine generator on, then turnoff associated engine generator for
1 minute.

4. Shutdown the engine, and if there are no ECAM/PFR faults, return to service.

5. If fault code OSFFMU continues, repeat above steps, If fault still wont clear, check "B" and "C" contectors (Pins J/H)
on FMU. Also check "J5" and "J11" contectors (Pins J/d) at EEC. Check TSM for torque motor resistance valves.
Reset duration:

N/A.

Results of power up test or reset:

Pass: Return to service.


Fail: Repeat above steps until cleared.

Notes:

There is no limit to the number of times you may perform this procedure, and can be performed by the crew after
pushback without delaying the flight as long as the ecam message clears.

Sign off:

Supplement to TSM73-22-00-810-851.
Applicable deferrals:
No MEL.
ENGINE 1(2) OVERSPEED
Aircraft configuration prior to reset:

No specific

Circuit breakers to reset:

None.

Steps to clear warning:

Read the specific data report from the MCDU=(CFDS/INST/EIS1/XLOAD(optional)/ENGINE).

Reset duration:

N/A.

Results of power up test or reset:

Pass: N/A.
Fail: N/A.

Notes:

If the valve of one of these parameters is higher than the max limit, the report also shows how long (in seconds)
the associated parameter was at that limit. If no overlimit condition occured, there is no time indication.

CFM=N1 speed >104 and N2 speed >105 will require inspections. T/S per TSM

V2500=N1/N2=100% 5465RPM/14,915RPM will require inspections.

You can reset these values if necessary. Push the line key adjacent to the “RESET MAX VALUES” then
“CONFIRM RESET” indications.

Sign off:

CFM=TSM73-00-00-810-850.
V2500=AMM71-00-00-860-010.

Applicable deferrals:

No MEL.
THRUST REV FAULT AT ENGINE SHUTDOWN
Aircraft configuration prior to reset:

No specific

Circuit breakers to reset:

None.

Steps to clear warning:

Warning will clear on its own within 5 minutes.

Reset duration:

N/A.

Results of power up test or reset:

Pass: N/A.
Fail: N/A.

Notes:

No troubleshooting required if warning is generated at engine shutdown.

Sign off:

CFM=AMM78-31-00-710-042.
V2500=AMM78-31-00-710-042.

Applicable deferrals:

MEL78-30-01=Thrust Reverser Systems.


THRUST REV FAULT AT ENGINE START
Aircraft configuration prior to reset:

Aircraft on ground.

Circuit breakers to reset:

None.

Steps to clear warning:

Shut down engine. Put engine mode select switch to IGN, wait 15 seconds, then back to norm. If no faults, start
engines.

Reset duration:

N/A.

Results of power up test or reset:

Pass: N/A.
Fail: N/A.

Notes:

To prevent fault, select FADEC’s on from the 50VU maintenance panel prior to mode select switch to IGN.

Sign off:

CFM=AMM78-31-00-710-042.
V2500=AMM78-31-00-710-042.

Applicable deferrals:

MEL78-30-01=Thrust Reverser Systems.


THRUST REV TEST THRU MCDU WON’T PASS
Aircraft configuration prior to reset:

Aircraft on ground.

Circuit breakers to reset:

None.

Steps to clear warning:

Test thrust reversers with engines running.

Reset duration:

N/A.

Results of power up test or reset:

Pass: N/A.
Fail: N/A.

Notes:

See TSM 78-00-00-810-802, Thurst reverser test without CFDS, Engines running.

Sign off:

AMM78-31-00-710-04301. (Test with engines running)

Applicable deferrals:

MEL78-30-01=Thrust Reverser Systems.


ENGINE 1(2) OIL FILTER CLOG MESSAGE
Aircraft configuration prior to reset:

No specific

Circuit breakers to reset:

None.

Steps to clear warning:

First select FADEC’s on then off to reset memory. Check the master chip detector and scavage filters for
contamination. Then run engine at idle making sure the oil firlter clog message doesn’t appear. Recheck chip detector
and filter again.

Reset duration:

N/A.

Results of power up test or reset:

Pass: N/A.
Fail: N/A.

Notes:

This message could appear momentarily if OAT is below freezing.

Sign off:

CFM=TSM79-00-00-810-820.
V2500=TSM79-30-00-810-803.

Applicable deferrals:

MEL79-35-01=Engine Oli Filter Clog Message.

You might also like