Software Update: Checking The Software Version
Software Update: Checking The Software Version
Software Update: Checking The Software Version
This document contains instructions for updating the system software of the Kawai MP11 professional stage piano.
Please read these instructions thoroughly before attempting to perform the software update.
ho
If the Program version number is greater than or equal to the
ld
update version, no further action is necessary.
* Turn the instrument OFF and ON to return to normal operation.
If the Program version number is lower than the update version, Program
version
please continue to follow the instructions below.
ho
ho
ld
ld
ld
These additional options allow greater control over half-pedalling MIDI values, and may be useful when
playing software piano packages, especially as the HalfPedVal can be set independently for each Zone.
Please experiment with each setting to find the most natural half-pedal behaviour.
Normal 0 ~ 127
High 0, 64 ~ 127
– Changed: If metronome is enabled when using the Overdub function, only the count-in will be heard.
– Changed: ‘Volume’ parameter in 3.Sound menu replaced with ‘[C]MasterVol.’, allowing total SETUP volume to be adjusted.
– Changed: Zone volume value pop-up shown when operating a zone volume fader.
– Changed: Metronome Volume is now stored to SETUP memories. Moreover, when a rhythm pattern is running, selecting
a SETUP with a different stored rhythm will not change the volume of the playing rhythm pattern.
– Changed: Default AudioRecGain value is now set to +9 dB.
– Fixed: Occasional glitches/errors when recording to large capacity USB memory devices in WAV format.
– Fixed: Rare phenomenon whereby pedal assigned to EFX2:Rotary Slow/Fast function would not toggle correctly.
– Fixed: Strange velocity behaviour of piano sounds when reducing the Cut-off parameter.
– Improved: When connecting a USB device, pop-up message is only shown when accessing USB-related functions.
– Improved: Reduced wait times when using large capacity USB memory devices.
– Improved: Right Pedal Calibration function in SYSTEM:Pedal menu has been improved.
SYSTEM:Pedal HalfAdjust parameter is also taken into consideration when calibrating.
– Improved: Reduced ‘jumping’ noise that could sometimes occur when using MIDI recorder’s A-B repeat function.
– Improved: Reduced ‘jumping’ noise that could sometimes occur when operating knobs controlling EFX, AMP, or EQ.
– Improved: Various other operation/display improvements.
Software Update (MP11)