General Notes & Specifications
General Notes & Specifications
(CIVIL WORKS)
NAME OF PROJECT:
CONSTRUCTION OF 2 UNITS SHUTDOWNERS BARRACKS
PREPARED BY:
CONFORMED:
VICTORINO C. SANTOS
OWNER/MANAGER
V.M. JHEK BUILDERS
1
CIVIL /STRUCTURAL
GENERAL NOTES AND SPECIFICATIONS
1. GENERAL
1.1. THE CONTRACTOR SHALL VERIFY ALL THE DIMENSIONS & CONDITIONS AT THE
SITE AND SHALL NOTIFY THE CONTRACTING OFFICER OF THE DISCREPANCIES
ARISING BETWEEN THE ACTUAL SITE CONDITIONS AND INFORMATIONS SHOWN
ON THE DRAWINGS BEFORE PROCEEDING WITH THE WORK. THIS SHALL INCLUDE
THE LOCATIONS AND DIMENSIONS OF GROOVES, REGLETS, SLEEVES, CURBS,
OPENINGS, EMBEDDED OR ATTACHED ITEMS, ETC. (REFER TO THE ARCHITECTURAL,
MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS).
1.2. ALL DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE SHOWN ON PLANS,
SECRTIONS, ANAD OR DETAILS. NOTES AND DETAILS ON DRAWINGS SHALL TAKE
PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS.
1.6. THE CONTRACTOR SHALL TAKE ALL STEPS NECESSARY TO ENSURE THE PROPER
ALIGNMENT OF THE STRUCTURE AFTER THE INSTALLATION OF ALL STRUCTURAL
AND FINISH MATERIALS.
1.7. TYPICAL DETAILS AND GENERAL NOTES SHALL APPLY TO ALL PARTS OF THE JOB
UNLESS OTHERWISE SHOWN ON THE PLANS.
2
2.2. ASSOCIATION OF STRUCTURAL ENGINEERS OF THE PHILIPPINES (ASEP)
EARTHQUAKE DESIGN MANUAL VOLUME 1
2.3. STRUCTURAL DESIGN DATA AND SPECIFICATIONS 6TH EDITION (A.B. CARILLO)
2.5. STANDARD SPECIFICATIONS FOR PUBLIC WORKS AND HIGHWAYS VOLUME II &
VOLUME III 1995 EDITION
2.6. STANDARD SPECIFICATIONS FOR PUBLIC WORKS AND HIGHWAYS VOLUME II 2012
EDITION
6. MATERIAL PROPERTIES
6.1. CONCRETE
6.1.3 LOCALLY AVAILABLE COARSE AND FINE AGGREGATES THAT ARE FREE
FROM ANY IMPURITIES SHALL BE USED.
3
6.1.4 CONCRETE MUST BE PROPORTIONED TO PROVIDE ADEQUATE
WORKABILITY AND PROPER CONSISTENCY TO PERMIT CONCRETE TO BE
WORKED READILY INTO THE FORMS AND AROUND REINFORCEMENT.
6.1.5 USE CLASS “A” FOR ALL STRUCTURAL MEMBERS THAT REQUIRES
CONCRETE AND CLASS “B” FOR MASONRY WORKS
7.b. ALL REINFORCING STEEL BARS SHALL BE CLEAN OF RUST, GREASE OR OTHER
MATERIALS TO IMPAIR BOND.
7.c. UNLESS OTHERWISE SHOWN ON THE PLANS, REINFORCING STEEL BARS SHALL BE
DEFORMED AND HAVE APPROVED QUALITY COMPLYING THE A.S.T.M.
SPECIFICATIONS
7.d. USE 16 mm Ø STEEL BARS FOR SLAB MAIN REIFORCEMENTS AND 12 mm Ø FOR
TEMPERATURE BARS
A. BEAMS AND FOOTING TIE BEAMS; TOP AND BOTTOM BARS SHALL NOT BE
SPLICED WITHIN THE COLUMN OR WITHIN A DISTANCE OF TWICE THE
MEMBER DEPTH FROM THE FACE OF THE COLUMN. AT LEAST TWO EXTRA
STIRRUP TIES SHALL BE PROVIDED AT ALL SPLICES. THE SPLICE LENGTH SHALL
NOT BE LESS THAN 1.3 x THE DEVELOPMENT LENGTH (L D), BUT NOT LESS THAN
300 mm
B. COLUMN; LAP SPLICES SHALL BE MADE WITHIN THE CENTER HALF OF THE
COLUMN HEIGHT, AND THE SPLICE SHALL NOT BE LESS THAN 30 BAR
DIAMETER WELDING OR THE USE OF APPROVED MECHANICAL DEVICES MAY
PERMITTED PROVIDED NOT MORE THAN ALTERNATE BARS ARE WELDED OR
SPLICED AT ANY LEVEL AND THE MINIMUM VERTICAL DISTANCE BETWEEN
TWO ADJACENT BAR SPLICES SHALL BE 600 mm
C. CMU WALLS; VERTICAL BARS SHALL BE SPLICED AT THE TOP OF WALL FOOTING
OR FOOTING TIE BEAMS AND AT THE BOTTOM OF RC LINTEL BEAM
4
7.j. UNLESS INDICATED OTHERWISE, ALL BEAMS TERMINATING AT THE COLUMN
SHALL HAVE TOP AND BOTTOM BARS EXTENDING TO THE FAR FACE OF THE
COLUMN, TERMINATING IN A STANDARD 90 HOOK, LENGTH OF ANCHORAGE
SHALL NOT BE LESS THAN 600 mm
8. METALS
8.1. ALL STRUCTURAL STEEL SHALL HAVE A MINIMUM YIELD STRENGTH F y = 250 MPa
(A-36)
8.4. ALL STEEL TRUS MEMBERS SHALL BE ANGULAR WITH SIZES AS INDICATED ON THE
PLANS THAT CONFORMS TO THE AISC SPECIFICATIONS
8.5. NO STEEL SHALL BE FABRICATED OR ERECTED UNTIL SHOP DRAWINGS HAVE BEEN
APPROVED BY THE STRUCTURAL ENGINEER
8.6. THE PARTS OF THE STEEL TRUSS SHALL BE ACCURATELY ASSEMBLED AS SHOWN
ON THE PLANS AND ANY MATCH MARKS SHALL BE FOLLOWED
8.7. ALL SHOP AND FIELD WELDING SHALL BE IN ACCORDANCE WITH AWS AND
PERFORMED BY QUALIFIED WELDERS.
5
9.2 CONCRETE HOLLOW BLOCKS SHALL BE REINFORCED WITH ‘THRU-LOK’ OR OTHER
APPROVED MASONRY REINFORCEMENT EVERY THIRD COURSE AND SHALL BE
REINFORCED VERTICALLY WITH 10 mm Ø BARS AT 60 mm ON CENTERS
9.3 UNLESS INDICATED OTHERWISE, CMU IN THIS WORKS SHALL HAVE A MINIMUM
ULTIMATE COMPRESSIVE STRENGTH @ 28 DAYS OF f m = 2.40 MPa
9.4 UNLESS INDICATED OTHERWISE, ALL CMU SHALL BE FILLED SOLIDLY WITH GROUT,
CONCRETE GROUT SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 13.70
MPa (2000 psi) @ 28 DAYS