CPWD Specs 2009 V2-39-41 F PDF
CPWD Specs 2009 V2-39-41 F PDF
CPWD Specs 2009 V2-39-41 F PDF
EL
FE
safe from dust. When the Paint has been used, the containers shall be washed with turpentine and wiped dry
with soft clean cloth, so that they are clean, and can be used again.
13.23.6 Measurements
13.23.6.1 The length and breadth shall be measured correct to a cm. The area shall be calculated in
sqm (correct to two places of decimal), except otherwise stated.
13.23.6.2 Small articles not exceeding 10 sq. decimetre (0.1 sqm) of painted surfaces where not in
conjunction with similar painted work shall be enumerated.
13.23.6.3 Painting upto 10 cm in width or in girth and not in conjunction with similar painted work shall
be given in running metres and shall include cutting to line where so required.
Note : Components of trusses, compound girders, stanchions, lattices and similar work shall, however,
be given in sq. metres irrespective of the size or girth of members. Priming coat of painting shall
be included in the work of fabrication.
13.23.6.4 In measuring painting, varnishing, oiling etc. of joinery and steel work etc. The coefficients as
indicated in following tables shall be used to obtain the area payable. The coefficients shall be applied to
the areas measured flat and not girthed.
TABLE 13.1
Equivalent Plain Areas of Uneven Surface
S. Description of work How measured Multiplying
No. coefficients
1 2 3 4
I. Wood work doors, windows Etc.
1. Panelled or framed and braced Measured flat (not girthed including) 1.30 (for each side)
doors, windows etc.
2. Ledged and battened or ledged, Chowkhat or frame, Edges, chocks, - do -
battened and braced doors, cleats, etc. shall be deemed to be
windows etc. included in the item.
3. Flush doors etc. -do- 1.20 (for each side)
4. Part panelled and part glazed or -do- 1.00 (for each side)
gauzed doors, window etc.
(Excluding painting of
wire gauze portion)
5. Fully glazed or gauzed doors, -do- 0.80 (for each side)
windows etc. (Excluding painting
of wire gauze portion)
6. Fully venetioned or louvered -do- 1.80 (for each side)
doors, windows etc.
7. Trellis (or Jaffri) work one way or Measured flat overall, no deduction 2 (for painting all over)
two way shall be made for open spaces, sup-
porting members shall not be mea-
sured separately
8. Carved or enriched work Measured flat 2 (for each side)
9. Weather boarding Measured flat (not girthed supporting 1.20 (for each side)
frame work shall not be measured
separately
10. Wood shingle roofing Measured flat (not girthed) 1.10 (for each side)
III. General
19. Expanded metal, hard drawn Measured flat overall; no deduction 1 (for Paint all over)
steel wire fabric of approved shall be made for open spaces;
quality, grill works and gratings supporting members shall not be
in guard bars, balustrades, railing measured separately
partitions and MS Bars in
windows frames.
20. Open palisade fencing and -do- 1 (for Paint all over)
gates including standards, (see note No. 12)
braces, rails stays etc. in timber
or steel
21. Corrugated iron sheeting in -do- Measured flat (not girthed) 1.14 (for each side)
roofs, side cladding etc.
22. AC corrugated sheeting in roofs, -do- 1.20 (for each side)
side cladding etc.
23. AC semi corrugated sheeting in
roofs, side cladding etc. or -do- 1.10 (for each side)
Nainital pattern using plain sheets
24. Wire gauze shutters including -do- 1.00 (for each side)
painting of wire gauze
13.23.6.5 Width of moulded work of all other kinds, as in hand rails, cornices, architraves shall be mea-
sured by girth.
13.23.6.6 For trusses, compound girders, stanchions, lattice girders, and similar work, actual areas will
be measured in sq. metre and no extra shall be paid for painting on bolt heads, nuts, washers etc. even
when they are picked out in a different tint to the adjacent work.
13.23.6.7 Painting of rain water, soil, waste, vent and water pipes etc. shall be measured in running
metres of the particular diameter of the pipe concerned. Painting of specials such as bends, heads,
branches, junctions, shoes, etc. shall be included in the length and no separate measurements shall be
taken for these or for painting brackets, clamps etc.
13.23.6.8 Measurements of wall surfaces and wood and other work not referred to already shall be
recorded as per actual.
13.23.6.9 Flag staffs, steel chimneys, aerial masts, spires and other such objects requiring special
scaffolding shall be measured separately.
13.23.7 Precautions
All furnitures, fixtures, glazing, floors etc. shall be protected by covering and stains, smears, splashings, if
any shall be removed and any damages done shall be made good by the contractor at his cost.