Friend of Kim

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

GENERAL NOTES

03 All dimensions are in mm unless otherwise specified.


Drawings are not to be scaled,only use figured dimensions.

The contractor must check and verify all dimensions before


11,800 commencement of work.

150 1,400 150 2,800 150 4,000 150 2,850 150 All openings to have a permanent ventilation except wc &sh
internal dooors.
1,550 800 1,500 800 550 2,400 1,900 2,000 300
All soils underslab around and under foundation to be
poisoned for termite control.

150
For all R.C works.refer to structural engineer's details.
600
150

FRONT ELEVATION 01.

1,350

1,200
2,800
Depth of foundation to be determined on site to S.E
approval.
2,000

Bedroom
2,950

03 All walls less than 150 mm thick to be reinforced with hoop

150
470
4,000 2,850 iron at every alternate course.
500

2,650
Master
150

All adjacent R.C work and masonry wall to be tied with hoop

2,650

2,000
Bedroom iron at every alternate course.
300

Sitting Room

4,300
1,200

900

150
1,200

1,500
PLUMBING
04

02
780
8,950

8,950
1,200 150 1,200
150

450

All plumbing and drainage to comply with relevant local

1,500
authority.

900
1,500
1,200

Shower
900

1,200

tray Shower
wc tray

100 450
whb
SVP denotes soil vent pipes to be provided at the head of
300

150
the drainage system.
150

150 1,700
400

1,400
Entry Minimum slope in drain s pipe to be 1:100.

1,700
Bedroom Kitchen
Porch
X 02
4,000

X
2,850
2,000

All underground foul and waste drain pipe shall be upvc to


2,850

500 2,000 500 900 100

comply with BS 5255.

350

1,000
Kitchen Yard
1,000
600
150

1,150

150
100 300

SIDE ELEVATION 02
250 350 400 150 250
1,550 800 1,500 650 1,000 1,100 1,050 1,000 900 450
150
150 1,400 150 2,800 150 4,000 150 1,200 1,500 150
11,800
PROJECT TITLE:

01 Proposed 3-Bedroom Residential House.

GROUND FLOOR PLAN CLIENT

SIGNATURE .................................................

DRAWING TITLES:
28 gauge ridge cap on 200 x 25 ridge board
28 gauge g.c.i sheet on 50x50 mm purlins on 75x50 mm common REAR ELEVATION 03. Architectural
Ground Floor Plan
rafters placed at 900 mm centres on 100x50 mm wall plate with
Elevations
celotex soft lining underneath to SE's detail and approval and
200x25 mm thick wrot timber fascia board.
300 mm by 150 mm Vibrated RCC Beam
Glass panes bedded on metal grills SCALE:

Well burnt brick masonry walling jointed and 1:100


bedded on cement sand mortar (1:6) and reinforced
with hoop iron and 25 mm thick rough cast plaster P.O Box 1244-20200
finish below all windows. Nairobi
web: www.link350.com
200mm thick natural stone masonry walling jointed and email address:
bedded on cement sand mortar (1:6) and reinforced with [email protected]
hoop iron on600x200 mm thick(1:2:4) v.r.c. strip [email protected]

foundation on 50 mm thick concrete blinding to strip


[email protected]
foundation (1:4:8) Tel: (+254) 729 578 910
BRC mesh A142 on 100 mm thick v.r.c ground floor slab (1:2:4) on Link 350 Projects Ltd
1000 gauge polythene dpm on 50 mm thick well compacted and project management.architectural.structural.services
watered murram blinding on 250 mm thick hand packed and well
compacted hardcore filling.
DRAWN CHECKED:

SECTION X-X Bernard Kirui

SIDE ELEVATION 04 DATE February 2018


GSPublisherEngine 0.16.100.100

You might also like