Instrumentation Cable
Insulation: polyvinyl chloride in Fixed Position: 5 x cable overall The following constructions can be
accordance with UL 13 and UL 2250, diameter provided on special orders:
flame retardant, 105°C temperature During Installation: 8 x cable • Tinned copper conductors
rating. overall diameter • When increased mechanical,
chemical, or environmental
Insulation Shield (on shielded pair/ Specifications protection is required, cables can be
triad constructions): aluminum foil/ supplied with a continuously
polyester shield helically wrapped to corrugated aluminum armor and an
• Conductor rated 105°C 300V
provide 100% coverage with a tinned outer PVC jacket.
• Meets UL requirements for Type PLTC
copper drain wire that is two gauge • Interlocked aluminum armor with or
and ITC
sizes smaller than the circuit without an outer PVC jacket.
• Designated Type PLTC per NEC ART
conductors. • Direct Burial listed cable (when
725
ordered as ITC/DB)
• Designated Type ITC per NEC ART
Assembly: pairs/triads are cabled in • Conductors with alternate color /
727
concentric layers. In the case of identification codes
unshielded pairs/triads, they are • Alternate jacket colors
Product Features
cabled at staggered lengths to reduce
crosstalk.
• UL approved Type PLTC and ITC,
300V * Use in hazardous locations:
Overall cable shield: aluminum
• UL approved insulated conductors Please note that no investigation of
foil/polyester shield helically wrapped
• Cables pass UL 1685 and IEEE 383 these cables has been performed
to provide 100% coverage with a
vertical fire tests at 70,000 BTU/hr regarding the transmission of gases or
tinned copper drain wire that is the
• Temperature rating 105°C dry vapours through the core. When these
same size as the circuit conductors,
• Sunlight and moisture resistant jacket cables are used in hazardous locations
with the exception of single pair/triad
• For use within Class 1 Division 2 and they should be sealed properly as
constructions where the drain wire is
Class 2 Division 2 Hazardous required by the NEC.
two gauge sizes smaller than the circuit
Locations, and Intrinsically Safe
conductors.
applications as permitted by NEC
ART 392, 501, 502, 504 and 505.*
1-866-6-NEXANS
3
Instrumentation Cable
Note: Specifications and weights shown are nominal and subject to standard industry tolerances.
1-866-6-NEXANS
4
Instrumentation Cable
Note: Specifications and weights shown are nominal and subject to standard industry tolerances.
1-866-6-NEXANS
5
Instrumentation Cable
Note: Specifications and weights shown are nominal and subject to standard industry tolerances.
1-866-6-NEXANS
6
Instrumentation Cable
Note: Specifications and weights shown are nominal and subject to standard industry tolerances.
1-866-6-NEXANS
7
Instrumentation Cable
1-866-6-NEXANS
8
Instrumentation Cable
Note: Specifications and weights shown are nominal and subject to standard industry tolerances.
1-866-6-NEXANS
9
Instrumentation Cable
Note: Specifications and weights shown are nominal and subject to standard industry tolerances.
1-866-6-NEXANS
10
Instrumentation Cable
631309 2 16(7w) 15/4 .38/.10 47 1.19 .480 12.19 127 189 129 59
631317 3 16(7w) 15/4 .38/.10 47 1.19 .514 13.06 145 216 183 83
631325 4 16(7w) 15/4 .38/.10 62 1.57 .590 14.99 201 299 237 108
631333 6 16(7w) 15/4 .38/.10 62 1.57 .694 17.63 270 402 350 159
631341 8 16(7w) 15/4 .38/.10 62 1.57 .763 19.38 344 512 454 206
———— 10 16(7w) 15/4 .38/.10 82 2.08 .937 23.80 455 677 537 244
697508 12 16(7w) 15/4 .38/.10 82 2.08 .966 24.54 521 775 671 304
697516 16 16(7w) 15/4 .38/.10 82 2.08 1.072 27.23 660 982 888 403
680405 20 16(7w) 15/4 .38/.10 82 2.08 1.190 30.23 801 1192 1105 501
697524 24 16(7w) 15/4 .38/.10 82 2.08 1.323 33.60 944 1405 1322 600
680413 36 16(7w) 15/4 .38/.10 92 2.34 1.536 39.01 1370 2039 1972 894
693564 50 16(7w) 15/4 .38/.10 112 2.84 1.849 46.96 1914 2848 2731 1239
Note: Specifications and weights shown are nominal and subject to standard industry tolerances.
1-866-6-NEXANS
11
Instrumentation Cable
———— 2 16(7w) 15/4 .38/.10 47 1.19 .509 12.93 156 232 170 77
631390 4 16(7w) 15/4 .38/.10 62 1.57 .624 15.85 253 377 320 145
627133 8 16(7w) 15/4 .38/.10 62 1.57 .810 20.57 444 661 619 281
———— 10 16(7w) 15/4 .38/.10 82 2.08 .993 25.22 581 865 769 349
627141 12 16(7w) 15/4 .38/.10 82 2.08 1.024 26.01 671 999 919 417
688648 16 16(7w) 15/4 .38/.10 82 2.08 1.138 28.91 858 1277 1218 552
———— 20 16(7w) 15/4 .38/.10 82 2.08 1.265 32.13 1046 1557 1518 689
683029 24 16(7w) 15/4 .38/.10 82 2.08 1.408 35.76 1238 1842 1817 824
———— 36 16(7w) 15/4 .38/.10 82 2.08 1.615 41.02 1777 2644 2715 1232
———— 50 16(7w) 15/4 .38/.10 112 2.84 1.967 49.96 2523 3755 3764 1707
Note: Specifications and weights shown are nominal and subject to standard industry tolerances.
1-866-6-NEXANS
12
Instrumentation Cable
Electrical Properties
1-866-6-NEXANS
13
Instrumentation Cable
1-866-6-NEXANS
14
Instrumentation Cable
The cross-reference to Belden part numbers are provided for informational purposes only, and Nexans makes no
representation or warranty, either express or implied, as to the accuracy of any such cross-reference. Belden is not in any way
associated with Nexans. Belden is a registered trademark of Belden Wire & Cable Company.
1-866-6-NEXANS
15
Instrumentation Cable
1-866-6-NEXANS
16
Instrumentation Cable
The cross-reference to Belden part numbers are provided for informational purposes only, and Nexans makes no
representation or warranty, either express or implied, as to the accuracy of any such cross-reference. Belden is not in any way
associated with Nexans. Belden is a registered trademark of Belden Wire & Cable Company.
1-866-6-NEXANS
17
Instrumentation Cable
Product Data
Test Method Insulation Jacket
Temperature Rating UL 2250 and UL Subject 13 105°C 90°C
Copper Data
AWG Stranding Diameter AWG Stranding Diameter
inches mm inches mm
22 Solid .0254 .645 22 7 × .0100" .0300 .762
20 Solid .0320 .813 20 7 × .0121" .0360 .914
19 Solid .0359 .912 19 7 × .0142" .0430 1.092
18 Solid .0403 1.024 18 7 × .0152" .0456 1.158
16 Solid .0508 1.290 16 7 × .0192" .0576 1.463
14 Solid .0640 1.626 14 7 × .0242" .0726 1.844
12 Solid .0808 2.052 12 7 × .0305" .0915 2.324
1-866-6-NEXANS
18
WARNING NOTICE
CORROSIVE
Emission of acid gases may corrode
metal in the vicinity, such as sensitive
instruments and reinforcing rod in
concrete.