Key Features
• Extended temperature range • 1U height, minimized depth • Hot pluggable
• Redundant fan cooling • Universal AC input • RoHS compliant
• Front panel LED indicators • Analog load sharing
Mechanical
Length (inch/mm) 8.11 / 206.0
Width (inch/mm) 4.98 / 126.5
Height (inch/mm) 1.64 / 41.6
Weight (lb/Kg) 3.08 / 1.4
Outline Drawing
Applications
• Telecommunications networks • Routers/switches • Data networks
• Digital subscriber line (DSL) • Fiber in the loop • PBX
• Indoor/outdoor wireless • Transmission
Key Features
Remote Access and Features Standard System Features Standard Battery Management Features
• Integrated 10/100Base-T Ethernet Network • Monitor and control of more than 40 • Float/boost mode control
- TCP/IP connected devices - Manual boost
- SNMP V2c for management - Maximum of 32 rectifiers - Manual timed boost locally, T1.317,
- SMTP for email - Maximum of 6 distribution control cards and remotely initiated
- Telnet for command line interface - Robust RS485 system bus - Auto boost terminated by time or
- DHCP for plug-n-play • Standard and user defined alarms current
- FTP for rapid backup and upgrades - Alarm test • Battery discharge testing
- HTTP for standard web pages - Assignable alarm severity: Critical, - Manual (local/remote)
and browsers Major, Minor, Warning, and record-only - Periodic
- Compatible with Galaxy Manager - Plant Battery Test (PBT) input driven
and other management packages • Rectifier management features
- Automatic rectifier restart - Configurable threshold or 20%
- Shielded RJ-45 interface referenced algorithm
to chassis ground - Adaptive Rectifier Management
(energy efficiency) - Graphical discharge data
• Password protected security levels: User, - Remote rectifier (on/off) - Rectifiers on-line during test
Super-User, Administrator for all access - Reserve Operation • Slope thermal compensation
• Ground-referenced RS232 system port - Automatic rectifier sequence control - High temperature
• ANSI T1.317 command-line interface - N + X redundancy check - Low temperature
• Multiple Low Voltage Load and Low Voltage - Step temperature
• Modem access support - STC Enable/Disable, low temperature
- Remote via external modem Battery Disconnect thresholds (4)
Enable/Disable
- Callback security • Configuration, statistics, and history - Configurable mV/°C slopes
• EasyView2, Windows-based GUI software for - All stored in non-volatile memory
- Remote/local backup and restore of • State of charge indication
local terminal or Modem access
configuration data • High temperature disconnect setting
• Optional 1U display with alarm indicating
backlight feature • Industry standard defaults • Reserve-time prediction
- Customer specific configurations • Recharge current limit
available
• Emergency Power-Off input
• Remote/ local software upgrade
• Basic, busy hour, and trend statistics
• Detailed event history
• User defined events and derived channels
Features
• SPS rectifiers produce 42Vdc to 58Vdc output;
up to 1600W high line, 1200W low line
• Universal AC input: 90-290VAC
• AC input options: IEC-320 C13 or C19 style cords and universal 1RU Solutions
rear AC screw terminal strip
• Temperature hardened harsh environments. (-40°C to +75°C)
• Compact 1U (1.75”) 19” mount solutions
(23” adapters available)
• Adjustable mounting ears for either flush front or 5- inch
set back position
• Up to 4 rectifier shelves may be connected together for larger
power requirements
• Plug-N-Play SPS841A controller with Web based interface
available with or without display. All controllers available with
craft port and remote LAN access.
• Integrated distribution options include one or two 30A battery
breakers, up to 10 GMT load fuses and Low Voltage Battery
Disconnect (LVBD)
• 1RU distribution panels available with battery and load
breakers as well as pluggable fuse capabilities, battery shunt Stackable Solutions
and Low Voltage Battery Disconnect (LVBD)
• 3RU DIN rail distribution panels available with battery and
load breaker positions, battery shunt and Low Voltage Battery
Disconnect (LVBD) and Low Voltage Load Disconnect (LVLD)
• Stackable solutions shelves include bus and control straps to
interconnect shelves
Custom Solutions
1RU Shelves
Rectifier Battery
Ordering Code Description (Image Key) DC Output LVD AC Input
Slots Breakers
CC109148136 J2007003L001 (A) 3 Bulk (cabled) Rear 0 None Single IEC C19
CC109146503 J2007003L001A (A) 3 Bulk (cabled) Rear 0 None Individual IEC C13
CC109156114 J2007003011 (A) 3 12 GMT’s Rear 0 None Single IEC C19
CC109148144 J2007003002 (B) 2 6 GMT's Front 1 - 30A LVBD Single IEC C13
CC109151536 J2007003002A (B) 2 6 GMT's Front 1 - 30A LVBD Individual IEC C13
CC109156907 J2007003002X (B) 2 6 GMT's Front 1 - 30A None Single IEC C13
CC109156915 J2007003'002AX (B) 2 6 GMT's Front 1 - 30A None Individual IEC C13
CC109158696 J2007003002AXB (B) 2 6 GMT's Front 0 None Individual IEC C13
CC109165890 J2007003002D (C) 2 6 GMT's / Door Front 1 - 30A LVBD Single IEC C13
CC109165916 J2007003002AD (C) 2 6 GMT's / Door Front 1 - 30A LVBD Individual IEC C13
CC109165908 J2007003002XD (C) 2 6 GMT's / Door Front 1 - 30A None Single IEC C13
CC109165924 J2007003002AXD (C) 2 6 GMT's / Door Front 1 - 30A None Individual IEC C13
CC109165932 J2007003002AXBD (C) 2 6 GMT's / Door Front 0 None Individual IEC C13
CC109146511 J2007003004 (D) 2 10 GMT's Rear 1 - 30A LVBD Single IEC C13
CC109156923 J2007003004X (D) 2 10 GMT's Rear 1 - 30A None Single IEC C13
150026024 J2007003004XB (D) 2 10 GMT's Rear 0 None Single IEC C13
CC109151544 J2007003004A (D) 2 10 GMT's Rear 1 - 30A LVBD Individual IEC C13
CC109156931 J2007003004AX (D) 2 10 GMT's Rear 1 - 30A None Individual IEC C13
150024564 J2007003004AXB (D) 2 10 GMT's Rear 0 None Individual IEC C13
CC109159372 J2007003014 (D) 2 1-30A Brkr / 10 Rear 1 - 30A LVBD Rear Terminal
GMT's
150033629 J2007003014LA (D) 2 1-30A Brkr / 10 Rear 1 - 30A LVLD Single IEC C13
GMT's
150030787 J2007003014XA (D) 2 1-30A Brkr / 10 Rear 1 - 30A None Single IEC C13
GMT's
Ordering Code AC Input , DC Output Cables (105˚C Wire) Ordering Code Alarm and Communication Cables
CC848776105 C13 plug with 5-15P plug, 14AWG, 10’ CC848890153 5’ Alarm output cable (J1)
CC848820317 C13 plug with L6-20P plug, 14AWG, 10’ CC848865980 15’ Alarm output cable (J1)
847861192 C13 plug, unterminated, 14AWG, 10’ CC848817651 50’ Alarm output cable (J1)
CC848885698 C13 AC Cord Retaining Clamp CC848890203 5’ Alarm input cable (J2)
CC848850792 C19 plug, with 5-15P plug, 12AWG, 8’ CC848853614 15’ Alarm input cable (J2)
CC848850842 C19 plug, with L6-20P plug, 12AWG, 8’ CC848890211 50’ Alarm input cable (J2)
CC848847368 C19 plug, unterminated, 12AWG, 8’ CC848847780 Shelf to shelf communication cable (J4)
(List 1, 1A only)
CC848887158 C19 AC Cord Retaining Clamp
848748987 DC output cable 2 AWG, 10’ (List 1, 1A only)
Configured Systems
Load Breaker Load GMT Battery Breaker
Ordering Code Description LVD
Positions Fuse Positions Positions
150032348 SPS-2U-AC5-PS3-PS3-DC12B 2 12 2 No
150030465 SPS-2U-AC5-PS3-DC12B-LVBD 2 12 2 LVBD
150032349 SPS-2U-AC5-PS3-DC24B 0 24 2 No
150032350 SPS-2U-AC5-PS3-DC24B-LVBD 0 24 2 LVBD
Controller
Ordering Code Description
CC109142238 SPS841A_3C3R
CC109156898 SPS841A_0I5R_D (with Display)
CC848868554 Slot Filler (List 1, 1A only)
150027896 SPS841A_960R_USB (no Display)
MAX 16
TO CONTROLLER B C C C PROBES
- + - + - + - + - + - + - + - + - + - + - + - +
G
To Controller USE COUPLER 555052-1 TO DAISY CHAIN
G ES771 G-STYLE CABLES UP TO 150 FEET
To Next ES771 Voltage Module
108958422
C C
- + - + - + - + - + - + - + - + - + - + - + - +
CC848870832 CC848903187
850036438 850029940
850041482 850039612
Bullet Style Battery Circuit Breakers (Yellow Handle) (Alarms on Mid-trip and in Off position)
Ordering Code Amperage Photo
CC408612758 30
CC408612766 40
CC408612774 45
CC408574370 50
408560123 60
CC408574387 70
CC408574395 100
CC109106548 100A battery bullet bus strap (substitute for battery breaker)
GMT Fuses
Ordering Code Amperage Photo
405006222 0.25A
3150439 0.5A
405673146 1.33A
405181983 2A
406976985 3A
406159061 5A
405725433 7.5A
406159236 10A
407845197 12A
406473959 15A
408515823 Fuse Puller
402099436 Dummy Fuse
Straight Lug (#10 bolt on 5/8” centers) for DC2, DC3, DC4, DC6 Load Connections
Ordering Code STR Wire GA (Class B) Flex Wire GA (Class I) WP-91412 List Photo
405356171* 14-10 14-10 73
405348178* 8 8 52
406338400* 6 6 108
GE
Critical Power
601 Shiloh Road, Plano, TX 75074
+1 877 546 3243 (toll-free in North America)
+1 972 244 9288 (direct number)
[email protected]
GECriticalPower.com
The GE brand, logo, and lumination are trademarks of the General Electric Company. © 2014 General Electric Company. Information
24/7 Technical Support provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
[email protected] CPB-SPS, Rev. 11/14