Instruction Manual
Model No RT500
Salus RT500 Manual 006_89 24/07/2013 10:27 Page 2
PRODUCT COMPLIANCE
This product complies with the essential requirements of the
following EC Directives:
• Electro-Magnetic Compatibility directive 2004/108/EC
• Low Voltage Directive 2006/95/EEC
• EC Marking directive 93/68/EEC
SAFETY INFORMATION
These instructions are applicable to the SALUS Controls model
stated on the front cover of this manual only, and must not be used
with any other make or model.
Please leave these instructions with the end user where they should
be kept in a safe place for future reference.
INTRODUCTION
The RT500 from SALUS Controls is a stylish and accurate 5/2 or 7 day
programmable electronic thermostat with a large, easy to read Liquid
Crystal Display (LCD). This programmable thermostat has been specifically
designed to be used Volt Free.
Features
• 5/2 or 7 day programming flexibility
• Built-in start up programming
for quick installation
• Volt free contacts
• Frost protection
• Large, easy to read LCD
with blue backlight
• Burner on symbol
• User friendly
• Stylish casing
INSTALLATION
Please read the important safety information at the start of this manual
before you begin to install the thermostat.
The ideal position to locate the RT500 thermostat is about 1.5m above floor
level, in a location where the thermostat is accessible, reasonably lit and
free from extremes of temperature and draughts. Do not mount the
thermostat on an outside wall, above a radiator or in a location where it
may be subjected to direct sunlight.
The electrical connections to the RT500 are made to the supplied industry
standard backplate. This simplifies installation, as no connections are made
to the controller itself. Connection details are shown below - no Earth
connection is required for the correct and safe operation of the RT500, but
a parking terminal is provided to connect an Earth wire if one is present.
Backplate Connections
The RT500 requires two ‘AA’ alkaline batteries to function correctly. Ensure that
the batteries are inserted correctly, paying careful attention to the polarity
markings on the battery and next to the battery holders.
Do not restore the mains supply to the system until all associated items are fully
installed.
JUMPER SETTINGS
Changes to the jumper settings should only be made by the Engineer
carrying out the installation or other qualified person.
The installer should select the jumper position required if changes need to
be made to the factory default settings. These jumpers are found on the
rear of the thermostat.
AFTER INSTALLATION
After completing installation and powering up the RT500 for the first time
the thermostat will behave in the following way:
All the indicators on the display and the backlight will be turned on for two
seconds. After two seconds, the RT500 will then operate in Normal mode
(Normal mode is when the thermostat is displaying the room temperature).
The following table shows the settings of the RT500 digital thermostat after
Power on:
This display allows the user a clear indication of the current room
temperature, and the status of the heating system.
There are few user controls for the RT500, making this thermostat
very easy to operate. These controls are shown below, along with a
description of each of their functions.
OPERATION
The RT500 is configured and adjusted
by the use of a minimal number of user
controls, and an intuitive user interface.
The Time and Day are displayed along with a SET indicator, with all other
indicators cleared from the display. The hour part of the time is flashing to
indicate that it is the currently selected item and is ready to be adjusted.
• Press the SELECT key to select the ‘minutes’ section of the time. Set the
minutes in the same way as the hour by using the UP and DOWN keys.
• Press SELECT again to select the Day, and again change the setting with
the UP and DOWN keys.
• Press the SET key to confirm the new time and day settings. This will store
the changes and return the RT500 to Normal mode.
The RT500 will also return to Normal mode (and save the clock settings)
if no keys are pressed for more than 15 seconds.
The RT500 offers great versatility with its programming options, allowing
the user to programme the unit to operate on a 5/2 or 7 day control cycle.
The programmable thermostat has a default set of Programmes that have
been designed to meet the needs of most users. If these default
programmes are not suitable for your particular situation, reprogramming
the RT500 with your own settings is a very straightforward operation.
5/2 day mode is the default programming mode for the RT500. With this
mode selected, five different sets of time and set point temperatures can be
set for Weekdays or Weekends.
To review or change a programme, press the SET key when the RT500 is in
Normal mode. This will change the unit status to Programme Setting
mode.
The LCD display will display programme number 1 and SET PROG, with all
other indicators cleared. The weekdays will be flashing to indicate they are
the selected item and are ready to be adjusted:
Press the UP or DOWN key to select the programme set for either Weekday
or Weekend to be reviewed or adjusted. Pressing the SET key at any time
when in programming mode will return the RT500 into Normal mode.
Press the SELECT key to confirm the Weekday or Weekend selection. Once
this is set, the ‘Hour’ will flash to indicate that it is the selected item and is
the next item to be adjusted:
Pressing the SELECT key allows you to step through each of the items to be
reviewed or adjusted within the programmes in the following sequence:
…before then allowing you to cycle back to Programme 1. Pressing the SET
key at any time will confirm the setting and return to the programme set
selection.
7 Day Mode
The RT500 also offers a 7 day programming mode, which allows you to
programme five different sets of time and set point temperatures for each
day of the week to give a total of 35 separate programme settings.
To review or change a programme, press the SET key when the RT500 is in
Normal mode. This will change the unit status to Programme Setting
mode.
Pressing the SET key at any time when in programming mode will return
the RT500 into Normal mode. Press the SELECT key to confirm the Day
selection. Once this is set, the ‘Hour’ will flash to indicate that it is the
selected item and is the next item to be adjusted:
Press the UP or DOWN key to adjust the hour setting to the desired value,
and confirm your selection by pressing the SELECT key.
Pressing the SELECT key allows you to step through each of the items to be
reviewed or adjusted within the programmes in the following sequence:
…before then allowing you to cycle back to Programme 1. Pressing the SET
key at any time will confirm the setting and return to the programme set
selection. Each programme for all the other days of the week is set in exactly
the same way – just repeat the steps shown above, after entering
programming mode and selecting the day you want to programme.
Regardless of which programming mode the RT500 is set for (5/2 or 7 day),
not pressing any keys for 15 seconds will automatically save any
programming changes and exit to Normal mode. You can also review or
change programme settings when Frost Protection is enabled.
FROST PROTECTION
To enable the Frost Protection mode, press and hold the BACKLIGHT /
FROST button for three seconds with the RT500 in Normal mode. Once
Frost Protection is enabled, the set point temperature is automatically set
to 5°C to provide protection from the risk of freezing.
To exit from the set point review, press any key except the UP or
DOWN keys, or don’t press any keys for approximately four seconds
– either of these actions will return the RT500 to Normal mode.
Temporary Override
It is possible to temporarily override the current set temperature of the
RT500. There are two ways to do this:
• In Normal mode: press and hold either the UP or DOWN key to display
the set point temperature. After two seconds, the RT500 will enter
Temporary Override mode and allow increase or decrease of the set point
temperature. If the key is released within two seconds then you will only
be able to review the set point temperature.
Pressing the UP or DOWN key will increase or decrease the set point
temperature in 0.5 °C steps - the set point temperature can be adjusted
within a set range or 10 °C to 35 °C.
You can press SET at any time to confirm the new Temporary Override
setting and return to Normal mode, or press no keys at all and wait
approximately four seconds.
Battery Status
The RT500 checks the battery voltage frequently during normal
operation. If the battery voltage is sensed as being low (this is normally
when the battery voltage falls to a level of around 2.6V), the low battery
indicator will be displayed on the screen.
Reset Button
The Reset Button is provided as a way to restore the programmable
thermostat to its default factory settings. Pressing this button will
delete any previously entered settings.
Sleep Mode
By pressing both the UP and DOWN keys together, the RT500 will enter
SLEEP mode. In this mode, all the RT500 functions will be paused to save
battery power.
ENERGY TIP
One way to set and use your room thermostat is to find the lowest
temperature setting that you are comfortable with, and then leave it set at
this temperature. You can do this by setting the room thermostat to a low
temperature, (for example 17 °C) and then increasing the setting by one
degree each day until you are comfortable with the room temperature -
you won’t have to adjust the thermostat further, as adjustment above this
setting will waste energy - a 1 °C increase in temperature is equal to 3% of
your heating costs.
MAINTENANCE
The RT500 programmable thermostat requires no special maintenance.
Periodically, the outer casing can be wiped clean using a dry cloth (please
DO NOT use solvents, polishes, detergents or abrasive cleaners, as these
can damage the thermostat).
There are no user serviceable parts within the unit; any servicing or repairs
should only be carried out by SALUS Controls or their appointed agents.
• The batteries are the correct type, fitted correctly and are not
exhausted - fit new batteries if in doubt.
WARRANTY
SALUS Controls warrants that this product will be free from any
defect in materials or workmanship, and shall perform in
accordance with its specification, for a period of two years from the
date of purchase. SALUS Controls sole liability for breach of this
warranty will be (at its option) to repair or replace the defective
product.
PRODUCT SPECIFICATION
Model: RT500
Type: Electronic programmable
thermostat, designed for volt
free heating applications.
Programming
Programming Modes: User selectable for 5/2 or 7 day option
Number of Programmes: Five (5) user programmes plus
factory default programme.
Override Facility: User selectable programme
override facility.
Default Programmes
Programme Output Weekday Weekend
1 ON 6:00 AM 6:00 AM
TEMP 21 ºC 21 ºC
2 ON 8:00 AM 8:00 AM
TEMP 14 ºC 21 ºC
3 ON 4:00 PM 4:00 PM
TEMP 21 ºC 21 ºC
4 ON 6:00 PM 6:00 PM
TEMP 21 ºC 21 ºC
5 ON 10:00 PM 10:00 PM
TEMP 14 ºC 14 ºC
Temperature
Scale: Celsius
Range: 5 ºC to 35 ºC
Resolution: 0.5 ºC
Tolerance: Less than ± 0.5 ºC at 25 ºC
Display Range: 5.0 ºC to 45.0 ºC
Display Resolution: 0.5 ºC
Clock
Accuracy: ± 1 minute per month
Display: 12 hour
Frost Protection
Setting: 5 ºC
Switching
Switching Voltage: 0 - 230V AC / 50Hz
Switching Current: 3A resistive, 1A inductive
Contact Type: Single Pole Single Throw (SPST)
Power Source
Power Source: 2 x AA alkaline batteries
(Don’t use rechargeable batteries)
Battery Life: Approximately 1 year
Temperature
Range: 5 ºC to 35 ºC
Accuracy: ± 0.5 ºC at 25 ºC
Environment
Operating Temperature: 0 ºC to + 50 ºC
Storage Temperature: - 20 ºC to + 55 ºC
RT500 Warranty
SALUS Controls warrants that this product will be free from any defect in
materials or workmanship, and shall perform in accordance with its
specification, for a period of two years from the date of purchase.
SALUS Controls sole liability for breach of this warranty will be (at its
option) to repair or replace the defective product.
...............................................................................
Email: .....................................................................
Email: ....................................................................
salus-tech.
Sales: Email: [email protected] Tel: 01226 323961