Specification sheet

VEGAPULS 65
4 … 20 mA/HART - four-wire
Radar sensor for continuous level measurement of liquids
Technical data

Measuring range up to 35 m (114.8 ft)


Deviation ±8 mm
Process fitting Thread from G1½; 1½ NPT; flanges from
DN 40, 1½"
Process pressure -1 … +16 bar/-100 … +1600 kPa
(-14.5 … +232 psig)
Process temperature -40 … +150 °C (-40 … +302 °F)
Ambient, storage and -40 … +70 °C (-40 … +158 °F)
transport temperature
Operating voltage
ƲƲ Version for low voltage 9.6 … 48 V DC, 20 … 42 V AC, 50/60 Hz
ƲƲ Version for mains volt- 90 … 253 V AC, 50/60 Hz
age
SIL qualification Optionally up to SIL2
Application area

The VEGAPULS 65 is a radar sensor for continuous measurement of Materials


liquids under simple process conditions. It is particularly suitable for The wetted parts of the instrument are made of PVDF, 316L or PTFE.
level measurement in vessels with small process fittings and under sim- The process seal is made of FKM.
ple process conditions. The slim rod antenna enables the installation in You will find a complete overview of the available materials and seals in
small vessel openings. the "Configurator" at www.vega.com and "VEGA Tools".

Your benefit Housing versions


• Maintenance-free operation thanks to non-contact measuring princi- The housings are available as double chamber version in plastic, stain-
ple less steel or Aluminium. They are available in protection class IP 66/
• High plant availability, because wear and maintenance free IP 67.
• Exact measuring results independent of process conditions
Electronics versions
Function The instruments are available in different electronics versions.
Apart from 4 … 20 mA/HART in two and four-wire version, there are
Extremely short microwave pulses are emitted by the antenna system in
also digital versions with Profibus PA, Foundation Fieldbus and Modbus
the direction of the measured product, reflected by the product surface
protocols. Another HART version is available with integrated accumula-
and received back again by the antenna system. The time from emis-
tor.
sion to reception of the signals is proportional to the level in the vessel.
A special time stretching procedure allows reliable and precise meas-
urement of the extremely short signal running times. Approvals

The instruments are suitable for use in hazardous areas and are ap-
proved e.g. according to ATEX and IEC. The instruments also have
various ship approvals such as e.g. GL, LRS or ABS.
You can find detailed information at www.vega.com/downloads and
"Approvals".

VEGA Grieshaber KG, Am Hohenstein 113, 77761 Schiltach/Germany, www.vega.com VEGAPULS 65 - 34509-EN-160119
Specification sheet

Operation Dimensions

The adjustment of the instrument is carried out via the optional display
and adjustment module PLICSCOM or via a PC with the adjustment
software PACTware and corresponding DTM.
Further adjustment options are possible via a HART Communicator as
well as manufacturer-specific programs such as AMS™ or PDM.

SW 50 mm

41 mm
(1.61")
(1.97")

94 mm (3.7")
2 mm (0.08")
G1½ A

82 mm (3.23")
(0.87")
22 mm
ø 40 mm
(1.58")
ø 33 mm
(1.3")

270 mm (10.63")
120 mm (4.72")
352 mm (13.86")
ø 33 mm
(1.3")

395 mm (15.55")
545 mm (21.46")
1

Dimensions VEGAPULS 65
1 Threaded version G1½
2 Flange version DN 80

Information

You can find further information about the VEGA product line on www.
vega.com.
In the download section at www.vega.com/downloads you'll find operat-
Electrical connection
ing instructions, product information, brochures, approval documents,
instrument drawings and much, much more.
There, you will also find GSD and EDD files for Profibus PA systems as
4...20mA well as DD and CFF files for Foundation Fieldbus systems.
common

IS GND
passive
active

Instrument selection
power supply

With the "Finder" at www.vega.com/finder and "VEGA Tools" you can


(+)1 2(-) 5 6 7 8 select the most suitable measuring principle for your application.
/L You can find detailed information on the instrument versions in the
/N
PE "Configurator" at www.vega.com/configurator and "VEGA Tools".

Connection compartment with double chamber housing - mains voltage


Contact

You can find the VEGA agency serving your area on our homepage
4...20mA www.vega.com.
common

IS GND
passive
active

power supply

(+)1 2(-) 5 6 7 8
/L
/N

Connection compartment with double chamber housing - low voltage


You can find details on electrical connection in the instrument operating
instructions at www.vega.com/downloads.

VEGAPULS 65 - 34509-EN-160119 VEGA Grieshaber KG, Am Hohenstein 113, 77761 Schiltach/Germany, www.vega.com