Q8-USB - Quick Start Guide
Q8-USB - Quick Start Guide
3 4 5 Mix and match components and peripherals to suit your education or research needs
qu
Ra
an
e
se
im
r.c
l-T
om
ea
CR
for
RESOURCES DVD
info
QPID QPIDe Q2-USB Q8-USB NI Terminal Board
QU
rma
TO SET UP QUANSER WORKSTATIONS
Use
tion.
For use with
On this DVD:
ua
Ra
ns
e
er
im
.co
l-T
m
ea
info
AR
rma
tion
For MATLAB®/Simulink®
R2011a,b and R2012a,b
For installation procedure please
©2
013 om
Qua er.c
nser ans
Inc. All w.qu
rights reserved. ww
A. Make sure you have all required software, as listed in the QUARC Compatibility Table document located in the QUARC DVD folder.
B. See the QUARC Installation Manual for details on how to install the software.
C. Make sure you test the system using the Sine and Scope demo. You can access this by typing qc_show_demos in the Matlab prompt.
STEP 4 Install Data Acquisition Device
The installation procedure for the Q8-USB is shown below. See the User Manual ( enclosed with shipment) for more information.
A Confirm that the software components B Make sure your computer is powered ON
listed in Step 3 have been installed. and you are logged on.
C
Using the USB 2.0 cable, connect
Encoders Analog Outputs
SIGNAL GND
Q8-USB
8 CHANNEL USB DATA ACQUISITON BOARD
WWW.QUANSER.COM
MADE IN CANADA
Analog Inputs
SIGNAL GND
the USB connector on the Q8-USB
data acquisition (DAQ) device to a
3 7
3 7 3 7
2 6 2 6 2 6
1 5 1 5 1 5
0 4
0 4 0 4
C Using the power supply and power cable, connect the power connector on the Q8-USB data
acquisition (DAQ) device to a wall outlet.
Important: Make sure you use the 14-16V power supply that was supplied with the Q8-USB
(Should be rated bwtween 14-16V and at least 1A).
D
Windows1 should automatically
detect the presence of the Q8-USB
and attempt to install the driver.
F
Encoders Analog Outputs
Q8-USB
8 CHANNEL USB DATA ACQUISITON BOARD
WWW.QUANSER.COM
MADE IN CANADA
Analog Inputs
Using the RCA to RCA cable, connect
3 7
SIGNAL GND SIGNAL GND
2 6 2 6 2 6
1
Windows is a registered trademark of Microsoft Corporation in the United States and other countries.
STEP 5 Running the DAQ Test
Go through the procedure below to test your Q8-USB and make sure it is working properly.
A Make sure your PC is powered ON and that you connected the RCA to RCA cable.
C Double-click on
the QUARC HIL
D In the Board type option
list under the Main tab,
Initialize block. select the data acquisition
device that is installed on
the computer (e.g., q8_usb).
I J
When manually moving the Analog Click on the Simulink
Output Signal Knob of the VI, both Stop button to stop
Analog Input and Analog Output the running model
scopes should display the same trace.
If not, go to the Troubleshooting section.
TROUBLESHOOTING Review the following recommenations before contacting Quanser’s technical support engineers
Obtaining this error: A. Verify that you selected the Quanser Q8-USB board in HIL Initialize in the Q8-USB Test.
An operating system B. Make sure the correct USB 2.0 cable from the Quanser Q8-USB board to an
specific kernel-level operational and enable USB 2.0 port connector on the computer is connected.
driver for the specified
C. Make sure the USB board has been powered.
card could not be
found. The card or D. Verify that the Q8-USB-A and Q8-USB-B devices show up in Device Manager under
driver may not be the Universal Serial Bus controllers item. If not, make sure the software listed in
installed. Step 3 is installed.
When performing
the Q8-USB Test, A. Make sure you made the RCA to RCA loopback cable connection on the terminal
the Analog Input board, as described in connection Step 4F.
Scope do not read B. Verify that you selected the Quanser Q8-USB device in HIL Initialize in the Q8-USB Test.
anything.