HA Repair Guide: SSEDA - RS261

Download as pdf or txt
Download as pdf or txt
You are on page 1of 48

HA Repair Guide

Refrigerator

SSEDA – RS261*

Downloaded from www.Manualslib.com manuals search engine - 1/47 -


SSEDA-PJT Repair Guide
[ RS261M* ]

• No Ice / dispensing problem


No Ice
• Shortage of ice

• No Water / Water Dripping


No Water
• Water Leak

Defrost • Evap Defrost build

• Water hose Noise


Noise
• Unit Noise

• Weak Cooling(F/R)
Cooling
• Cooling Too Cold

Error CODE • Detail Error Code

Downloaded from www.Manualslib.com manuals search engine - 2/47 -


● Ice & Water
#1. Symptom : No Ice Repair Schematic

Chassis Project Basic Model Type

SBS SSEDA RS261M* Plastic Ice Maker

※  Check Display “ICE off” selecting


Tip Block
Check-1 Reason Step Check-2
Code #1 #2 #3
Display selection  Inspect Display Water 1-1 Panel- Wire Main
problem & Ice selection PBA Harness PBA

Lever S/W sensing  Inspect LEVER S/W 1-2 Panel- Wire Ice
problem operation PBA Harness Bucket
Ice Bucket  Inspect Bucket
ice exist assembly
(dispensing
Auger Motor S/W  Inspect Auger Motor Auger Wire
problem)
defect S/W operation Motor Harness
S/W
Auger Motor failure  Inspect ASSY AUGE 1-3 ASSY Wire Main
R-MOTOR operation Auger Harness PBA
Motor

Ice maker water  Inspect WATER 2-1 External Water Filter


supplying problem connection/ supply conn. Hose
(Water
supply)

 Inspect Ice Valve 2-2 Wire Ice Valve


operation Harness
 Inspect ASSY PIPE- 2-3 Pipe -
Ice Bucket WATER (HEATER) WATER
No ice/less ice freezing
(ice making Ice maker/sensor /  Self diagnosis test 2-4 Ice Wire Main
problem) Fan Motor Display “Lighting”+ Maker Harness PBA
problem “Energy Saver” Sensor
Fan
Damper

Cooling power  Measure cooling 2-5


failure power inspection Cycle
Comp
(Water exist on  Inspect Comp / Fan Shield C-fan
Relay
Tray) motor System

Downloaded from www.Manualslib.com manuals search engine - 3/47 -


Tip 1-1. Inspect Display Water & Ice selection

Check Point Inspect “Ice Type” button select operation

Step 1

① Check “Child Lock” selection

② Inspect “Ice Type” Key operation

- Key normal  Inspect Tip 1-2


- Key failure  Inspect Step 2

Step 2

① Check PANEL PBA WIRE HARNESS contact


- Inspect No.10(WHT)”and 14(W/BLK)” WIRE

② Check Wire harness after disassemble the


HINGE-UPP COVER
- Inspect No.10(WHT)and 14(W/BLK) Wire

Step 3

① Disassemble Main PBA Cover which is on the


back
② Inspect Connector which is on the right
bottom
- Inspect CN51 No.10(WHT)and
No.12(W/BLK)
③ If there is no problem fro all
- Check the PANEL PBA replacement and
repairing

If it is not solved
- Replace and repair MAIN PBA

Downloaded from www.Manualslib.com manuals search engine - 4/47 -


Tip 1-2. Inspect Lever S/W & Auger Motor S/W operation

Check Point Inspect Dispenser Lever S/W operation.

Step 1
① Check the Auger motor rotation sound which
is inside of F room with pushing DISPENSER
LEVER.

- When operation sound does not appear,


check Step 2
- When operation sound appears, check
“STEP 4”
Step 2
① Check Auger Motor S/W which is on the
door top of F room
- Check the S/W button with F room door
closing condition.
(Check it couldn’t push or damaged)

② After disassemble Connector and set Tester


as resistance and push S/W with hand, check
that is “0Ω”

※ It does not operate when the F room


door S/W is failure
Step 3
① After disassemble Display, push Lever and
check the Micro S/W pushing check which is
on left side.
※ Check it couldn’t push or damaged.

When there is no problem


① Check the wire Harness contact after
disassemble HINGE-UPP COVER
- Inspect No.6(YEL)and 10(GRAY) Wire
② Inspect Main PBA Connector
- Inspect CN50 No.6(YEL) and 10(GRAY)
Wire
Step 4
① Inspect less inserting of Ice Bucket.
- Pull the Bucket with pushing up toward top
※ if less inserting, Auger Motor rotation is
not passed and ice does not dispense

Downloaded from www.Manualslib.com manuals search engine - 5/47 -


Tip 1-3. Inspect ASSY Auger Motor operation

Check Point Inspect Auger Motor.

Step 1

① Disassemble ice Bucket which is in F room.

② Disassemble 3 screws on the top.

Step 2 (Single product inspection)

① Disassemble ice bucket which is in freezer.

② Disassemble Auger Motor, inspect Motor


- Normal product GRY+BLK 3~4 Ω
- Failure part : Open & 0 Ω

Step 3

① Disassemble the Main PBA Cover which is on


the back

② Inspect Connector which is on right bottom


- Inspect CN70 No.3(RED)and CN73 No.9(PRK)

Downloaded from www.Manualslib.com manuals search engine - 6/47 -


Tip 2-1. Inspect Water supply / supply

Check Point Inspect Water supply failure

※ Need lever operation for 3 min on initial and after replace Filter !
Step 1
① Inspect water comes when lever operation
after Water selection.
※ Initial product needs Water Tank filling time
- When the water does not come Check Step 2
- When the water comes Check TIP 2-4

Step 2 (Connection problem- Bending Hose)


① Inspect connection condition between
external tap and product connect
- Inspect connection of water pipe
- Inspect tap is closed.
② Inspect back Water Hose bending.

Step 3 (Piercing Valve using problem)


① Check hole blocking to not supplying water
when use Piercing Valve.

※ Check water supplying after disassemble


refrigerator connecting Hose Piercing Valve

Step 4 (Filter Case problem)


① Water supplies after remove Water Filter, but
water does not come after connect.

- Replace filter case in same problem when


replace other filters.

Step 5
① When the water comes well through water
line, check water pressure when use external
water filter.

※ Water pressure of supplying should over


20PSI.

Downloaded from www.Manualslib.com manuals search engine - 7/47 -


Tip 2-2. Inspect Ice Valve operation

Check Point Inspect ice maker Water supplying problem

Step 1 ① 점ㄱ

① Push the button for 2 sec which is on the


bottom of ice maker after disassemble Ice
Bucket.

② Check the water supplying after ice maker


tray twist operation.
- When the water does not come  Check
the Step 2
- When the water comes Check TIP 2-5
Step 2
① Disassemble the backside Unit Cover .
② Check Purple 2-Wire after disassemble ASSY
Valve
- Normal part: 350~450 Ω
- Failure part : Open or 0 Ω
③ Disassemble the Main PBA Cover which is on
the back
④ Inspect Connector which is on right bottom
- Inspect CN70 No.3(RED)and CN73
No.7(PRP)
① Disassemble Unit Cover 2-
inspect Wire
CN 73 No.7(PRP) + CN70
No. 3(RED)

CN 70 CN 73

Downloaded from www.Manualslib.com manuals search engine - 8/47 -


Tip 2-3. Inspect ASSY PIPE-WATER (Heater) freezing

Check Point Inspect ice maker Water supply problem

Step 1

Connector

① Disassemble the Ice Maker which is on top of


F room.
② Disassemble top PIPE-WATER Heater Wire.
- Normal product 1.8 ~ 2.5 KΩ
- Failure part : Open or 0 Ω

Circuit diagram ① Inspect 2-Wire connector

-Main PBA : CN70


No.5(BRN) + CN71
No.1(ORG)

Main PBA

CN 70,71

Downloaded from www.Manualslib.com manuals search engine - 9/47 -


Tip 2-4. Inspect Self diagnosis test (※ Must select “Power Freeze” first)
※ Fan motor Fan motor displays failure for
power on condition.
Touch Display “Lighting”+ “Energy Saver” Key for
8 sec at the same time.
- Press until all LED blink and “dingdong” sound
appears.
- No problem on self-diagnosischeck TIP 2-2
Display (Image) Failure Item Measure IMAGE

R실 "약" Ice Maker Sensor Inspect F ice maker + Wire


Harness
① F room icemaker connector
Ice Maker function ② Main PBA CN90
R실 "강"
failure

Disassemble Cover Multi Front


① Inspect Sensor Wire
F실 "약약중" F cabinet Sensor
② Main PBA CN40 No.5(YEL)
CN50 No.5(GRY)
Disassemble Cover Evap
① Inspect Sensor Wire
F실 “weak-mid” F defrost SENSOR
② Main PBA CN40 No.6(BLU)
CN50 No.5(GRY)
Disassemble Cover Multi
① Inspect Fan Wire
F실 "중" F-cabinet FAN ② Main PBA CN75
No.4(YEL)+No.5(BLK)+No.1
0(GRY)
Check Evap Cover disassemble
defrost heater
① Inspect defrost heater
F실 "강" F defrost Error
housing
② CN70 No.5(BRN)+CN72
No.1(ORG)

Disassemble R Cover Damper


R “Mid” R cabinet Sensor ① Main PBA CN40 No.9(BLK)
CN50 No.5(GRY)

R vibration Disassemble R Cover Damper


R “Mid-mid-strong” Damper ① Inspect Main PBA CN76
Heater No.4~9

Inspect machinery room


F “Mid-mid-strong" C-FAN ERROR
COVER disassemble C-Fan

Check R door HINGE-UPP


External air SENSO disassemble
F “weak"
R ① Main PBA CN40
- No.1(YEL)+2(YEL)

Downloaded from www.Manualslib.com manuals search engine - 10/47 -


Tip 2-4-1. Inspect self-diagnosis test
 Inspect Ice Maker

Block

Connector

① Disassemble F Ice Maker Screw Top


② Inspect Wire Harness connection which is on Sensor
The top part.
※ Ice maker test operates and water does not come,
Check TIP 2-2
※ No problem on Test and water supply, check TIP 2-5 Test
button
Circuit diagram ① When Sensor failure
:Inspect No.5(WHI) + 6(WHI)
② When the Sensor is normal
: Ice Maker bottom Test
button
※ Press 2sec
③ Check ice maker operation
※Inspect Twist problem Wire
check and replace ice maker

Motor Twist Water supply

Main PBA ① When the Sensor is failure


“CN 90”
: Inspect No.5(WHI) + 6(WHI)
② When the Ice Maker Test
operation is failure
Inspect “CN 90”
- rotate operation:
1(RED)=2(BLK)
CN 90 - output sensing: 5(BLU)
- Test input: 4(S/BLU)

Downloaded from www.Manualslib.com manuals search engine - 11/47 -


Tip 2-4-2. Inspect self-diagnosis test
 F Sensor / Cabinet Fan / Defrost Sensor / Defrost Error

Block
D-Sensor
F-Sensor

Fan Motor

① Disassemble F Ice Maker Screw top


Heater
② Inspect Cover Multi Front disassemble
③ Inspect Evap Cover disassemble Defrost
Sensor

Circuit diagram ① When the F cabinet Sensor


failure
: Inspect disassembled Cover
Multi Front blue2-Wire
connector
-Main PBA : CN40 No.5(YEL)
+ CN50 No.5(GRY)
② When F Fan is failure
: Inspect disassembled Cover
Multi Front 3-Wire connector
-Main PBA : CN75 No.4(YEL)
/ No.5(BLK) / No.10(GRY)
③ When the Defrost Sensor is
failure
Main PBA : Inspect Evap Cover
disassembled blue 2-Wire
-Main PBA : CN40 No.6(BLU)
CN 70,71 + CN50 No.5(GRY)
④ Defrost Error
CN 40 : Inspect brown 2-Wire
connector
-Main PBA : CN70 No.5(BRN)
CN 50 + CN71 No.1(ORN)
CN 75

Downloaded from www.Manualslib.com manuals search engine - 12/47 -


Tip 2-4-3. Inspect self-diagnosis test
 R Sensor / F Damper Motor

Block
R-Sensor
Damper
Damper

① Disassemble R Ice Maker Screw top


② Inspect Cover Multi Front disassembly
③ Inspect Evap Cover disassembly
R-Sensor

Circuit diagram ① When the R cabinet Sensor is


failure
: Inspect disassembled Cover
Damper blue 2-Wire
connector
-Main PBA : CN40 No.9(BLK)
+ CN50 No.5(GRY)

② When the R Damper Motor is


failure
: Inspect disassembled Cover
Damper 6-Wire connector
-Main PBA : CN76 No.4(BLK)
/ 5(BRN) / 6~9
Main PBA

CN 70,71

CN 40

CN 76

CN 50

Downloaded from www.Manualslib.com manuals search engine - 13/47 -


Tip 2-4-4. Inspect self-diagnosis test
 External R Sensor / C-Fan Motor

Block

C-Fan

EXT-Sensor

- Inspect external air sensor


① Inspect R top HINGE-UPP Cover disassembled Wire

- Inspect C-Fan Error Inspect


① Inspect disassembled Unit Cover Fan restriction / Wire Connector

Circuit diagram ① When external air Sensor is


failure
: Inspect R HINGE-UPP Cover
disassembled yellow 2-Wire
-Main PBA : CN40 No.1(YEL)
+ 2(YEL)

② When the C-Fan Motor is


failure
: Inspect Unit Cover
disassembled 3-Wire
connector
-Main PBA : CN75
No.2(S/BLU) / 7(RED) /
Main PBA 10(GRY)

CN 70,71

CN 40

CN 76

CN 50

Downloaded from www.Manualslib.com manuals search engine - 14/47 -


Tip 2-5. Inspect cooling power (※ Must select “Power
Freeze” first)
※ Do not off the power  Measure self-diagnosis test on
“TIP 2-4”
Step 1
Press Display “Lighting”+ “Energy Saver” Key for
8sec at the same time.
- Press until all LEDs are Blinking and “dingdong”
sound appears

※ When the Error occur  Move to TIP 2-4


-If there is no problem  Check Step 2
Step 2 (Inspect Comp operation)
① Press Display “Freezer” for 3sec to being
“Power Freeze”.
※ Satisfy setting temperature and defrost
performance comp off.
(Operate 7min off when the COMP operate
again)

② Inspect backside Comp operation.


(Check operation with touching comp using
hand.)

- Comp does not operated  Check Step 3


- Comp operates  Check Step 6
Step 3 (Inspect Comp Wire )

① Inspect backside left of Unit Comp Wire


Connector
② Disassemble Comp left Relay Cover and Connector
inspect OLP & PTC-Relay separation separation
③ Inspect PTC-Relay Wire changing
- Sub Coil left PNK, Main right S/BLU

Relay
separation

Normal Changed PTC


Relay
Downloaded from www.Manualslib.com manuals search engine - 15/47 - Next Page
Step 4 (Comp single product operation failure)

① Inspect rotation failure by Comp Coil cutting


- Measure Common + Sub resistance
- Measure Common + Main resistance
Normal : 1~50 Ω
Failure : Open ∞ Ω

Step 5 (Comp Relay Failure)

① Inspect power supply Line


- Comp operation condition is normal : AC
100~125 V
- Failure : AC voltage non-applying (Inspect
power line)
② Inspect Comp OLP(Over Load Protection)
- Normal : applying an electric current 0~1 Ω
- Failure : Open ∞ Ω
③ Inspect PTC Relay
- Normal : 0.8~1.4 KΩ
- Failure : Open ∞ Ω

Step 6 (Gas Leak failure)

① Comp operates but, if Comp-dome & Pipe-


Condenser temperature is not high, repair
cycle shield system because it is failure of
Gas Leak & Clogged

Step 4 (When C-Fan is failure)

① When C-Fan operates or “FG” Signal is failure,


comp stops after 60min..
※ Must check “FG” failure through self-
diagnosis test, even the Fan is still rotating.

Inspect
Connector

Downloaded from www.Manualslib.com manuals search engine - 16/47 -


● Ice & Water
#2. Symptom : No Water & other(LEAK) Repair distribution diagram

Chassis Project Basic Model Type

SBS SSEDA RS261M* Plastic Ice Maker

※ Check Display “Hold” selection


Tip Block
Check-1 Reason Step Check-2
Code #1 #2 #3
WATER supply  Inspect WATER 3-1 External Water CASE-
problem connection / supply connecti Hose Filter
on
 ASSY CASE-WATER (Water
FILTER supply failure supply)

WATER VALVE  Inspect WATER 3-2 WATER WIRE


problem VALVE VALVE HARNES
S

No Water WATER LEVER S/W  Inspect LEVER S/W 3-3 LEVER DOOR WIRE
operation S/W S/W HARNES
S
 Door S/W

WATER Hose  WATER HOSE 3-4 TUBE-FI F-DOOR


Problem bending TTING

 Inner door hose


blocking/freezing

WATER LINE Leak  CONNECTOR 4-1 TUBE-FI CASE- WATER


TTING FILTER VALVE
 WATER LINE

DISPENSER DRIP  Inspect connection 4-2 TUBE-FI WATER COCK


Other - WATER DROP part TTING VALVE
- ICE ROUTE  Inspect WATER
Water Leak VALVE
&  Inspect supplied
Noise WATER

WATER HOSE  Inspect FILTER CASE 4-3 cock CASE-FI


Noise (quake failure) LTER

Downloaded from www.Manualslib.com manuals search engine - 17/47 -


Tip 3-1. Inspect WATER connection / supply

Check Point Inspect Water supply failure


※ Need lever operation for 3 min on initial and after filter
replacement !
Step 1
① Inspect lever water coming after Water
selecting.
※ Takes water tank filling time of initial product
- When the water does not come  Check Step
2
- When the water comes  Check TIP 2-4
Step 2 (Connection problem-Hose bending)

① Inspect external tap and product connection


condition
- Inspect the water pipe is not connected
- Inspect the tap is closed.
② Inspect backside Water Hose bending.
Step 3 (Piercing Valve using problem)

① Check the water supplying when use Piercing


Valve. Piercing Valve
※ Check water supplying after disassemble
refrigerator hose

Step 4 (CASE WATER Filter problem)

① When remove Water Filter water supplies,


when connect it water does not come.
※ When the other filter replace, and same
symptom appear, Replace case water filter.

※ Check Filter & Water tank freezing when Too


Cold
① Replace filter for long term using FILTER Freeze the filter & tank
Step 5 (Water pressure problem)

① If the water supplies well through water line,


check water pressure can be decreased when
the external Water Filter using.

※ Supply water should be at least over


20PSI.
Downloaded from www.Manualslib.com manuals search engine - 18/47 -
Tip 3-2. Inspect WATER VALVE operation

Check Point Inspect WATER VALVE failure

Step 1

① Disassemble backside UNIT COVER.

Step 2
① After disassemble ASSY Valve and check
WHITE 2-Wire
- Normal parts : 350~450 Ω
- Failure parts : Open or 0 Ω

② Disassemble Main PBA cover which is in the


backside

③ Inspect Connector which is on the right


bottom
- Inspect CN70 No.3(RED)and CN73
No.1(W/BLK)
① Inspect disassembled Unit
Cover 2-Wire
CN 73 No.1(W/BLK) +
CN70 No.3(RED)

CN 70
CN 73

Downloaded from www.Manualslib.com manuals search engine - 19/47 -


Tip 3-3. Inspect WATER Lever S/W operation

Check Point Inspect Dispenser Lever S/W operation.

Step 1

① After select DISPENSER WATER and check


water coming with pressing LEVER

Step 2
MAGNET CHECK
① Inspect F DOOR UPP MAGNET existence

② Inspect disassembled HINGE-UPP COVER


DOOR S/W &WIRE CONNECTOR OPEN

※ Not operation when DOOR S/W is


failure

Step 3

① After disassemble Display, check left micro


S/W pressing to press Lever.
※Check non-pressing, damage

② After disassemble HINGE-UPP COVER and


check WIRE HARNESS connection
- Inspect PINK & GRAY Wire

③ Inspect Main PBA Connector


- Inspect CN50 No.7(PIK)and 10(GRAY) Wire

CN 50

Downloaded from www.Manualslib.com manuals search engine - 20/47 -


Tip 3-4. Inspect WATER HOSE

Check Point Inspect WATER HOSE LINE

Step 1

① Disassemble COVER-LEG FRONT.

Step 2

① Check it is the problem of WATER HOSE


TUBE FITTING connection and disassemble it
if there is no problem.

② On DOOR ALL CLOSE condition, check the


water comes of hose when WATER LEVER
operate.

- Inspect F door hose if Hose from CABINET


side flows water  STEP 3

※ When the water doesn’t come from HOSE


Check TIP 1-1

Step 3
① Check F-DOOR HINGE-LOW part WATER
HOSE bending.

② Replace the door because of Clogged


problem or inner water hose freezing when
there is no problem on F DOOR HINGE-LOW
HOSE.

Downloaded from www.Manualslib.com manuals search engine - 21/47 -


Tip 4-1. Inspect WATER LINE LEAK

Check Point Inspect WATER HOSE LINE LEAK

Step 1

① Disassemble COVER-LEG FRONT.

- FRONT WATER LEAK


- ROOM WATER LEAK
- BACK WATER LEAK

Step 2

① Inspect WATER HOSE SCRATCH


 Re-connection after cutting the SCRATCH
part

② Less inserting amount of TUBE FITTING HOSE


 Re-insert to the inside
HOSE SCRATCH
③ HOSE CUTTING as diagonal.
 Connect after re-cutting as right angle

GOOD
Less
NG inserting

Step 3

① Inspect R CASE FILTER inner TUBE FITTING


connection part CLIP connect omit and HOSE
inserting failure

② Inspect backside WATER VAVLE HOSE

③ Inspect backside HOSE connection

CLIP CLIP Omit

Downloaded from www.Manualslib.com manuals search engine - 22/47 -


Tip 4-2. Inspect WATER DISPENSER DRIPPING

Check Point Inspect WATER HOSE LINE LEAK

Step 1

① Disassemble COVER-LEG FRONT

※ WATER DRIPPING occurs


as WATER LINE AIR

Step 2

① Inspect WATER HOSE SCRATCH


HOSE SCRATCH
 Re-connect after cutting
SCRATCH part

Step 3
① Inspect WATER TANK AIR

② Pressing WATER LEVER and shake CASE


FILTER as left-right to dispense inner Air to
outside.
Step 4

① Disassemble UNIT WATER VALVE HOSE and


inspect water leak on Closing condition.

Step 5
① Disassemble Water hose which is connected
to product.
② Inspect bubble occurrence in the water when
BUBBLE
supply water to container.
- When BUBBLE appears it is not the
problem of the product.
Step 6

① Ice which is made during ICE dispensing


meld and flow to CASE DISPENSER is normal
phenomenon.

- Customer explanation
Downloaded from www.Manualslib.com manuals search engine - 23/47 -
Tip 4-3. Inspect WATER HOSE NOISE

Check Point Inspect WATER HOSE LINE LEAK

Step 1 HOSE
VIBRATION
① Dispense water with pressing WATER LEVER.

- Inspect supply water pressure problem


- Inspect CASE-FILTER problem

Step 2

① Check backside hose quake sound when


operate with pressing WATER LEVER.

② Improve supplied water pressure with VALVE


adjusting.

Step 3

① When hose continuously shaves even


adjusting water pipe VALVE

② Disassemble FILTER.
-After disassemble the FILTER and hose is
not shaken after dispensing WATER replace
FILTER CASE.

Downloaded from www.Manualslib.com manuals search engine - 24/47 -


● DEFROST
#1. Symptom : EVAP / ICE ROUTE DEFROST Repair

Chassis Project Basic Model Type

SBS SSEDA RS261M* Plastic Ice Maker

※ Operate self-diagnosis test


Tip Block
Check-1 Reason Step Check-2
Code #1 #2 #3
DEFROST ERROR /  Self diagnosis test 5-1 Sensor WIRE H Main
sensor / Display “Lighting”+ Fan ARNESS PBA
Fan Motor “Energy Saver” Damper
problem

EVAP DEFROST  Only the top of the 5-2 DEF-Sen HEATER Main
BUILD problem EVAP ice. sor PBA
EVAP
DEFROST  Only the bottom of
BUILD the EVAP ice.

 All EVAP ice.

ICE ROUTE  Inspect COVER-ICE 6-1 COVER-


assembly problem ROUTE LEAK ICE RO
UTE
 Inspect CASE-LEVER
DISPENSER
DISP
DEFROST
BUILD

Downloaded from www.Manualslib.com manuals search engine - 25/47 -


Tip 5-1. Self diagnosis test inspection (※ Must select “Power Freeze” first)

※ Fan motor displays failure for power on


condition.
Press Display “Lighting”+ “Energy Saver” Key for
8sec at the same time.
- Press until all LEDs are Blinking and “Dingdong”
sound occur
- Normal on self-diagnosis test check TIP 5-2
Display (Image) Failure Item Measure IMAGE

R실 "약" Ice Maker Sensor Inspect F ice maker + Wire


Harness
① F icemaker connector
Ice Maker function
R실 "강" ② Main PBA CN90
failure

Disassemble Cover Multi Front


① Inspect Sensor Wire
F실 "약약중" F cabinet Sensor
② Main PBA CN40 No.5(YEL)
CN50 No.5(GRY)

Disassemble Cover Evap


① Inspect Sensor Wire
F “weak-mid" F defrost SENSOR
② Main PBA CN40 No.6(BLU)
CN50 No.5(GRY)

Disassemble Cover Multi


① Inspect Fan Wire
F실 "중" F-cabinet FAN
② Main PBA CN75
No.4(YEL)+5(BLK)+10(GRY)
Check disassemble Evap Cover
defrost heater
① Inspect defrost heater
F실 "강" F defrost Error
housing
② CN70 No.5(BRN)+CN72
No.1(ORG)

Disassemble R Cover Damper


R “Mid” R cabinet Sensor ① Main PBA CN40 No.9(BLK)
CN50 No.5(GRY)

R vibration Disassemble R Cover Damper


R “Mid-mid-strong” Damper ① Inspect Main PBA CN76
Heater No.4~9

Inspect machinery room


F “Mid-mid-strong" C-FAN ERROR
COVER disassembled C-Fan

Check R door HINGE-UPP


External air SENSO disassembly
F “weak"
R ① Main PBA CN40
- No.1(YEL)+2(YEL)

Downloaded from www.Manualslib.com manuals search engine - 26/47 -


Tip 5-1-1. Inspect self-diagnosis test
 Inspect Ice Maker

Block

Connector

① Disassemble F Ice Maker Screw top


② Inspect wire harness contact on the top.
Sensor
※ Ice maker test operation but water doesn’t come
refer to TIP 2-2
※ Test and water supply don’t have problem,
Test
refer to TIP 2-5
button
Circuit diagram ① When the Sensor is failure
: Inspect no.5(WHI) + 6(WHI)
② When the Sensor is normal
: Ice Maker bottom Test
button
※ Press for 2sec
③ Check icemaker operation
※After check the Twist problem
Wire inspection, replace icemaker

Motor Twist Water


supply
Main PBA ① When the Sensor is failure
“CN 90”: inspect no.5(WHI) +
6(WHI)

② Inspect “CN 90” when Ice


Maker Test operation failure

- Rotating operation:
CN 90 1(RED)=2(BLK)
- Output sensing: 5(BLU)
- Test input: 4(S/BLU)

Downloaded from www.Manualslib.com manuals search engine - 27/47 -


Tip 5-1-2. Inspect self-diagnosis test
 F Sensor / cabinet Fan / Defrost Sensor / Defrost Error

Block
D-Sensor
F-Sensor

Fan Motor

① Disassemble F Ice Maker Screw top


Heater
② Inspect disassembled Cover Multi Front 분해
③ Inspect disassembled Evap Cover Defrost
Sensor

Circuit diagram ① F cabinet Sensor is failure


: Inspect disassembled Cover
Multi Front blue 2-Wire
connector
-Main PBA : CN40 No.5(YEL)
+ CN50 No.5(GRY)

② When F Fan is failure:


Inspect disassembled Cover
Multi Front 3-Wire connector
-Main PBA : CN75 No.4(YEL)
/ No.5(BLK) / No.10(GRY)

③ When the Defrost Sensor is


Main PBA failure
: Inspect disassembled Evap
CN 70,71 Cover blue 2-Wire
-Main PBA : CN40 No.6(BLU)
CN 40 + CN50 No.5(GRY)

④ Defrost Error
: Inspect brown 2-Wire
CN 50
CN 75 connector
-Main PBA : CN70 No.5(BRN)
+ CN71 No.1(ORN)

Downloaded from www.Manualslib.com manuals search engine - 28/47 -


Tip 5-1-3. Inspect self-diagnosis test
 R Sensor / F Damper Motor

Block
R-Sensor
Damper
Damper

① Disassemble F Ice Maker Screw top


② Inspect disassembled Cover Multi Front
③ Inspect disassembled Evap Cover
R-Sensor

Circuit diagram ① When the R cabinet Sensor is


failure
: Inspect disassembled Cover
Damper blue 2-Wire
connector
-Main PBA : CN40 No.9(BLK)
+ CN50 No.5(GRY)

② When the R Damper Motor is


failure
: Inspect disassembled Cover
Damper 6-Wire connector
-Main PBA : CN76 No.4(BLK)
/ No.5(BRN) / No.6~9
Main PBA

CN 70,71

CN 40

CN 76

CN 50

Downloaded from www.Manualslib.com manuals search engine - 29/47 -


Tip 5-1-4. Inspect self-diagnosis test
 External air R Sensor / C-Fan Motor

Block

C-Fan

EXT-Sensor

- Inspect external sensor


① Inspect disassembled R top HINGE-UPP Cover Wire

- Inspect C-Fan Error Inspect


① Inspect disassembled Unit Cover Fan restriction / Wire Connector

Circuit diagram ① When the external air Sensor


is failure
: Inspect disassembled R
HINGE-UPP Cover yellow 2-
Wire
-Main PBA : CN40 No.1(YEL)
+ No.2(YEL)

② When the C-Fan Motor is


failure
: Inspect Unit Cover
disassembled 3-Wire
connector
-Main PBA : CN75 No.2
Main PBA (S/BLU) / No.7(RED) /
No.10(GRY)

CN 70,71

CN 40

CN 76

CN 50

Downloaded from www.Manualslib.com manuals search engine - 30/47 -


Tip 5-2. Inspect EVAP DEFROST BUILD
※ Do not off the power and operate self-diagnosis test on “TIP 5-1”
first.
 Must check the forced defrost operation after defrosting repair.
Step 1

Press Display “Lighting”+ “Energy Saver” Key for 8


sec at the same time until “Dingdong” sound
appear.
※ When the Error occurs  Measure it to
move TIP 5-1. Defrost
- When there is no ERROR, or DEFROST ERROR
Error
 Check Step2
Step 2
① Disassemble EVAP COVER EVAP-FRE FRONT
& COVER Multi.

② Melt right CONNECTOR part with STEAMER


and disassemble the COVER.

Step 3 HEATER
& BIMETAL
① Measure BROWN WIRE resistance.
- Normal part : 35~60 Ω
- Failure part : Open or 0 Ω
 Replace it because of HEATER &
BIMETAL OPEN failure
Step 4

① When freezing appears on DEFROST SENSOR


part, replace it because it is SENSOR failure.

Step 5

① Bottom and DEF-SENSOR part don’t have


freezing and top center has freezing only.
-Location of DEF-SENSOR should move to
center pipe.
DEF-SENSOR
MOVE

Downloaded from www.Manualslib.com manuals search engine - 31/47 - Next Page


Step 6

① When it freezes only EVAP BOTTOM


- Improve DRAIN freezing.

② Check the drain hole blocking with


removing freezing with STEAMER.
(Remove DRAIN freezing and foreign
substance)
③ Bend the HATER to bottom with hand.
- DRAIN HOLE should be closed.
★ HEATER can not contact to PLATE.
Step 7 (Total inspection after defrost repairing) LED ALL OFF

① Check the heater operation with forced


defrost operation after complete repairing.
Press “Lighting”+ “Fridge” at the same time ①Forced operation
and operate forced defrost to press “Fridge” (LED Full On)
key 2times after all LED off. ↓
②Forced defrost
Check the HEATER(Brown-wire) AC voltage ↓
supplying when “beep” sound appears. ③ OFF

② Off with same way when there is no problem.

Step 8 Inspect MAIN PBA CN70 No.5


① Inspect Main PBA and Connector open when (BRN)+CN71 No.1(ORG)
the AC power is not supplied.
② Replace the Main PBA if there is no problem. - LINER CONNECTOR BROWN
2WIRE

Downloaded from www.Manualslib.com manuals search engine - 32/47 -


Tip 6-1. Inspect ICE ROUTE DEFROST BUILD

Step 1

① Check frost attachment with ICE ROUTE on F-


DOOR OPEN condition.

- If the frost appears on ICE ROUTE only, it


appears because of ICE dispensing so that
is normal.

Step 2 ( When freezing appears until ICE


BUCKET bottom)
① Inspect water leakage with flashing on F- When the
DOOR OPEN ICE ROUTE top or pouring light leaking
water
② Failure when water or light leak

③ Assemble to check the COVER ICE ROUTE


assembly condition and should be no
swerving.

조립불량

Step 3

① Replace ASSY CASE-LEVER DISP if it is not


assembly problem.

Downloaded from www.Manualslib.com manuals search engine - 33/47 -


● NOISE
#1. Symptom : Water Hose & UNIT NOISE Repair distribution diagram

Chassis Project Basic Model Type

SBS SSEDA RS261M* Plastic Ice Maker

※ Operate self-diagnosis test


Tip Block
Check-1 Reason Step Check-2
Code #1 #2 #3
WATER HOSE  Inspect FILTER CASE 7-1 Case-
Noise (Quake failure) Filter

Water
HOSE
NOISE

UNIT NOISE  Inspect COVER-ICE 8-1 Cover-


ROUTE LEAK Ice
Route
 Inspect CASE-LEVER
DISP

CYCLE NOISE  Refrigerant NOISE 8-2 EVAP


UNIT “Growling / water
NOISE sound”  DRYER

Downloaded from www.Manualslib.com manuals search engine - 34/47 -


Tip 7-1. Inspect WATER HOSE NOISE

Check Point Inspect Noise when WATER dispensing

Step 1 HOSE
VIBRATION
① Dispense water with pressing WATER LEVER.

- Inspect supplied water pressure problem


- Inspect CASE-FILTER problem

Step 2

① Check backside hose quake sound with


pressing WATER LEVER.

② Improve supplied water pressure adjusting


water pipe VALVE.

Step 3

① When quake hose even adjusting water valve

② Disassemble FILTER.
- Replace Filter case when the Hose does not
quake after disassemble FILTER and dispense
water.

Downloaded from www.Manualslib.com manuals search engine - 35/47 -


Tip 8-1. Inspect UNIT NOISE

Check Point Inspect UNIT NOISE

Step 1

① Disassemble backside UNIT COVER.

Step 2

① Inspect selecting “Power Freeze” and COMP


ON.
② Disassemble the part which is friction.

PIPE + WIRE PIPE + TRAY

PIPE + PIPE PIPE + TRAY

FAN + WIRE
PIPE + COVER

Downloaded from www.Manualslib.com manuals search engine - 36/47 -


Tip 8-2. Inspect CYCLE NOISE

Check Point Inspect NOISE

Step 1

① Disassemble backside UNIT COVER.

Step 2

① When “Pooo~” “growling” sound occurs in


the cabinet
② Disassemble EVAP COVER.
- Capillary Pipe welding part should be as “-”
shape.
③ Cover it with RUBBER.

PIPE should be straight.

Inspect RUBBER

④ Dryer angle in backside machinery should be


horizontal.

DRYER angle should be


horizontal.

DRYER angle

Downloaded from www.Manualslib.com manuals search engine - 37/47 -


● COOLING
#1. Symptom : WEAK COOLING & TOO COLD Repair

Chassis Project Basic Model Type

SBS SSEDA RS261M* Plastic Ice Maker

※ Operate self-diagnosis test


Tip Block
Check-1 Reason Step Check-2
Code #1 #2 #3
Inspect F WEAK  Self diagnosis test 9-1 Ice Wire Main
COOLING Display “Lighting”+ Maker Harness PBA
“Energy Saver” Sensor
Fan
Damper

Inspect R WEAK
COOLING
 Measure cooling 9-2 Comp Cycle C-fan
power inspection Relay Shield
System
WEAK  Inspect Comp / Fan
COOLING motor

 DEFROST BUILD 9-3 DEF-Sen Heater Main


sor PBA

R TOO COOLING  Inspect ASSY COVER 10-1 Cover INS-


DAMPER Damper Damper

 Inspect ASSY INS-


DAMPER
TOO COLD

Downloaded from www.Manualslib.com manuals search engine - 38/47 -


Tip 9-1. Inspect self-diagnosis test (※ Must select “Power Freeze” first)

※ Fan motor displays failure only for power On


condition.
Press Display “Lighting”+ “Energy Saver” Key for
8sec at the same time.
- Press until “Dingdong” sound appear after all
LEDs is blinking
- No problem
Display on self-diagnosis
(Image) test Check Measure
Failure Item IMAGE
TIP 9-2
R실 "약" Ice Maker Sensor Inspect F ice maker + Wire
Harness
① F ice maker connector
Ice Maker function ② Main PBA CN90
R실 "강"
failure

Disassemble Cover Multi Front


① Inspect Sensor Wire
F실 "약약중" F cabinet Sensor
② Main PBA CN40 No.5(YEL)
CN50 No.5(GRY)
Disassemble Cover Evap
F room defrost SE ① Inspect Sensor Wire
F “weak-mid"
NSOR ② Main PBA CN40 No.6(BLU)
CN50 No.5(GRY)
Disassemble Cover Multi
① Inspect Fan Wire
F “Mid" F-cabinet FAN ② Main PBA CN75
No.4(YEL)+No.5(BLK)+No.1
0(GRY)
Check disassembled Evap
Cover defrost heater
① Inspect defrost heater
F실 "강" F defrost Error
housing
② CN70 No.5(BRN)+CN72
No.1(ORG)

Disassemble R Cover Damper


R “Mid” R cabinet Sensor ① Main PBA CN40 No.9(BLK)
CN50 No.5(GRY)

R vibration Disassemble R Cover Damper


R “Mid-Mid-Strong” Damper ① Inspect Main PBA CN76
Heater No.4~9

Inspect disassembled
F “Mid-Mid-Strong”" C-FAN ERROR
machinery room COVER C-Fan

Check disassembled R door


HINGE-UPP
F “Weak" External air Sensor
① Main PBA CN40
- No.1(YEL)+No.2(YEL)

Downloaded from www.Manualslib.com manuals search engine - 39/47 -


Tip 9-1-1. Inspect self-diagnosis test
 Inspect Ice Maker

Block

Connector

① Disassemble F Ice Maker Screw top


② Inspect Top Wire Harness contact. Sensor
※ Water doesn’t come even ice maker operates Test,
TIP 2-2
※ If there is no problem on water supply problem
Test
and Test, TIP 2-5 button
Circuit diagram ① When the Sensor is failure
: inspect no.5(WHI) +
no.6(WHI)
② When the Sensor is normal시
: Ice Maker bottom Test
button
※ Press for 2sec
③ Check ice maker operation
※Replace ice maker after inspect
Twist problem Wire

Motor Twist Water supply


Main PBA ① When Sensor is failure “CN
90”
:Inspect No. 5(WHI) + 6(WHI)

② When the Ice Maker Test


operation is failure inspect
“CN 90”
- Rotate operation:
CN 90 1(RED)=2(BLK)
- Output sensing: 5(BLU)
- Test input: 4(S/BLU)

Downloaded from www.Manualslib.com manuals search engine - 40/47 -


Tip 9-1-2. Inspect self-diagnosis test
 F Sensor / cabinet Fan / Defrost Sensor / Defrost Error

Block
D-Sensor
F-Sensor

Fan Motor

① Disassemble F Ice Maker Screw top


Heater
② Inspect disassembled Cover Multi Front
③ Inspect disassembled Evap Cover Defrost
Sensor

Circuit diagram ① When F cabinet Sensor is


failure
: Inspect disassembled Cover
Multi Front blue 2-Wire
connector
-Main PBA : CN40 No.5(YEL)
+ CN50 No.5(GRY)

② When F Fan is failure


: Inspect disassembled Cover
Multi Front 3-Wire connector
-Main PBA : CN75 4번(YEL) /
5번(BLK) / 10번(GRY)

Main PBA ③ When Defrost Sensor is


failure
CN 70,71 : Inspect disassembled Evap
Cover blue 2-Wire
CN 40 -Main PBA : CN40 No.6(BLU)
+ CN50 No.5(GRY)

④ Defrost Error
CN 50
CN 75 : Inspect brown 2-Wire
connector
-Main PBA : CN70 No.5(BRN)
+ CN71 No.1(ORN)
Downloaded from www.Manualslib.com manuals search engine - 41/47 -
Tip 9-1-3. Inspect self-diagnosis test
 R Sensor / R Damper Motor

Block
R-Sensor
Damper
Damper

① Disassemble F Ice Maker Screw top


② Inspect disassembled Cover Multi Front
③ Inspect disassembled Evap Cover
R-Sensor

Circuit diagram ① When R cabinet Sensor is


failure
: Inspect disassembled Cover
Damper blue 2-Wire
connector
-Main PBA : CN40 No.9(BLK)
+ CN50 No.5(GRY)

② When R Damper Motor is


failure
: Inspect disassembled Cover
Damper 6-Wire connector
-Main PBA : CN76 No.4(BLK)
/ No.5(BRN) / No.6~9
Main PBA

CN 70,71

CN 40

CN 76

CN 50

Downloaded from www.Manualslib.com manuals search engine - 42/47 -


Tip 9-1-4. Inspect self-diagnosis test
 External R Sensor / C-Fan Motor

Block

C-Fan

EXT-Sensor

- Inspect external sensor


① Inspect disassembled R top HINGE-UPP Cover Wire

- Inspect C-Fan Error Inspect


① Unit Cover disassembled Fan restriction / Wire inspection Connector

Circuit diagram ① When external air Sensor is


failure
: Inspect disassembled R
HINGE-UPP Cover yellow 2-
Wire
-Main PBA : CN40 No.1(YEL)
+ No.2(YEL)

② When C-Fan Motor is failure


: Inspect disassembled Unit
Cover 3-Wire connector
-Main PBA : CN75
No.2(S/BLU) / No.7(RED) /
No.10(GRY)
Main PBA

CN 70,71

CN 40

CN 76

CN 50

Downloaded from www.Manualslib.com manuals search engine - 43/47 -


Tip 9-2. Inspect cooling power (※ Must select “Power
Freeze” first)
※ Do not off the power  Measure self diagnosis test
inspection on “TIP 9-1”
Step 1
Press Display “Lighting”+ “Energy Saver” Key for 8
sec at the same time.
- Press until all LEDs are Blinking and “DingDong”
sound appear

※ When the Error occur  Move to TIP 2-4


- When there is no problem inspect Step 2
Step 2 (Inspect Comp operation)
① Press Display “Freezer” for 3sec to being
“Power Freeze”.
※ Setting temperature satisfaction &
defrost performance Comp Off.
(When COMP operate again after 7 min off)

② Inspect the backside Comp’s operation.


(Check operation with touching comp with
hand)

- When Comp doesn’t operate Check Step


3
- When Comp operates  Check Step 6
Step 3 (Inspect Comp Wire )

① Inspect backside Unit left-side Comp Wire


Connector assembly problem
② After disassemble the Comp left Relay Cover Connector
and inspect OLP & PTC-Relay separation
separation
③ Inspect changing of PTC-Relay Wire
- Sub Coil left PNK, Main right S/BLU

Relay separation

Normal Changed PTC Relay


Next Page
Downloaded from www.Manualslib.com manuals search engine - 44/47 -
Step 4 (Comp single product operation failure)

① Inspect rotating failure by Comp Coil cutting


- Measure Common + Sub resistance
- Measure Common + Main resistance
Normal : 1~50 Ω
Failure : Open ∞ Ω
Step 5 (Comp Relay failure)

① Inspect power supply Line


- Comp operate condition is normal : AC
100~125 V
- Failure : Non applying AC voltage (Inspect
power line)
② Inspect Comp OLP(Over Load Protection)
- Normal : applying an electric current
0~1 Ω
- Failure : Open ∞ Ω
③ Inspect PTC Relay
- Normal: 0.8~1.4 KΩ
- Failure : Open ∞ Ω

Step 6 (Gas Leak Failure)

① Comp operates, but if temperature of Comp-


dome & Pipe-Condenser is not high, repair
cycle shield system repair because of gas
leak & Clogged failure.
Step 4 (When C-Fan is failure) .
① When C-Fan operation or “FG” Signal failure,
Comp will stop after 60 min.
※ Check “FG” failure through self-diagnosis
test even the fan rotates.

Inspect
Connector

Downloaded from www.Manualslib.com manuals search engine - 45/47 -


Tip 9-3. Inspect EVAP DEFROST BUILD
※ Do not off the power and operate self-diagnosis test to“TIP 5-1”
first.
 Must check the forced defrost operation after defrost repairing.
Step 1

Press Display “Lighting”+ “Energy Saver” Key for


8sec at the same time until “Dingdong” sound
appears
※ when the Error occurs Measure to move
TIP 5-1.
Defrost
- When there is no ERROR, DEFROST ERROR  Error
Check Step2
Step 2
① Disassemble EVAP COVER EVAP-FRE FRONT
& COVER Multi.

② Melt the right connector with steamer and


disassemble the cover.

Step 3 HEATER
& BIMETAL
① Measure BROWN WIRE resistance.
- Normal part : 35~60 Ω
- Failure part : Open or 0 Ω
 Replace HEATER & BIMETAL OPEN
because it is failure.
Step 4

① When DEFROST SENSOR part is freezing,


replace it because it is the failure of Sensor.

Step 5

① There is no freezing on bottom and DEF-


SENSOR and top middle part has freezing
-Move DEF-SENSOR location to center of
pipe.
BIMETAL
MOVE

Downloaded from www.Manualslib.com manuals search engine - 46/47 - Next Page


Step 6

① When EVAP BOTTOM is freezing only


- improve DRAIN freezing.

② Check Drain hole blocking with remove


freezing with STEAMER.
(Remove DRAIN freezing and foreign
substance)

③ Bending the HATER to bottom with hand.


- DRAIN HOLE Should be closed.
★ HEATER can not contact to PLATE.
LED ALL OFF
Step 7 (Total inspection after defrost repairing)

① Check Heater operation with forced defrost


operation after complete repairing. ①Forced
Press “Lighting”+ “Fridge” at the same time operation
to make ALL LED OFF and operate forced (LED Full On)
defrost with pressing “Fridge” key 2times. ↓
②Forced defrost
 Check heater(Brown-wire) AC voltage ↓
supplying when the “beep” sound appears. ③ OFF

② Off with same way if there is no problem.

Step 8 Inspect MAIN PBA CN70 No.5


① When there is no AC power supplying, (BRN)+CN71 No.1(ORG)
inspect MAIN PBA and CONNECTOR OPEN .
② Replace Main PBA if there is no problem. - LINER CONNECTOR BROWN
2WIRE

Downloaded from www.Manualslib.com manuals search engine - 47/47 -


Tip 10-1. Inspect R TOO COLD

Check Point Inspect COVER DAMPER

Step 1

① Disassemble the R ASSY COVER DAMPER.

R-Sensor
Damper
Damper

Step 2

① Inspect the location fixing condition of R-


SENSOR
- TOO COLD occurs when separate or cover
the front with protection vinyl.

② Inspect DAMPER
- Inspect Damper Closing condition when
disassemble

※ Close condition when open R door after


power restarting on CONNECTOR condition.

- Failure when it is opened


 Replace INS-DAMPER.

Downloaded from www.Manualslib.com manuals search engine - 48/47 -