Project: Mabini Pier (Conveyor Support) Location: Mabini, Batangas Owner

Download as doc, pdf, or txt
Download as doc, pdf, or txt
You are on page 1of 1

Project: Mabini Pier (Conveyor Support)

Location: Mabini, Batangas


Owner:

STRUCTURAL DESIGN CRITERIA:

1. Loads:

a. Dead load
Self weight (steel) = 77 kN/m3
Self weight (concrete) = 23.6 kN/m3
Conveyor = 0.4 T/m
Grain = 7.50 kN/m3

b. Live load
Periodic Maintenance Activity = 0.75 kPa (Assumed)

2. Materials

a. Concrete:
Compressive strength, fc’ = 28 MPa

b. Reinforcement:
Tensile strength, fy = 275 MPa

c. Structural Steel
Yield strength, fy = 248 MPa

3. Pile
Allowable Capacity = 830 kN/pile (assumed)

4. Seismic

(Minimum requirements shall be as per National Structural Code of the Philippines,


NSCP Volume 1)

V = 2.5 Ca I W /R

Where V = Base Shear


Ca = Seismic Coefficient (0.4Na)
Na = Near-source factor (1.0)
R = Response modification factor (8.5)
W = Total Dead Weight

5. Codes and References

 National Structural Code of the Philippines, Volume 1


 ASEP Steel Handbook
 ASEP Earthquake Design Manual, Volume 1
 Foundation Analysis and Design (J. E. Bowles)

6. Analysis and Design Software

 STAAD Pro 2004