Phase Out in Progress See Next 6 Pages Please See RA 10 515 PV7 V Ane Pump
Phase Out in Progress See Next 6 Pages Please See RA 10 515 PV7 V Ane Pump
Phase Out in Progress See Next 6 Pages Please See RA 10 515 PV7 V Ane Pump
95
K4752-7
– low hysteresis
– short control times
Type V4/20
– air bleed standard
– test point
– can also be supplied as combination pump
P r o g ress
Out i n
Phase ext 6 Pages
F90003
see R A
Please Vane Pump
PV7…
testpoint
F90005
Type V4/Testpoint
K4751-7
Type V4 + V4-Combination
1
RA 10 460/03.95
Ordering code
Streamlining the Model Code Types of the 1PV2V4 variable Vane Pump
After consuming the parts in stock, the outlined versions are no longer available.
For replacements, please review corresponding footnotes.
1 PV 2 V4 R 5*
2
RA 10 460/03.95
Current version, V4
Example: V4/20
Future supply, V4
Example: V4/20
• No airbleed
• Shaft with Thru-Drive Standard
(~1" overall length increase)
3
RA 10 460/03.95
Technical data (for operation outside these parameters, please consult us!)
General
Construction Variable vane pump
Type V4
Mounting Flange mounting
Connections Threaded or flanged, dependent on size of unit and model designation
Installation position Optional, preferrably horizontal (see page 8)
Shaft loading Radial and axial forces cannot be accepted
Direction of rotation Clockwise (viewed on shaft end)
Speed range n min bis n max rpm 900 to 1800
Size 20 32 50 80 125
Drive power (n = 1750 rpm) Peff HP 13.8 23.5 37.34 51.8 71.7
(kW) (10.3) (17.5) (27.8) (38.6) (64)
Torque T max lb-ft 166.69 216.84 376.16 376.16 723.52
(Nm) (228) (294) (510) (510) (1330)
Weight (with pressure control C1) m lbs. 51.79 68.32 94.33 123.42 211.58
(kg) (23.5) (31) (42.8) (56) (98)
Hydraulic
Size 20 32 50 80 125
Displacement Veff in3 1.26 2.11 3.37 5.05 7.79
(cm3) (20.7) (34.5) (55.2) (82.8) (127.6)
Max. flow Q GPM 9.25 16.9 24.3 38 57.7
at n = 1750 min-1; p = 145 PSI (10 bar) (L/min) (35) (64) (92) (144) (218)
4
RA 10 460/03.95
B1 B2
B7
1
P
D1/T1
øD6
H2
3 øD
4
H3
H4
0.315 (8) A/F
0.945 (24) A/F
H1
S D2/T2
2
B3
X
øD11
10
D8/T8 13
0.67 (17) A/F
L12 8 L14
B6 5
0.118 (3) A/F
4
11
D9/T9
L13
max.
(L2)
L11 L3
a) L8
b) L15
L1
L4
9 L10
D3/T3
L6
B4 L5 L7 L9
7
6
øD5
12
B5
øD7
1 A
* shown pump: 1 PV 2 V4-3X/80 RW 16 ... C 3 –16 N 1
A/F = Across Flats
5
RA 10 460/03.95
S2
Type code ..A.. 9 without setting screw for
Clockwise rotation: adjusting displacement
reduces replacement 10 Gauge port (remove plug)
Counter-clockwise rotation: 11 Thread for lifting lugs
D9 increases displacement Size 50: M8; 0.511 (13) deep
1/2"-13 UNC 4 Deadhead pressure setting Size 80: M8; 0.511 (13) deep
Size 80; 1.1 (27) deep via allen head adjustment screw Size 125: M10; 0.708 (18) deep
Size 125; 0.6 (16) deep 0.118 (3) A/F 12 a)
Pressure line
Ordering code see controllers b)
Suction line
View Y 2.748 Clockwise rotation: (180° opposite)
Only size 125 (69.8) increases pressure 13 Space required for removal
(SAE 1-1/2") Counter-clockwise rotation: of key
reduces pressure
(35.7)
1.406
V4-1X/20 6.594 3.228 1.654 2.047 0.354 1.102 0.433 0.669 5.472 0.629 8.543 1.771 1.102 — —
(167.5) (82) (42) (52) (9) (28) (11) (17) (139) (16) (217) (45) (28)
6.751 3.385 2.283 2.696 0.393 1.259 0.472 0.826 5.905 0.590 8.661 1.771 1.259
V4-2X/32 (171.5) (86) (58) (68.5) (10) (32) (12) (21) (150) (15) (220) (45) (32) — —
7.618 4.251 2.283 2.677 0.354 1.437 0.492 0.905 7.401 0.708 9.566 1.771 1.437
V4-2X/50 — —
(193.5) (108) (58) (68) (9) (36.5) (12.5) (23) (188) (18) (243) (45) (36.5)
7.854 4.488 2.276 2.677 0.354 1.673 0.629 1.259 7.992 0.708 9.803 1.771 2.047 3.063 1.689 SAE
V4-3X/80
(199.5) (114) (57.8) (68) (9) (42.5) (16) (32) (203) (18) (249) (45) (52) (77.8) (42.9) 2"
V4-3X/125 8.720 5.669 3.228 3.641 0.354 2.244 0.984 1.535 9.409 1.181 10.66 1.771 2.244 3.500 2.004 SAE
(221.5) (144) (82) (92.5) (9) (57) (25) (39) (239) (30) (271) (45) (57) (88.9) (59.9) 2-1/2"