0% found this document useful (0 votes)
119 views1 page

1.51 Design of Steel Structures MIT Department of Civil and Environmental Engineering Spring Semester, 1999

This document contains examples of calculating the axial compression design strength of steel columns made of A36 and A572 Grade 50 steel. It provides examples of unbraced and braced columns, and selects the lightest steel section that can support given load cases. The final example calculates the design of a specific column supporting dead and live loads.

Uploaded by

Osama Maher
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
119 views1 page

1.51 Design of Steel Structures MIT Department of Civil and Environmental Engineering Spring Semester, 1999

This document contains examples of calculating the axial compression design strength of steel columns made of A36 and A572 Grade 50 steel. It provides examples of unbraced and braced columns, and selects the lightest steel section that can support given load cases. The final example calculates the design of a specific column supporting dead and live loads.

Uploaded by

Osama Maher
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

1.

51 Design of Steel Structures MIT Department of Civil and Environmental Engineering Spring Semester, 1999

Example 3.4 Find the axial compression design strength for a 40 ft A36 steel W1265
section with no bracing. Compare this strength with that of the same column made out of
A572 Grade 50 steel (Fy = 50 ksi).

Example 3.5 Repeat Example 3.4 for the case of bracing at mid-length.

Example 3.6 A 16 ft column with pinned ends in a braced frame is to support a compression
load. The dead load is 95 kips and the live load is 100 kips. Select the lightest section of A36
steel. Choose among W8, W10 and W12 sections.

Example 3.7 A 30 ft column with pinned ends in a braced frame is to support a compression
load. The column has an additional lateral support in the weak-axis direction at mid-height.
The dead load is 245 kips and the live load is 110 kips. Select the lightest section of A36 steel.
Choose from W8, W10, and W12 sections.

Example 3.8 Design the column shown below. The dead load (PD ) is 198 kips and the live
load (PL ) is 164 kips. In the strong axis, the column is rigidly connected to the girders, and in
the weak axis it is flexibly connected to the beams. Using A36 steel find the lightest member
among W12 sections. The girders are W1636 sections with 40 ft spans. The columns are all
12 ft high.

Design this column.