0% found this document useful (0 votes)
456 views1 page

Docslide. Limpet Coil Calculation

This document contains calculations for determining the minimum thickness of a pipe used to withstand an internal design pressure. It lists the key parameters such as inside pipe radius, shell thickness, design pressure, allowable material stresses, and uses formulas from ASME boiler and pressure vessel codes to calculate the required pipe thickness. The results show that the permissible pipe pressure is greater than the design pressure, indicating the pipe thickness is sufficient.

Uploaded by

Adrian Stoicescu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
456 views1 page

Docslide. Limpet Coil Calculation

This document contains calculations for determining the minimum thickness of a pipe used to withstand an internal design pressure. It lists the key parameters such as inside pipe radius, shell thickness, design pressure, allowable material stresses, and uses formulas from ASME boiler and pressure vessel codes to calculate the required pipe thickness. The results show that the permissible pipe pressure is greater than the design pressure, indicating the pipe thickness is sufficient.

Uploaded by

Adrian Stoicescu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 1

LIMPET COIL CALCULATION

DESIGN DEPT.
conversion

FORMULA UNIT CALCULATION REFRENCE SS 304 value converted

Pipe od :NPS(nominal pipe size) inch 80 80 NB sch 20 mm to inch mm/25.4 0


r = inside radius of pipe defined inch 88.9 4 thk kg/cm^2 to psi kg/cm^2 * 14.2 0

R= shell inside radius inch 820


pscal to psi pascal *1.45 x 10^-4 0

t = Shell thickness :calculated inch 8

inch 1640
Shell internal dia:

P= internal design pressure psi 42.6


UG-21

P1=design pressure in pipe (shall nt exceed P) psi 56.8

S1 =allowable tensile stress of pipe material at design


psi 18800
temperature

S=maximum allowable tensile stress at design REFER APPENDIX


psi 18800
temperature of shell or head material EE ,ASMEVIII DIV
I PAGE 652 `

The minimum thickness of a pipe ,when the thickness


does nt exceed one half of the inside pipe radius or 7238
(P does nt exceed 0.385 S1)

T= P1 * r
0.3166653288
( 0.855 S 1-0.6P1)

S'=PR/2t psi 2183.25

K= factor obtain from EE-1,2,3 REFER APPENDIX


EE ,ASMEVIII DIV
I PAGE 652
F =1.5S - S' (shall not exceed S' ) 26016.75
Permissible pipe pressure P' =F/K psi #DIV/0!

P' > P1 safe