Wawan Dwi Prasetiyo performed a routine preventative maintenance (PM) on a hematology analyzer (XP-100, serial number B2315) located at Puskesmas Jogonalan 2 in Klaten, Central Java. The PM involved cleaning various components of the pneumatic, hydraulic, and mechanical systems and verifying that pressure, vacuum, and sensor readings were within normal ranges. After completing the checklist and testing samples, the analyzer was determined to be in good working order.

Uploaded by

tri
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
82 views5 pages

PT Saba Indomedika PM: National Diagnostic Distributors

Wawan Dwi Prasetiyo performed a routine preventative maintenance (PM) on a hematology analyzer (XP-100, serial number B2315) located at Puskesmas Jogonalan 2 in Klaten, Central Java. The PM involved cleaning various components of the pneumatic, hydraulic, and mechanical systems and verifying that pressure, vacuum, and sensor readings were within normal ranges. After completing the checklist and testing samples, the analyzer was determined to be in good working order.

Uploaded by

tri
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

PM

PT SABA INDOMEDIKA
No: #1358
National Diagnostic Distributors
Date: 31/05/18

Supported Detail Ticket Instrument Customer Detail

Support Name Ticket Type: Instrument Type: Customer Name:


Wawan Dwi Other - PM XP-100 Puskesmas Jogonalan 2, Klaten
Prasetiyo Code: Serial No: Customer Address:
Division: C/201804/0105 B2315 Desa Dompyongan, Kec.
Engineer Login Call Time: Contract Type: Jogonalan, Dompyongan,
Rating: 14:32 - 03/04/18 Sold Jogonalan, Kabupaten Klaten, Jawa
5 Start: Tengah 57452
Comment: 08:26 - 31/05/18 Doctor / PJ Lab:
trm ksh End: Customer Number:
10:24 - 31/05/18 Description
routine PM

PM Checklist

A) Pneumatic Tube

☑ 1) Check and clean compressor, replace piston rings if necessary.

☑ 2) Check tubing's for dirt and damages, replace if necessary.

☑ 3) Check tubing nipples.

B) Main Unit Pneumatic System

☑ 1) Check and clean the pressure and vacuum lines, change if necessary.

☑ 2) Check bellows unit, needle valve, related tubing and connector, clean if necessary.

☑ 3) Clean pressure and vacuum nipples.

☑ 4) Check Pressure (0.5 ± 0.07kg/cm²), adjust if necessary.

☑ 5) Check Vacuum (250 ± 10mmHg ), adjust if necessary.

☑ 6) Clean Vacuum Trap Chamber and check for cracks.

☑ 7) Check and Clean Orifice.

C) Main Unit Hydraulic


PM Checklist

☑ 1) Clean Waste Chamber

☑ 2) Clean Trap Chamber

☑ 3) Clean Rinse Cup assembly and mechanism.

☑ 4) Clean SRV assembly

☑ 5) Clean ASP Pipette.

☑ 6) Clean RBC/WBC Transducers and Chambers

☑ 7) Check on dirty and damaged tubing's.

☑ 8) Clean waste nipple (rear of analyzer)

D) Main Unit Adjustments

☑ 1) Clog adjustment for WBC and RBC Transducers

☑ 2) Adjustment of HGB Unit - Blank 2000 ± 100

☑ 3) Adjust Standard Sensitivity (W-MFV, R-MCV)

E) General

☑ 1) Perform background check.

☑ 2) Measure "eightcheck" in "QC Mode" and Analyse normal human blood sample, adjust if necessary.

☑ 3) Reset counter for WC, detector and SRV if replaced.

☑ 4) Check Printer & Keyboard

F) Counter

☑ 1) Total Counter

☑ 2) SRV

Notes

Main unit ready to use


Team Support Approved By

Started By: Wawan Dwi Prasetiyo Closed By: Khrisma Jatiajie


Team Support Approved By

Ended By: Wawan Dwi Prasetiyo Closed At: 14:32 - 03/04/18