Estelar: Faculty of Engineering
Estelar: Faculty of Engineering
Estelar: Faculty of Engineering
6176 / O / S
FACULTY OF ENGINEERING
B.E. 4/4 (EEE/Inst.) I – Semester (Old) Examination, July 2014
Note: Answer all questions from Part-A. Answer any FIVE questions from Part-B.
PART – A (25 Marks)
r
5 List the disadvantages of induction motor operation with unbalanced supply voltages. 3
6 Write the limitations on maximum speeds of field controlled dc drive. 3
7
8
9
10 la
Differentiate between CSI and VSI fed induction motor.
Give the concept of switched reluctance motor in industrial application.
Draw the modified speed-torque characteristics of DC shunt motor.
What do you mean by four quadrant drive.
Initially the drive is working in steady state. Now the drive is braked by electrical
braking. Torque of the motor during braking is given by T = -10 – 0.04N, N-m,
calculate time taken by the drive to stop.
12 a) Describe all the five methods of modified speed torque characteristics of 3-ph
Induction motor. 5
b) A 10 KW, 440V, 3-ph 50 Hz speed control Induction motor operating at rated voltage
and frequency has the rotor copper losses at maximum torque 8 times that at full
load torque. The slip at full load torque is 0.04. Stator resistance and rotational
losses may be neglected. 5
Determine i) the slip at max. torque ii) the ratio of maximum torque to full load
torque iii) the ratio of starting torque to full load torque 5
..2
Code No. 6176 / O / S
-2-
14 Describe in detail about dual converter drive (significance, block diagram, schematic
diagram logic, merits and demerits, applications) 10
r
i) Self controlled ii) separately controlled 5+5
la
16 a) Define heating time constant and list the factors that it depend upon.
b) A 220V, 20 KW DC shunt motor running at its rated speed of 1200 rpm is to be
braked by reverse current braking. The armature resistance is 0.1, and the rated
efficiency of the motor is 300/0 calculate.
i) The resistance to be connected in series with the armature to limit the limited
braking current to twice the rated current.
5
5
te
ii) The initial braking torque. 5
17 a) The temperature rise of a motor when operating for 25 min on full load is 25 0C and
becomes 400C when the motor operates for another 25 min. On the same load.
Determine heating time constant and the steady state temperature rise. 5
b) What are the advantages of electrical drive? 5
Es
******
Code No. 6407 / N / S
FACULTY OF ENGINEERING
B.E. 4/4 (EEE) I-Semester (New) (Suppl.) Examination, July 2014
Note: Answer all questions of Part - A and answer any five questions from Part-B.
PART – A (25 Marks)
r
3 Explain briefly about the methods used to reduce the starting losses incase of d.c. and
induction motors. (3)
la
4 Explain about the dynamic braking of d.c. series motor briefly.
5 Draw the speed torque characteristics of half controlled converter fed dc separately
excited motor drive.
6 Draw the speed torque characteristics rectifier fed dc series motor for varying firing
angle.
7 Draw the circuit diagram for cyclo converter fed induction motor drive.
(3)
(2)
(2)
(3)
te
8 What is a static scherbius drive? (2)
9 List out the various applications of BLDC motor. (2)
10 Explain briefly about separating controlled synchronous motor. (3)
11 (a) Explain about the transient stability of an electric drive (synchronous motor) using
Es
13 (a) Compare the circulating and non-circulating current modes of dual converters. (4)
(b) Two quadrant operation a dc drive can be obtained using fully controlled rectifier.
Justify. (6)
14 (a) Explain about the static rotor resistance control of induction motor with neat diagram. (5)
(b) What are possible modes of VSI fed induction motor drive? Draw the circuits and
explain. (5)
..2
Code No. 6407 / N / S
-2-
r
What should be the v/f ratio at 10Hz so that the breakdown torque at the frequency
remains same as at rated frequency? (10)
*****
(10)
(5)
(5)
te
Es