Cyclone Design

The document provides specifications for a cyclone separator, including: - Gas flow rate of 6.73 m3/s - Inlet velocity of 20 m/s and diameter of 1.6 m - Dimensions for the inlet and outlet - Heights for different parts of the cyclone - Densities of the fluid and particles - An equation for calculating pressure drop across the cyclone

Uploaded by

David Lambert
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
315 views1 page

Cyclone Design

The document provides specifications for a cyclone separator, including: - Gas flow rate of 6.73 m3/s - Inlet velocity of 20 m/s and diameter of 1.6 m - Dimensions for the inlet and outlet - Heights for different parts of the cyclone - Densities of the fluid and particles - An equation for calculating pressure drop across the cyclone

Uploaded by

David Lambert
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 1

Laju volumetrik gas buang,Q 6.

73 m3/s
Kecepatan limier inlet, vi 20 m/s 65.6168 ft/s
Luas penampang inlet,A 0.3363341065 m2
Diameter cyclone 1.6 m =sqrt(8*A)

DIMENSI INLET
a 0.8 m
b 0.41 m, harus lebih kecil 0.45109

DIMENSI OUTLET
Diameter, De 0.74 m
Panjang dari puncak, 1.03 m

Tinggi cylone bag silinder, h 3.28


Tinggi cyclone bag kerucut, H 3.28
Diameter utk pengeluaran partik 0.41

PERHITUNGAN PRESSURE DROP

Densitas fluida, Df 0.5587664643 kg/m3 0.034882 lb/ft3


Densitas partukel, Dp 100 kg/m3 6.242732 lb/ft3
Pressure Drop =0.003*Df*vi *K*(a*b/De )
2 2

K= 16
4.4500133401 in H2O
113.0303388373 mmH2O