CPCB Reply Affidavit Report On Hindon Action Plan
CPCB Reply Affidavit Report On Hindon Action Plan
CPCB Reply Affidavit Report On Hindon Action Plan
CORAM: HON’BLE MR. JUSTICE U.D. SALVI, JUDICIAL MEMBER, ACTING CHAIRPERSON
HON’BLE DR. NAGIN NANDA, EXPERT MEMBER
The M.A. No. 192 of 2015 and M.A. No. 193 of 2015
SS e) Muzaffarnagar and
f) Bagpat.
and filed report dated 26th October, 2016 (Page No. 1010,
and anthropogenic.
2014.
industries therefrom.
noticed:-
1. Sulphide;
2. Fluoride;
3. Mercury;
4. Cadmium;
5. Copper;
6. Zinc;
7. Lead;
8. Iron;
9. Nickel and
groundwater.
Board Laboratory.
Item No.
14 & 15
January
16, 2018
….……………………………,ACP
(U.D. Salvi)
…..…………………………….,EM
(Dr. Nagin Nanda)
Annexure-II
Annexure-III
Item Nos.
18 & 19
May 03,
2018
A
...…..…………………………….,JM
(S.P. Wangdi)
...…..…………………………….,EM
(Dr. Nagin Nanda)
03.05.2018
Annexure-IV
A meeting was convened on 28.06.2018 in CPCB under the Chairmanship of ‘Member Secretary,
CPCB’ with the officials of U.P.Pollution Control Board, U.P.Jal Nigam, U.P.Agriculture Department
and Central Ground Water Board (NR), Lucknow to discuss about findings of CPCB on the water
quality of river Hindon and its tributaries, ground water samples collected from the catchment area of
river Hindon as well as inspections carried out by Joint Inspection Teams constituted for industrial
inspections as well as draft action plan proposed to be filed in compliance to Hon’ble NGT (PB)
order dated 16.1.2018 in the matter of O.A No. 231/2014 and O.A No. 66/2015 filed by Doaba
Paryavaran Samiti Vs State of Uttar Pradesh & Others. Dr A. B. Akolkar, Ex Member Secretary and
Member of the Hon’ble NGT Committee could not attend the afore-said meeting due to pre-occupied
assignment. List of officials attended the afore-said meeting is attached at Annexure I.
Member Secretary, CPCB welcomed all the officials of UPPCB, UP Jal Nigam, U.P.Irrigation
Department, Central Ground Water Board (CGWB) and informed that all the industrial inspections as
well as sampling of river Hindon & its tributaries and drains as well as ground water samples in the
catchment area of river Hindon has been completed in compliance to the Hon’ble NGT order dated
16.01.2018 in the afore-said matter. Member Secretary, CPCB also acknowledged that gathering
and compilation of all the information at one place was a comprehensive exercise which has been
completed by CPCB. Thereafter, he requested Dr.R.M.Bhardwaj, AD & In-Charge, WQM- Division to
explain about comprehensive task carried out by CPCB in compliance to the Hon’ble NGT orders.
Dr. R.M Bhardwaj explained that the UPPCB submitted a report dated 29th October 2015 to Hon’ble
NGT in compliance to the Hon’ble NGT order in the matter of O.A No 231/2014 and O.A No
66/2015, covering compliance status of 316 industries indulged in discharging of industrial effluents
in river Hindon and its tributaries. Based on the report submitted by UPPCB, Hon’ble NGT (PB)
passed an order on 16.01.2018 directing CPCB to co-ordinate for joint inspection of 316 industries,
sampling of river Hindon & its tributaries, drains contributing to pollution of river Hindon as well as
ground water samples in the catchment area of river Hindon and for submission of the
comprehensive report to Hon’ble Tribunal within two months. Thereafter, CPCB initiated the actions
and submitted an interim report and sought additional time in view of some constraints especially
w.r.to CPCB laboratories for completion of analysis of collected samples and thereafter for
submission of the report. Hon’ble NGT has accepted the prayer and extended time for submission of
the comprehensive report and now the matter is listed for hearing on 12th July 2018. Based on the
findings of inspection of industries, analysis results of collected industrial effluents, samples of river
Hindon & its tributaries, drains and groundwater samples, a comprehensive as well as proposed
action plan for rejuvenation of river Hindon has been prepared. A copy of the draft action plan
prepared by CPCB for rejuvenation of river Hindon alongwith agenda of the meeting is also been
circulated. Thereafter, he requested Shri J.Chandra Babu, Sc’D’, WQM-I to present the findings.
Shri J. Chandra Babu, Scientist D , WQM-I Div made a detailed presentation on the initiatives taken
in compliance to Hon’ble NGT Order dated 16.01.2018 which include directions of Hon’ble NGT,
findings of industrial inspections, analysis results of the GW samples collected by 52 no. of joint
inspection teams during 5 th March - 26 th April 2018. He has further elaborated on the analysis
results of the surface water samples from River Hindon, River Krishni, River Kali (West) and River
Sheela as well as from six drains. Salient features of the power point presentation made by Shri
J.C.Babu include
(i) Total No. of surface water samples collected from River Hindon, River Krishni, River Kali
(West), River Sheela and River Yamuna (after confluence of river Hindon) as well as samples
collected from six drains- 67;
(ii) Total no. of ground water (GW) samples collected from 168 locations in catchment area of
river Hindon and its tributaries - 545;
(iii) Total no. of industry specific parameter samples from ETPs- 569;
(iv) Total no. of samples collected and analysed in CPCB labs- 1181;
(v) Groundwater samples were analysed for parameters such as Fluoride, sulphate, Oil & Grease
and heavy metals as directed by Hon’ble NGT;
(vi) The analysis results of the ground water samples reveal that (a) 93 out of 168 GW sampling
locations (located at Baghpat, Ghaziabad, Greater Noida, Meerut, Muzaffar Nagar,
Saharanpur and Shamli except in Gauthambudh Nagar) were observed to be contaminated
with one or more parameters and exceeded BIS Drinking Water Specifications; and
concentration of Sulphate, Fluoride, O & G, heavy metals such as Cd, Cu, Pb, Fe, Ni, Zn, Hg
and Mn are exceeding the prescribed limit at 5, 11, 1, 4, 5, 14, 33, nil, 04, 39 and 13 no. of
locations respectively;
(vii) The analysis results of the samples collected from River Hindon, Sheela, Kali (West) and
Krishni and the drains samples reveal that (a) all the four rivers namely Hindon, sheela (except
FC), Kali (West) and Krishni are not complying to the water quality criteria parameters; (b)
Drains namely Karheda Drain B/c of River Hindon, Indirapuram Drain B/c of River Hindon,
Hindon Vihar Drain B/c of River Hindon, Pratap Vihar Drain B/c of River Hindon, khaila Bhatta
Drain B/c of River Hindon except Kot Escape Drain are not complying to the effluent discharge
standards for inland surface water especially (w.r.to BOD and COD) prescribed under
Schedule-VI of the Environment (Protection) Rules, 1986;
(viii) Also, presented status of industries which are operational, partially operational, not
operational, closed and the industries which does not exist at the given address.
(ix) Status of industries w.r.to the Consents under Water & Air Acts as well as authorization under
the Hazardous & Other Waste (Management & Transboundary Movement) Rules, 2016 as
amended; Also, status of industries w.r.to the industries which are having ETPs, No. of
industries not operating ETPs, No. of industries installed OCEMS;
(i) (xi) Sources of water consumed by the industries include mainly Tube Well, through tankers as
well as extraction from Upper Ganga Canal and total water consumption by 255 no. of
industries (as information available) was observed as 95,270 KLD and wastewater generation
from 232 industries was observed as 65646 KLD as well as district/area-wise water
consumption and wastewater generation, and (xii) 119 out of 195 no. of industries operating
ETPs are not complying to the effluent discharge norms.
Dr Vikas Ranjan, Scientist C, CGWB informed that ‘Fluoride and Iron content in Ground Water may
be compared with its highest limit as specified by BIS standards for drinking water. Dr Vikas also
opined that occurrence of ‘Fluoride and Arsenic’ content in ground water is geogenic in nature and it
is not linked to pollution problem. However, he requested CPCB to provide list of locations where the
groundwater is found contaminated for further action on the part of CGWB and other concerned
agencies of State/District or Local administration.
Dr.R.M.Bhardwaj requested the official of CGWB to provide list of industries for which
permission/NOC were granted to extract groundwater to CPCB so that such information also be
included in the report to be filed before Hon’ble NGT. In response, CGWB official mentioned that
NOC is being given by CGWB for extraction of ground water resources by industries subject to the
conditions as per the guidelines issued by CGWB. Dr.Vikas representative of CGWB also informed
that District Level Committee under District Magistrate has been empowered for random inspections
and for strict vigilance on groundwater extraction by the industries. He opined that State Level
vigilance is required especially from the State Ground Water Department as Govt. of Uttar Pradesh
vide GO 1624/62-1-2004-7 W.P. No. 0/2004 TC dated September 8, 2004 declared Ground Water
Department as Nodal Agency
Member Secretary, CPCB expressed his concern that both surface and ground water is being
polluted which is a ground reality and is evident based on the findings of the inspections while the
drains are carrying only the industrial effluent or sewage which clearly indicates that discharge of
partially treated/untreated outfalls in the rivers. He also stated that some of the industrial units are
still operating without Consents under Water & Air Acts which is a violation of Hon’ble Supreme
Court directives and therefore UPPCB should look into the matter and take necessary action
immediately for closure of such units. He also indicated that industries are extracting ground water
and discharge in surface or on land without proper treatment hence polluting both surface water and
groundwater. Therefore, all the concerned authorities on the related aspects may initiate actions and
both short term and long term action plans need to be prepared and executed as proposed in the
draft action plan circulated in the meeting. He also stated that the concerned authorities should
initiate actions on priority basis for ensuring compliance to the provisions of E (P) Act, 1986, without
waiting for further orders from Hon’ble NGT .
Shri R.M. Bhardwaj informed that the protection and control of over exploitation of ground water
resources lies with the CGWB and U.P.Jal Nigam and action need to be taken to control over
exploitation of groundwater resources especially by the industries. He also mentioned that the
wherever ground water is not fit for drinking purposes, U.P.Jal Nigam may provide alternate supply
of potable water for the concerned public and an action plan in this regard need to be prepared.
Representative of UPJal Nigam informed that wherever water is not fit for drinking purposes they are
presently supplying water in many villages of Ghaziabad. UP Jal Nigam , Bagpat representative
informed that proposals have already been submitted to the Central/State Govts and no sanction of
funds have been received so far. He also mentioned that funds are being given by the Central Govt
only for Fluoride or Arsenic contaminated affected villages and as such there is no any such scheme
by the Central/State Govt for ‘Iron’ affected blocks or villages. Upon sanction of funds from the
concerned Govts, he is of the opinion that the proposed schemes shall be implemented effectively.
Shri J.C Babu, Sc’D’ also displayed the draft action plan for rejuvenation of River Hindon prepared
by Dr A.B.Akolkar along with the officials of WQM-I Division in CPCB and proposed to be submitted
for perusal of Hon’ble NGT. Shri Nazimuddin, AD, CPCB suggested to include time targeted action
plans as a part of the action plan. In response, Sh J.C Babu informed that this aspect has been
thought of and also as suggested by CCB, same will be included while reviewing the comments.
Thereafter, Shri J.C.Babu also requested all the officials attended the meeting to provide comments
or suggestions if any on the draft action plan by 02.07.2018 so that comments can be considered
and proposed draft action plan can be modified suitably prior to filing before the Hon’ble NGT for
consideration.
Representative of UP Agriculture Department informed that the check dams constructed earlier for
different purpose is now stagnant pool of wastewater which in turn causing contamination of
groundwater resources. Therefore, there is a need to take action for demolition of such check dams
wherever required.
Upon deliberations following decisions were taken in the afore-said meeting as detailed below:-
(i) To provide comments or views or suggestions if any on the proposed draft action plan for
rejuvenation of river Hindon which has been circulated in the meeting to all the officials, so as
to reach CPCB by 2nd July, 2018;
(i) Upon receipt of comments if any on the proposed draft action plan for rejuvenation of the river
Hindon, proposed draft action plan be finalised by CPCB after incorporating the comments, for
filing before the Hon’ble NGT for consideration; and
(ii) After filing of the affidavit along with the findings as well as draft proposed action plan before
the Hon’ble NGT by CPCB, list of non-complying units as well as non-complying ground water
sampling locations also be made available to UPPCB, UP Jal Nigam/CGWB/CGWA
respectively for initiating further necessary appropriate actions by all the concerned
departments.
-- OO --
Annexure-I
List of Officials attended meeting held at CPCB on 28.6.2018 with the Officials of UPPCB, U.P. Jal
Nigam, U.P.Agriculture Department, CBWB and Others concerned for ensuring compliance to the
Hon’ble National Green Tribunal (PB), New Delhi Order dated 16.01.2018 in the matter of O.A No.
231/2014 and O.A No. 66/2015 filed by Doaba Paryavaran Samiti Vs State of Uttar Pradesh &
Others
Sl. Name of Official Designation E-mail ID
No.
1. Shri A.Sudhakar Member Secretary, CPCB [email protected]
2. Shri Gurnam Singh AD, CPCB [email protected]
3. Dr. Sanjeev Agrawal AD, CPCB [email protected]
4. Shri Nazimuddin AD, CPCB [email protected]
5. Shri P.K. Mishra AD, CPCB [email protected]
6. Shri A. Aggarawal AD, CPCB [email protected]
7. Shri Devender Kumar Ex. Engineer, U.P.Jal [email protected]
Nigam, Ghaziabad
8. Shri Sanjay Kumar Gautam Ex. Engineer , U.P.Jal [email protected]
Nigam, Baghpat
9. Dr. Vikas Ranjan Scientist ‘C’, CGWB (NR), [email protected]
Lucknow
10. Shri Ashok Kumar Tiwari RO, UPPCB, Ghaziabad [email protected]
11. Shri S. R. Maurya R.O. UPPCB, Saharanpur [email protected]
12. Dr. Yogendra Kumar ASO, UPPCB, Meerut [email protected]
13. Shri Ravindra Singh Project Manager, U.P.Jal [email protected]
Nigam, Saharanpur
14. Shri Krishna Mohan Yadava GM, U.P.Jal Nigam [email protected]
15. Shri Chaman Singh Soil Conservation Officer, [email protected]
Agricuture Dept. U.P.
16. Shri Ankit Singh AEE, UPPCB,Ghaziabad [email protected]
17. Shri Utsav Sharma AEE, UPPCB, G.Noida [email protected]
18. Shri J.B. Singh AEE, UPPCB, [email protected]
Saharanpur
19. Mrs.Urmila Thakur Low Officer, CPCB [email protected]
20. Shri Kamal Bandhu Assistant Low Officer, [email protected]
CPCB
21. Shri Sanjay Kumar Scientist ‘D’, CPCB [email protected]
22. Dr.R M Bhardwaj Scientist ‘E’,DH, WQM-I [email protected]
23. Shri J. Chandra Babu Scientist ‘D’, WQM-I [email protected]
24. Mrs.Suniti Parashar Scientist ‘B’, WQM-I [email protected]
25. Dr. Deepika Mehta RA, WQM-I, CPCB -
26. Ms. Deepti Goyal JRF, WQM-I, CPCB -
27. Mr. Chenchal Joshi DEO, WQM-I, CPCB -
28. Mr.R.D.Swamy DEO, WQM-I, CPCB -
Annexure-V
AND
IN THE MATTER OF
Comprehensive Report on
Prevention and Control of Pollution
in River Hindon: An Action Plan for Rejuvenation
(Submitted in Compliance to Hon’ble National Green Tribunals (NGT)
Order dated January 16, 2018)
i
S.No. Particulars Page No.
Area/district-wise water consumption and waste water
Figure 4
generation from the industries
Area/District-wise compliance status of no. of GW
Figure 5 sampling locations w.r.to IS 10500:2012 Drinking
Water Standards
Industry Sector Wise (Grouped) Complying to Effulent
Figure 6
Discharge Norms ( in Numbers and %)
List of Tables
District/Area-wise details of no. of Industries
Table 1 Inspected and no. of industrial effluent samples
collected by the Joint Inspection Teams
District/Area-wise no. of groundwater sampling
Table 2 locations and No. of ground water samples collected
by the Joint Inspection Teams
Sampling location details of River Hindon, River Kali
Table 3
(West), River Krishni and drains joining River Hindon
Total no. of samples collected from River Hindon,
Table 4 River Krishni, River Kali (West), River Sheela and
River Yamuna as well as 06 no. of Drains.
Minimum and maximum concentration of SO4,
Fluoride and Heavy Metals and No. of GW sampling
Table 5
locations not complying with the IIS 10500-2012
drinking water specifications (acceptable limits)
Analysis results (in ranges) of the samples collected
Table 6 from River Hindon, Kali (West), Krishni, Sheela and
River Yamuna after confluence of River Hindon
Analysis results of the samples collected from 6 no. of
Table 7
drains contributing to pollution load in River Hindon
Area/District-wise Type of Industries (grouped)
Table 8
located in the U.P. State
Industrial sector-wise operational status of 317
Table 9
Industries
Table 10 List of industries doesn’t exist at the given address
District/Area-wise Consent (under Water Act and Air
Table 11
Acts) Status of industries
District/Area-Wise Authorization (under [H & OW ( M
Table 12
& TM) Rules, 2016 as amended ) Status of Industries
Area/District-wise total water consumption, industrial
Table 13 waste water generation and final mode of disposal of
generated industrial effluent
List of Industries in which ETP exist but not
Table 14
operational
Area/District-wise ground water sampling locations
complying and non-complying to the Bureau of Indian
Table 15 Standard drinking water specifications (second
revision) IIS10500-2012 w.r.to the acceptable limits (
within and outside industry premises)
Area/District-wise no. of industries installed ETPs and
ETPs Operational and the total no. of industries
Table 16
complying and not complying to the effluent discharge
norms
Industrial-sector-wise (grouped) no. of industries
Table 17 complying and non-complying to the effluent
discharge norms
ii
S.No. Particulars Page No.
List of Annexures
iii
Comprehensive Report on Prevention and Control
of Pollution in River Hindon: An Action Plan for
Rejuvenation
(Submitted in Compliance to Hon’ble National Green Tribunal (NGT) Order dated January 16, 2018
in the matter of O.A. No. 231/2014 & O.A. No. 66/2015 filed by Doaba Paryavaran Samiti Vs State
of Uttar Pradesh & Otrs.)
1.0. Introduction
Hon’ble National Green Tribunal (NGT) in the matter of Original Application No.
231/2014 & Original Application No. 66/2015 filed by Doaba Paryavaran Samiti Vs
State of Uttar Pradesh & Otrs, on 16.01.2018 has given the following directions
which are reproduced as follows:
3. They shall carry out joint inspections of 316 industries which are listed in the
report dated 29th October, 2015 (Page 230, Volume I-A, Original Application
No. 66 of 2015) and others as well to give answers to the queries already
made and ascertain contribution of each of the industries in terms of the
contaminants generated by them.
1
4. The Central Pollution Control Board and Uttar Pradesh Pollution Control
Board shall bear the expenses of the said inspection team in terms of the
order passed on 20th April, 2017 in Samir Mehta Vs Union of India & Ors.. The
inspection shall be completed and report shall be submitted to the Tribunal
within two months.
5. The Central Pollution Control Board shall be convener of the team. In case of
any difficulty the Central Pollution Control Board may approach the Tribunal.
Subsequently, Hon’ble National Green Tribunal (NGT) further heard the matter on
March 19, 2018 and May 03, 2018 and passed order on 03.06.2018 and directed
Central Pollution Control Board as follows:
‘Mr. Rajkumar learned counsel for Central Pollution Control Board submits that out of
the 1166 samples collected, 50% of which have been analysed and would require
further six weeks’ time to complete analysis of the remaining samples. In view of this
submission, we grant the requested period of time for submission of analysis report.
Copies of Hon’ble National Green Tribunal orders dated January 16, 2018, March
19, 2018 and May 03, 2018 which are annexed as Annexure-I to Annexure-III.
2.0 About River Hindon, River Kali (West) and River Krishni
River Hindon, River Kali and River Krishni and Other drains is given in Figure 1.
(a) Hindon River originates from lower Shivalik ranges in District Saharanpur of
Uttar Pradesh and is primarily a rain fed river. The basin area falls in the districts of
Saharanpur, Muzaffarnagar, Shamil, Meerut, Bagpat, Ghaziabad and Gautambudh
Nagar in Western Uttar Pradesh and covers a distance of about 200 Km before
joining the river Yamuna downstream of Delhi. It leaves District Saharanpur at
Village- Chhinau and flows into District Muzaffarnagar. Hindon river enters District
Muzaffarnagar at Village- Budha khedi and leaves the District for Meerut near
Village- Atali. River Hindon enters District Meerut at Village- Baparsi. The river flows
in between District Meerut and Bagpat and it leaves at Village Rasoolpur Dhaulari of
District Meerut and Village Baleni of District Bagpat before entering District
2
Ghaziabad. River Hindon enter Ghaziabad city at village Karheda and passes
through Hindon river Bridge, Karheda Road Bridge at NH-24, Railway Bridge,
Hindon Barrage, Road Bridge at NH-58 and then enters in district Gautambudh
Nagar. River Hindon enters into District Gautambudh Nagar from Ghaziabad at
Chajarshi near Sector-62 and finally meets into river Yamuna at Village- Gharbara of
Mauja Tilwara i.e., down stream of Delhi). The major source of flow in the river is
mainly domestic and industrial discharges.
The river Hindon is one of the important rivers in western Uttar Pradesh (India)
having a basin area of about 7000 km 2 . The catchment area of the river lies
between latitude 28o 30’ to 30o15’ N and longitude 77o 20’ to 77o 50’ E. The Hindon
River has been a major source of water to the highly populated and predominantly
rural population of Western Uttar Pradesh. The heavy loading of industrial effluent
discharge directly into the Hindon River places an intolerable burden on the river’s
natural ability to assimilate pollutants.
Figure 1. River Hindon, River Kali (West), River Krishni and Other drains.
(b) River Kali (West) originates from village Iqbalpur, district Haridwar,
Uttarakhand and enters Uttar Pradesh in District Saharanpur and then in District
3
Muzaffarnagar near Rohanakala. The river carries Domestic and Industrial waste
from District Saharanpur and District Muzaffarnagar. Kali River (West) finally meets
river Hindon near village Ratanpuri and Hindon enters District Meerut at village
Pithlokar.
(c) River Krishni is primarily a rain fed river with no natural flow of its own. The
major source of flow in the river is domestic and industrial discharges. It enters
District Shamli in Nagar Panchayat Jalalabad and enters in District Bagpat near
village Ramala. After travelling about 20 to 25 Km., it merges into river Hindon near
village Barnawa.
The main sources of pollution in River Hindon include municipal and industrial
(sugar, pulp and paper, distilleries etc.) wastes mainly from Saharanpur,
Muzaffarnagar and Ghaziabad urban areas. Three effluents drains namely Nagdev
Nala, Star Paper Mill Drain and Dhamola Nala join the river Hindon in upper section.
The Nagdev nala receives municipal wastewater of the adjoining villages as well as
industrial effluents from various industrial units. The Star Paper Mill is located near
Saharanpur railway station and manufactures varieties of paper used in writing,
printing, craft (for wrapping) and wall papers. Other sources of pollution in river
Hindon are the sewage of Saharanpur town and other effluents from textile mill,
sugar mill, card board factory, laundary and other small industrial units which
discharge their waste effluents into Dhamola nala which in turn enters into river
Hindon.
The portion of River Hindon catchment in the vicinity of Muzaffar Nagar is not
directly contributing municipal and industrial effluent into the river Hindon as the local
industries are discharging wastewater effluent in tributary streams namely river Kali
(West)or river Krishni. Main sources which create pollution in the river Kali (West)
include municipal wastewater of Muzaffar Nagar city, industrial waste from industries
(such as pulp and paper, sugar, distilleries, steel, rubber, ceramic, chemicals, plastic,
dairy and laundries). Main industrial units are Mansurpur sugar mill and distillery out
falling in river Kali (West) and Shamli sugar factory and distillery discharge in the
river Krishni. River Kali (West) opens into river Hindon near the village of Atali and
river Krishni near Sardhana. In summer months the river is completely dry from its
origin upto Saharanpur town. The effluents of Nagdev nala and star paper mill at
Saharanpur generate the flow of water in the river Hindon. The municipal waste
water generated from the Saharanpur city is discharged into Hindon river through
Dhamola nala. The municipal waste water from budhana town also joins the river in
this stretch.
4
The river Kali (West) meets the river Hindon on its left bank near the village of Atali
and carries municipal waste water and effluents of industries located in the
Muzaffarnagar city. Another tributary called Krishni meets Hindon on its right bank at
village Barnawa in Meerut district and transports the waste water from sugar mill and
distillery. In Ghaziabad district, downstream of Karhera village, major part of the river
flow is diverted to Hindon cut canal at Mohan Nagar which meets river Yamuna
upstream of Okhla barrage. Thereafter, the river Hindon receives waste water
through Dhasana Drain at village Bisrakh in Ghaziabad district. The Dhasana drain
carries the waste water of municipal as well as industrial establishments located in
Ghaziabad. River Hindon flows further downstream and joins river Yamuna at village
Tilwara in Uttar Pradesh State.
3.0 Initiatives taken by CPCB for ensuring compliance to the Hon’ble National
Green Tribunal (NGT) Order dated 16.01.2018
3.1 Meeting held with the Officials of UPPCB and U.P. Jal Nigam
In pursuance to the Hon’ble NGT order dated 16.01.2018, Central Pollution Control
Board (CPCB) convened a meeting in CPCB on 16.02.2018 with the Officials of
U.P Pollution Control Board (UPPCB), U.P Jal Nigam (UPJN) and discussed issues
relating to the follow-up actions to be taken for ensuring compliance to Hon’ble NGT
Order dated 16.01.2018. A copy of the minutes of the meeting held with the officials
of UPPCB and UPJN and other concerned officials is enclosed as Annexure-IV.
Main decisions taken in the afore-said meeting are as follows:
ii) Joint Inspection of 316 industries shall be completed within 15 days from the
date of Constitution of the Joint Inspection Team (s).
iii) Assessment of Ground Water Quality in six identified districts shall be carried
out by the teams comprising Officials of CPCB, UPPCB, U P Jal Nigam and
U.P. District Agriculture Department along with the monitoring of the industrial
units.
5
iv) The representative of Law Officer (LO), CPCB was requested to collect the
detailed report filed by Central Ground water Authority (CGWA) to Hon’ble
NGT (PB), New Delhi..
v) Collected water samples during the inspection shall be submitted only at the
CPCB (HO) Laboratory by the respective Joint Inspection Team members
soon after completion of the visit and the analysis of submitted samples shall
th
be completed by 09 March, 2018 by CPCB (HO) Laboratory. Thereafter, the
inspection reports duly signed by the inspection team members shall be
submitted by 13.03.2018 to the WQM-I Division, CPCB for compilation and
preparation of the interim report/ comprehensive report.
vi) If required, Committee may submit an ‘Interim Report’ before next date of
hearing through ‘Legal Cell’ in CPCB and may seek additional time for
submission of the detailed report preparation and its submission to the
Hon’ble NGT (PB), New Delhi, if required after approval of the report by the
Committee.
3.2 Teams constituted for Joint Inspection of 316 Industries located in U.P. as per
the list provided to Hon’ble National Green Tribunal (PB), New Delhi by
U.P.Pollution Control Board (UPPCB)
Central Pollution Control Board (CPCB) has constituted 52 Joint Inspection Teams to
carry out joint Inspection of 316 Industries located in the afore-said six districts, vide
Office Orders No. A-14011/1/2018-MON/2635 dated 23.02.2018 & 26.03.2018. A
Copy of the CPCB Office Orders dated 23.02.2018 and 26.03.2018 constituting 52
Joint Inspection Teams are enclosed as Annexure –V.
CPCB also held interactions with the Joint Inspection Team leaders of CPCB on
27.02.2018 in CPCB so as to give necessary instructions for inspection of industries
as well as collection of samples from the industrial effluents or ground water samples
and also circulated requisite materials with regard to the procedures to be followed
for preservation of collected industrial effluent as well as ground water samples for
further analysis in CPCB laboratory as well as a format for submission of the visit
report by all the joint inspection team leaders.
3.3 CPCB letters to Uttar Pradesh Pollution Control Board (UPPCB), UP Jal Nigam
(UPJN), Central Ground Water Authority (CGWA) & U.P Agriculture Department
Subsequent to the meeting held with the Officials of UPPCB, UP Jal Nigam and U.P.
Agricultural Department, CPCB vide letter No. A-14011/WQM-I/2018/17498 dated
23/02/2018 requested UPPCB and U.P. Jal Nigam to nominate concerned officials
6
to associate with the Joint Inspection Teams for the purpose of completion of joint
inspections of 316 industries located in U.P as well as collection of ground water
samples in the respective areas. Copies of CPCBs letters dated 23.02.2018
addressed to UPPCB, UPJN and Central Ground Water Authority (CGWA), New
Delhi are enclosed as Annexure- VI to Annexure-VIII.
3.4 Status of compliance in pursuance to the Hon’ble NGT (PB) order dated
16.01.2018 with regard to industrial inspections
The Joint Inspection Teams comprising representatives of CPCB, U.P. Jal Nigam
and U.P.PCB officials inspected 317 industries during March 05, 2018 to
April 26, 2018. District/Area-wise no. of industries inspected and no. of industrial
effluent samples collected by the Joint Inspection Teams is given in Table.1.
During the visit to the industries, the visited teams have also collected 569 industrial
effluents to assess compliance to the effluent discharge standards stipulated by
U.P.Pollution Control Board.
3.5 Status of compliance in pursuance to the Hon’ble NGT (PB) order dated
16.01.2018 w.r.to collection of ground water, river water and drain samples in
the catchment of river Hindon
In pursuance to Hon’ble NGT (PB) order dated 16.01.2018, Joint Inspection Teams
also collected ground water samples from 168 locations either from industry
premises or from nearby village in the vicinity of the industries inspected during the
period March 05, 2018 to April 26, 2018 i.e., ground water samples collected from 72
7
sampling locations within industry premises and 96 ground water sampling locations
are outside industry premises or hand pumps located in villages close to the
inspected industries. About 545 ground water samples were collected from 168
ground water sampling locations. District/ Area-wise groundwater samples collected
by the joint inspection teams are given in Table 2.
Apart from the above, in compliance to the Hon’ble NGT (PB) order dated
16.01.2018, during March 08-09, 2018, on April 11, 2018 and on April 13, 2018,
officials comprising Central Pollution Control Board (CPCB), Dr.A.B.Akolkar, Expert
Committee Member appointed by Hon’ble NGT(PB) also collected 67 samples from
05 rivers mainly from River Hindon ( 5 No of locations), River Krishni (01 location),
River Kali (West) (2 locations), River Sheela and River Yamuna (each at one
location) after confluence of River Hindon as well as 06 drains namely Khareda
Drain, Indirapuram Drain, Hindon Vihar, Pratap Vihar, Khaila Bhatta and Kot
Escape.
To study the impact on river Hindon, samples of 05 rivers as well as 06 drains were
collected at salient points mainly covering before and after confluence of River
Sheela with River Kali (West), before and after confluence of river Kali (West) with
River Hindon, before and after confluence of river Krishni with river Hindon, before
and after confluence of 06 drains with river Hindon and finally river Yamuna after
confluence of River Hindon. Details of sampling locations of rivers/drains and total
no. of samples collected from River Hindon, Kali (West), Krishni, Sheela, River
Yamuna and 06 drains joining River Hindon along with date of sampling are given in
Table 3 and Table 4.
8
Table 3. Sampling location details of River Hindon, River Kali (West), River
Krishni and 6 no. of drains joining River Hindon
Table 4. Total no. of samples collected from River Hindon, River Krishni, River
Kali (West), River Sheela and River Yamuna as well as 06 no. of Drains
9
The sampling location details of River Hindon, Krishni, Kali (West), Sheela and
River Yamuna as well as 06 no. of Drains are given in Figure 2.
Figure 2. Sampling details of River Hindon, River Krishni, River Kali (West) and
River Sheela as well as Drains
Photographs taken during the sampling of drains, river Hindon, River Krishni and
River Kali (West) are given in Figure 3.
10
River Hindon, Puramahadev River Krishni and Hindoan confluence
11
Plsastic Waste in Drain Dadera Drain at
River Krishni B/c of River Hindoan
Muzaffarnagar
Figure 3. Sampling of Drains and River Hindon carried out by the Officials of
CPCB and the Expert Member Constituted by the Hon’ble NGT (PB)
12
4.0. Status of water quality of ground water in the study area
As indicated in section 3.5.1, ground water samples (545 nos) were collected from
168 sampling locations by the joint inspection teams. 72 out of 168 ground water
sampling locations are located within the industry premises and 96 ground water
sampling locations are located outside industry premises. The ground water samples
collected from afore-said locations were analysed for parameters such as Sulphates
(SO4), Fluoride (F) and Oil & Grease ( O & G) as well as heavy metals such as
Cadmium (Cd), Copper (Cu), Lead (Pb), Iron (Fe), Nickel (Ni), Zinc (Zn), Mercury
(Hg) and Manganese (Mn) in CPCB Laboratories. Water Quality Monitoring Results
of ground water samples collected by the Joint Inspection Teams is given in
Annexure-IX. Minimum and maximum concentration of SO4, Fluoride and heavy
metals and no. of GW sampling locations not complying with the IS 10500-2012
drinking water specifications (acceptable limits), as amended is given in
Table 5.
Maximum
2 (in mg/l) 330 2.5 0.74 1.25 1.74 21.81 0.02 9.12 1.03 2.16 10* 0.26
No. of
locations
3 exceeding 5 11 4 5 14 33 - 4 13 39 01* 04
the limit
IS10500-2012
Drinking Water
Specifications-
200 1.0 0.003 0.05 0.01 0.3 0.02 5 0.1 0.001 0.5* 0.05
Acceptable Limit
(in mg/l )
Note: Generally in case of Groundwater samples, concentration less than or equal to 2 mg/l is
indicated as BDL by CPCB laboratories. In such a case, no. of locations exceeding the BDL
(2 mg/l) is only at one location. But as per BIS Drinking Water Specifications, mineral oil
content at 67 GW sampling points exceed the limit of 0.5 mg/l.
Analysis results of the ground water samples collected from 168 sampling locations
in U.P. State reveals that the samples w.r to Sulphate (SO4-), Fluoride (F), heavy
metals such as Cadmium (Cd), Copper (Cu), Lead (Pb), Iron (Fe), Nickel (Ni), Zinc
(Zn), Manganese (Mn), Mercury (Hg), O & G and Total Chromium (Cr) are in the
order of 2 to 230 mg/l, 0.1 to 2.5 mg/l, 0.002 to 0.74 mg/l, 0.003 to 1.25 mg/l, 0.013
to 1.74 mg/l, 0.002 to 21.81 mg/l, 0.003 to 0.02 mg/l, 0.002 to 9.12 mg/l, 0.002 to
1.03 mg/l, 1 to 2.16 mg/l, BDL to 10 mg/l and 0.002 to 0.26 mg/l respectively.
13
5.0. Water quality status of River Hindon, Krishni, Kali (West), Sheela and the
drains
During March 08, 2018 and April 13, 2018, as indicated in section 3.5.2, river water
samples were collected from River Hindon at five locations (i.e., Budhana, after
confluence of River Kali (West) and before confluence of River Krishni, at Pura
Mahadev, on U/s and before confluence of Khareda Drain and before confluence of
River Yamuna), River Krishni at Barnawa, River Kali (West) at two locations (i.e., at
Budhana – Khatoli Road and before confluence of River Hindon and at U/s Muzaffar
Nagar and after confluence Sheela river) and from Sheela River at B/c River Kali (W)
as well as from River Yamuna after confluence of River Hindoan and 06 drains.
Water Quality Monitoring Results of River Hindon, Krishni, Kali (W), River Yamuna &
06 drains collected during March- April, 2018 is given in Annexure-X. Analysis
results of samples collected from 05 rivers and 06 drains with ranges for general
parameters and heavy metals are given in Table 6 and Table 7.
Table 6. Analysis results (in ranges) of the samples collected from River Hindon, Kali
(West), Krishni, Sheela and River Yamuna after confluence of River Hindon
Non-
complying
4 Sheela 01 7.4 4 490 BDL BDL BDL 0.89 BDL 0.04 0.02
except FC
Non-
5 Yamuna 01 0.6 14 1400000 BDL 0.20 BDL 4.21 BDL BDL BDL complying
≤ 500
Water Quality Criteria ≥5 ≤3
MPN/ - - - - -
(WQC) Limit for Bathing mg/l mg/l -
100 ml
14
Analysis results of the samples collected from 05 rivers reveals that the samples w.r
to water quality criteria for bathing parameters such as dissolved oxygen (DO),
bio-chemical oxygen demand (BOD) and Fecal Coliform (FC) in river Hindon & Kali
(West) are in the order of 0 to 1.9 mg/l & 0 to 6.6 mg/l; 9-238 mg/l & 3-311 mg/l;
3300 – 9200000 & 3300 – 9200000 MPN/100 ml whereas in river Krishni, Sheela
and Yamuna, the values of DO, BOD and FC are observed as nil, 7.4 & 0.6 mg/l;
34, 4 & 14 mg/l, 54000, 490 & 14,00,000 MPN/100 ml respectively.
Apart from the above, pesticides especially Organochloro Pesticides (OCPs) namely
α-HCH, γ-HCH, Dieldrin, α-Endosulfan, β-Endosulfan and p.p’-DDE in the four rivers
except River Sheel was observed as ‘BDL’, whereas β-HCH, Aldrin, o,p’-DDT,
p,p’-DDT are observed in the order of BDL- 0.22 µg/l ( exceeding the IS 10500-2012
limit of 0.04 µg/l at Kali B/c of River Hindon, River Hindoan at Budana, River Hindon
A/c of Kali (West) and B/c of River Krishni); BDL to 8.57 µg/l ( exceeding the limit of
2 µg/l at River Hindon at A/c of Kali (West) and B/c of River Krishni and River Hindon
at Puramahadev); BDL-0.18 µg/l and BDL - 0.14 µg/l (< 1 µg/l). Organophosphorous
Pesticides (OPPs) which include Dimethoate, Methyl Parathion, Malathion,
Chloropyrifos and Ethren in the River Hindon, River Krishni, River Kali (West) and
River Yamuna was observed as ‘BDL’ ( i.e., 0.5 µg/l)
The analysis results of the samples collected from 06 drains reveals that the values
of parameters such as pH, Total Dissolved Solids (TDS), BOD, Chemical Oxygen
Demand (COD), Ammonia (NH3-N), heavy metals such as Cadmium (Cd),
Chromium (Cr), lead (Pb), Total chromium (Cr), Copper (Cu), Iron (Fe), Nickel (Ni),
Lead (Pb) and Zinc (Zn) are in the order of 7.08 to 7.53, 264 to 2780 mg/l, 26 to 567
mg/l, 7 to 567 mg/l, 2.8 mg/l, 0.002 to 0.01 mg/l, 0.02 to 0.35 mg/l, 0.003 to 0.18
mg/l, 2.32 to 16.22 mg/l, 0.003 to 0.11 mg/l, 0.013 to 0.49 mg/l and 0.002 to 2.07
mg/l.
As indicated at section 3.4, the joint inspection teams comprising officials of CPCB,
U.P.Jal Nigam, UPPCB have inspected 317 industries ( increase in one number of
industry as one unit is having secondary unit namely M/s.Silverstone (Unit-II),
Bhopa Road, Muzaffarnagar). 317 industries inspected by the joint inspection teams
are grouped and the industries mainly comprises of pesticides, sugar, distillery, pulp
& paper, tannery/leather, thermal power plant, electroplating, slaughter house/meat
processing, dairy/milk processing, textile and dyeing, pharmaceutical/ayush,
automobile, electrical & electronics, food processing, agro based and remaining
grouped under other categories. Details are given in Table 8.
15
Table 8. Area/District-wise type of Industries (Grouped) located in U.P. State
Name of the Area/District
Industry sector
Muzaffar
Bagpat GB Nagar Ghaziabad G.Noida Meerut Saharanpur Shamli Grand Total
Nagar
Agro Based &
Food - - 01 02 - - - - 03
Processing
Automobile - - 02 04 - - - - 06
Chemical - - 02 - - 02 - - 04
Dairy/Milk - - 01 01 - - 02 - 04
Distillery - - 02 - 01 02 03 01 09
Electrical & - - 05 01 - - - - 06
Electronics
Electroplating/
Phosphating & - - 19 27 - - - - 46
Galvanizing
Engg., Iron and
Steel & Metal - - 28 - - - - - 28
Industries
Others - - 12 - - 02 - - 14
Paint & 01
- - - 01 - - - -
Varnishes
Pesticides - - 01 - - - - - 01
Pharma/ 05
- - 04 - - 01 - -
Ayush
Pulp & Paper - - 04 02 01 29 18 02 56
Slaughter 11
- - 06 01 - 01 03 -
House
Sugar 01 - - - 01 06 04 02 14
Tannery - - 03 02 - 01 - - 06
Textile & 102
- - 80 13 - - 09 -
Dyeing
Thermal Power 01
- 01 - - - - -
Plant
Grand Total 01 01 170 54 03 44 39 05 317
Does not
Sl. Partially Not in
Industrial Sector Operational Closed exists at the Total
No Operational Operation
given address
Agro Based &
1 03 - - - - 03
Food Processing
2 Automobile 06 - - - - 06
3 Chemical 02 - - 02 - 04
4 Dairy 03 - 01 - - 04
5 Distillery 06 01 - 02 - 09
Electrical &
6 04 - - 02 - 06
Electronics
Electroplating,
7 Phosphating & 43 - - 03 - 46
Galvanizing
Engg., Iron and
8 21 01 - 04 02 28
Steel & Metal
16
Industries
9 Paint & Varnishes 01 - - - - 01
10 Pesticides - - 01 - 01
11 Pharmaceutical 05 - - - - 05
12 Pulp & Paper 33 - 07 16 - 56
13 Slaughter House 06 - 05 - - 11
14 Sugar 14 - - - - 14
15 Tannery 05 - 01 - - 06
16 Textile & Dyeing 60 - 22 19 01 102
Thermal Power
17 01 - - - - 01
Plant
18 Others 08 - 01 04 01 14
Grand Total 221 02 37 53 04 317
Industry S.No As
S.No per List of Address of Industry
UPPCB
1 152 Yadav Industries, 7, Anand Ind. Estate, Mohan Nagar Ghaziabad.
New Colour Fashion & Dyeing, S-74, Loni Road Site-74 Loni Road,
2 213 Gzb (Presently, M/s Animesh Graphic Engineers, S-74 Loni Road
Ghaziabad) (Unit Changed)
M/s Sun Labtek Equipments Pvt. Ltd. Loni Road Industries Area
3 216 Ghaziabad was operational instead of Pawan Dyer, S-83 Loni Road
Ind. Area Mohan Nagar Ghaziabad
M/s Santosh Wire industries, C-6 Loni Road, Indl.Area, Mohan Nagar,
4 220 Ghaziabad not existing at this address and instead M/s V.J. Metal
Components Pvt Ltd is in opeartion
6.2 Status of Consents under Water Act, 1974/ Air Act, 1981 and Authorisation
under the Hazardous & Other Waste (Management & Transboundary
Movement) Rules, 2016 as amended
Out of 317 industries, 173 industries are having Consents under Water (Prevention
and Control of Pollution) Act, 1974 and Air (Prevention and Control of Pollution) Act,
1981, 79 industries granted Consents by UPPCB already expired. Similarly, Out of
317 industries, 97 industries are having valid Authorisation whereas 45 industries
authorisation granted under the Hazardous & Other Waste (Management &
Transboundary Movement) Rules, 2016 as amended [H & OW ( M & TM) Rules,
2016 as amended] was observed to be expired. The Status of Consents under
Water & Air Acts and also the Authorisation under the H & OW ( M & TM) Rules,
2016 as amended are given in Table 11 and Table 12.
17
Table 11. District / Area-wise Consent (under Water Act and Air Acts)
Status of industries
Consent (under Water Act and Air Acts)
Status of industries (in numbers)
Table 12. District/Area-Wise Authorization (under [H & OW ( M & TM) Rules, 2016 as
amended ) Status of Industries
6.3 Status of industry-wise water consumption, waste water generation and final
mode of industrial effluent discharge
Most of the industries (252 industries) are extracting water mainly from tube well
/bore well, 02 industries are purchasing water through tankers, 01 industry reported
to be extracting water from Upper Ganga Canal. About 95,270 KLD of water is
consumed by the 255 industries and about 65,646 KLD of wastewater is generated
by 232 industries (based on the information provided by the industry or as reported
by the Joint Inspection Teams). About 32 industries are disposing the generated
wastewater through CETP, 154 industries are discharging either treated or partially
treated waste water into nearby drains which ultimately joins in river Hindon, 06
industries are storing in lagoons within the premises, 49 industries are claiming to be
reused within the industry premises whereas 53 industries are closed, no information
is available from 08 industries, 11 industries are dry process units and 04 industrial
units does not exist at the given address. Industry-wise water consumption, waste
18
water generation and final mode of disposal of generated industrial effluent is given
in Annexure-XI and the area/district-wise total water consumption, waste water
generation and mode of final disposal of industrial effluent is given in Table 13.
Consumption
industrial effluent in KLD
water
Total Water
Industries
S. Name of the Sources generation
Stored in
Lagoon
No District/Area of Water from
in KLD
Reuse
No. of
CETP
Drain
Industries in
KLD
1 Bagpat 01 113 83 - 83 - -
Gautambudh
2 01 7300 2350 2350 - - -
Nagar Tube well/
3 Ghaziabad 170 11524 Bore Well/ 5482* 3145 1431 - 421.35
4 Greater Noida 54 12279 By 8406 4253 4153 - -
Purchase
5 Meerut 03 4043 2273 294 1979 - -
through
Muzaffar tankers/
6 44 37783 26119 16721 7831 1567 -
Nagar Drawn
7 Saharanpur 39 18482 from UGC 17327 13414 1151 2762 -
8 Shamli 05 3746 3605 - 3605 - -
Grand Total 317 95270 65646 40177 20233 4329 421.35
* Quanity of final mode of disposal generated industril effluent is not reported in respect of 11 Industries by the inspection Teams -
484.7 KLD
Also, Area/district-wise water consumption and waste water generation from the
industries is given In Figure 4.
Out of 317 industries, 221 industries are operational. 213 out of 221 industries in
operation have installed ETPs. Out of 213 industries installed ETPs, as observed
during the visit by the teams, 195 industries were operating ETPs and 18 industries
were not operating ETPs, but ETP found to be exists. List of Industries in which ETP
exist but not operational as observed by the joint inspection team is given in Table 14.
19
Table 14. List of Industries in which ETP exist but not operational
Industry
S.No as Type of ETP in
Sl. Date of Operation ETP exist
per Industry Name and Address industrial Operation
No inspection status (Y/N)
UPPCB Sector (Y/N)
List
M/s Bajaj Carpet (P) Ltd., Vill-
1. 19 Habibpur, Noida Dadri Road, Dyeing (Carpet) 08.03.2018 Operational Yes No
Greater Noida
M/s Vikas Wire Industries PLOT Pickling (Wire
2. 44 08.03.2018 Operational Yes No
NO.J- 37 SITE-C, Gr. Noida Drawing)
M/s S.P. WIRE, PLOT NO. G-81, Galvanising &
3. 45 SITE -B, Industrial Area, Pickling (Wire 08.03.2018 Operational Yes No
Gr.Noida Drawing)
Deep Industries Delhi Road, I.E.,
4. 127 Textile Dyeing 07.03.2018 Operational Yes No
Delhi Road, Saharanpur
M/s Lion Cycle & Rickshaw
Industries, E·l0, B.S. Road Ind.
Area Gzb. (Electroplating work is Mudguard
5. 168 12.03.2018 Operational Yes No
stopped since 2017 only Finished
fabrication work is done now
days)
Malik Nidles & Allied Products,
Pvt. Ltd. C-108, Site -1, B.S Hand Sewing
6. 169 11.04.2018 Operational Yes No
Road, Industrial area Ghaziabad Needles
221 out of 317 industries are operational. 72 industries have installed Online
Continuous Effluent Monitoring System (OCEMS), 141 industries have not installed
OCEMS, 06 industries does not require OCEMS being dry process and no
information is available in case of two industries. 65 out of 72 industries have
installed OCEMS and are operational and in case of 07 industries OCEMS exist but
not operational.
20
7.0 Main findings and observations
Based on the analysis results of the samples collected from surface water bodies
which include River Hindon, Krishni, Kali (West), Sheela and River Yamuna as well
as 06 drains contributing to the pollution load in River Hindon followed by River
Yamuna, assessment made by the 52 joint inspection teams w.r.to the status of
compliance to the norms by the 317 industries as well as analysis results of the
groundwater samples collected by the teams, main findings and the observations
are given in the subsequent paras:
To assess the ground water sampling locations suitability for drinking water purpose,
the analysis results of the ground water samples are compared with the Bureau of
Indian Standard Drinking Water Specifications (second revision) IS10500-2012
w.r.to the acceptable limits. The analysis results of the ground water samples
collected from the study area reveals that
Heavy metals such as cadmium, copper, lead, iron, nickel, zinc, mercury and
manganese are exceeding the Bureau of Indian Standard drinking water
specifications (second revision) IS10500-2012 w.r.to the acceptable limits at
4, 5, 14, 33, nil, 04, 39 and 13 locations respectively.
21
complying to IS10500-2012 w.r.to Drinking water standards is given in
Annexure-XII.
For the purpose of analysing the data, the analysis results of the samples collected
from river Hindon, River Krishni, River Kali (West), River Sheela is compared with
the Water Quality Criteria for bathing, whereas the quality of drains is compared with
Schedule-VI General Effluent discharge standards for discharge into inland surface
water notified under the Environment (Protection) Rules, 1986 as detailed below:-
22
The analysis results of the river Hindon, River Krishni, River Kali (West), River
Sheela (given in Annexure -X) and the results reveal that only river Kali
(West) after confluence of river Sheela is complying with water quality criteria
whereas the water samples collected from river Hindon, river Sheela, river
Krishni and river Yamuna at D/s of Tilwara Village ( or A/c of River Hindon
with river Yamuna) are not complying to the water quality criteria for bathing
The analysis results of 06 drain (viz., Khareda Drain, Indirapuram Drain, Hindon
Vihar Drain, Pratap Vihar Drain, Khaila Bhatta Drain, and Kot Escape Drain) samples
[Given at Annexure –X (a)] when compared with Schedule-VI discharge standards
for discharge into inland surface water reveal the following
7.3 Findings on the compliance to the effluent discharge norms by the industries
195 out of 213 industries installed ETPs are operating ETPs whereas 18
industries are not operating the ETPs.
69 out of 195 industries are complying with the effluent discharge norms.
Adopted ZLD/smples not taken by the visited team. 119 industries are not
complying to the effluent discharge norms.
Area/District-wise no. of industries installed ETPs and ETPs operational and the total
no. of industries complying and not complying to the effluent discharge norms is
given in Table 16.
23
Table 16. Area/District-wise no. of industries installed ETPs and ETPs
Operational and the total no. of industries complying and not complying to the
effluent discharge norms
Sl. Total No. of No. of No. of Total
No Industries Industries Industries
installed ETPs complying to complying to
and ETPs the Effluent the Effluent
Name of the Operational Discharge Discharge
District/Area Norms Norms
1 Bagpat 01 - 01 01
2 Gauthambuddh 01 01
Nagar - 01
3 Ghaziabad 91 24 66 90
4 Greater Noida 43 12 30 42
5 Meerut 03 01 01 02
6 Muzaffar Nagar 37 23 12 35
7 Saharanpur 14 05 08 13
8 Shamli 05 04 - 04
Grand Total 195 69 119 188
* 07 No. of Industries either adopted ZLD or Samples Not Taken
No. of Industries
Induatrial Sector
Non Not
(Grouped) Complying Grand Total
Complying Applicable
Agro Based & Food
- 03 - 03
Processing
Automobile 03 02 - 05
Chemical 02 - - 02
Dairy 02 01 - 03
Distillery 01 - 05 06
Electrical & Electronics 01 02 - 03
Electroplating,
Phosphating & 06 28 02 36
Galvanizing
Engg., Iron and Steel &
05 12 - 17
Metal Industries
Others 03 02 - 05
Paint & Varnishes 01 - - 01
Pharmaceutical 02 03 - 05
Pulp & Paper 18 14 - 32
Sloughter House 04 02 - 06
Sugar 07 07 - 14
Tannery 01 04 - 05
Textile & Dyeing 13 38 - 51
Thermal Power Plant - 01 - 01
Total 69 119 07 195
24
List of non-complying industries with respect to effluent discharge norms is annexed
as Annexure-XIV.
25
7.4 General observations and recommendation of the joint inspection teams as
well as expert member of the Committee
Industries are not having valid Consents under Water (Prevention and Control
of Pollution) Act, 1974, Air (Prevention and Control fo Pollution) Act, 1981 as
well as Authorisation under the Hazardous & Other Waste (Management &
Transboundary Movement) Rules, 2016 as amended. Even after applying,
few industries are still awaiting for obtaining Consents from UPPCB. Few
industries have not even obtained Consents but still in operation which is a
serious violation and action is required to be taken by the UPPCB against
such industries.
All the industries have not installed electromagnetic flow meters at the raw
water intake points so as to maintain records with regard to the total
groundwater extraction on daily basis in compliance to the guidelines or NOC
issued by CGWA .
Effluent Treatment Plants (ETPs) are not fitted with flow meters at the inlet
and outlet of ETPs so as to record and measure total inflow (untreated
wastewater) and outflow (ttreated wastewater) from ETPs and either proper
records are maintained with regard to the characterisitcs of treated waste for
assessing consent compliance status as well as to decide final mode of
disposal of treated effluent.
In case of Industries, Consent parameters have been stipulated only for pH,
TSS, BOD and COD by UPPCB, but all the parameters as applicable under
the Environment (Protection) Act, 1986 has not been stipulated by UPPCB.
Also, more stringent effluent norms shall be prescrined by the UPPCB as
empowered under the Water Act, 1974 / Environment (Protection) Act, 1986.
Only major industries like sugar, leather, distillery, thermal power plant,
electroplating units have installed OCEMS. But, all the installed OCEMS are
connected with the CPCB/UPPCB.
Almost all the industrial units except few are using ground water resources as
raw water in the industrial premises which may lead to over exploitation of
26
ground water or may lead to depletion of ground water resources rapidly over
a period of time. Therefore, there is a need to check the permission granted
by Central Ground Water Authority (CGWA) to the industries for extraction of
groundwater for industrial activities keeping in view the protection of
groundwater resources.
-- OO --
28
Annexure-I
CORAM : HON’BLE MR. JUSTICE U.D.SALVI, JUDICIAL MEMBER, ACTING CHAIRPERSON HON’BLE DR. NAGIN
NANDA, EXPERT MEMBER
January 16, In view of the ongoing proceedings and the record produced before us, the
2018
Learned counsel appearing for the applicant submits that these applications being
SS
superfluous are not pressed.
The M.A. No. 192 of 2015 and M.A. No. 193 of 2015
Original Application No. 231 of 2014 and Original Application No. 66 of 2015
These are the applications moved for seeking relief from pollution in:
a) Saharanpur;
29
b) Ghaziabad;
Item No.
14 & 15 c) Samli;
January
d) Meerut;
16, 2018
SS e) Muzaffarnagar and
f) Bagpat.
and anthropogenic.
30
Pesticides causing contamination of groundwater and if
Item No.
14 & 15 so, the remedies therefor. Report of the Committee was
January
expected within two months vide order dated 05 th
16, 2018
2014.
industries therefrom.
noticed:-
1. Sulphide;
2. Fluoride;
3. Mercury;
4. Cadmium;
5. Copper;
6. Zinc;
7. Lead;
8. Iron;
9. Nickel and
31
are also anthropogenic in nature; and certainly one of its
Item No.
14 & 15 component being release of effluents from the industrial
January
activity which in good measure is made of chemical
16, 2018
groundwater.
Laboratory.
32
3. They shall carry out joint inspections of 316
Item No. industries which are listed in the report dated 29 th
14 & 15
Tribunal.
...…..……………………………,ACP
(U.D. Salvi)
...…..…………………………….,EM
(Dr. Nagin Nanda)
33
Annexure-II
34
Annexure-III
35
Item Nos.
18 & 19
May 03,
2018 ...…..…………………………….,JM
(S.P. Wangdi)
A
...…..…………………………….,EM
(Dr. Nagin Nanda)
03.05.2018
36
Annexure-IV
A meeting was convened by the ‘Member Secretary, CPCB’ on 16.02.2018 at 10.30 a.m. in
CPCB Office at Delhi with the Officials of Uttar Pradesh Pollution Control Board (UPPCB)
and U.P. Jal Nigam to discuss issues regarding action to be taken in compliance to the
Hon’ble NGT Order dated 16.01.2018 which include (i) Assessment of Water Quality of
Rivers Viz., Kali, Hindon & Krishni as well as small rivulets and drains meeting Hindon river
in the identified areas; (ii) Assessment of Ground Water Quality in Six Districts viz.
Saharanpur, Ghaziabad, Meerut, Muzaffarnagar, Samli and Bagpat.; (iii) Joint Inspection of
316 Industries located in Six Districts of UP; (iv) Preparation & Finalization of Report and Its
submission to Hon’ble NGT. The list of officials attended the meeting is attached as
Annexure – I.
After having brief introduction by the officials attended the meeting, Dr. R.M.Bharadwaj,
Addl. Director, WQM-I in CPCB welcomed all the officials and informed that the ‘Member
Secretary, CPCB’ as well as Dr.A.B.Akolkar, Ex-Member Secretary (CPCB consultant)
could not attend this meeting in view of the other pre-occupied official engagements.
Thereafter, he informed that this Committee can discuss on the afore-said issues. Firstly,
Dr.Bharadwaj stated that it is important to understand the Hon’ble NGT order so that this
committee can work out action plan for ensuring compliance with all the directions within
two months from the date of order and thereafter, he also read out the order of Hon’ble NGT
(PB) in the matter of O.A. No. 231/ 2014 and O.A. No. 66/ 2015.
The Officials attended the meeting deliberated on the issues which included sampling of
Hindon river in identified districts, sampling of ground water from each district and industries
to be inspected by the joint inspection teams. During the meeting, UPPCB representative
provided the list of 316 industries which are located in the catchment of river Hindon.
Dr.A.K.Vidyarthi, I/c WQM-II, CPCB informed the Committee that in compliance to the
Hon’ble NGT order, the Committee constituted by NMCG already carried out assessment of
water quality of river Hindon, river Kali and river Krishni including drains in the month of
January 2018 and the results are expected soon and he suggested that results can be
included as a part of this Committee also. The representative of Law Cell in CPCB
suggested the committee that action to be taken in compliance to the Hon’ble NGT order
dated 16.01.2018 and if required additional time may be saught from Hon’ble NGT after
appraising the actions initiated. After detailed discussions, deliberations, following decisions
were made by the Committee -
ii) Joint Inspection of 316 industries shall be completed within 15 days from the date of
Constitution of the Joint Inspection Team (s).
37
iii) Assessment of Ground Water Quality in six identified districts shall be carried out by
the teams comprising Officials of CPCB, UPPCB, U P Jal Nigam and U.P. District
Agriculture Office along with the monitoring of the industrial units.
iv) The representative of LO, CPCB was requested to collect the detailed report filed by
CGWA to the Hon’ble NGT.
v) Collected water samples during the inspection shall be submitted at the CPCB (HO)
Laboratory by the respective Joint Inspection Teams members soon after completion
of the visit and the analysis of submitted samples shall be completed by 09 th March,
2018 by CPCB (HO) Laboratory. Thereafter, the inspection reports duly signed by
the inspection team members shall be submitted by 13.03.2018 to the WQM-I
Division, CPCB for compilation and preparation of the interim report/ comprehensive
report
vi) If required, Committee may submit an ‘Interim Report’ on next date of hearing
through Legal Cell in CPCB and may seek additional time for submission of the
detailed report preparation and its submission to the Hon’ble NGT, after approval of
the report by the Committee.
-- 00 --
38
CENTRAL POLLUTION CONTROL BOARD
Parivesh Bhawan, East Arjun Nagar
Delhi – 110032
******
Meeting with UPPCB, U.P Jal Nigam held on 16.02.2018 in CPCB to discuss
Follow –up Action on Hon’ble NGT (PB), New Delhi Order Dated 16.01.2018 in the
matter of O.A. No. 231/2014 and O.A. No. 66/2015’
Attendance Sheet
39
Annexure-V
OFFICE ORDER
No-A-14011/1/2018-MON/2635 23.02.2018
Subject: - Hon’ble NGT (PB), New Delhi order dated 16.1.2018 in the matter of O.A No
231/2014 and O.A No 66/2015 – Joint Inspection of Industries and Assessment of Ground
Water Quality in Identified Six Districts of U.P. State- reg.
Hon’ble NGT (PB) vide order dated 16.1.2018 in the matter of O.A No 231/2014 and O.A No
66/2015, constituted a Committee comprising Central Pollution Control Board, Uttar Pradesh
Pollution Control Board and Uttar Pradesh Jal Nigam and Dr A.B.Akolkar, Ex-Member Secretary,
CPCB to carry out joint inspection of 316 industries identified as well as sampling of surface water
i.e. river Kali, river Hindon, river Krishni and other small rivulets and drains meeting Hindon river as
well as sampling of groundwater in six districts viz. Saharanpur, Ghaziabad, Samli, Meerut,
Muzzafarnagar & Baghpat.
(2) Tentative schedule of joint inspection of 6 (six) no. of identified industries to be inspected and
for sampling of ground water in the identified area by each Joint Inspection Team and the respective
Team Leader is annexed.
(3) During the inspection, the Joint Inspection Team (s) shall collect industrial effluent (ETP),
any other effluent discharge observed, ground water (i.e. hand pump/ bore well/ tube well) samples in
the surrounding vicinity. The collected samples shall be submitted to the CPCB (HO) Labs by the
respective joint inspection team as soon as the visit is completed in a particular day/next day without
fail.
(4) The joint inspection team shall also collect information about the industry such as in
operation/not in operation, product-wise raw material consumption in tonnes per tonne of product,
production and raw materials consumption details in TPA, validity of consents under the Water & Air
Acts or Authorisation under the Hazardous and Other Waste (Management & Transboundary
Movement) Rules, 2008 as applicable, sources of water supply, installation of electromagnetic flow
meters & their readings, water consumption (in KL/ tonne of product), wastewater generation (in KL/
tonne of product), ETP including installation and operation of continuous online emission monitoring
system at the outlet, mode of treated and untreated effluent discharge. The collected information shall
be detailed in the inspection report including main observations made during the visit as well as status
of compliance to the effluent discharge standards. The inspection report shall be submitted by 13th
March, 2018 to I/c WQM-I Div. in CPCB.
(5) TA/DA of officials as a part of the Joint Inspection Team shall be borne by the respective
parent organisation as per entitlement and rules.
(6) The time schedules and the submission of the reports shall be adhered strictly by all the Joint
Inspection Teams.
(7) The monitoring activities will be co-ordinated by WQM-I Division Officials (Shri
R.M.Bharadwaj, I/c WQM-I, M: 9868211284, Shri J.C.Babu, Sc’D’, M: 9868278903 & Smt. Suniti
Parashar, Sc’B’,M: 9868819711)
Sd/-
(A.Sudhakar)
Member Secretary
Encl.: As above
40
Copy to:
8. I/c Instrumentation Lab : For analysis of water samples for heavy metals
Sd/-
(A.Sudhakar)
41
Annexure-V (a)
OFFICE ORDER
No- A-14011/1/2018-MON/47 Date: 26.03.2018
Subject: Hon’ble NGT (PB), New Delhi order dated 16.01.2018 in the matter of O.A No 231/2014 and
O.A No 66/2015 – Joint Inspection of Industries and Assessment of Ground Water Quality in Identified
Six Districts of U.P State - reg.
For any further information please contact Sh. R.M Bhardwaj, I/c WQM-I, M: 9868211284, Sh. J.C Babu,
Sc ’D’, M: 9868278903 & Smt. Suniti Parashar, Sc ‘B’, M: 9868819711
Copy to:
4. I/c F&A Division : For kind information & the expenditure incurred
towards hiring vehicle and special monitoring
allowance/TA/DA as applicable to the Official of Joint
Inspection Team shall be debited from Project Head-I
7. I/c Instrumentation Lab : For analysis of Water Samples for heavy metals
-
(R.M Bhardwaj)
42
Details of Joint Inspection Teams
* Industries to be inspected by Sh. Rathnesh Kumar Sc ’B’; Sh. Y.D Pandey Sc ’B’ as per Office Order No-A-
14011/1/2018-MON dated 23.03.2018 has been distributed to Ms. Smriti Upadhyay Sc’D’; Sh. G.K Ahuja Sc’D’;
and Sh. J.K Bhatia Sc ’B’.
** 4 Industries yet to be inspected by Sh. R.C Rajput Sc ’B’ has been given Sh. Abhas Kumar Maharana Sc ’B’.
43
Annexure-VI
To
The Member Secretary
Uttar Pradesh Pollution Control Board,
Building.No. TC-12V
Vibhuti Khand, Gomti Nagar,
Lucknow – 226010, (U.P)
Subject:- Order of Hon’ble NGT (PB), New Delhi dated 16.1.2018 in the matter of O.A No 231/2014
and O.A No 66/2015
Sir,
Please find enclosed minutes of the meeting held in CPCB on 16.01.2018 for ensuring compliance to
the order of Hon’ble NGT (PB) dated 16.1.2018 in the above mentioned matter of CPCB, UPPCB, Sh A
B Akolkar, Ex-Member Secretary, CPCB and U P Jal Nigam.
As a follow up of the minutes and compliance to Hon’ble NGT (PB) order, the joint inspection team to
carry out inspection of 316 industries (listed in the catchment of river Hindon) is enclosed for
information and record. The inspection of 316 industries is required to be completed by 9th March,
2018.
It is therefore, requested to nominate concerned regional offices of your Board, to associate with the
Committee for joint inspection of identified industries as well as ground water sampling in the
respective areas, to enable to finalise the comprehensive report & its submission by 15th March,2018 to
Hon’ble NGT.
TA/ DA of officials shall be borne by the parent organisation as per the entitlement & rules.
It is also requested to intimate DGP, U P Police for Police protection for the inspection teams for
compliance to para 6 of the Hon’ble NGT (PB) order dated 16.01.2018.
Yours faithfully
Sd/-
(A.Sudhakar)
Member Secretary
Encl: As above
Copy to:-
(2) Regional Director, : For follow up with UPPCB to carry out joint inspection
Central Pollution Control Board, and preparation of Report for submission to Hon’ble
Regional Directorate (North), NGT in compliance to the order dated 16.1.2018
Ground & First Floors,
PIC-UP Bhawan, B-Block,
Vibhuti Khand, Gomti Nagar,
Lucknow-226010
: For kind information please
(4) In-Charge ,WQM-1, CPCB : For kind information and n.a. please.
Sd/-
(A.Sudhakar)
44
Annexure-VII
By /Speed Post
To
Managing Director
U P Jal Nigam
6, Rana Pratap Marg
Lucknow – 226001 (U. P)
Subject:- Order of Hon’ble NGT (PB), New Delhi dated 16.1.2018 in the matter of O.A
No 231/2014 and O.A No 66/2015
Sir,
Please find enclosed minutes of the meeting held in CPCB on 16.01.2018 for ensuring
compliance to the order of Hon’ble NGT (PB) dated 16.1.2018 in the above mentioned matter
of CPCB, UPPCB, Sh A B Akolkar, Ex Member Secretary and U P Jal Nigam.
As a follow up of the minutes and compliance to Hon’ble NGT (PB) order, the joint
inspection team to carry out inspection of 316 industries (listed in the catchment of river
Hindon) is enclosed for information and record. The inspection of 316 industries is required
to be completed by 9th March, 2018.
TA/ DA of officials shall be borne by the parent organisation as per the entitlement & rules.
Yours faithfully
Sd/
(A.Sudhakar)
Member Secretary
Encl: As above
Copy to:-
CPCB
(3) In-Charge ,WQM-1, CPCB :For kind information and n.a. please.
Sd/-
(A.Sudhakar)
45
Annexure-VIII
By Speed Post
To
Member Secretary
Central Ground Water Authority (CGWA)
West Block-2, Wing-3, Sector-1, R. K. Puram
New Delhi-110066
Subject:-Order of Hon’ble NGT (PB), New Delhi dated 16.1.2018 in the matter of O.A No
231/2014 and O.A No 66/2015
Sir,
This has reference to the order of Hon’ble NGT (PB) dated 16.1.2018 in the above mentioned
matter (copy enclosed) wherein Hon’ble NGT has ordered to Constitute a Committee of
CPCB, UPPCB, Sh A B Akolkar, Ex Member Secretary, CPCB and U P Jal Nigam, directing the
said Committee to carry out –
joint sampling of surface water, i.e. river Kali, river Hindon, river Krishni and other
small rivulets and drains meeting Hindon river as well as groundwater of six districts
viz Saharanpur, Ghaziabad, Shamli, Meerut, Muzzafarnagar and Baghpat.
Joint inspection of 316 no. of industries listed in the report filed by UPPCB dated
29.10.2015.
It is requested to kindly arrange for a copy of the earlier submitted by CGWA in compliance
to the previous order of Hon’ble NGT (PB) in the above mentioned matter.
Yours faithfully
Sd/
(A.Sudhakar)
Member Secretary
Encl: As above
Copy to:-
CPCB
(2) In-Charge ,WQM-1, CPCB : For kind information and n.a. please
Sd/-
(A.Sudhakar)
46
Annexure-IX
Water Quality Monitoring Results of Ground Water Samples collected by the Joint Inspection Teams ( Corrected)
Inside Depth of
Date of sample Industry Source of Ground Sulphate Fluoride Cd Cu Pb Fe Ni Zn Mn Hg O&G Total Cr Compliance
S.No Name of the location District GPS Coordinates
collection Premises GW water below (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (µg/l) (mg/l) (mg/l) Status
(Y/N) ground level
Drinking Water Specifications as per IS:10500-2012 (Acceptable Limits) in mg/l 200 1 0.003 0.05 0.01 0.3 0.02 5 0.1 0.001 - 0.05
Site-B, Surajpur, Greater Noida (M.K. 28ᵒ30´27.38” N,
1 Greater Noida 09-03-2018 No Hand Pump 12 m 97 0.6 <0.002 <0.003 <0.013 <0.002 <0.003 <0.002 - <1 2 <0.002 Complying
Leathers) 77.29’ 48.89” E
28°31’50.32”N,
2 Suthyana Village, Dadri road, Habibpur Greater Noida 09-03-2018 No Hand Pump 27 0.6 <0.002 <0.003 <0.013 0.21 <0.003 0.03 - <1 2 <0.002 Complying
77°27’7.74”E
L.G. Electronics, P.No.-51, Udyog Vihar, 28°29’31”N,
3 Greater Noida 04-04-2018 Yes Bore Well 13 m 30 0.8 <0.002 <0.003 <0.013 - <0.003 0.07 0.01 <1 - <0.002 Complying
Greater Noida 77°29’38”E
M.K. Leather Trading Company, D-33, Site B, 28.5076939 N, Non
4 Greater Noida 04-04-2018 Yes Bore Well 8m 134 0.7 <0.002 <0.003 <0.013 - <0.003 0.03 1.03 <1 - <0.002
Surajpur, Greater Noida 77.494639 E Complying
Shree Jagdamba Knits (P) Ltd, P.No.-95,105, 28ᵒ30´46” N, Non
5 Greater Noida 05-04-2018 Yes Bore Well 12 m 123 0.6 <0.002 <0.003 <0.013 - <0.003 0.3 0.1 1.16 - <0.002
Site-B, Surajpur, Greater Noida 77.28’45” E Complying
New Holland Tractors (P) Ltd, Plot Ne.-3, 28.5384794 N,
6 Greater Noida 05-04-2018 Yes Bore Well 10 m 75 0.7 <0.002 <0.003 <0.013 - <0.003 0.01 0.01 <1 - <0.002 Complying
Udyog Kendra, Greater Noida 77.4637655 E
Sky Lark Dyeing (P) Ltd.,Plot No.- B-2/14, Site- 28.513474 N, Non
7 Greater Noida 04-04-2018 Yes Bore Well 30 m 45 0.6 <0.002 <0.003 <0.013 - <0.003 0.03 0.14 <1 - <0.002
B, Surajpur Greater Noida 77.504007 E Complying
Yamaha Motor India (P) Ltd., Noida-Dadri Non
8 Greater Noida 13-03-2018 Yes Bore Well 13 m 47 1.1 <0.002 0.02 <0.013 0.01 <0.003 0.01 <0.002 <1 - <0.002
Road, Greater Noida Complying
Kawatra Papers (P) Ltd., Dhoom Manikpur, 28.55780919 N,
9 Greater Noida 05-04-2018 Yes Bore Well 30 m 92 0.8 <0.002 - <0.013 - <0.003 <0.002 - <1 2 <0.002 Complying
G.T. Road, Dadri 77.5536687 E
M/s Autotech Steel Engineering (P) Ltd, 28.4378824 N, Non
10 Greater Noida 13-03-2018 Yes Bore Well 8.5 m 20 1.2 <0.002 0.05 <0.013 0.43 <0.003 0.05 0.04 <1 - <0.002
Plot.No. 28/3, Ecotech-I, Extn-I,Greater Noida 77.5604753 E Complying
IGL CNG filling station Block I, Beta II, Greater Non
11 Greater Noida 13-03-2018 No Bore Well - - 15 0.6 <0.002 0.06 <0.013 0.05 <0.003 0.19 0.01 <1 - -
noida, U.P. Complying
Non
12 Devla village, Dadri road, Greater Noida Greater Noida 08-03-2018 No Hand Pump - - 40 0.5 <0.002 <0.003 0.26 - <0.003 0.07 - <1 - -
Complying
M/s Garg Tube Co. Ltd. Vill- Chhaproulla, 28.6088728 N, Non
13 Greater Noida 07-03-2018 Yes Borewell 10.26 m 35 0.4 <0.002 <0.003 <0.013 - <0.003 <0.002 - 1.52 2 -
G.T.Road, Gr.Noida 77.4957853 E Complying
Hand Pump of Vishnuli Village, Near Hero 28.6042 N, Non
14 Greater Noida 07-03-2018 No Hand Pump 7.7 m 42 0.5 <0.002 <0.003 <0.013 - <0.003 1.75 - 1.52 - -
Motors 77.4981 E Complying
28.4472 N
15 Hand Pump near village area of Honda Siel Greater Noida 08-03-2018 No Hand Pump 10.5 m 57 0.5 <0.002 <0.003 <0.013 - <0.003 0.28 - <1 - - Complying
77.5434 E
M/s Indo Pump, Plot No-F-29-30, Site- B, 28.5106 N,
16 Greater Noida 08-03-2018 Yes Tube Well 5m 64 0.5 <0.002 <0.003 <0.013 - <0.003 0.01 - <1 2 - Complying
Gr.Noida 77.4995 E
Meeta India Ltd., Plot No 21/2, Site II, Loni 28.6796 N, Non
17 Ghaziabad 11-04-2018 Yes Bore Well 30 m 85 1.7 <0.002 0.003 0.013 - <0.003 0.01 - <1 - -
Road, Mohan Nagar Gzb. 77.381963 E Complying
Mayur Prints, 5/8, Site-Z, Loni Road Mohan 28.71058 N,
18 Ghaziabad 11-04-2018 Yes Bore Well - 50 0.9 <0.002 0.003 0.013 - <0.003 0.01 - <1 - - Complying
Nagar Gzb. 77.21356 E
Micro Gartex Industries, C·2, Loni Road Ind. 28.7123 N,
19 Ghaziabad 12-04-2018 Yes Bore Well 28 m 53 0.4 <0.002 0.003 0.013 - <0.003 0.04 - <1 - - Complying
Area Gzb. 77.4013 E
M/s Jayanita Export (P) Ltd. PLOT NO. A-1,
28.42 N,
20 EPIP, KASNA, G.NOIDA Greater Noida 09-03-2018 Yes Bore Well 10 m 47 0.7 <0.002 0.003 0.013 - <0.003 <0.002 - <1 - 0.01 Complying
77.54 E
47
Inside Depth of
Date of sample Industry Source of Ground Sulphate Fluoride Cd Cu Pb Fe Ni Zn Mn Hg O&G Total Cr Compliance
S.No Name of the location District GPS Coordinates
collection Premises GW water below (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (µg/l) (mg/l) (mg/l) Status
(Y/N) ground level
Drinking Water Specifications as per IS:10500-2012 (Acceptable Limits) in mg/l 200 1 0.003 0.05 0.01 0.3 0.02 5 0.1 0.001 - 0.05
M/s J.M.V.L.P.S. Ltd., (Ex Name J.M.V.
28°31’14”N, Non
21 Earthing Equipment pvt. Ltd) Plot No- J-12, Greater Noida 12-03-2018 Yes Bore Well 12 m 111 0.8 <0.002 0.22 0.013 - <0.003 0.15 - <1 - -
77°30’57”E Complying
Site-C, UPSIDC, GR. NOIDA
M/s JBM Autotech, PLOT NO-J- 5, SITE -C , 28.53 N, Non
22 Greater Noida 12-03-2018 Yes Bore Well 12 m 229 0.6 <0.002 0.01 0.013 - 0.01 <0.002 - <1 - -
Gr.Noida 77.51 E Complying
M/s Material Movellindia (P) Ltd, Plot.No.G- 28.25 N,
23 Greater Noida 09-03-2018 Yes Bore Well 10 m 31 0.4 <0.002 0.003 0.013 - <0.003 <0.002 - <1 - 0.01 Complying
86/1, Site-S, UPSIDC, Gr. Noida 77.33 E
Nippon Tube Ltd, Bisrakh Road, Vill- 28°36’57”N,
24 Greater Noida 12-03-2018 Yes Bore Well 13 m 27 0.5 <0.002 <0.003 <0.013 - <0.003 0.09 -- <1 - <0.002 Complying
Chapraulla, Gr.Noida. 77°28’22”E
M/s Bir Horizons Pvt. Ltd. ,PLOT NO.F-79, 28°30’40.6”N, Non
25 Greater Noida 08-03-2018 Yes Bore Well 60 0.7 <0.002 <0.003 <0.013 <0.002 <0.003 <0.002 0.16 <1 - -
SITE-B, Surajpur, Gr.Noida 77°29’47.6”E Complying
Non
26 Nangla Dairy Greater Noida 08-03-2018 Yes Hand Pump - 50 m 18 0.6 <0.002 <0.003 <0.013 1.29 <0.003 0.14 0.06 <1 - <0.002
Complying
Near M/S Asian Paints Ltd., PLOT NO-A-l, 28.4355857 N,
27 Greater Noida 09-03-2018 No Hand Pump 7.5 m 20 0.7 <0.002 <0.003 <0.013 - <0.003 1.34 - <1 2 - Complying
UPSIDC, industrial Area, Site- 5, GR. NOIDA 77.5509382 E
Temple near M/s Bajaj Hindustan Ltd, Sugar 29°01” N
28 Meerut 05-03-2018 No Hand Pump 17 m - 0.7 <0.002 <0.003 <0.013 - <0.003 0.33 - <1 - - Complying
Unit, Kinoni, Meerut 77°45” E
29.127228 N, Non
29 Village Mandhiyai, Meerut Main Road Meerut 05-03-2018 No Hand Pump 83 m - 1.1 <0.002 <0.003 <0.013 - <0.003 0.11 - <1 - -
77.608529 E Complying
Hand Pump Near M/s Ramala Sahkari Chini 29.235139 N, Non
30 Baghpat 07-03-2018 No Hand Pump 16 m - 1.1 <0.002 <0.003 ,0.013 - <0.003 1.16 - <1 - -
Mills Ltd, Ramala, Bagpat 77.284237 E Complying
Inside Parmedical College Premises, Village 29°28’61.91”N Non
31 Muzaffarnagar 07-03-2018 No Hand Pump 44 m - 0.3 0.74 <0.003, 0.28 - <0.003 2.95 - <1 - -
Bagra 77°55’58”E Complying
Near M/s Bajaj Hindustan Ltd. Bhaisana, 29.294250, Non
32 Muzaffarnagar 07-03-2018 No Hand Pump 50 m - - 0.12 <0.003 <0.013 - <0.003 1.96 - 1.52 - -
Muzaffarnagar 77.493759 Complying
33 Khampur, Rohana Kalan, Roorkee Road Muzaffarnagar 08-03-2018 No Hand Pump - 50 m 29 0.1 <0.002 <0.003 <0.013 - <0.003 0.03 - <1 - - Complying
29°21'18.8" N, Non
34 Main road, Mansurpur village Muzaffarnagar 06-03-2018 No Hand Pump 50 m 52 0.3 <0.002 <0.003 <0.013 - <0.003 0.15 - 1.3 2 -
77°42'50.1" E Complying
35 Village Phalawda, Main Road Muzaffarnagar 08-03-2018 No Hand Pump - 50 m 18 0.2 <0.002 <0.003 <0.013 - <0.003 0.19 - <1 - - Complying
36 Dhabdheda Village, Jolly Road Muzaffarnagar 08-03-2018 No Hand Pump - 50 m 34 0.3 <0.002 <0.003 <0.013 - <0.003 0.81 - <1 - - Complying
29°16’44.4”N, Non
37 Tehsil Katauli Muzaffarnagar 06-03-2018 No Hand Pump 50 m 14 0.3 <0.002 <0.003 <0.013 - <0.003 0.09 - 1.3 2 -
77°44’19.4”E Complying
Non
38 Mansurpur NH 58 on road Muzaffarnagar 06-03-2018 No Hand Pump - 50 m 76 0.3 <0.002 <0.003 <0.013 - <0.003 9.12 - 1.26 2 -
Complying
Opposite Hindon Airforce Station, Police 28.6878800 N,
39 Muzaffarnagar 09-04-2018 No Hand Pump 50 m 53 0.6 <0.002 <0.003 <0.013 - <0.003 0.81 - <1 2 - Complying
Check Post, Loni Road 77.3752400 E
Tube Well near of M/s Silvertone Paper Ltd 29°28’ 00.15’’ N, Non
40 Muzaffarnagar 16-04-2018 No Tube Well 18.29 m 208 0.3 <0.002 <0.003 <0.013 - <0.003 <0.002 - <1 - -
(Init 1) Bhopa Road, Muzaffarnagar 77 °47’05.60’’ E Complying
Handpump outside(within 500 mt radius) the
29°25’ 09.8’’ N,
41 premises of M/s Shalimar Paper (p) Ltd. Muzaffarnagar 12-04-2018 No Hand Pump 20 m 111 0.1 <0.002 <0.003 <0.013 - <0.003 0.55 - <1 - - Complying
77°45’ 38.0’’ E
Bhopa road, Muzaffarnagar
Handpump outside the premises of M/S 29°28’’6.42' N
42 Muzaffarnagar 12-04-2018 No Hand Pump 18.29 m 18 0.3 <0.002 <0.003 <0.013 - <0.003 0.4 - <1 2 - Complying
Bindalas Duplex Ltd, (Unit-1), Muzaffarnagar 77°48’’22.53' E
Handpump outside the premises of M/S
Shakumbari Pulp & Paper Bhopa road 29.4704 N,
43 Muzaffarnagar 12-04-2018 No Hand Pump 18.29 m 72 0.2 <0.002 <0.003 <0.013 - <0.003 0.05 - <1 - - Complying
Muzaffarnagar 77.73412 E
48
Inside Depth of
Date of sample Industry Source of Ground Sulphate Fluoride Cd Cu Pb Fe Ni Zn Mn Hg O&G Total Cr Compliance
S.No Name of the location District GPS Coordinates
collection Premises GW water below (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (µg/l) (mg/l) (mg/l) Status
(Y/N) ground level
Drinking Water Specifications as per IS:10500-2012 (Acceptable Limits) in mg/l 200 1 0.003 0.05 0.01 0.3 0.02 5 0.1 0.001 - 0.05
Ms. N.S. Papers Ltd. [Unit-I], Jansath Road,
44 Muzaffarnagar 09-04-2018 Yes Bore Well - 100 m 131 0.3 <0.002 <0.003 <0.013 - <0.003 <0.002 - <1 - - Complying
Muzaffar Nagar
M/S Mahalaxmi Craft & Tissues, 9th Km,
45 Muzaffarnagar 09-04-2018 Yes Bore Well - 75 m 24 0.1 <0.002 <0.003 <0.013 - <0.003 <0.002 - <1 - - Complying
Jansath Road
M/S Aggarwal Duplex & Board Mills Ltd., 4th 29 28 27 N
46 Muzaffarnagar 09-04-2018 Yes Bore Well 23 m 4 0.5 <0.002 <0.003 <0.013 - <0.003 <0.002 - <1 - - Complying
Km, Bhopa Road 77 44 26.1 E
M/S Tirupati Balajl Fibers Ltd. 9th Km, Bhopa 29 28 18 N
47 Muzaffarnagar 11-04-2018 Yes Bore Well 13 m 9 0.4 <0.002 <0.003 <0.013 - <0.003 <0.002 - <1 - - Complying
Road 77 44 17.1 E
M/S Meenu Papers (P) Ltd., 9.5 Km, Bhopa
48 Muzaffarnagar 11-04-2018 Yes Bore Well - 40 m 88 0.3 <0.002 <0.003 <0.013 - <0.003 <0.002 - <1 - - Complying
Road, Muzaffarnagar
Industry premises of M/S Tehri Pulp & Papers
29.471 N, Non
49 Ltd. (Unit-I), 9th Km Stone, Bhopa Road, Muzaffarnagar 12-04-2018 Yes Bore Well E 40 m 4 0.5 <0.002 <0.003 <0.013 - <0.003 0.05 - 1.26 - -
77.796 Complying
Muzaffarnagar
M/S Suyash Craft & Papers Ltd.Village- 29.426 N, Non
50 Muzaffarnagar 13-04-2018 Yes Bore Well 40 m 11 0.3 <0.002 <0.003 <0.013 - <0.003 0.14 - 1.01 - -
Velhana, Meerut Roadf, Muzaffarnagar 77.692 E Complying
Industry premises of M/S Shri Bhageshwari 29.472 N, Non
51 Muzaffarnagar 12-04-2018 Yes Bore Well 45 m 6 0.3 <0.002 <0.003 <0.013 - <0.003 0.01 - 1.52 - -
Paper Mills (P) 77.491 E Complying
Industry Premises of M/s Sidhbali Papers mills 29.471 N,
52 Muzaffarnagar 13-04-2018 Yes Bore Well 45 m 49 0.3 <0.002 <0.003 0.03 - <0.003 0.22 - <1 - - Complying
Ltd,), 45-B, new mandi, Muzaffarnagar 77.784 E
Near M/s. Arihant Pulp & Papers Ltd., 29.437478 N, Non
53 Muzaffarnagar 08-03-2018 No Hand Pump 13 m 41 0.3 <0.002 <0.003 <0.013 10.42 <0.003 1.9 0.09 <1 - <0.002
opposite cement godwon, musa bilaspur 77.745673 E Complying
Near M/s Siddeshwari industries Pvt. Ltd., 8.6 29°25’8”N, Non
54 Muzaffarnagar 08-03-2018 No Hand Pump 61 m 30 0.1 <0.002 <0.003 <0.013 0.17 <0.003 <0.002 0.87 - - <0.002
Km Jansath Road, Muzaffarnagar 77°45’36”E Complying
M/s K.K. Duplex & Paper mill Pvt. Ltd., 8.5 Km 29°42’37.38”N, Non
55 Muzaffarnagar 08-03-2018 Yes Bore Well 46 m 43 0.1 <0.002 <0.003 <0.013 0.09 <0.003 <0.002 0.23 - - <0.002
Stone, Jansath Road, Muzaffarnagar 77°75’87.43”E Complying
M/s Silver Tone Pulp & Paper, 9th Km Stone, 29°27’59.8”N, Non
56 Muzaffarnagar 08-03-2018 Yes Bore Well 70 m 25 0.5 <0.002 <0.003 <0.013 0.01 <0.003 <0.002 0.27 - - <0.002
Bhopa Road, Muzaffarnagar. 77°47’17”E Complying
M/S Bindal Papers Ltd. Bhopa Road, 29.473574 N,
57 Muzaffarnagar 08-03-2018 Yes Bore Well 13 m 5 0.3 <0.002 <0.003 <0.013 0.11 <0.003 <0.002 0.02 - - <0.002 Complying
Muzaffarnagar. 77.786736 E
M/s Disha Industries ltd., 9th Km, Jolly Road, 29.444213 N,
58 Muzaffarnagar 08-03-2018 Yes Bore Well 25 m 30 0.2 <0.002 <0.003 <0.013 0.01 <0.003 <0.002 0.1 - - <0.002 Complying
Vill- Sikhrera, Muzaffarnagar 77.788132 E
M/s. Galaxy Papers Pvt. ltd., 9.4 Km Jolly 29.4419536 N,
59 Muzaffarnagar 15-03-2018 Yes Tube Well 53 m 51 0.1 <0.002 <0.003 <0.013 - <0.003 0.18 - - - - Complying
Road, Vill- Dhandhara, Muzaffarnagar 77.7784556 E
Near M/s. Shaktl Kraft & Tissues Pvt. Ltd., 9th 29.4196631 N,
60 Muzaffarnagar 15-03-2018 No Hand Pump 53 m 45 0.1 <0.002 <0.003 <0.013 - <0.003 0.01 <0.002 - - - Complying
Km, Jansath Road,Muzaffarnagar 77.7605193 E
Near M/s Magma Industries Ltd., C-27
29.372485 N,
61 UPSIDC Industrial Area, Begrajpur, Muzaffarnagar 15-03-2018 No Hand Pump 53 m 43 0.2 <0.002 <0.003 <0.013 - <0.003 0.12 - <1 2 - Complying
77.705181 E
Muzaffarnagar
Near M/s Nikita Papers P.Ltd., C-10,
62 Shamli 12-04-2018 No Hand Pump - - 29 0.7 <0.002 <0.003 0.03 - <0.003 1.78 - <1 2 - Complying
Ind.Estate, Panipat road, Shamli
Near M/s.Maruti Papers Pvt.Ltd., Village
63 Shamli 12-04-2018 No Hand Pump - - 2 0.6 <0.002 <0.003 <0.013 - <0.003 1.66 - <1 2 - Complying
Sikka, Shamli
Near M/s. Ravi Organics Ltd., Begrajpur, Non
64 Muzaffarnagar 13-04-2018 No Hand Pump - - 20 0.2 <0.002 <0.003 <0.013 - <0.003 0.89 - 1.26 2 -
Muzaffarnagar Complying
M/s. H.J. Tannery ,9th Km, Jansath Road,
Non
65 Muzaffarnagar Muzaffarnagar 13-04-2018 Yes Tube Well - - 41 0.2 <0.002 <0.003 <0.013 - <0.003 <0.002 - 1.01 - -
Complying
49
Inside Depth of
Date of sample Industry Source of Ground Sulphate Fluoride Cd Cu Pb Fe Ni Zn Mn Hg O&G Total Cr Compliance
S.No Name of the location District GPS Coordinates
collection Premises GW water below (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (µg/l) (mg/l) (mg/l) Status
(Y/N) ground level
Drinking Water Specifications as per IS:10500-2012 (Acceptable Limits) in mg/l 200 1 0.003 0.05 0.01 0.3 0.02 5 0.1 0.001 - 0.05
Meerut Karnal road, Near Bypass Shamli
29.442825 N, Non
66 Shamli 06-04-2018 No Hand Pump 60 m 32 0.8 <0.002 <0.003 <0.013 - <0.003 0.66 - 1.33 - -
77.314561 E Complying
50m away from M/s Bajaj Hindustan Ltd., 29.5693 N, Non
67 Shamli 07-04-2018 No Hand Pump - 2 0.4 <0.002 <0.003 <0.013 - <0.003 0.24 - 1.16 - -
Thanabhawan, Muzaffarnagar 77.408405 E Complying
Near M/s. Shamli Distillery & Chem.Work, 29.442825 N, Non
68 Shamli 06-04-2018 No Hand Pump 60 m 32 0.8 <0.002 <0.003 <0.013 - <0.003 0.66 - 1.33 - -
Shamli 77.314561 E Complying
Gauthambuddh 28.597831 N,
69 M/s NTPC Ltd, Dadri, Gauthambuddh nagar 05-04-2018 Yes Hand Pump 12 m 57 0.8 - - - - - 0.11 - <1 - <0.002 Complying
Nagar 77.614034 E
Outside M/s NTPC Ltd, Dadri, Gauthambuddh Gauthambuddh
70 05-04-2018 No Hand Pump - 10 m 63 0.3 <0.002 <0.003 <0.013 - <0.003 0.06 - <1 - - Complying
nagar, Muthani Gate Nagar
29°55’08.4”N,
71 M/s Co-operative Co. Ltd., Tapri, Saharanpur Saharanpur 09-04-2018 Yes Bore Well 60 m 10 0.8 <0.002 <0.003 <0.013 - <0.003 0.16 - <1 - - Complying
77°35’50.9”E
Outside M/s Co-operative Co. Ltd., Tapri, 29554’57.3”N, Non
72 Saharanpur 09-04-2018 No Hand Pump 35 m 122 0.2 <0.002 <0.003 0.013 - <0.003 6.63 - <1 - -
Saharanpur 77°35’40.0”E Complying
U.P. Co-orperative Sugar Factory, Nanouta, 29°42’31.3”N,
73 Saharanpur 09-04-2018 Yes Hand Pump 40 m 190 0.5 <0.002 <0.003 <0.013 - <0.003 <0.002 - <1 - - Complying
Saharanpur 77°26’52.1”E
Outside U.P. Co-orperative Sugar Factory, 29.711202 N,
74 Saharanpur 09-04-2018 No Hand Pump 35 m 19 0.9 <0.002 <0.003 <0.013 - <0.003 0.02 - <1 - - Complying
Nanouta, Saharanpur 77.448998 E
Bajaj Hindustan Ltd., Distillery Unit, Village -
75 Saharanpur 10-04-2018 Yes Hand Pump - 35 m 180 0.8 <0.002 <0.003 <0.013 - <0.003 0.02 - <1 - - Complying
Gangoli, Saharanpur
Outside Bajaj Hindustan Ltd., Distillery Unit,
76 Village -Gangoli, Saharanpur Saharanpur 10-04-2018 No Hand Pump - 35 m 29 0.2 <0.002 <0.003 <0.013 - <0.003 0.16 - <1 - - Complying
50
Inside Depth of
Date of sample Industry Source of Ground Sulphate Fluoride Cd Cu Pb Fe Ni Zn Mn Hg O&G Total Cr Compliance
S.No Name of the location District GPS Coordinates
collection Premises GW water below (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (µg/l) (mg/l) (mg/l) Status
(Y/N) ground level
Drinking Water Specifications as per IS:10500-2012 (Acceptable Limits) in mg/l 200 1 0.003 0.05 0.01 0.3 0.02 5 0.1 0.001 - 0.05
Near M/s Arora Hoiesery, Janta Road, 29.973331 N,
88 Saharanpur 15-03-2018 No Tube Well - 56 0.1 <0.002 <0.003 <0.013 - <0.003 <0.002 - <1 2 - Complying
Saharanpur 77.574976 E
Near M/s Atul Textile Industried Ltd., 29.985548 N, Non
89 Saharanpur 07-03-2018 No Hand Pump 55 m 11 0.3 <0.002 <0.003 <0.013 - <0.003 1.76 - 1.01 2 -
Shakumabari Vihar, Behat Road, Saharanpur 77.568758 E Complying
Near M/s Shalimar Cotton Dyeing,
29.996889 N, Non
90 Saharanpur Behat Road, Rasulpur, Saharanpur 07-03-2018 No Hand Pump 55 m 220 0.3 <0.002 <0.003 <0.013 - <0.003 <0.002 - 1.51 2 -
77.566726 E Complying
Saharanpur
Near M/s S.M.C. Foods Ltd. Nnauta, 28°54’11.5”N, Non
91 Saharanpur 07-03-2018 No Hand Pump 15.2 m 33 0.3 <0.002 <0.003 <0.013 - <0.003 0.57 - 1.51 2 -
Saharanpur 77°50’54.5”E Complying
M/s Pashupati Dairy (P) Ltd. Village Non
92 Saharanpur 17-04-2018 Yes Bore Well - 60 m 27 0.3 <0.002 <0.003 <0.013 <0.002 <0.003 <0.002 0.29 - - <0.002
Kumharhera, Dehradun Road, Saharanpur Complying
93 M/s Shree Krishna Board Mill Dehradun Saharanpur 17-04-2018 Yes Tube Well - - 16 0.4 <0.002 <0.003 <0.013 <0.002 <0.003 0.08 <0.002 - <0.002 Complying
Near Saharanpur Paper Board Mill, Village- 29.976993 N,
94 Saharanpur 04-04-2018 No Hand Pump 37 m 7 0.2 <0.002 <0.003 <0.013 - <0.003 1.07 - <1 2 - Complying
Majri, Dehradun Road, Saharanpur 77.648367 E
95 Near M/s Jagadamba Gramodyog Sansthan Saharanpur 04-04-2018 No Hand Pump - 35 m 14 0.2 <0.002 <0.003 <0.013 - <0.003 0.05 - <1 2 - Complying
Near M/s Jayna Gramodyaog Sansthan, 29.983602 N, Non
96 Saharanpur 04-04-2018 No Hand Pump 35 m 19 0.1 <0.002 <0.003 <0.013 - <0.003 6.07 - <1 2 -
Gagalheri 77.665811 E Complying
Near M/s Tiwaya File Board Mill, Nawada 29.999723 N,
97 Saharanpur 04-04-2018 No Hand Pump 35 m 3 0.3 <0.002 <0.003 <0.013 - <0.003 1.22 - <1 2 - Complying
Road, Saharanpur 77.642866 E
Near M/s Star Gramodyaog Sansthan, 29.950706 N,
98 Saharanpur 05-04-2018 No Hand Pump 35 m 20 0.1 <0.002 <0.003 <0.013 - <0.003 0.002 - <1 2 - Complying
Manakmau, 77.507566 E
29.979749 N, Non
99 Gagalheri, Dehradun, Saharanpur Saharanpur 05-03-2018 No Hand Pump 44 m 5 0.6 <0.002 0.15 0.09 - <0.003 1.05 - <1 - -
77.668548 E Complying
M/s Balaji Wire Pvt. Ltd., 139·A, Anand 28.674894 N, Non
100 Ghaziabad 07-03-2018 Yes Hand Pump 45 m 89 0.5 <0.002 <0.003 <0.013 0.12 <0.003 0.39 - 1.72 - <0.002
Industrial Estate Mohan Nagar, Gzb. 77.388494 E Complying
Mohan Meakins Ltd., Mohan Nagar, 28°40’17.5”N Non
101 Ghaziabad 08-03-2018 Yes Bore Well 25 m 96 0.8 <0.002 0.01 0.04 <0.002 <0.003 <0.002 - 1.01 - <0.002
Ghaziabad 77°23’01.0”E Complying
Near M/s AB Cycle Parts Pvt. Ltd. at Ispat
28°38’23.6”N Non
102 Nagar, Buland Sahar Road Industrial Area, Ghaziabad 08-03-2018 No Hand Pump 40 m 71 0.5 <0.002 <0.003 0.08 6.28 <0.003 1.24 - <1 2 0.02
77°26’37.6”E Complying
Ghaziabad.
Near Balaji Enterprises, B-22/1/15, B.S.Road 28.6484380 N, Non
103 Ghaziabad 13-03-2018 No Hand Pump - 135 0.4 <0.002 <0.003 <0.013 0.72 <0.003 0.27 - - 2 <0.002
Ind. Area Gzb. 77.4594966 E Complying
28.6484381 N, Non
104 Near Indian Textiles Co., E-49, B.S. Road, Gzb. Ghaziabad 09-03-2018 No Hand Pump - 330 0.8 <0.002 0.01 <0.013 1.47 <0.003 0.11 - <1 - -
77.4594767 E Complying
Near M/s Lion Cycle & Rikshaw Industries, 28.6424919 N, Non
105 Ghaziabad 12-03-2018 No Hand Pump - 109 0.7 <0.002 <0.003 <0.013 <0.002 <0.003 0.002 - 1.01 - -
E·l0, B.S. Road Ind. Area Gzb. 77.4609803 E Complying
Near Progressive Tools & Component Pvt.Ltd. 28.642382 Non
106 Ghaziabad 03-04-2018 No Handpump 46m 203 0.6 <0.002 <0.003 <0.013 0.72 <0.003 0.27 - <1 - -
C-222, B.S. Road Ind. Area , Gzb 77.460819 Complying
28.649171
107 Hapur Bypass Road Ghaziabad 03-04-2018 No Handpump 42m 45 0.4 <0.002 <0.003 <0.013 0.07 <0.003 0.03 - <1 - - Complying
77.468453
Within the premises of Golden Height 28 66'N,
108 Ghaziabad 12-03-2018 No Bore Well 175 m 5 0.5 <0.002 <0.003 <0.013 - <0.003 0.05 - <1 2 <0.002 Complying
Academy (Primary School) 77 46' E
From tube well situated in premises of Masjid
28.639554 N, Non
109 , besides the road towards the unit M/s Ghaziabad 11-04-2018 No Hand pump - 35 0.5 <0.002 <0.003 <0.013 - <0.003 0.02 - 1.83 2 <0.002
77.446274 E Complying
Shivam Engineering and Fabrication
Near M/s Tarun International C-15, SS of GT 28.6377376 N, Non
110 Ghaziabad 05-04-2018 No Bore well - 44 0.4 <0.002 <0.003 <0.013 0.13 <0.003 0.002 0.21 1.16 2 <0.002
road, Ghaziabad 77.44111755 E Complying
51
Inside Depth of
Date of sample Industry Source of Ground Sulphate Fluoride Cd Cu Pb Fe Ni Zn Mn Hg O&G Total Cr Compliance
S.No Name of the location District GPS Coordinates
collection Premises GW water below (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (µg/l) (mg/l) (mg/l) Status
(Y/N) ground level
Drinking Water Specifications as per IS:10500-2012 (Acceptable Limits) in mg/l 200 1 0.003 0.05 0.01 0.3 0.02 5 0.1 0.001 - 0.05
M/s Exclusive leathers, Khasara No, 2751,
111 Ghaziabad 06-04-2018 Yes Bore well - 33 m 48 0.7 <0.002 <0.003 <0.013 - <0.003 0.002 - <1 2 - Complying
Bhoorgarhi Dasna , Ghaziabad
M/s Eagle Continental foods pvt ltd, Dasna 28.688341 N,
112 Ghaziabad 05-04-2018 Yes Bore well 30 m 44 0.7 <0.002 <0.003 <0.013 <0.002 <0.003 0.03 0.01 <1 2 <0.002 Complying
Ghaziabad 77522666 E
M/s AI-Naseer Export Pvt. Ltd., Khasara no
28.6846923 N,
113 2761 & 2762 ViII- Bhoorgarhi Dasna, Ghaziabad 06-04-2018 Yes Bore well 33 m 36 0.8 <0.002 <0.003 <0.013 - <0.003 0.65 - <1 2 - Complying
775316609 E
Ghaziabad
M/s Al Nafees Frozen Foods Export, Hapur 28.685079 N, Non
114 Ghaziabad 06-04-2018 Yes Hand Pump 13 m 56 1 <0.002 <0.003 <0.013 - <0.003 0.65 - 1.66 2 -
Rd. Dasna Ghaziabad 77.540928 E Complying
1km away from M/s International agro Foods
(Integrated slaughter House) Plot no. 2764 - 28.684528,
115 Ghaziabad 08-03-2018 Yes Borewell 37m 43 0.6 <0.002 <0.003 <0.013 0.02 <0.003 0.14 - - - <0.002 Complying
2766, Bhurgardi, Dasna, Distt. Ghaziabad 77.5435
Uttar Pradesh
M/s International agro Foods (Integrated
slaughter House) Plot no. 2764 - 2766, Non
116 Ghaziabad 08-03-2018 Yes Borewell - 29 m 30 1.3 <0.002 <0.003 <0.013 0.1 <0.003 0.24 - - - <0.002
Bhurgardi, Dasna, Distt. Ghaziabad Uttar Complying
Pradesh
Non
117 Dasna Village Ghaziabad 08-03-2018 No Borewell - - 40 0.6 <0.002 <0.003 0.02 1.77 <0.003 0.04 - - - <0.002
Complying
Non
118 Bhurgadi Village (Private) Ghaziabad 08-03-2018 No Borewell - - 136 2.5 <0.002 <0.003 <0.013 1.56 <0.003 1.56 - - - 0.05
Complying
Non
119 Bhurgadi Village(Government) Ghaziabad 08-03-2018 No Borewell - - 41 0.7 <0.002 <0.003 <0.013 1.84 <0.003 0.21 - - - 0.26
Complying
Rajeev Colony, adject to M/s Ambica Steels 28.682150 N, Non
120 Ghaziabad 08-03-2018 No Hand Pump 33 m 26 2.4 <0.002 <0.003 <0.013 0.002 <0.003 1.09 - <1 - <0.002
Ltd., Mohan Nagar Ghaziabad 77.381735 E Complying
M/s Bansal Wire Industries Ltd, B-3, Loni Non
121 Ghaziabad 07-03-2018 No Hand Pump Ghaziabad - 95 0.5 <0.002 0.05 <0.013 1.33 0.02 8.58 - <1 - <0.002
road, Mohan Nagar, Ghaziabad, U.P. Complying
The Kisan Sahakari Chini Mill, Nanouta, 29.4237N, Non
122 Saharanpur 11-04-2018 Yes Hand Pump 50 m 19 0.4 <0.002 <0.003 0.07 11.26 <0.003 4.15 0.16 - - <0.002
sahranpur UP 77.2644E Complying
29.5749N, Non
123 Daya Sugar Gagalheri, Saharanpur, U.P Saharanpur 10-04-2018 Yes Hand Pump 30 m 2 0.2 <0.002 <0.003 <0.013 9.9 <0.003 1.79 0.05 - - <0.002
77.3934E Complying
Triveni Engg. & Industires Ltd., Deoband, 29.4020N, Non
124 Saharanpur 10-04-2018 Yes Hand Pump 30 m 176 0.5 <0.002 <0.003 <0.013 8.83 <0.003 1.34 0.21 - - <0.002
saharanpur, U.P 77.4099E Complying
Bajaj Hindustan Sugar Ltd., Gangoli 29.4835N, Non
125 Saharanpur 10-04-2018 Yes Hand Pump 30 m 16 0.1 <0.002 <0.003 <0.013 2.77 <0.003 1.1 0.17 - - <0.002
Saharanpur, U.P 77.3258E Complying
Vaishali Hosiery, 1-17, Sector D-1, Apparel Non
126 Ghaziabad 19-04-2018 Yes Borewell - 30 m 49 0.4 <0.002 1.25 <0.013 <0.002 0.02 0.3 - <1 - -
Park, Tronica City, Loni, Gzb. Complying
Vedanta Estate, I-11, Apparel Park, Sector D-
127 Ghaziabad 19-04-2018 Yes Borewell - 30 m 157 0.3 <0.002 <0.003 <0.013 - <0.003 0.002 - <1 - - Complying
1(P3), Tronica City, Loni. Gzb.
Sunny Prints, 5/7, Site-II Industrial Area, Loni 28,41,10 N Non
128 Ghaziabad 09-03-2018 Yes Bore Well 35 m 122 0.8 <0.002 <0.003 <0.013 - <0.003 <0.002 - 1.01 10 -
Road, GZB. 77,22,53E Complying
Yadav Industries, C-11, Loni Road Ind.Area 28,40,53 N
129 Ghaziabad 09-03-2018 Yes Bore Well 30 m 19 0.3 <0.002 <0.003 <0.013 - <0.003 <0.002 - <1 - - Complying
Gzb. 77,23,23E
Agarwal Galvanizing, Unit-2, A-8/6, Meerut 28,42,11N
130 Ghaziabad 08-03-2018 Yes Bore Well 30 m 26 0.5 <0.002 <0.003 <0.013 - <0.003 <0.002 - <1 2 - Complying
Road Ind. Area Guldar Ghaziabad 27,22,23E
Albert David Ltd., B-13, Meerut Road 28,41,05N Non
131 Ghaziabad 08-03-2018 Yes Bore Well 30 m 33 0.5 <0.002 <0.003 <0.013 - <0.003 <0.002 - 1.52 - -
industrial Area Ghaziabad. 77,26,10E Complying
52
Inside Depth of
Date of sample Industry Source of Ground Sulphate Fluoride Cd Cu Pb Fe Ni Zn Mn Hg O&G Total Cr Compliance
S.No Name of the location District GPS Coordinates
collection Premises GW water below (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (µg/l) (mg/l) (mg/l) Status
(Y/N) ground level
Drinking Water Specifications as per IS:10500-2012 (Acceptable Limits) in mg/l 200 1 0.003 0.05 0.01 0.3 0.02 5 0.1 0.001 - 0.05
Chemo Pulp Tissues Pvt. Ltd., A-4, Set 22, 28,41,51 N
132 Ghaziabad 08-03-2018 Yes Bore Well 36 m 28 0.5 <0.002 <0.003 - - <0.003 0.12 - <1 - - Complying
Meerut Road Ind. Area Gzb. 27,26,43E
Parle Agro P Ltd. A-7, Sector-22 Meerut Road, 34 0.5 - - 0.02 - 1.01 - Non
133 Ghaziabad 09-03-2018 Yes Bore Well - 50 m <0.002 <0.013 <0.002
Ind. Area, Gzb. Complying
E.C.E. Ltd., A-20, Meerut Road Ind. Area Gzb. 49 0.6 - 0.05 0.07 - 0.07 Non
134 Ghaziabad 13-03-2018 Yes Bore Well - 50 m <0.002 <0.013 <0.003 <1 2
Complying
Near boundry well of M/s ML Batra 28.686521, 23 0.6 0.04 - 0.1 - 0.41 - 1.3 - Non
135 Ghaziabad 05-03-2018 No Hand Pump - <0.003 <0.002
enterprisis 77.438617 Complying
Marshal Cycles, B-17/18, Meerut Road 28.689877, 24 0.8 - 0.07 - - 2.16 - Non
136 Ghaziabad 05-03-2018 Yes Bore Well 60 m <0.002 <0.003 <0.002 <0.002
Industrial Area Gzb. 77.441113 Complying
North Land Cycle Co. Ltd., D-21, meerut Road 28.685197, 17 0.4 - - 0.01 - 1.48 - 0.02 Non
137 Ghaziabad 07-03-2018 Yes Bore Well 50 m <0.002 <0.013 <0.003
Industrial Area Ghaziabad 77.438298 Complying
Industrial area hand pump meerut road Non
138 Ghaziabad 09-03-2018 No Handpump - - 27 0.5 <0.002 <0.003 <0.013 0.69 <0.003 0.04 - <1 2 0.2
ghaziabad Complying
Sukrati Viddut Udyog Pvt.Ltd., D-39, Meerut Non
139 Ghaziabad 05-03-2018 Yes Borewell - - 36 0.4 0.03 0.15 0.09 0.04 <0.003 0.05 - <1 2 <0.002
Road Gzb. Complying
140 Non Stop Colour Industry premises Ghaziabad 06-04-2018 Yes Borewell - - 14 0.1 <0.002 <0.003 <0.013 0.01 <0.003 0.13 - <1 2 <0.002 Complying
22.684 N, Non
141 DPS gate Railway crossing Ghaziabad 08-03-2018 No Handpump 66 m 15 0.3 <0.002 <0.003 <0.013 21.81 <0.003 2.21 0.1 <1 2 0.02
77.434 E Complying
28.686512 N, Non
142 Karhoda village Ghaziabad 07-03-2018 No Handpump 66 m 15 1.8 <0.002 <0.003 <0.013 0.48 <0.003 0.22 <0.002 1.12 2 <0.002
77.387415 E Complying
28.637907 N,
143 Makka Masjid, Vijay nagar Ghaziabad 08-03-2018 No Submersible 50 m 34 0.6 <0.002 <0.003 <0.013 0.05 <0.003 <0.002 0.04 <1 2 <0.002 Complying
77.437488 E
28.63 N, Non
144 Doondaheda village, SS of GT road, Gzb Ghaziabad 06-03-2018 No Hand Pump 40 m 64 0.6 <0.002 <0.003 <0.013 2.14 <0.003 1.04 - <1 - <0.002
77.44 E Complying
Sain Vihar, near Sarthak public school, NH-24, Non
145 Ghaziabad 05-03-2018 No Hand Pump - 40 m 26 0.8 <0.002 <0.003 <0.013 0.73 <0.003 0.06 - <1 - -
Ghaziabad Complying
28.65741 N, Non
146 Slum Area Kavi Nagar B.S. Road Ghaziabad Ghaziabad 07-03-2018 No Hand Pump - 25 0.5 <0.002 <0.003 <0.013 2.19 <0.003 0.06 - <1 - 0.26
77.46966 E Complying
28.664233 N, Non
147 Shastri Nagar Ghaziabad Ghaziabad 07-03-2018 No Hand Pump - 21 0.4 <0.002 <0.003 <0.013 2.57 <0.003 1.06 - <1 - 0.03
77.458378 E Complying
04-04-2018 Non
148 Durgawati Loni, Ghaziabad Ghaziabad No Hand Pump - - 51 0.5 <0.002 <0.003 <0.013 0.51 <0.003 0.22 0.11 <1 - <0.002
Complying
Handpump near Edgah, Ansal, Loni, 04-04-2018 Non
149 Ghaziabad No Hand Pump - - 88 0.6 <0.002 <0.003 <0.013 1.13 <0.003 <0.002 0.08 <1 - <0.002
Ghaziabad Complying
28.78906 N , Non
150 Handpump Near Agrola Village Ghaziabad 08-03-2018 No Hand Pump - 103 0.3 <0.002 <0.003 1.74 4.66 <0.003 0.19 - 1.76 2 <0.002
77.286497 E Complying
28.720358 N, Non
151 Agrola Village, Near Balaji Temple Ghaziabad 09-03-2018 No Hand Pump - 139 0.5 <0.002 0.003 <0.013 3.94 <0.003 0.03 - 1.26 2 <0.002
77.287163 E Complying
Hand Pump, Near to Hanuman mandir, 28.7894 N, Non
152 Ghaziabad 06-03-2018 No Hand Pump 24 m 109 0.4 <0.002 <0.003 <0.013 10.69 <0.003 0.37 - 1.66 - -
Village-Agraula , Tronica City, Loni 77.2868 E Complying
Hand pump near to mohd. Yameen, Om Sai
28.789 N Non
153 City, Vill Agraula, Tronica city, Loni Ghaziabad 06-03-2018 No Hand Pump 36 m 47 0.5 <0.002 <0.003 <0.013 0.43 <0.003 0.12 - 1.12 2 -
77.284 E Complying
Quadri Processors, I-8, See D- 1(P3),.Apparel
154 Park, Tronica City, Ghaziabad 09-03-2018 Yes Bore well - 40 m 22 0.5 <0.002 <0.003 <0.013 0.002 <0.003 0.3 - <1 - - Complying
53
Inside Depth of
Date of sample Industry Source of Ground Sulphate Fluoride Cd Cu Pb Fe Ni Zn Mn Hg O&G Total Cr Compliance
S.No Name of the location District GPS Coordinates
collection Premises GW water below (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (µg/l) (mg/l) (mg/l) Status
(Y/N) ground level
Drinking Water Specifications as per IS:10500-2012 (Acceptable Limits) in mg/l 200 1 0.003 0.05 0.01 0.3 0.02 5 0.1 0.001 - 0.05
Hand pump, village pakhi sadakpur, 1 km, Non
155 Ghaziabad 07-03-2018 No Hand Pump - 43 m 21 0.6 <0.002 <0.003 <0.013 0.42 <0.003 0.24 - - 2 <0.002
Tronica city Complying
Near Adunik Dyeing formally known as Puran
156 Munjal, H-12. Sector D-1(P), Aparels Park, Ghaziabad 06-03-2018 No Bore well - 40 m 48 0.6 <0.002 <0.003 <0.013 0.01 <0.003 <0.002 - <1 2 <0.002 Complying
Tronica City, Loni,Ghazlabad
29° 47' 17.6"N Non
157 Village Agraula Tronika City Loni Ghaziabad Ghaziabad 06-03-2018 No Handpump 67 m 41 0.5 <0.002 <0.003 <0.013 0.01 <0.003 <0.002 - 1.52 - -
77° 17' 41.2"E Complying
28.763003 N Non
158 Road Side Hand Pump Near Tronica City Ghaziabad 07-03-2018 No Borwell 26 m 65 0.2 0.03 <0.003 0.03 - <0.003 0.12 - 1.52 2 -
77.283391 E Complying
M/s Krish Garments (Sanjeev Kumar), G-109,
28.78497 N
159 Sec D-1 (P3), Apparel Park, Tronica City Loni Ghaziabad 09-03-2018 Yes Handpump 20 m 75 0.1 <0.002 <0.003 <0.013 - <0.003 0.11 - <1 2 <0.002 Complying
77.29253 E
Ghaziabad
Siddhi Vinyak Tex, H-11, Apparel Park, Sector
160 Ghaziabad 06-03-2018 Yes Borwell - - 194 0.4 <0.002 <0.003 <0.013 <0.002 <0.003 <0.002 - <1 2 - Complying
D-1(P3), Tronica City, Loni, Ghaziabad.
161 Agrola Village Ghaziabad 06-03-2018 No Hand Pump - - <0.002 <0.003 <0.013 0.02 <0.003 <0.002 - - 2 - Complying
Tronica City, Agraula, Near Chainpal Market, 28.7883 N,
162 Ghaziabad 09-04-2018 No Hand Pump 35 m 60 0.7 <0.002 <0.003 <0.013 - <0.003 0.24 - <1 2 - Complying
Gzb 77.28848 E
28.7937 N,
163 Village Alipur, Mandola 1, Gzb Ghaziabad 09-04-2018 No Hand Pump 35 m 108 0.5 <0.002 <0.003 <0.013 - <0.003 0.04 - <1 2 - Complying
77.27715 E
28.79442 N,
164 Village Alipur, Mandola 2, Gzb Ghaziabad 09-04-2018 No Hand Pump 35 m 101 0.4 <0.002 <0.003 <0.013 - <0.003 0.44 - <1 2 - Complying
77.27719 E
28.686 N,
165 S- Block, Industrial Area Loni, Gzb Ghaziabad 12-04-2018 No Bore Well 30 m 111 0.7 <0.002 <0.003 <0.013 - <0.003 0.03 - <1 2 - Complying
77.37726 E
28.676 N, Non
166 Village Bhoorgarhi, Dasna, Gzb Ghaziabad 26-04-2018 No Hand Pump 40 m 136 1.8 <0.002 0.03 <0.013 0.14 <0.003 <0.002 0.19 <1 2 0.03
77.37726 E Complying
167 Agraula Village, Loni Ghaziabad Ghaziabad 08-03-2018 No Hand Pump - 60 m 119 0.3 - - - - - - - - 2 - Complying
Tusar Garments, J-3, Apparel Park, Sector D-
168 Ghaziabad 08-03-2018 Yes Bore Well - - 60 0.5 - - - - - - - - 2 - Complying
1(P3), Tronica City, Loni.
54
Annexure-X
Water Quality Monitoring Results of River Sheela, Hindon, Krishni, Kali (W), River Yamuna & Drains
collected during March- April, 2018
S. Analysis results
No. Total Fecal Total Cd Cr Cu Fe Mn Ni Pb Zn
River/ Date of Fecal E. coli
As Sample location NH3- Coliform Coliform Enterococcus Plate
Drain sampling pH Cond TDS COD BOD Streptococci MPN/
per N MPN/100 MPN/100 MPN/100 ml Count (mg/L) (mg/L) (mg/L) (mg/L) (mg/L) (mg/L) (mg/L) (mg/L)
Map MPN/100 ml 100 ml
ml ml CFU/ml
2
1 Sheela B/c of Kali (W) River 08.03.2018 8.2 690 444 38 4 2 13 x 10 490 920 920 - - BDL BDL BDL 0.89 0.23 BDL 0.04 0.02
2 Kali (W) A/c of Sheela River 08.03.2018 8 606 374 34 3 3 350 240 1600 1600 - - BDL BDL BDL 0.58 0.24 BDL BDL BDL
Kali (W) 5 5 5 5
3 B/c of River Hindon 08.03.2018 7.9 1616 1244 558 311 18.2 14 x 10 11 x 10 28 x 10 28 x 10 - - BDL 0.05 0.03 2.9 0.31 BDL 0.05 0.58
River
4 3 3 3
4 Hindon River Hindon at Budana 08.03.2018 7.3 1242 726 176 69 23 54 x 10 47 x 10 13 x 10 13 x 10 - - BDL BDL BDL 1.11 0.28 BDL BDL 0.02
A/c of River Kali & 4 3 3 3
5 Hindon 08.03.2018 7.5 1380 1024 410 238 13.4 23 x 10 45 x 10 33 x 10 33 x 10 - - BDL BDL BDL 2.43 0.46 BDL BDL 0.96
B/c of River Krishni
River Krishni B/c of
6 Krishni River Hindon at 08.03.2018 7.8 1276 800 254 34 32 92 x 103 54 x 103 310 310 - - BDL BDL BDL 0.7 0.2 BDL BDL 0.03
Barnawa
River Hindon at
7 Hindon 08.03.2018 7.8 1300 944 260 55 22 40 x 103 26 x 103 25 x 102 25 x 102 - - BDL BDL BDL 1.37 0.22 BDL BDL 0.48
Pura Mahadev
River Hindon U/s of
8 Hindon 11.04.2018 7.2 351 218 41 9 2.5 35 x 103 33 x 102 - - - - BDL BDL BDL 1.1 - 0.01 BDL 0.24
Khareda Drain
Karheda Drain B/c of
Drain 11.04.2018 7.53 - 1768 350 103 - - - - - - - BDL 0.29 0.06 8.86 - 0.11 0.14 2.07
9 River Hindon
Indirapuram Drain
10 Drain 11.04.2018 7.22 - 760 546 179 - - - - - - - BDL 0.02 BDL 3.38 - 0.01 0.02 0.38
B/c of River Hindon
Hindon Vihar Drain B
11 Drain 11.04.2018 7.3 - 1104 567 148 - - - - - - - BDL 0.35 0.18 16.22 - 0.06 0.17 0.67
/c of River Hindon
Pratap Vihar Drain
Drain 11.04.2018 7.08 - 2780 557 149 - - - - - - - 0.01 0.02 0.02 16.12 - 0.01 0.49 0.35
12 B/c of River Hindon
khaila Bhatta Drain
Drain 11.04.2018 7.48 - 1088 393 169 - - - - - - - BDL 0.09 BDL 5.09 - 0.04 BDL 0.22
13 B/c of River Hindon
Kot Escape Drain
14 Drain 13.04.2018 7.4 442 264 26 7 2.8 - - - - - BDL 0.05 BDL 2.32 - BDL BDL BDL
B/c of River Hindon
River Hindon
15 Hindon 13.04.2018 7.4 658 360 63 15 5.9 92 x 105 92 x 105 24 x 104 24 x 104 92 x 105 15 x 105 BDL 0.21 BDL 7.05 - 0.01 BDL 0.04
B/c of River Yamuna
River Yamuna 6 5 4 4 4 4
16 Yamuna 13.04.2018 7.5 669 374 65 14 6.6 16 x 10 14 x 10 13 x 10 13 x 10 33 x 10 75 x 10 BDL 0.20 BDL 4.21 - BDL BDL BDL
A/c of River Hindon
55
Annexure-X (a)
Water Quality Monitoring Results of River Hindon, Krishni, Kali (W), Sheela, River Yamuna & Drains – For pesticides
(Corrected)
56
Annexure-XI
Industry-wise Water Consumption, Waste Water Generation and
Final Mode of Disposal of Generated Industrial Effluent
Final mode of
Total Water Waste Water disposal of
Source of
Sl. No Name & Address of Industry Consumption in Generation generated
water supply
KLD in KLD Industrial
effluent
Adarsh Thermopack Industries (P)
Bore well 25 20 Drain
1 Ltd, E-106, Site B, Surajpur, Greater Noida
Aricab Fab (P) Ltd,
Closed Closed Closed Closed
2 C-4, Site-4, Surajpur, Greater Noida
Chaudhary Skin Trading Company,
Bore well 27 14 Drain
3 D-34, Site-B, Surajpur, Greater Noida
Colour & Style (P) Ltd,
Bore well 55 46 Drain
4 A-1/2, 8/9, Site-B, Surajpur, Greater Noida
Continental Milkose (India) Ltd,
Bore well 1.5 50 Reuse
5 Habibpur, Kulesra, Greater Noida
Honda Cars India Ltd,
Plot No A-1, Sector40/41, Surajpur, Bore well 2920 955 Reuse
6 Kasna Road, Greater Noida, U.P.
7 Hotz Industies Udyog Vihar, Greater Noida Closed Closed Closed Closed
M/S LG Electronics,
Plot nN 51, Udyog Vihar , Bore well 750 750 Reuse
8 Surajpur, Gr.Noida, UP
M.K.leather Trading Company,
Bore well 2.5 2.5 Drain
9 0-33, Site B, Surajpur, Greater Noida
Shree Jagdamba Knits (P) Ltd,
Bore well 400 300 Drain
10 P.No.-95,105, Site-B, Surajpur Indl.Area,G.Noida
M/S Gabriele Lucano CNH Industrial India Pvt
Ltd formerly known as M/s New Holland Fiat
Bore well 1000 1000 Reuse
(India) Pvt. LTd., Plot No 3 Udyog kendra,
11 Ecotech-III, G.Noida
Sky Lark Dyeing (P) PVT LTd,
Bore well 200 200 Drain
12 Plot No.- B-2/14. Site-B, Surajpur, G.Noida
M/S Yamaha Motor India (P) Ltd.,
A3 Indl.Area, Noida-Dadri Rd, Surajpur, Bore well 800 800 Drain
13 G.B. Nagar
M/S Suchi Paper Mills Ltd,
589/2, Bisrakh Road, Vill. Chapraulla, Bore well 1000 500 Drain
14 G.B. Nagar
M/S Kawatra Papers (P) Ltd.,
khasra No. 606, Village,Dhoom Manikpur, Tube well 800 500 Drain
15 G.T. Road, Dadri, Dist. GB Nagar, UP
M/s Aar Bee Exports,
Closed Closed Closed Closed
16 Plot No-155, Udyog Kendra, Greater Noida
M/s Amber Enterprises Ltd,
Tube well 30 40 Reuse
17 Plot No-C-3,UPSIDC, Site-4, Ksana G.Noida
M/s Autotech Steel Engineering (P) Ltd,
Bore well 7 3 Reuse
18 PIot.No. 2B/3, Ecotech-I, Extn-I, Kasna, G.Noida
Bajaj Carpet Industries Ltd,
Bore well 47 30 Drain
19 Suthyana Noida Dadr Highway G.B. Nagar
M/S Capital dyeing works,
Bore well 30 21 Drain
20 Plot No C-6, site C6, Surajpur, UPSIDC, G.Noida
C & S Electric Ltd,
Plot No B-I, Site 4 Indl.Area, Kasna Road, Tube well 12.5 5 Drain
21 G.Noida
Expert Metaltech Pvt Ltd,
Bore well 0.5 0.5 Drain
22 Factory 192, Udyog kendraI Gr.Noida (U.P.)
G.T.Cargo fittings India Pvt. Ltd.
Plot no-92, Udhog kendra, Bore well 8.5 6 Drain
23 Ecotech III, G.Noida
Ganga Polyester Ltd. .
Bore well 7 6 Drain
24 H-37/38 Site C, Surajpur Textiles
M/s Garg Tube Co. Ltd.
Tube well 12 10 Drain
25 Vill-Chaproulla, G.T. Road,G. Noida
Goodluck Engineering,
Bore well 75 Not Available Not available
26 ViLL -Dhoom, Manikpur, G.T. Road, G. Noida
M/S Hero Motors Ltd. (Punch Division),
Bore well 150 90 Reuse
27 Vill-Achheja, G.T. Road, G. Noida
M/s Honda Siel Power Product Ltd,
Bore well 750 720 Reuse
28 Plot No -5, Sec41, Ecotech-1, G Noida
M/s Indo Pump
Bore well 12 8.8 Drain
29 Plot no F-29-30, Site B, G. Noida
M/s Indus tubes Ltd,
Bore well 12 6 Drain
30 Vill-Chaproulla, G.T. Road, G. Noida
M/s Jayanita Export (P) Ltd.
Bore well 4 3.5 Drain
31 Plot No. A-1, EPIP, Kasna, G. Noida
M/s J.M.V.L.P.S. Ltd., (Ex Name J.M.V. Earthing
Equipment pvt. Ltd) Bore well 1.46 1.25 Drain
32 Plot No- J-12, Site-C, UPSIDC, Gr.Noida
M/s JBM Autotech,
Bore well 1.7 1.25 Drain
33 Plot No. J-5, SITE -C , Gr.Noida
M/s Material Movell India (P) Ltd,
PIot.No.G-86/1, Site-5, UPSIDC,Gr.Noida Bore well 1.33 1.16 Drain
34
57
Final mode of
Total Water Waste Water disposal of
Source of
Sl. No Name & Address of Industry Consumption in Generation generated
water supply
KLD in KLD Industrial
effluent
M/s Mohak Carpet
Closed Closed Closed Closed
35 Plot No. 8, Mihila Udyami Park-II, G.Noida
Nippon Tube Ltd,
Bore well 8.3 7.5 Reuse
36 Bisrakh Road, Vill- Chapraulla, Gr.Noida.
M/s R.S. Infrastructure Pvt. Ltd.
Bore well 10 0.6 Reuse
37 Plot No. 12/1, Site -C, Surajpur, Gr.Noida
M/s Rahul lonTech Pvt. LTd,
Plot No. 143, Plot No. 143, Bore well 5.5 5.5 Drain
38 Udyog Kendra, Gr.Noida
M/s Sunshine Auto Industries
Closed Closed Closed Closed
39 Plot No. F-24, Site-B SURAJPUR, Gr.Noida
M/s Surya Processor Pvt. LTd ,
Bore well 492 435 Drain
40 BISRAKH ROAD, Vill-CHHAPRAULA, Gr.Noida
M/S V.N.M. Components,
Closed Closed Closed Closed
41 Plot No-116, Site B, Surajpur, Greater noida
M/s Bir Horizons Pvt. Ltd. ,
Bore well 32 2 Drain
42 Plot No. F-79, SITE-B, Surajpur, Gr.Noida
Vimal dyeing
Bore well 4 3 Drain
43 Hite C, H-41, surajpur industrial area
M/s Vikas Wire Industries,
Bore well 0.25 0.22 Drain
44 Plot No 5-37, Site C, Gr. Noida
S.P.Metaltech India Pvt LTD ,
Bore well 0.25 0.22 Drain
45 G-82&81, Site B, Indl. Area, Surajpur, Gr.Noida
M/s Metaltech Design (P) ltd,
Bore well 0.5 0.3 Drain
46 Plot No 7, Udyog Kendra, Gr.Noida
India Dyeing and Textiles,
Bore well 8.7 8.2 Drain
47 F 75, Site B, Surajpur, Gr.Noida, G.B.Nagar
Spack Automotive pvt Ltd.
Bore well 46 7.6 Drain
48 Kasna Road, Surajpur, Greater Noida
M/S Neuman Components Pvt. Limited
Bore well 8.7 8 Drain
49 Plot no 35,Sec-31, Kasna, G. Noida
M/S Rasandik Engg. India Ltd.,
Bore well 1700 1300 Drain
50 Plot no A-1/2, Surajpur , Industrial Area, G. Noida
M/S Asian Paints Ltd.,
Plot No. A-1, UPSIDC, Indl. Area, Bore well 330 160 Reuse
51 Site 5, G. Noida,
M/s. Surya Fresh Food Ltd.,
Bore well 25 Not Available Drain
52 Plot No. 14, Dadri Road, G.Noida, GB Nagar
M/S Graziano Trasmissioni India Pvt.
Bore well 200 107 Reuse
53 Ltd., PLOT NO-14, Udyog Kendra, Gr.Noida
M/S KRBL Ltd.,
Bore well 265 270 Reuse
54 Village- Achchheja,G.T. Road , Dadri, Gr.Noida
M/s Bajaj Hindustan Sugars Ltd,
Tube well 2094 590 Reuse
55 Sugar Unit,Kinauni, Meerut
M/s Bajaj Hindustan Sugars Ltd, Distillary
Tube well 1434 1389 Reuse
56 Unit,Kinauni, Meerut
M/s Sardhana Papers pvt Ltd,
Bore well 515 294 Drain
57 Opp. Power sub station,Meerut Road, Sardhana
M/s Ramala Sahkari Chini Mills Ltd,
Tube well 113 83 Reuse
58 Ramala, Bagpat
M/s Titwai Sugar Complex,
Bore well 1035 900 Lagoon
59 Indian Potash Limited unit,Titwai, Muzaffarnagar
M/s Bajaj Hindustan Ltd.
Budhana, Tube well 712 667 Lagoon
60 Muzaffarnagar
M/s D.S.M. Sugar
Bore well 157 57 Reuse
61 Mansurpur, Meerut Road.
M/s Uttam Sugar Mills,
Bore well 454 227 Reuse
62 Khaikheri,Muzaffarnagar.
M/s Triveni Engg. Industries Ltd.
Bore well 164 188 Reuse
63 Khatauli, Muzaffarnagar.
M/s Triveni Engg. Industries Ltd.(Alco)
Bore well 1430 1040 Reuse
64 Bilaspur, Jolly Road, Muzaffarnagar.
M/s Sir Shadi Lal Distillery & Chemical Works,
Tube well 650 710 Reuse
65 Mansoorpur
M/s I.P.L. Sugar Unit
Bore well 185 134 Reuse
66 Rohana Kalan, Muzaffarnagar.
M/S Garg Duplex,
Bore well 1013 563 Drain
67 Bhopa road, Muzaffarnagar, U.P
M/s Silvertone Paper Ltd. (unit I)
Bore well 930 900 Drain
68 Bhopa Road, Muzaffarnagar
M/s Shalimar Paper (p) Ltd.,
Closed Closed Closed Closed
69 8th KM stone Jansath Road,Muzafarnagar
M/S Bindalas Ltd, (Unit-1)
Bore well 500 300 Drain
70 Bhopa Road, Muzaffarnagar
M/S Bindalas Ltd, (Unit-2)
Bore well 1150 950 Drain
71 Bhopa road, Muzaffarnagar
M/S Shakumbari Pulp & Paper
Bore well 525 250 Drain
72 Bhopa Road
M/s. N.S. Papers Ltd. (Unit-1),
Bore well 325 250 Drain
73 Jansath Road, Muzaffar Nagar
M/s. N.S. Papers Ltd. (Unit-3),
Bore well 1000 750 Drain
74 Jansath Road, Muzaffar Nagar
M/S Mahalaxmi Craft & Tissues
Bhopa Road, 9th Km, Bore well 450 225 Drain
75 Jansath Road
58
Final mode of
Total Water Waste Water disposal of
Source of
Sl. No Name & Address of Industry Consumption in Generation generated
water supply
KLD in KLD Industrial
effluent
M/S Aggarwal Duplex & Board Mills Ltd.
Bore well 1600 845 Drain
76 Bhopa Road
M/S Tirupati Balaji Fibers Ltd.
Bore well 335 235 Drain
77 Bhopa Road
M/S Meenu Papers (P) Ltd.,
Bore well 400 310 Drain
78 9.5 Km, Bhopa Road
M/S Tehri Pulp & Papers Ltd. (Unit-I), 9th Km
Bore well 2875 2000 Drain
79 Stone, Bhopa Road
M/S Tehri Pulp & Papers Ltd. (Unit 2),
Bore well 900 660 Drain
80 9th Km Stone, Bhopa Road
M/S Suyash Craft & Papers Ltd
Bore well 522 300 Drain
81 Village- Velhana, Meerut Roadf, Muzaffarnagar
M/S Shri Bhageshwari Paper Mills (P) Ltd.,
9 th Km Stone (Unit-1), Bhopa Road, Bore well 1800 1400 Drain
82 Muzaffarnagar
M/S Shri Bhageshwari Paper Mills (P) Ltd.,
9 th Km Stone (Unit-2), Bhopa Road, Bore well 2134 1710 Drain
83 Muzaffarnagar
M/s Sidhbali Papers mills Ltd,),
Bore well 913 525 Drain
84 45-B, New Mandi, Muzaffarnagar
M/s Siddheshwari Ind. Pvt. Ltd.,
Bore well 730 365 Drain
85 Jansath Road,
M/s K.K. Duplex & Paper Mill Pvt.
Bore well 165 70 Drain
86 Ltd., Jansath Road, Muzaffarnagar
M/s Silver Tone Pulp & Paper,
Bore well 645 966 Drain
87 9th Km Stone, Bhopa Road, Muzaffarnagar.
M/S Bindal Papers Ltd.
Bore well 9429 5475 Reuse
88 Bhopa Road, Muzaffarnagar
M/s. Arihant Pulp & Papers Ltd.,
Closed Closed Closed Closed
89 Jansath Road, Muzaffar Nagar.
M/s Disha Industries ltd.,
Bore well 800 585 Drain
90 9th Km, Jolly Road, Vill- Sikhrera, Muzaffarnagar
M/s. Galaxy Papers Pvt. ltd.,
9.4 Km Jolly Road, Vill- Bore well 180 0 Reuse
91 Dhandhara,Muzaffarnagar
M/s. Taj Papers Pvt. Ltd., Jolly Road,
Closed Closed Closed Closed
92 Muzaffarnagar
M/s. Shaktl Kraft & Tissues Pvt. Ltd.,
Bore well 500 480 Drain
93 9th Km, Jansath Road,Muzaffarnagar
M/s. Aristo Craft Papers Pvt ltd,
Bore well 285 250 Drain
94 7 Km, Meerut Road, MuzaffarNagar
M/s. Orient Board & Papers Pvt. Ltd.,
Closed Closed Closed Closed
95 Jansath Road, Muzaffarnagar
M/s Magma Industries Ltd.,
C-27 UPSIDC Industrial Area, Bore well Not available Not Available Drain
96 Begrajpur, M.Nagar
M/s. Ravi Organics Ltd.,
Closed Closed Closed Closed
97 Begrajpur, Muzaffarnagar
M/s. Gulshan Polyoles Ltd.,
Bore well 1030 910 Drain
98 Jansath, Road, Muzaffarnagar
M/s. Al-Noor Exports,
Bore well 270 107 Drain
99 Jansath Road, Muzaffarnagar
M/s Parijat Paper Mill, Bhopa Road,
Bore well 780 815 Drain
100 Muzaffarnagar
M/s. H.J. Tannery,9th Km, Jansath Road,
Bore well Not Available Not Available Not Available
101 Muzaffarnagar
M/s Nikita Papers P.Ltd.,
Tube well 400 1600 Reuse
102 C-10, Ind.Estate, Panipat road, Shamli
103 M/s.Maruti Papers Pvt.Ltd., Village Sikka, Shamli Tube well 516 Not Available Reuse
104 M/S Upper Dpab Sugar Mill Shamli Bore well 1080 600 Reuse
M/s Bajaj Hindustan Ltd.
Bore well 1100 1000 Reuse
105 Thanabhawan, Muzaffarnagar
106 Shamli distillery & Chemical works , Shamli Bore well 650 405 Reuse
M/s NTPC Ltd, Upper Ganga
7300 2350 Drain
107 Dadri, Gauthambuddh nagar Canal
M/s Co-operative Co. Ltd.,
Bore well Not available Not Available Not available
108 Tapri, Saharanpur
M/S U.P Coperative Sugar Factories Fedreation
Ltd. Nanawta Distillery Unit , Nanauta , Closed Closed Closed Closed
109 Saharanpur
Bajaj Hindustan Ltd. Distillary Unit
Bore well 760 560 Reuse
110 Gangnoli
The Kisan Sahakari Chini Mill,
Bore well Not available 500 Lagoon
111 Nanouta, sahranpur UP
112 Daya Sugar Gagalheri, Saharanpur, U.P Bore well 3250 500 Lagoon
Triveni Engg. & Industires Ltd.,
Bore well 54.5 1080 Lagoon
113 Deoband, Saharanpur, U.P
Bajaj Hindustan Sugar Ltd.,
Bore well 1150 682 Lagoon
114 Gangoli Saharanpur, U.P
115 Star Paper Mill , Saharanpur Tube well 12000 12000 Drain
116 Plaza Paper P.Ltd. Saharanpur Closed Closed Closed Closed
Rainbow Board Mill, (Unit Kraft Paper)
Closed Closed Closed Closed
117 Saharanpur
118 Swaroop Paper (P) Ltd. Saharanpur Closed Closed Closed Closed
119 Hindon Filter (P) Ltd. Saharanpurr Bore well 354 202 Drain
59
Final mode of
Total Water Waste Water disposal of
Source of
Sl. No Name & Address of Industry Consumption in Generation generated
water supply
KLD in KLD Industrial
effluent
120 Nagar Nigam Pashuvadhshala, Saharanpur Bore well 175 150 Drain
A.L. M. Industries (Slaughter House),
43, Qutab Market, Near Qutab Sher Thana, Bore well 345 480 Reuse
121 Ambala Road, Saharanpur
A.L.M. Industries (Meat Processing Unit) ,
43, Qutab Market, Near Qutab Sher Thana, Bore well 56 100 Reuse
122 Ambala Road, Saharanpur
J.J. Textile, Textile,
Mahipura Road, Near MS College, Bore well 20 19.4 Drain
123 Janta Road, Saharanpur
Durga Textile, Mahipura Road,
Bore well 23 22.4 Drain
124 Near MS College, Janta Road, Saharanpur
Garg Dyeing, 47 Kamdhenu Complexd,
Closed Closed Closed Closed
125 Saharanpur
126 Arora Hoiesery, Janta Road, Saharanpur Bore well 19 15 Drain
Deep Industries
Bore well 21 20.5 Drain
127 Delhi Road, I.E., Delhi Road, Saharanpur
Atul Textile Industried Ltd.,
Bore well 21 20.4 Drain
128 Shakumabari, Behat Road, Saharanpur
M/s Siddhartha Textile,
Bore well 21 20.6 Drain
129 Aziz colony, Chilkana Road, Saharanpur
M/s Saharanpur Wooles Ltd.,
Bore well 25 22 Drain
130 Delhi Raod, Saharanpur
M/s Shalimar Cotton Dyeing,
Bore well 21 21.5 Drain
131 Saharanpur Behat Road, Rasulpur, Saharanpur
132 M/s S.M.C. Foods Ltd. Nnauta, Saharanpur Bore well 150 900 Drain
M/s Pashupati Dairy (P) Ltd.
Village Kumharhera, Dehradun Road, Bore well 0.75 0.5 Drain
133 Saharanpur
Shree Krishna Board Mill
Tube well 10 10 Reuse
134 Dehradun Road, Saharanpur
135 Mahaveer Hand Made Paper & Board Mill Closed Closed Closed Closed
136 Shankar Board Mill Saharanpur Closed Closed Closed Closed
137 M/s Parmal Paper Ltd., Saharanpur Closed Closed Closed Closed
138 Rainbow (P) Ltd. Mills Saharanpur Closed Closed Closed Closed
Saharanpur Paper Board Mill,
Bore well 2 0.5 Reuse
139 Village- Majri, Dehradun Road, Saharanpur
Majri Gramodhyod Sansthan,
Bore well 1 0.3 Reuse
140 Village- Majri, Dehradun Road, Saharanpur
M/s Jagadamba Gramodyog Sansthan Name
changed to M/s Laxmi Associates, Chhagpura, Bore well 1 0.15 Reuse
141 Deharadun Road, Sharanpur.
M/s Jayna Gramodyaog Sansthan,
Gagalheri Name changed to M/s Ekta Bore well 1 0.15 Reuse
142 Gramodyog Sansthan, Gagalheri.
M/s Tiwaya File Board Mill,
Bore well 0.8 0.075 Drain
143 Nawada Road, Saharanpur
144 M/s Star Gramodyaog Sansthan, Manakmau, Closed Closed Closed Closed
Janhit Gramodhyog Sansthan
Closed Closed Closed Closed
145 Dehradun Road, Saharanpur
M/s Sufi Pulp & Paper Gramodhyog Sansthan,
Closed Closed Closed Closed
146 Gagalheri, Saharanpur
M/s Balaji Wire Pvt. Ltd.,
139·A, Anand Industrial Estate Mohan Nagar, Bore well 40 6 Drain
147 Gzb.
M/s Bansal Wire high Corbon Pvt.ltd.,
Bore well 36 16 Drain
148 120-126, Anand Ind. Estate Mohan Nagar Gzb.
M/s Jai Durge Metalizing,
Closed Closed Closed Closed
149 67, Anand Ind. Estate Mohan Nagar Gzb.
Sarasati Bangle Udyog,
Closed Closed Closed Closed
150 29, Anand Industrial Estate Mohan Nagar,Gzb.
Mohan Meakins Ltd.,
Mohan Nagar, Bore well 439 257 Reuse
151 Ghaziabad
Yadav Industries, Not exists at
Not exists at the Not exists at the Not exists at the
7, Anand Ind.Estate , Mohan Nagar Gzb the given
given Address given Address given Address
152 Address
A.B.Cycle Parts Pvt. Ltd.,
Bore well 0.6 0.3 Drain
153 S-24, South Side of G. T. Road, Gzb.
A.C.E. Hardware Pvt. Ltd.,
Not applicable Not applicable Not applicable Not Aplicable
154 E-21 & 22, Kavinagar Ind. Area Gzb.
A.S.T. Pipes,
Closed Closed Closed Closed
155 B-33, BS Road Ind. Area, Gzb.
156 Amit Textiles, 5-32, SS of GT Road Closed Closed Closed Closed
157 Amko Export, A-1, B.S. Road Ind.Area, Gzb. Bore well 270 200 Drain
158 Amrit Foods, Amrit Nagar, G.T. Road East Gzb. Bore well 290 140 Drain
Balaji Engineering Works, 351, Pandav Nagar,
Bore well 0.18 0.14 Reuse
159 Gzb.
Balaji Enterprises,
Bore well Not available Not Available Reuse
160 B-22/1/15, B.S.Road Ind. Area Gzb.
Continental Carbon India ltd.,
Tube well 450 900 Reuse
161 A·14, SS of G.T. Road Gzb.
Elin Electonics Ltd.,
Bore well Not available Not Available Drain
162 C-142-144, BS Road, Industrial Area, Gzb.
163 Indian Textiles Co., E-49, B.S. Road, Gzb. Bore well 60 40 Drain
60
Final mode of
Total Water Waste Water disposal of
Source of
Sl. No Name & Address of Industry Consumption in Generation generated
water supply
KLD in KLD Industrial
effluent
J.D.M. Enterprises, Purchased
0.5 Not Available Drain
164 C-223/1, BS Road Ind. Area Gzb. water
Karam Chandra Chains Ltd.,
Tube well Not available Not Available Drain
165 C-229, BS Road Ind.Area Gzb.
Karam Chandra Rubber Pvt. Ltd.,
Bore well 8 6 Reuse
166 C- 230 B5 Road Ind. Area Gzb.
Kashyap Organics Pvt. Ltd.,
Closed Closed Closed Closed
167 C-172, B.S. Road Ind. Area Gzb.
lion Cycle & Rikshaw Industries,
Not available Not available Not Available Not available
168 E·l0, B.S. Road Ind. Area Gzb.
Malik Nidles & Allied Products,
Bore well 0.5 0.4 Drain
169 C-108, BS Road Ind. Area Gzb.
Manav Braveries Pvt. Ltd.,
Closed Closed Closed Closed
170 C-128, BS Road Ind.area Gzb.
Nip Man Fastners India Pvt. ltd.,
Closed Closed Closed Closed
171 C- 197, BS Road Ind. area Gzb.
Northern India Cyco Parts,
Bore well 4 6 Drain
172 E-2, SS of GT Road Gzb.
Progressive Tools & Component Pvt.Ltd.
Bore well 14.4 14 Drain
173 C-222, B.S. Road Ind. Area , Gzb
S.S.Enterprises,
Not available 0.5 0.2 Reuse
174 363, Pandav Nagar Mahrauli Gzb.
M/s Shakshi Metals Works,
D-1A, Kavi Nagar Industrial Area, Bore well 1 0.07 Drain
175 Sec-7, Ghaziabad
M/S Shanti Nath Manufactures ,,
Bore well 0.3 0.25 Drain
176 A-2/4, E-block, Kavi Nagar Indl.Area, Ghaziabad
M/S Sara Exports Ltd,
Plot No 35/1, 36 south slide,
Bore well 42 41.5 Drain
G.T. Road,
177 Industrial area, Ghaziabad
M/s Shivam Engineering and fabrication,
A -282, south side, Bore well Not available 0.14 Drain
178 G.T. Road Industrial area, Ghaziabad
M/s Shri Guru Kripa Industries,
Purchased
E-25, south side, Industrial area, 2500 520 Drain
water
179 G.T. Road, Ghaziabad, U.P.
M/s Suruchi Dyeing Udyog Pvt Ltd
Bore well 3.47 1.74 Reuse
180 37, South side Industrial area, NH 24, Ghaziabad
M/s Tarun International
Bore well 4 Not Available Drain
181 C-15, SS of GT road, Ghaziabad
M/s Vimal Organics Pvt Ltd,
Closed Closed Closed Closed
182 D-35BS Road, Industrial area, Ghaziabad
M/s Al Nafees Frozen Foods Export,
Bore well 600 Not Available Drain
183 Hapur Rd. Dasna Ghaziabad
M/s AI-Naseer Export Pvt. Ltd.,
Khasara no 2761 & 2762 Bore well 440 200 Drain
184 ViII- Bhoorgarhi Dasna , Ghaziabad
M/s Eagle Continental Foods Pvt ltd,
Bore well 300 300 Not available
185 Dasna Ghaziabad
M/s Exclusive leathers,
Khasara No, 2751, Bore well Not available Not Available Drain
186 Bhoorgarhi Dasna , Ghaziabad
Futuro Component Pvt. Ltd.,
Bore well 22 Not Available Drain
187 koshilya road Hindon River, Dasna, Ghaziabad
M/s International agro Foods (Integrated
slaughter House) Plot No. 2764 - 2766, Bore well 240 220 Reuse
188 Bhurgardi, Dasna, Distt. Ghaziabad U.P.
M/s Karan Frozen Foods,
Bore well Not available Not Available Drain
189 Plot No. 2770, 2772, Burgadi, Dasna, Ghaziabad
M.D.Frogen Foods Export,
Bore well Not available Not Available Not available
190 Vill- Bhoorearhi Dasna Ghaziabad.
M/s Shree Ganga Paper Mills Pvt. Ltd.
Bhurgadi, Dasna, Hapur Road, Tube well 175 0 Reuse
191 Ghaziabad, UP
M/s Triyash Enterprises,
Khasra no-2751, Village-Bhoorgarhi Dosna, Bore well 70 50 Drain
192 Ghaziabad
M/s U.P. Board & Container Pvt. Ltd.,
Closed Closed Closed Closed
193 Dasna Ghaziabad
M/s Devtara Industries,
Bore well 1004 728 Drain
194 Meerut Road Duhai Muradnaaar Gzb.
M/s A & A,
S-50, Loni Road Ind. Area Tube well 22 18 Drain
195 Site II Mohan Nagar Gzb.
M/s A.N.Fabric (Ex. Name B.K. Enterprises),
Tube well 10 10 Drain
196 5/6, site-2, Loni Road, Gzb.
M/s Ajay Washing,
S-62, Loni Road Ind. Area, Mohan Nagar Gzb.
Closed Closed Closed Closed
Presently Wall Putty Manufacturing Unit namely
197 M/s Wall Shine is in operation
M/s Alps Industries Ltd.,
Tube well 10 8 Not available
198 Unit-3, A-2, Loni Road Mohan Nagar Gzb.
M/s Ambica Steels Ltd.,
Plot no. 32 site-2 Loni road Industrail Area Bore well Not available Not available Reuse
199 Mohan Nagar, Ghaziabad, U.P.
61
Final mode of
Total Water Waste Water disposal of
Source of
Sl. No Name & Address of Industry Consumption in Generation generated
water supply
KLD in KLD Industrial
effluent
M/s Asha Prints,Ltd.,
A-5/4, 32 Loni road Mohan Nagar, Bore well 0.25 0.225 Drain
200 Ghaziabad, U.P.
M/s Asha Tanu PrintsLtd.,
Bore well 0.5 0.25 Drain
201 A-5/4 Loni road Mohan Nagar, Ghaziabad, U.P.
M/s Bansal Wire Industries Ltd,
Bore well 40 7 Drain
202 B-3, Loni road, Mohan Nagar, Ghaziabad, U.P.
M/s Bansal Wire Industries unit-III Ltd,
B 5-6, Site-2, Loni road Mohan Nagar, Bore well 36 4 Drain
203 Ghaziabad, U.P.
Harig India Ltd.,
Closed Closed Closed Closed
204 GT Road Mohan Nagar Gzb.
M/S Kishan lal & Co.
13-A/14 site 2, Loni road,Mohan Nagar Closed Closed Closed Closed
205 Ghaziabad
206 M/s Laxmi Dyeing Pvt LTd Tube well 40 35 Drain
M/S M.G. Electronics Pvt LTd,
6 loni road, Industrial area, Mohan Nagar, Bore well 53.5 18 Drain
207 Ghaziabad
M/S Dyes ,
S102, Loni road, Indl.Area, Mohan Nagar, Closed Closed Closed Closed
208 Ghaziabad
M/s M.S.D. Dytex Pvt Ltd,
5/2 Loni road, Industrial area, Closed Closed Closed Closed
209 Mohan Nagar Ghaziabad
Mayur prints,
5/8 site -2, loni road Ind Area, Bore well 90 83 Drain
210 Mohan Nagar, Ghaziabad
Mita Haring India Ltd,
Bore well 20 Not Available Drain
211 GT road, Mohan Nagar, Ghaziabad
Micro Gartex Industries,
Bore well 0.15 0.008 Not Aplicable
212 C-2, site II, Loni road, Ghaziabad
Animesh Graphic Engineers, Not exists at
Not exists at the Not exists at the Not exists at the
S-74, Loni Road, the given
given Address given Address given Address
213 site II, Ghaziabad Address
Non Stop Colours,
Bore well 70 60 Drain
214 Plot No-3, Loni Road Site-2, Gzb.
Om Printers,
Closed Closed Closed Closed
215 C-3, Site-2, Loni Road Mohan Nagar Gzb.
M/s Sun Labtek Equipments Pvt. Ltd. Not exists at
Not exists at the Not exists at the Not exists at the
Loni Road Industries Area Ghaziabad the given
given Address given Address given Address
216 Address
S.R.Prints,
Bore well 5 4.5 Drain
217 C-I, Loni road Ind.Area Mohan Near Gzb.
Sahi Exports (Sarla Fabrics Ltd.),
Bore well 11 6 Drain
218 30, Loni Road lnd.Area Mohan Nagar Gzb.
M/s Sai Processing
Bore well 16 15 Drain
219 7/37, site no-2 Loni Road Mohan Nagar Gzb.
M/s Santosh wire industries,
Not exists at
C-6 Loni Rd Ind area, Mohan Ngr, Ghaziabad not Not exists at the Not exists at the Not exists at the
the given
existing at this address instead M/s V.J. metal given Address given Address given Address
Address
220 components pvt Ltd in opeartion
Saroj Creation Pvt. Ltd.,
Bore well Not available Not available Not available
221 C-24, 25 Loni Road Ind Area Gzb.
Shri Balaji Processors,
Not applicable Not applicable Not applicable Not Aplicable
222 S-132, Harsha Compound, Mohan Nagar Gzb.
Sunny Prints,
Bore well 0.25 0.2 Not available
223 5/7, Site-II Industrial Area, Loni Road, GZB.
Yadav Industries,
Bore well 25 6 Not available
224 C-11, Loni Road Ind.Area Gzb.
Agarwal Galvanizing, Unit-2,
Bore well 16 8 Not available
225 A-8/6, Meerut Road Ind. Area Guldar Ghaziabad
Albert David Ltd.,
Bore well 400 100 Drain
226 B-13, Meerut Road industrial Area Ghaziabad.
Chemo Pulp Tissues Pvt. Ltd.,
Bore well 0.7 1.5 Not available
227 A-4, Set 22, Meerut Road Ind. Area Gzb.
Crop Health Product Pvt. Ltd.,
Closed Closed Closed Closed
228 D- 31/1, Meerut Road Ind. Area Gzb.
Deewan Reclame Rubber Ltd.,
Closed Closed Closed Closed
229 A-3, Meerut Road Gzb.
E.C.E. Ltd.,
Bore well 10 7 Drain
230 A-20, Meerut Road Ind. Area Gzb.
Parle Agro P Ltd.
Bore well 866 156 Drain
231 A-7, Sector-22 Meerut Road, Ind. Area, Gzb.
Hamdard (Wakf) Laboratories, (1 & 2)
Bore well 225 20 Drain
232 B-2 &3 Meerut Road Gzb.
International Tobacco Co. Ltd.,
Bore well 18 26 Reuse
233 Meerut Road, Guldhar, Ind. Gzb.
Kathuria Brothers,
Bore well 65 50 Drain
234 A-l2, Site -3, Industrial Area, Meerut Road Gzb.
Kathuria Brothers,( Cycle Section)
Bore well 15 Not available Drain
235 A-12 Meerut Road Industrial Area Gzb.
Marshal Cycles,
Bore well 50 40 Drain
236 B-17/18, Meerut Road Industrial Area Gzb.
Mascot India Tools Ltd.,
Closed Closed Closed Closed
237 A-2, Meerut Road Ind. Area Gzb.
62
Final mode of
Total Water Waste Water disposal of
Source of
Sl. No Name & Address of Industry Consumption in Generation generated
water supply
KLD in KLD Industrial
effluent
North Land Cycle Co. Ltd.,
Bore well Not available Not available Drain
238 D-21, meerut Road Industrial Area Ghaziabad
239 Ramsons Enterprises, D-21 A, Meerut Road Gzb. Bore well Not available Not available Drain
Roxy Investment Pvt.Ltd.,
Closed Closed Closed Closed
240 C-3, meerut Industrial Area Ghaziabad
Samtal Electron Devices Ltd.,
Closed Closed Closed Closed
241 1, 2, 3 Sect-22, Meerut Road Gzb.
Shri Ram Piston & Rings Ltd.,
Bore well 150 125 Drain
242 MeerutRoad Ind. Area Gzb.
Sukrati Viddut Udyog Pvt.Ltd.,
Bore well 2.5 0.15 Drain
243 D-39, Meerut Road Gzb.
244 Techno Enterprises, A-13/12 Meerut Road Gzb. Bore well 1.5 1 Drain
245 Ultra Electroplaters, 46 Meerut Road Gzb. Bore well 3 2 Drain
Unichem Laboratories,
Bore well 200 40 Drain
246 C-31, Meerut Road Gzb.
247 Uttam Toyata, A-11, Meerut Road Ind Area Gzb. Bore well 20 20 Reuse
Zeeta Ind.Corporation Ltd., B-8, Meerut Road
Bore well Not available Not Available Drain
248 Gzb.
N.G. Textile Prints P.Ltd.,
Bore well 26.8 20 Drain
249 E-13/2, kavinagar ind.area ghaziabad
N.G. Textiles.,
Bore well 20.9 20 Drain
250 13A/10, Site-2, Loni Road I.A., Mohan NGR
ASHOKA PULP & PAPER PVT. Ltd.,
Closed Closed Closed Closed
251 11, Site-2, Loni Road LA, GZB.
Usha Cycle, E-9, S.S. of G.T. Road Ind. Area,
Bore well 19.3 6 Drain
252 GZB.
M/s Sheetal Industries,
S-40, South side Ind Area Bore well 4.5 3.5 Drain
253 G.T Road Ghazibad,
M/s Shivam Febrication P Ltd.,
Bore well 2 1.5 Drain
254 22/9, S.S. of G.T. Road Ind. Area, GZB.
M/s Silvirite Spokes Pvt. Ltd.
Bore well 4 3 Drain
255 S-28, S.S. of G.T. Road Ind. Area, GZB.
M/s Cosmos Engineering components, A- 7/79,
Bore well Not available Not available Not Aplicable
256 South side Ind area G.T Road, Ghaziabad
M/s Tarun International (P) Ltd.,
C-15 South Side Ind. Area G.T. Road , Bore well 20 4 Drain
257 Ghaziabad
M/s Sree Balaji Metals
Bore well 1 0.5 Drain
258 E-17 Kavi Nagar Industrial Area Ghaziabad
M/s A.C.E. Hardware Pvt Ltd,
B-5, Bulandshahar Road, Industrial Area, Tube well 7.5 3.5 Drain
259 Ghaziabad
M/s S.D Industries
Bore well 155 139 Not available
260 E124, B.S Industrial area, Ghaziabad
M/s N. G. Wash (formerly named as Apex Udyog)
I-4, Sec-D1, Apparel Park, Tronica City, Bore well 2 1.1 Drain
261 Ghaziabad
M/s Chacha Enterprises,
J-4, Sec. D-1(P-3), Apparel Park, Bore well 14 11 Drain
262 Tronica City, Loni.
M/s D.K. Jain,
G-262, Sector D-1(P), Aparels Park, Bore well 3 2.3 Drain
263 Tronica City, Loni, Ghaziabad.
M/s Deepak Gambhir,
E-12 Apparel Park, Sector D-1(P3), Bore well 28 20 Drain
264 Tronica City, Loni.
M/s Denim Matching,
Bore well 20 18.9 Drain
265 G-141, Apparel Park Tronica City, Ghaziabad
M/s Durgeshwari Garments Pvt. Ltd.,
E-13, Sector -13-1, Appral Park, Tronica City, Bore well 200 150 Drain
266 Loni Ghaziabad
M/s Ekansh Textile
K-36, Sec-D (1) Appreal Park Tronica City, Bore well 60 51.5 Drain
267 Loni, Ghaziabad
M/s Excellents Apparels Pvt. Ltd.,
K-52, Sect. D-1(P3), Apparels Park, Closed Closed Closed Closed
268 Tronica City. Loni Ghaziabad
GhanShyam Textiles,
K-19, Sector 13- 1 (P),
Closed Closed Closed Closed
Apparels Park, Tronica City,
269 Loni Ghaziabad.
M/s Galaxi Garments,
K-22, Sector D-1, Tronica City, Bore well 22 20 Drain
270 Apparel Park, Loni Ghaziabad.
M/s Gulshan Rai Jain,
G-82, Apparel Park, Bore well 21 15 CETP
271 Sector D-1 (P3), Tronica City, Loni,
J.B.S. Processors,
G-I04, Apparel Park, Closed Closed Closed Closed
272 Sector D-1 (P3), Tronica City, Loni, Gzb.
Jai Mata Di Dyers,
Bore well 21 20 CETP
273 1-9, Sect. D-1(P3), Tronica City, Loni.
Jai Shri Dyeing,
1-21, Apparel Park, Sector D-1(P3). Bore well 25 22 CETP
274 Tronica City, Loni.
63
Final mode of
Total Water Waste Water disposal of
Source of
Sl. No Name & Address of Industry Consumption in Generation generated
water supply
KLD in KLD Industrial
effluent
Laxmi Bleach,
D-102, Sec D-1(P3),Apparel Park, Tronica City, Bore well 20 18 CETP
275 Loni, Ghaziabad.
Laxmi Processors,
K-16, Sect-D-1, Pocket-3, Bore well 23 22 Not available
276 Appral Park, Tronica city
M.S. Trading,
E-15, Sector D-1(P), Bore well 18 15 CETP
277 Aparels Park, Troniea City, Loni.
Nandi Enterprises,
J-15. See D-1(P3), Bore well 18 16 CETP
278 Apparel Park, Tronica City, tent,
Nandi Enterprises,
K-14, Apparel Park, Bore well 22 18 CETP
279 Sector D-1 (P3), Tronica City, Loni,
National Industries,
G-264, Apparel Park, Bore well 10 8 CETP
280 Sector D-1(P3). Tronica City, Gzb.
Om Prakash Sharma,
J-11, Apparel Park. Bore well 40 35 CETP
281 Sector D-1(P3). Tronica City, Ghaztabad
Pooja Pahawa,
K-11, Apparel Park, Bore well 20 16 CETP
282 Sector D-1(P3), Tronica City, Loni.
Adunik Dyeing formally known as Puran Munjal,
H-12. Sector D-1(P), Aparels Park, Bore well 385 Not Available CETP
283 Tronica City, Loni,Ghazlabad
Quadri Processors,
Bore well 446 40 CETP
284 I-8, See D- 1(P3),.Apparel Park, Tronica City,
R.R. Impex
G-261, Sect. D-1 (P) Aparels Park Bore well 4 2 CETP
285 Tronica City Loni, GZB.
Rachita Processors,
K-33 & K-34. Sect. D1, Apparel Park, Bore well 39 20 CETP
286 Tronica City. Loni,Gzb
Ragging Sons
Bore well 10 2.5 CETP
287 I-13,Sect D -1 (P3) , Tronical City Loni Gzb.
Rajeev Kumar,
G-64, See D-1 (P3). Bore well 19.3 9.6 CETP
288 Apparel Park, Tronica City, Loni,
Robust Infra Tech P Ltd.,
J-13, Apparel Park, Bore well 18 16 CETP
289 Sector D-1(P3), Tronica City, _Lord. Ghaziabad.
Roop Trading Company,
E-14, sect-D- 1, pocket-3, Bore well 8 7 CETP
290 Appral Park, Tronica city, loni, Ghaziabad.
Roop Trading Company,
K-9, sect-D-1, pocket-3, Not applicable Not applicable Not applicable Not Aplicable
291 Appral Park, Tronica city, Loni haziabad.
Royal Techno Dyers,
K-47, Apparel Park, Closed Closed Closed Closed
292 Sector D-1(P3), Tronica City, Loni. Ghaziabad.
S.D. Garments,
1-2, Sector-D-1, pocket 3, Bore well 22 18 CETP
293 Appral Park, Tronica city, Loni, Ghaziabad.
S.T. Traders,
J-5, sector d-1 , Apparel park, Bore well 18 16 CETP
294 Tronica city , Loni, Ghaziabad
S.V.S. Fashion,
J-22, Apparel Park, Sector D-1(P3), Bore well 4 Not Available Drain
295 Tronica City, Loni, Ghaziabad.
Sai Saran Garment,
G-108, Apparel Park, Sector D-1(P3), Closed Closed Closed Closed
296 Tronica City, Loni. ghaziabad
Sandeep Tyagi,
G-271, Sec D-1(P3), Apparel Park, Bore well Not available Not Available CETP
297 Tronica City, Loni, Ghaziabad.
M/s Krish Garments (Sanjeev Kumar),
G-109, Sec D-1(P3), Apparel Park, Bore well 20 16 Drain
298 Tronica City, Loni, Ghaziabad.
Sara International,
G-65, Apparel Park, Sector D-1(P3), T Bore well Not available Not Available CETP
299 ronica City, Loni. Ghaziabad,
Shafali Dyeing,
G-84, Sector D-1(P), Aparels Park, Bore well 13.5 2.7 Drain
300 Tronica City, Loni. Ghaziabad
Shallu Prints,
G-121, Apparel Park, Sector D-1(P3), Closed Closed Closed Closed
301 Tronica City, Loni, Ghaziabad.
Shri Paras coloration (U.B. Dyeing),
G- 117, Sector d-1(P), Aparels Park, Bore well 32 18 CETP
302 Tronica City, Loni, Ghaziabad.
Siddhi Vinyak Tex,
H-11, Apparel Park, Sector D-1(P3),
Bore well 0.75 0.75 CETP
Tronica City, Loni, Ghaziabad.
303
64
Final mode of
Total Water Waste Water disposal of
Source of
Sl. No Name & Address of Industry Consumption in Generation generated
water supply
KLD in KLD Industrial
effluent
Siddhi Vinyak,
G-103, Apparel Park, Sector D-1(P3), Tronica Bore well 4 3.5 CETP
304 City, Loni, Ghaziabad.
Sudhir KumarJain,
G-80, Apparel Park, Sector D-1(P3), Tronica City, Bore well 20.5 16.5 CETP
305 Loni.
Sumer Mal (R.K. Export & Import),
H- 13, Apparel Park, Sector D-1(P3), Tronica Closed Closed Closed Closed
306 City. Loni.
M/s Sun Dyers,
I-19, Apparel Park, Sector D-1(P3), Tronica City, Closed Closed Closed Closed
307 Loni.
M/s Supreme Industries, J-2, Appral Park, tronca
Bore well 3 1.7 Drain
308 city, Loni.
M/s Tiwari Feb,
G-255, Apparel Park, Sector D-1(P3), Tronica Bore well 29 23 Drain
309 City, Loni.
Vaishali Hosiery,
1-17, Sector D-1, Apparel Park, Tronica City, Bore well 18 17 CETP
310 Loni, Gzb.
Vedanta Estate,
I-11, Apparel Park, Sector D-1(P3), Tronica City, Bore well 12.5 11 CETP
311 Loni. Gzb.
Vedanta Estate,
I-12, Apparel Park, Sector D-1(P3), Tronica City, Bore well Not available Not Available CETP
312 Loni. Gzb.
M/s Vedanta Estate,
J-12, Apparel Park, Sector D-1(P3), Tronica City, Bore well 20 19 CETP
313 Loni.
M/s U-Like Industry,
G-110, Apparel Park, Sector D-1(P3), Tronica Bore well 1.5 1.5 CETP
314 City, Loni.
M/s Spectrum Dye Studio Formerly known as M/s
Tusar Garments,
Bore well 20 20 CETP
J-3, Apparel Park, Sector D-1(P3), Tronica City,
315 Loni Ghaziabad
M/s Pradeep Kumar,
G-92, Apparel Park, Sector D-1(P3), Tronica City, Closed Closed Closed Closed
316 Loni.
M/s Silvertone Paper Ltd. (unit II)
Bore well 810 Not Available Drain
317 Bhopa Road, Muzaffarnagar
65
Annexure-XII
Location-wise Ground Water Not complying to IS10500-2012 w.r.to Drinking Water Specifications (acceptable limits)-Corrected
Weather GW
Depth of
Date of samples Total
Source of Ground water Sulfate Fluoride Cd Cu Pb Fe Ni Zn Mn Hg O&G
S.No. Name of the location District sample taken GPS Coordinates Cr Compliance
GW below ground (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (µg/l) (mg/l)
collection Industry (mg/l)
level
Premises
Drinking Water Specifications as per IS:10500-2012 (Acceptable Limits) in mg/l 200 1 0.003 0.05 0.01 0.3 0.02 5 0.1 0.001 - 0.05
M.K. Leather Trading Company, D-33, 28.5076939 N, Non
1 Greater Noida 04.04.2018 Yes Bore Well 8m 134 0.7 <0.002 <0.003 <0.013 - <0.003 0.03 1.03 <1 - <0.002
Site B, Surajpur, Greater Noida 77.494639 E Complying
Shree Jagdamba Knits (P) Ltd, P.No.- 28ᵒ30´46” N, Non
2 Greater Noida 05.04.2018 Yes Bore Well 12 m 123 0.6 <0.002 <0.003 <0.013 - <0.003 0.3 0.1 1.16 - <0.002
95,105, Site-B, Surajpur, Greater Noida 77.28’45” E Complying
Sky Lark Dyeing (P) Ltd.,Plot No.- B-2/14, 28.513474 N, Non
3 Greater Noida 04.04.2018 Yes Bore Well 30 m 45 0.6 <0.002 <0.003 <0.013 - <0.003 0.03 0.14 <1 - <0.002
Site-B, Surajpur Greater Noida 77.504007 E Complying
Yamaha Motor India (P) Ltd., Noida-Dadri Non
4 Greater Noida 13.03.2018 Yes Bore Well - 13 m 47 1.1 <0.002 0.02 <0.013 0.01 <0.003 0.01 <0.002 <1 - <0.002
Road, Greater Noida Complying
M/s Autotech Steel Engineering (P) Ltd,
28.4378824 N, Non
5 Plot.No. 28/3, Ecotech-I, Extn-I,Greater Greater Noida 13.03.2018 Yes Bore Well 8.5 m 20 1.2 <0.002 0.05 <0.013 0.43 <0.003 0.05 0.04 <1 - <0.002
77.5604753 E Complying
Noida
IGL CNG filling station Block I, Beta II, Non
6 Greater Noida 13.03.2018 No Bore Well - - 15 0.6 <0.002 0.06 <0.013 0.05 <0.003 0.19 0.01 <1 - -
Greater noida, U.P. Complying
Non
7 Devla village, Dadri road, Greater Noida Greater Noida 08.03.2018 No Hand Pump - - 40 0.5 <0.002 <0.003 0.26 - <0.003 0.07 - <1 - -
Complying
M/s Garg Tube Co. Ltd. Vill- Chhaproulla, 28.6088728 N, Non
8 Greater Noida 07.03.2018 Yes Bore Well 10.26 m 35 0.4 <0.002 <0.003 <0.013 - <0.003 <0.002 - 1.52 2 -
G.T.Road, Gr.Noida 77.4957853 E Complying
Hand Pump of Vishnuli Village, Near Hero 28.6042 N, Non
9 Greater Noida 07.03.2018 No Hand Pump 7.7 m 42 0.5 <0.002 <0.003 <0.013 - <0.003 1.75 - 1.52 - -
Motors 77.4981 E Complying
Meeta India Ltd., Plot No 21/2, Site II, 28.6796 N, Non
10 Ghaziabad 11.04.2018 Yes Bore Well 30 m 85 1.7 <0.002 <0.003 <0.013 - <0.003 0.01 - <1 - -
Loni Road, Mohan Nagar Gzb. 77.381963 E Complying
M/s J.M.V.L.P.S. Ltd., (Ex Name J.M.V.
28°31’14”N, Non
11 Earthing Equipment pvt. Ltd) Plot No- J- Greater Noida 12.03.2018 Yes Bore Well 12 m 111 0.8 <0.002 0.22 <0.013 - <0.003 0.15 - <1 - -
77°30’57”E Complying
12, Site-C, UPSIDC, GR. NOIDA
M/s JBM Autotech, PLOT NO-J- 5, SITE -C 28.53 N, Non
12 Greater Noida 12.03.2018 Yes Bore Well 12 m 229 0.6 <0.002 0.01 <0.013 - 0.01 <0.002 - <1 - -
, Gr.Noida 77.51 E Complying
M/s Bir Horizons Pvt. Ltd. ,PLOT NO.F-79, 28°30’40.6”N, Non
13 Greater Noida 08.03.2018 Yes Bore Well - 60 0.7 <0.002 <0.003 <0.013 <0.002 <0.003 <0.002 0.16 <1 - -
SITE-B, Surajpur, Gr.Noida 77°29’47.6”E Complying
Non
14 Nangla Dairy Greater Noida 08.03.2018 Yes Hand Pump - 50 m 18 0.6 <0.002 <0.003 <0.013 1.29 <0.003 0.14 0.06 <1 - <0.002
Complying
29.127228 N, Non
15 Village Mandhiyai, Meerut Main Road Meerut 05.03.2018 No Hand Pump 83 m - 1.1 <0.002 <0.003 <0.013 - <0.003 0.11 - <1 - -
77.608529 E Complying
Hand Pump Near M/s Ramala Sahkari 29.235139 N, Non
16 Baghpat 07.03.2018 No Hand Pump 16 m - 1.1 <0.002 <0.003 <0.013 - <0.003 1.16 - <1 - -
Chini Mills Ltd, Ramala, Bagpat 77.284237 E Complying
Inside Parmedical College Premises, 29°28’61.91”N Non
17 Muzaffarnagar 07.03.2018 No Hand Pump 44 m - 0.3 0.74 <0.003 0.28 - <0.003 2.95 - <1 - -
Village Bagra 77°55’58”E Complying
Near M/s Bajaj Hindustan Ltd. Bhaisana, 29.294250, Non
18 Muzaffarnagar 07.03.2018 No Hand Pump 50 m - 0.12 <0.003 <0.013 - <0.003 1.96 - 1.52 - -
Muzaffarnagar 77.493759 Complying
29°21'18.8" N, Non
19 Main road, Mansurpur village Muzaffarnagar 06.03.2018 No Hand Pump 50 m 52 0.3 <0.002 <0.003 <0.013 - <0.003 0.15 - 1.3 2 -
77°42'50.1" E Complying
66
Weather GW
Depth of
Date of samples Total
Source of Ground water Sulfate Fluoride Cd Cu Pb Fe Ni Zn Mn Hg O&G
S.No. Name of the location District sample taken GPS Coordinates Cr Compliance
GW below ground (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (µg/l) (mg/l)
collection Industry (mg/l)
level
Premises
Drinking Water Specifications as per IS:10500-2012 (Acceptable Limits) in mg/l 200 1 0.003 0.05 0.01 0.3 0.02 5 0.1 0.001 - 0.05
29°16’44.4”N, Non
20 Tehsil Katauli Muzaffarnagar 03-06-2018 No Hand Pump 50 m 14 0.3 <0.002 <0.003 <0.013 - <0.003 0.09 - 1.3 2 -
77°44’19.4”E Complying
Non
21 Mansurpur NH 58 on road Muzaffarnagar 06.03.2018 No Hand Pump - 50 m 76 0.3 <0.002 <0.003 <0.013 - <0.003 9.12 - 1.26 2 -
Complying
Tube Well near of M/s Silvertone Paper 29°28’ 00.15’’ N, Non
22 Muzaffarnagar 16.04.2018 No Tube Well 18.29 m 208 0.3 <0.002 <0.003 <0.013 - <0.003 <0.002 - <1 - -
Ltd (Init 1) Bhopa Road, Muzaffarnagar 77 °47’05.60’’ E Complying
Industry premises of M/S Tehri Pulp &
29.471 N, Non
23 Papers Ltd. (Unit-I), 9th Km Stone, Bhopa Muzaffarnagar 12.04.2018 Yes Bore Well E 40 m 4 0.5 <0.002 <0.003 <0.013 - <0.003 0.05 - 1.26 - -
77.796 Complying
Road, Muzaffarnagar
M/S Suyash Craft & Papers Ltd.Village- 29.426 N, Non
24 Muzaffarnagar 13-04-2018 Yes Bore Well 40 m 11 0.3 <0.002 <0.003 <0.013 - <0.003 0.14 - 1.01 - -
Velhana, Meerut Roadf, Muzaffarnagar 77.692 E Complying
Industry premises of M/S Shri 29.472 N, Non
25 Muzaffarnagar 12.04.2018 Yes Bore Well 45 m 6 0.3 <0.002 <0.003 <0.013 - <0.003 0.01 - 1.52 - -
Bhageshwari Paper Mills (P) 77.491 E Complying
Near M/s. Arihant Pulp & Papers Ltd., 29.437478 N, Non
26 Muzaffarnagar 08.03.2018 No Hand Pump 13 m 41 0.3 <0.002 <0.003 <0.013 10.42 <0.003 1.9 0.09 <1 - <0.002
opposite cement godwon, musa bilaspur 77.745673 E Complying
Near M/s Siddeshwari industries Pvt.
29°25’8”N, Non
27 Ltd., 8.6 Km Jansath Road, Muzaffarnagar 08.03.2018 No Hand Pump 61 m 30 0.1 <0.002 <0.003 <0.013 0.17 <0.003 <0.002 0.87 - - <0.002
77°45’36”E Complying
Muzaffarnagar
M/s K.K. Duplex & Paper mill Pvt. Ltd.,
29°42’37.38”N, Non
28 8.5 Km Stone, Jansath Road, Muzaffarnagar 08.03.2018 Yes Bore Well 46 m 43 0.1 <0.002 <0.003 <0.013 0.09 <0.003 <0.002 0.23 - - <0.002
77°75’87.43”E Complying
Muzaffarnagar
M/s Silver Tone Pulp & Paper, 9th Km 29°27’59.8”N, Non
29 Muzaffarnagar 08.03.2018 Yes Bore Well 70 m 25 0.5 <0.002 <0.003 <0.013 0.01 <0.003 <0.002 0.27 - - <0.002
Stone, Bhopa Road, Muzaffarnagar. 77°47’17”E Complying
Near M/s. Ravi Organics Ltd., Begrajpur, Non
30 Muzaffarnagar 13.04.2018 No Hand Pump - - 20 0.2 <0.002 <0.003 <0.013 - <0.003 0.89 - 1.26 2 -
Muzaffarnagar Complying
M/s. H.J. Tannery ,9th Km, Jansath Road, Non
31 Muzaffarnagar 13.04.2018 Yes Tube Well - - 41 0.2 <0.002 <0.003 <0.013 - <0.003 <0.002 - 1.01 - -
Muzaffarnagar Complying
29.442825 N, Non
32 Meerut Karnal road, Near Bypass Shamli Shamli 06.04.2018 No Hand Pump 60 m 32 0.8 <0.002 <0.003 <0.013 - <0.003 0.66 - 1.33 - -
77.314561 E Complying
50m away from M/s Bajaj Hindustan Ltd., 29.5693 N, Non
33 Shamli 07.04.2018 No Hand Pump - 2 0.4 <0.002 <0.003 <0.013 - <0.003 0.24 - 1.16 - -
Thanabhawan, Muzaffarnagar 77.408405 E Complying
Near M/s. Shamli Distillery & 29.442825 N, Non
34 Shamli 06.04.2018 No Hand Pump 60 m 32 0.8 <0.002 <0.003 <0.013 - <0.003 0.66 - 1.33 - -
Chem.Work, Shamli 77.314561 E Complying
Outside M/s Co-operative Co. Ltd., Tapri, 29554’57.3”N, Non
35 Saharanpur 09.04.2018 No Hand Pump 35 m 122 0.2 <0.002 <0.003 <0.013 - <0.003 6.63 - <1 - -
Saharanpur 77°35’40.0”E Complying
Asheram Nirwad S/o Badlu Singh, H.No.-
28.686965, Non
36 512 Village- Karheda, Near Mohan Nagar Ghaziabad 03.04.2018 No Borewell 49m 31 2 <0.002 <0.003 <0.013 0.02 <0.003 0.01 - 1.66 - <0.002
77.385494 Complying
Loni Road Ghaziabad
Non
37 Outside Star Paper Mill Saharanpur Saharanpur 06.03.2018 No Hand Pump - - 62 0.2 <0.002 <0.003 <0.013 1.43 <0.003 1.3 - <1 2 -
Complying
Near Plaza Paper P.Ltd. Village Non
38 Saharanpur 06.03.2018 No Hand Pump - - 65 0.2 <0.002 <0.003 <0.013 1.5 <0.003 <0.002 - <1 2 -
Maheswari Khurd Complying
Near Rainbow Board Mill, (Unit Kraft Non
39 Saharanpur 06.03.2018 No Hand Pump - - 30 0.2 <0.002 <0.003 <0.013 0.62 <0.003 0.12 - <1 2 -
Paper), Near naugara Peer, Saharanpur Complying
Near Swaroop Paper (P) Ltd., Near Janta Non
40 Saharanpur 06.03.2018 No Hand Pump - - 27 0.3 <0.002 <0.003 <0.013 0.22 <0.003 0.04 - 2 2 -
Road, Saharanpur Complying
67
Weather GW
Depth of
Date of samples Total
Source of Ground water Sulfate Fluoride Cd Cu Pb Fe Ni Zn Mn Hg O&G
S.No. Name of the location District sample taken GPS Coordinates Cr Compliance
GW below ground (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (µg/l) (mg/l)
collection Industry (mg/l)
level
Premises
Drinking Water Specifications as per IS:10500-2012 (Acceptable Limits) in mg/l 200 1 0.003 0.05 0.01 0.3 0.02 5 0.1 0.001 - 0.05
Hand pump near Nagar Nigam
Non
41 Pashuvadhshala, kamela colony, Saharanpur 06.03.2018 No Hand Pump - 40 m 33 0.7 <0.002 <0.003 <0.013 2.16 <0.003 0.04 - <1 2 -
Complying
Saharanpur
Near M/s Atul Textile Industried Ltd.,
29.985548 N, Non
42 Shakumabari Vihar, Behat Road, Saharanpur 07.03.2018 No Hand Pump 55 m 11 0.3 <0.002 <0.003 <0.013 - <0.003 1.76 - 1.01 2 -
77.568758 E Complying
Saharanpur
Near M/s Shalimar Cotton Dyeing,
29.996889 N, Non
43 Saharanpur Behat Road, Rasulpur, Saharanpur 07.03.2018 No Hand Pump 55 m 220 0.3 <0.002 <0.003 <0.013 - <0.003 <0.002 - 1.51 2 -
77.566726 E Complying
Saharanpur
Near M/s S.M.C. Foods Ltd. Nnauta, 28°54’11.5”N, Non
44 Saharanpur 07.03.2018 No Hand Pump 15.2 m 33 0.3 <0.002 <0.003 <0.013 - <0.003 0.57 - 1.51 2 -
Saharanpur 77°50’54.5”E Complying
M/s Pashupati Dairy (P) Ltd. Village
Non
45 Kumharhera, Dehradun Road, Saharanpur 17.04.2018 Yes Bore Well - 60 m 27 0.3 <0.002 <0.003 <0.013 <0.002 <0.003 <0.002 0.29 - - <0.002
Complying
Saharanpur
Near M/s Jayna Gramodyaog Sansthan, 29.983602 N, Non
46 Saharanpur 04.04.2018 No Hand Pump 35 m 19 0.1 <0.002 <0.003 <0.013 - <0.003 6.07 - <1 2 -
Gagalheri 77.665811 E Complying
29.979749 N, Non
47 Gagalheri, Dehradun, Saharanpur Saharanpur 05.03.2018 No Hand Pump 44 m 5 0.6 <0.002 0.15 0.09 - <0.003 1.05 - <1 - -
77.668548 E Complying
M/s Balaji Wire Pvt. Ltd., 139·A, Anand 28.674894 N, Non
48 Ghaziabad 07.03.2018 Yes Hand Pump 45 m 89 0.5 <0.002 <0.003 <0.013 0.12 <0.003 0.39 - 1.72 - <0.002
Industrial Estate Mohan Nagar, Gzb. 77.388494 E Complying
Mohan Meakins Ltd., Mohan Nagar, 28°40’17.5”N Non
49 Ghaziabad 08.03.2018 Yes Bore Well 25 m 96 0.8 <0.002 0.01 0.04 <0.002 <0.003 <0.002 - 1.01 - <0.002
Ghaziabad 77°23’01.0”E Complying
Near M/s AB Cycle Parts Pvt. Ltd. at Ispat
28°38’23.6”N Non
50 Nagar, Buland Sahar Road Industrial Ghaziabad 08.03.2018 No Hand Pump 40 m 71 0.5 <0.002 <0.003 0.08 6.28 <0.003 1.24 - <1 2 0.02
77°26’37.6”E Complying
Area, Ghaziabad.
Near Balaji Enterprises, B-22/1/15, 28.6484380 N, Non
51 Ghaziabad 13.03.2018 No Hand Pump - 135 0.4 <0.002 0<.003 <0.013 0.72 <0.003 0.27 - - 2 <0.002
B.S.Road Ind. Area Gzb. 77.4594966 E Complying
Near Indian Textiles Co., E-49, B.S. Road, 28.6484381 N, Non
52 Ghaziabad 09.03.2018 No Hand Pump - 330 0.8 <0.002 0.01 <0.013 1.47 <0.003 0.11 - <1 - -
Gzb. 77.4594767 E Complying
Near M/s Lion Cycle & Rikshaw 28.6424919 N, Non
53 Ghaziabad 12.03.2018 No Hand Pump - 109 0.7 <0.002 <0.003 <0.013 <0.002 <0.003 <0.002 - 1.01 - -
Industries, E·l0, B.S. Road Ind. Area Gzb. 77.4609803 E Complying
Near Progressive Tools & Component 28.642382 Non
54 Ghaziabad 03.04.2018 No Handpump 46 m 203 0.6 <0.002 <0.003 <0.013 0.72 <0.003 0.27 - <1 - -
Pvt.Ltd. C-222, B.S. Road Ind. Area , Gzb 77.460819 Complying
From tube well situated in premises of
Masjid , besides the road towards the 28.639554 N, Non
55 Ghaziabad 11.04.2018 No Hand pump - 35 0.5 <0.002 <0.003 <0.013 - <0.003 0.02 - 1.83 2 <0.002
unit M/s Shivam Engineering and 77.446274 E Complying
Fabrication
Near M/s Tarun International C-15, SS of 28.6377376 N, Non
56 Ghaziabad 05.04.2018 No Bore well - 44 0.4 <0.002 <0.003 <0.013 0.13 <0.003 <0.002 0.21 1.16 2 <0.002
GT road, Ghaziabad 77.44111755 E Complying
M/s Al Nafees Frozen Foods Export, 28.685079 N, Non
57 Ghaziabad 06.04.2018 Yes Hand Pump 13 m 56 1 <0.002 <0.003 <0.013 - <0.003 0.65 - 1.66 2 -
Hapur Rd. Dasna Ghaziabad 77.540928 E Complying
M/s International agro Foods (Integrated
slaughter House) Plot no. 2764 - 2766,
Non
58 Bhurgardi, Dasna, Distt. Ghaziabad Uttar Ghaziabad 08.03.2018 Yes Borewell - 29 m 30 1.3 <0.002 <0.003 <0.013 0.1 <0.003 0.24 - - - <0.002
Complying
Pradesh
68
Weather GW
Depth of
Date of samples Total
Source of Ground water Sulfate Fluoride Cd Cu Pb Fe Ni Zn Mn Hg O&G
S.No. Name of the location District sample taken GPS Coordinates Cr Compliance
GW below ground (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (µg/l) (mg/l)
collection Industry (mg/l)
level
Premises
Drinking Water Specifications as per IS:10500-2012 (Acceptable Limits) in mg/l 200 1 0.003 0.05 0.01 0.3 0.02 5 0.1 0.001 - 0.05
Non
59 Dasna Village Ghaziabad 08.03.2018 No Borewell - - 40 0.6 <0.002 <0.003 0.02 1.77 <0.003 0.04 -- - - <0.002
Complying
Non
60 Bhurgadi Village (Private) Ghaziabad 08.03.2018 No Borewell - - 136 2.5 <0.002 <0.003 <0.013 1.56 <0.003 1.56 -- - - 0.05
Complying
Non
61 Bhurgadi Village(Government) Ghaziabad 08.03.2018 No Borewell - - 41 0.7 <0.002 <0.003 <0.013 1.84 <0.003 0.21 - - - 0.26
Complying
Rajeev Colony, adject to M/s Ambica 28.682150 N, Non
62 Ghaziabad 08.03.2018 No Hand Pump 33 m 26 2.4 <0.002 <0.003 <0.013 <0.002 <0.003 1.09 - <1 - <0.002
Steels Ltd., Mohan Nagar Ghaziabad 77.381735 E Complying
M/s Bansal Wire Industries Ltd, B-3, Loni Non
63 Ghaziabad 07-03-2018 No Hand Pump Ghaziabad - 95 0.5 <0.002 0.05 <0.013 1.33 0.02 8.58 - <1 - <0.002
road, Mohan Nagar, Ghaziabad, U.P. Complying
The Kisan Sahakari Chini Mill, Nanouta, 29.4237N, Non
64 Saharanpur 11-04-2018 Yes Hand Pump 50 m 19 0.4 <0.002 <0.003 0.07 11.26 <0.003 4.15 0.16 - - <0.002
sahranpur UP 77.2644E Complying
29.5749N, Non
65 Daya Sugar Gagalheri, Saharanpur, U.P Saharanpur 10-04-2018 Yes Hand Pump 30 m 2 0.2 <0.002 <0.003 <0.013 9.9 <0.003 1.79 0.05 - - <0.002
77.3934E Complying
Triveni Engg. & Industires Ltd., Deoband, 29.4020N, Non
66 Saharanpur 10-04-2018 Yes Hand Pump 30 m 176 0.5 <0.002 <0.003 <0.013 8.83 <0.003 1.34 0.21 - - <0.002
saharanpur, U.P 77.4099E Complying
Bajaj Hindustan Sugar Ltd., Gangoli 29.4835N, Non
67 Saharanpur 10-04-2018 Yes Hand Pump 30 m 16 0.1 <0.002 <0.003 <0.013 2.77 <0.003 1.1 0.17 - - <0.002
Saharanpur, U.P 77.3258E Complying
Vaishali Hosiery, 1-17, Sector D-1, Non
68 Ghaziabad 19.04.2018 Yes Borewell - 30 m 49 0.4 <0.002 1.25 <0.013 <0.002 0.02 0.3 - <1 - -
Apparel Park, Tronica City, Loni, Gzb. Complying
Sunny Prints, 5/7, Site-II Industrial Area, 28,41,10 N Non
69 Ghaziabad 09-03-2018 Yes Bore Well 35 m 122 0.8 <0.002 <0.003 <0.013 - <0.003 <0.002 - 1.01 10 -
Loni Road, GZB. 77,22,53E Complying
Albert David Ltd., B-13, Meerut Road 28,41,05N Non
70 Ghaziabad 08-03-2018 Yes Bore Well 30 m 33 0.5 <0.002 <0.003 <0.013 - <0.003 <0.002 - 1.52 - -
industrial Area Ghaziabad. 77,26,10E Complying
Parle Agro P Ltd. A-7, Sector-22 Meerut 34 0.5 - - - 0.02 - 1.01 - Non
71 Ghaziabad 09-03-2018 Yes Bore Well - 50 m <0.002 <0.013 <0.002
Road, Ind. Area, Gzb. Complying
E.C.E. Ltd., A-20, Meerut Road Ind. Area 49 0.6 - 0.05 0.07 - 0.07 Non
72 Ghaziabad 13.03.2018 Yes Bore Well - 50 m <0.002 <0.013 <0.003 <1 2
Gzb. Complying
Near boundry well of M/s ML Batra 28.686521, 23 0.6 0.04 - 0.1 - 0.41 - 1.3 - Non
73 Ghaziabad 05-03-2018 No Hand Pump - <0.003 <0.002
enterprisis 77.438617 Complying
Marshal Cycles, B-17/18, Meerut Road 28.689877, 24 0.8 - 0.07 - - 2.16 - Non
74 Ghaziabad 05-03-2018 Yes Bore Well 60 m <0.002 <0.003 <0.002 <0.002
Industrial Area Gzb. 77.441113 Complying
North Land Cycle Co. Ltd., D-21, meerut 28.685197, 17 0.4 - - 0.01 - 1.48 - 0.02 Non
75 Ghaziabad 07-03-2018 Yes Bore Well 50 m <0.002 <0.013 <0.003
Road Industrial Area Ghaziabad 77.438298 Complying
Industrial area hand pump meerut road Non
76 Ghaziabad 9.3.2018 no Handpump - - 27 0.5 <0.002 <0.003 <0.013 0.69 <0.003 0.04 - <1 2 0.2
ghaziabad Complying
Sukrati Viddut Udyog Pvt.Ltd., D-39, Non
77 Ghaziabad 5.3.2018 Yes Borewell - - 36 0.4 0.03 0.15 0.09 0.04 <0.003 0.05 - <1 2 <0.002
Meerut Road Gzb. Complying
22.684 N, Non
78 DPS gate Railway crossing Ghaziabad 8.3.2018 No Handpump 66 m 15 0.3 <0.002 <0.003 <0.013 21.81 <0.003 2.21 0.1 <1 2 0.02
77.434 E Complying
28.686512 N, Non
79 Karhoda village Ghaziabad 7.3.2018 No Handpump 66 m 15 1.8 <0.002 <0.003 <0.013 0.48 <0.003 0.22 <0.002 1.12 2 <0.002
77.387415 E Complying
28.63 N, Non
80 Doondaheda village, SS of GT road, Gzb Ghaziabad 06.03.2018 No Hand Pump 40 m 64 0.6 <0.002 <0.003 <0.013 2.14 0<.003 1.04 - <1 - <0.002
77.44 E Complying
Sain Vihar, near Sarthak public school, Non
81 Ghaziabad 05.03.2018 No Hand Pump - 40 m 26 0.8 <0.002 <0.003 <0.013 0.73 <0.003 0.06 - <1 - -
NH-24, Ghaziabad Complying
69
Weather GW
Depth of
Date of samples Total
Source of Ground water Sulfate Fluoride Cd Cu Pb Fe Ni Zn Mn Hg O&G
S.No. Name of the location District sample taken GPS Coordinates Cr Compliance
GW below ground (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (µg/l) (mg/l)
collection Industry (mg/l)
level
Premises
Drinking Water Specifications as per IS:10500-2012 (Acceptable Limits) in mg/l 200 1 0.003 0.05 0.01 0.3 0.02 5 0.1 0.001 - 0.05
Slum Area Kavi Nagar B.S. Road 28.65741 N, Non
82 Ghaziabad 07.03.2018 No Hand Pump - 25 0.5 <0.002 <0.003 <0.013 2.19 <0.003 0.06 - <1 - 0.26
Ghaziabad 77.46966 E Complying
28.664233 N, Non
83 Shastri Nagar Ghaziabad Ghaziabad 07.03.2018 No Hand Pump - 21 0.4 <0.002 <0.003 <0.013 2.57 <0.003 1.06 - <1 - 0.03
77.458378 E Complying
04.04.2018 Non
84 Durgawati Loni, Ghaziabad Ghaziabad No Hand Pump - - 51 0.5 <0.002 <0.003 <0.013 0.51 <0.003 0.22 0.11 <1 - <0.002
Complying
Handpump near Edgah, Ansal, Loni, 04.04.2018 Non
85 Ghaziabad No Hand Pump - - 88 0.6 <0.002 <0.003 <0.013 1.13 <0.003 <0.002 0.08 <1 - <0.002
Ghaziabad Complying
28.78906 N , Non
86 Handpump Near Agrola Village Ghaziabad 08.03.2018 No Hand Pump - 103 0.3 <0.002 <0.003 1.74 4.66 <0.003 0.19 - 1.76 2 <0.002
77.286497 E Complying
28.720358 N, Non
87 Agrola Village, Near Balaji Temple Ghaziabad 09.03.2018 No Hand Pump - 139 0.5 <0.002 <0.003 <0.013 3.94 <0.003 0.03 - 1.26 2 <0.002
77.287163 E Complying
Hand Pump, Near to Hanuman mandir, 28.7894 N, Non
88 Ghaziabad 06-03-2018 No Hand Pump 24 m 109 0.4 <0.002 <0.003 <0.013 10.69 <0.003 0.37 - 1.66 - -
Village-Agraula , Tronica City, Loni 77.2868 E Complying
Hand pump near to mohd. Yameen, Om 28.789 N Non
89 Ghaziabad 06-03-2018 No Hand Pump 36 m 47 0.5 <0.002 <0.003 <0.013 0.43 <0.003 0.12 - 1.12 2 -
Sai City, Vill Agraula, Tronica city, Loni 77.284 E Complying
Hand pump, village pakhi sadakpur, 1 Non
90 Ghaziabad 07-03-2018 No Hand Pump - 43 m 21 0.6 <0.002 <0.003 <0.013 0.42 <0.003 0.24 - - 2 <0.002
km, Tronica city Complying
Village Agraula Tronika City Loni 29° 47' 17.6"N Non
91 Ghaziabad 06-03-2018 No Handpump 67 m 41 0.5 <0.002 <0.003 <0.013 0.01 <0.003 <0.002 - 1.52 - -
Ghaziabad 77° 17' 41.2"E Complying
28.763003 N Non
92 Road Side Hand Pump Near Tronica City Ghaziabad 07.03.2018 No Borwell 26 m 65 0.2 0.03 <0.003 0.03 - <0.003 0.12 - 1.52 2 -
77.283391 E Complying
28.676 N, Non
93 Village Bhoorgarhi, Dasna, Gzb Ghaziabad 26.04.2018 No Hand Pump 40 m 136 1.8 <0.002 0.03 <0.013 0.14 <0.003 <0.002 0.19 <1 2 0.03
77.37726 E Complying
70
Annexure-XIII
Industry wise observations and recommendations made by the Joint Inspection Teams
Name of he
Sl. Date of
Name & Address of Industry industrial Main observation of the visited team Recommendations
No. inspection
Sector
Adarsh Thermopack Industries (P) Unit may be asked to install flow meter at raw water
1 09.03.2018 Tannery Units may be asked to install flow meter at raw water intake pump
Ltd, E-106, Site B, Surajpur, Greater Noida intake pump.
Aricab Fab (P) Ltd,
2 09.03.2018 Textile & Dyeing Closed closed
C-4, Site-4, Surajpur, Greater Noida
1. Unit may be asked to install Flow meter at Raw
Chaudhary Skin Trading Company, water intake pumps as well as at the outlet of ETP.
3 09.03.2018 Sloughter House Analysis results entered
D-34, Site-B, Surajpur, Greater Noida 2. Unit shall be asked to comply with the effluent quality
standards (O&G).
1. Unit may be asked to install Flow meter at Raw
Colour & Style (P) Ltd, Unit may be asked to install flow meter at raw water intake pumps as well as at the outlet water intake pumps as well as at the outlet of ETP.
4 09.03.2018 Textile & Dyeing
A-1/2, 8/9, Site-B, Surajpur, Greater Noida of ETP. 2. Unit shall be asked to comply with the effluent quality
standards (O&G).
The waste water sample analysis report of STP outlet and ETP Outlet given by Newton
consultants and laboratories are meeting the prescribed standard of BOD and COD. The
Continental Milkose (India) Ltd, Unit may be asked to inform whenever it resumes the
5 09.03.2018 Dairy stack emission monitoring and analysis report for particulate matter, and gases like CO
Habibpur, Kulesra, Greater Noida operation, for inspection.
were within the specified limit as per the CPCB criteria, while for SO2 and NO2 the limit
were not prescribed.
Honda Cars India Ltd, As industry is capable of obtaining zero discharge,
6 Plot no A-1, Sector40/41, Surajpur, Kasna Road, 09.03.2018 Automobile Analysis results entered accordingly directions may be issued to industry to
Greater Noida, U.P. achieve zero discharge in time bound manner
7 Hotz Industies Udyog Vihar, Greater Noida 04.04.2018 Textile & Dyeing - -
1) Unit Operational at the time of inspection and consent is valid upto 31.12.2019. HW
authorization dated 1.8.2014 and valid upto 5 years 2) Manufacturing process include
mainly pretreatment, washing and assembly of products such as Refrigerator, washing
machine and Microwave, A.C. compressor and Compressor motor 3) Effluent generated
M/S LG Electronics,
Electrical & from the process is collected and treated (physio- chemical treatment) through ETP-1 and No action proposed as the industry genrally meets the
8 Plot no 51, Udyog Vihar , Surajpur, Kasna Road, 04.04.2018
Electronics ETP-2. 4) Treated effluent is collected in a common collection tank and used for norms
Greater Noida, UP
gardening purpose, log book for ETP operations are available 5) one treated effluent
sample from the ETP outlet and one GW sample (borewell) were collected and handed
over to Lab for analysis and results are awaited.. 6) OCEMS not installed/connected 7) 4
bore wells in use and CWGA permission is yet to be obtained
71
1. Industry operational and consent is valid upto 31.12.2019 Hazardous waste (HW)
authorization-yet to be obtained 2.Unit process sheep/goat hides to wet blue finishing,3.
installed 5 drums to process the same. 3. One treated effluent sample from ETP outlet
and one GW sample were collected.4. ETP operation not satisfactory as no settlement of
suspended solids observed indicating absence of MLSS. 5.Installed online effluent Directions may be issued based on ETP operation,
M.K.leather Trading Company,
9 04.04.2018 Tannery monitoring system for pH, TSS, COD, BOD and flow, and flow meter reading was found installed monitoring system and poor housekeeping as
0-33, Site B, Surajpur, Greater Noida
erroneous, OCEMS needs calibration and maintainance.6.No log book for ETP operations well as higher manganese levels in gwound water .
and OCEMS 7.No proper collection and storage facilities 8. Solid wastes are found
dumped in open areas and no proper collection ans storage facilities. 9. Housekeeping
not satisfactory 10.One bore well in use and no flow meter installed, permission from
CGWA to be obtained.
1) Unit is operational at the time of visit. HW authorization dated 5.05.14 and is valid for 5
years
2) Manufacturing process include dyeing and printing of various types of fabrics
3) Effluent generated is collected and treated (physio- chemical treatment) through ETP.
Shree Jagdamba Knits (P) Ltd, Treated effluent is discharged into a drain outside the factory which joins hawalia drain
Directions may be issued based on BOD level in ETP
10 P.No.-95,105, Site-B, Surajpur Industrial Area, 05.04.2018 Textile & Dyeing and then Hindon river.
outlet sample, whish is exceeding the prescribed limit .
Greater Noida 4) Log book for ETP operations not available.
5) One treated effluent sample from ETP outlet discharged in the drain and one GW
sample (bore well) collected and handed over to lab for analysis and results awaited.
6) No flow meter installed in borewell..CGWA authorization is yet to be obtained.
7) OCEMS not installed/connected.
1)Unit Operational at the time of inspection, and consent valid upto 31.12.2019. HW
authorization dated 27.3.17 and is valid for 2 years 2)Manufacturing process includes
mainly engineering, fabrication, machining, painting, assembling 4) Effluent generated
M/S Gabriele Lucano CNH Industrial India Pvt LTd
from the paint shop, machine shop and assembly lines are collected and treated in ETP
formerly known as M/s New Holland Fiat (India)
consisting equalization tank, flash mixer, primary clarfier, aeration tank, secondary The unit generally complies with the norms and no
11 Pvt. LTd., 05.04.2018 Automobile
clarifier, and mutigrade filter system .5) Treated effluent is collected in collection tank action is proposed.
Plot no 3 Udyog kendra, Ecotech-III, Greater Noida,
and used for gardening purpose, Log book for ETP operations not available 6) 2 borewells
U.P.
in use, authorization from CWGA is yet to be obtained 7) One treated effluent sample
from ETP outlet and one GW sample (borewell) collected , results awaited 8) OCEMS not
installed /connected.
·Unit operational and consent is valid upto 31.12.2018 2.HW authorization dated
7.12.2015 with a validity for 5 years 3. Manufacturing process includes bleaching and
dyeing of various types of fabrics 4.Effluent generated is collected and treated (physio
chemical treatment) through ETP. Treated effluent is discharged into the drain outside
Sky Lark Dyeing (P) PVT LTd, Direction may be issued based on no complaince of ETP
12 04.04.2018 Textile & Dyeing the factory which joins Hawalia drain and then Hindon river. 5) Log book for ETP
Plot No.- B-2/14. Site-B, Surajpur, Greater Noida outlet sample for pH, BOD, TSS, & Oil and Grease
operations not available. 6) One treated effluent sample from ETP outlet discharged in
the drain and one GW (borewell) handed over to lab 7) .No flow meter installed at ETP
inlet and ETP outlet 8) One bore well in use and permission from CGWA is yet to be
obtained.8.OCEMS not installed/connected
72
As the existing ETP treated water is not complying w.r.to
the BOD and therfore unit is required to take action for
augmentation of the existing ETP and operated properly
so as to comply wih the discharge norms prescribed by
UPPCB. Paint sludge generated may be sold or
auctioned only to the paint sludge recyclers approved
Housekeeping of the unit is very good.Unit is having valid consent and
under HW & other waste (M & TM )rules 2016 or
authorization.Treated water about 500 KLD is discharged into drain which meets hawalia
feasiblity of covering paint sludge into primer onsite may
M/S Yamaha Motor India (P) Ltd., drain that flows finally into river Hindon.The analysis of treated water indicates that the
also be explored. Unit should install CoEMS at the
A3 Industrial area, treated effluent is complying with the discharge standards prescribed by UPPCB for the
13 13.03.2018 Automobile outletof ETP or at the treated water discharge point
Noida-Dadri Road, Surajpur, District G.B. Nagar, parameter such as pH, COD, TSS except BOD which indicates that the ETP is not operated
within the premises and also be connected to the
UP. properly and requires augmentation.Hazardous waste such as used oil, used thinner,used
servers of CPCB and UPPCB. Proper log bookindicating
coolant, oil soake cotton glovesis disposed off through aTSDF namely Bharat oil & waste
total treated water discharged need to be recorded and
Management CompanyLtd Kanpur Dehat, U.P.
maintained. Unit should take measures for minimisation
of fresh water consumption by recycling the treated
water.Directions under section 5 of the E(P) Act,
1986may be issued for ensuring complaiance to the
discharged normsprescribed by UPPCB and also to
comply with the above recommendations.
1) Unit is required to make concrete flooring within the
industry and other necessary measures required for
maintainance of proper housekeeping 2) Skimming
provision at the ETP inlet should be machanized and
skimming material shouls not be done mechanically. 3)
1) Unit is involved in manufacture of kraft paper from the waste paper. 2) House keeping Display board should be provided at the entrance
is very poor. 3) The analysis reults of the treated effluent reveals that the treated effluent indicating production capacity, present production,
I before discharge of treated water into the drain is not complying to the effluent validity of consents under water Act, 1974, Air Act, 1981.
discharge norms w.r.TSS 4)The O & M of ETP is not proper and skimming of waste 4) Existing ETP is required to be upgraded to ensure
M/S Suchi Paper Mills Ltd,
14 05.04.2018 Pulp & Paper material at the inlet of ETP is done manually but not mechanically. 5)The COEMS probe is generated wastewater is treated properly before
589/2, Bisrakh Road, Vill. Chapraulla, G.B. Nagar
connected at the ETP outlet and is also connected to the CPCB server .6) The COEMS discharge.5) Efforts should be taken by the unit for
probe is connected at the ETP outlet and is also connected to the CPCB server.7) Unit reduction of water consumption by recycling of treated
obtained permission from CGWA for use of ground water resources for industrial water. 6) Proper measures should be taken that the
purposes. treated effluent before discharge into drain is complying
with the effluent discharge norms as prescribed by
UPPCB. 7) The O & M of ETP is ensured properly 8)
Directions under section 5 of the E (P) Act, 1986 may be
issued to the unit for ensuring compliance to above
recommendations in a time bound manner.
73
1) Unit is required to take adequate measures for
improvement in hosekeeping. 2) The unit should stop
discahging of treated water (but not complying with the
discharge norms) with immediate effectsinto Dhoom
Dujana irrigation canal (nallah) which is located about
0.5 km from the industry, as same is not complying with
the discharge norms. 3)The existing ETP is required to be
1) Unit is involved in manufacture of printing and writing paper from the waste paper.
augmented or upgraded to ensure proper treatment of
House keeping is not satisfactory. 2) The analysis reults of the treated effluent revealsthat
generated wastewater and also to ensure compliance to
the treated effluent is not complying to the effluent discharge norms w.r.toTSS, BOD,
the effluent discharge norms for discharge into drains. 4)
COD and about 500KLD of water is discharged into the drain which is connected to
the unit should ensure proper O&M of ETP effectively
Dhoom Dujana Irrigation canal (nallah) which is located at about 0.5 km from the
and ensure to comply with the discharge norms.Efforts
M/S Kawatra Papers (P) Ltd., industry. 3) The O& M ETP is not proper and requires qugmentationor up gradation so as
should be made by the unit for reduction of wastewater
khasra no. 606, Village to comply with the effluent discharge norms prescribed by UPPCB.4) The COEMS probe is
15 05.04.2018 Pulp & Paper generation by adopting environmentally sound
Dhoom Manikpur, G.T. Road, Dadri, Dist. GB nagar, not connected at the ETP outlet or at the discharge point of the treated
technology for proper treatment of generated effluent
UP effluent.however, it is connected to the separate lines which may not be giving correct
and for recycling of treated water within the industry
results.Moreover, the COEMS at the treated water discharge point or at the outlet of ETP
premises. 5) The existing COEMS probe is required to be
is not attached with the CC camera. 5) On the date of visit, COEMS connected to ETP was
connected only at the ETP outlet or at the discharge
in working condition but it is not connected to the CPCB server. 6) Units could not show
point of the treated effluent and a provisison of CC
any proof with regard to the permission obtained from CGWA for use of ground water
Camera also be provided towards the COEMS probe.6)
resources for industrial purposes.
Unit is required to take action for data tranfer of COEMs
to the CPCB and UPPCB servers, with immediate effects
6) A copy of the permission obtained from CGWA for use
of groundwater resources should be submitted to CPCB
and UPPCB. 7) Directions under section 5 of the E (P)
Act, 1986 be issued to the unit for ensuring compliance
to the above recommendations in a time bound manner.
Electroplating,
M/s Aar Bee Exports,
16 05.04.2018 Phosphating & NA
Plot No-155, Udyog Kendra, Greater Noida
Galvanizing
74
1) The validity of consents ontained under water Act . 1974 and Air Act, 1981, expired in
Dec, 2107.Unit applied for renenwal of consents and the same is awaited from UPPCB. 3)
Work zone area is required to be provided with proper
No authorization under Hazdous and other waste (M &TM) Rules, 2016 as amended is
ventilation. Tube well water source available within
obtained from UPPCB.However , the generated ETP sludge generated at about 3 to 4 Kg
industry premises is required to be attached with the
/day is disposed off through TSDF located at Kanpur Dehat, U.P. 4) Tubewell located
electromagnetic flow meter for assessment of daily
within the industry premises is used as water source for consumption ansd same is not
water consumption. Unit is required to obtain
attached with electromagnetic flow meter to assess the total water consumedon daily
permission from CGWB for groundwater consumption
basis. 5) GP scrap generated at about 5% of raw material is sold or auctioed at the local
for industrial activity. Unit is required to obtain
vendor namely m/s Sumit Alloys Pvt.Ltd. 6) ETP chemical dosing detail as well as process
Electroplating, authorization under Hazardous and other waste
M/s Amber Enterprises Ltd, chemicals consume in the manufacturing process is not provided and niether record
17 13.03.2018 Phosphating & (Management & Trans boundry Movement) rules,2016
Plot No-C-3,UPSIDC, Site-4, Ksana Greater Noida maintained. 7) Paint coating is done in closed enclosures.8) Work zone area is not having
Galvanizing as amended from UPPCB for handling of hazardous
proper ventilation. 8) PPEs is not provided to the workers.9) No permission is obtained
waste generated by the unit.. Characterstics of ETP
from CGWP for extracting ground water.10) no charcaterstics of ETP sludge is availble
sludge to be analysed through a laboratory approved
with the unit .11 ) ETP outlet is not attached withOCEMS 12) Unit is not complying with
under the E(P) act, 1986. OCEMs is required to be
the discharge normsprescribed by UPPCB w.r.to TSS as well as BOD as the ETP provided is
installed at the outlet of ETP and also connected with
not adequate and not operated and maintained regularly to comply with the discharge
CPCB & UPPCB servers. Directions under section5 of the
norms.13) Also, the analysis result of the ETP outlet for heavy metals w.r.to Cr (2.3mg/l
E(P) act, 1986 to be issued to the unit for ensuring
.2mg/l limit), Ni (5.8 mg/l >3mg/l limit), and Zn (14.56 mg/l. 5mg/l limit), is exceeding the
necessary improvements in a time bound manner.
limit w.r.to electoplating effluent discharge standards which indicates that the ETP is not
adequate to treat the wastewater effluent generated by the unit.
Work zone area is required to be provided with proper
ventilation. Tube well water source available within
industry premises is required to be attached with the
electromagnetic flow meter for assessment of daily
1)Work zone area is not attached with proper ventilation. 2)Tube well water souce
water consumption. Unit is required to obtain
available within industry premises is used for consumption and same is not attached with
permission from CGWB for groundwater consumption
electromagnetic flow meter for assessment of daily water consumption.3) Unit yet to
for industrial activity.PPE is required to be provided to
obtain permission from CGWB for groundwater consumption for industrial activity of the
M/s Autotech Steel Engineering (P) the workers as per norms Unit is required to obtain
Electroplating, unit. 4)ETP sludge generated is at about 3 to 3.5 kg per day is disposed off through TSDF
Ltd, authorization under Hazardous and other waste
18 13.03.2018 Phosphating & located at kanpur Dehat, U.P 5) PPs not provided to the workers.6) Nearby drain is 10 km
PIot.No. 2B/3, Ecotech-I, Extn-I, Kasna (Management & Trans boundry Movement) rules,2016
Galvanizing away (Kot escape drain that flows directly into river Hndon. 7) Unit has not obtained
Greater Noida, U.P. as amended from UPPCB for handling of hazardous
authorization under hazardous and other waste (Management & Trans boundry
waste generated by the unit.. Characterstics of ETP
Movement) Rules,2016 as amended from UPPCB for handling of hazardous waste
sludge to be analysed through a laboratory approved
generated by the unit. 8) No characterstics of ETP sludge is available with the unit.9) ETP
under the E(P) act, 1986. OCEMs is required to be
is not attached with the OCEMS.
installed at the outlet of ETP and also connected with
CPCB & UPPCB servers. Directions under section5 of the
E(P) act, 1986 to be issued to the unit for ensuring
necessary improvements in a time bound manner.
1)The unit should operate their ETP and should
1. ETP was not in Operation during visit. 2. Bypass arrangement (flexible pipeline) was
dismantled the bypass arrangement immediately. 2) The
found connected at inlet collection tank pump and pipeline going outside the unit
unit should install water meter at all the water
Bajaj Carpet Industries Ltd, premises. No efflusent was being discharged during visit. Unit representative informed
19 08.03.2018 Textile & Dyeing abstraction points and ETP outlet and maintain daily
Suthyana Noida Dadr Highway G.B. Nagar that the ETP is under modifiction how ever, no intimation is provided to RO, UPPCB office.
logbook record for the same. 3) The unit should obtain
3. Effluent was found in the collection tank however, ETP was not operational . No sample
valid consent from UPPCb under water and air act and
was taken by the joint team.
authorization under Hazardous & other waste rules.
75
1)The unit should stabilize their ETP and shall ensure
that treated effluent should meet the discharged norms.
2)The unit should install water meter at all the water
1. Unit was in operation. 2. ETP was in opeation. The unit informed that the ETP is running abstraction points/ borewells and shall maintain daily
M/S Capital dyeing works,
under trial basis as unit started operation day before yesterday. Treated water is logbook records. 3) the unit should obtain authorization
20 Plot no C-6, site C6, Surajpur, UPSIDC, Greater 08.03.2018 Textile & Dyeing
discharged into UPSIDC drain. Unit is not complying with the effluent discharge standard under Hazardous and other waste rules and dispose off
Noida
notified under E(P) Rules. However, unit informed ETP is in stabilization ETP sludge in accordance to the authorization.4)The
handpump at Devla village showed Lead higher than BIS
limit making it unfit for drinking. Jal nigam shall take
necessary action in this regard.
1)The unit should operate their ETP properly so as to
Unit informed that only tin electroplaing is done now a days and no manufacturing is
C & S Electric Ltd, Electroplating, meet the discharge norms. 2) The unit carryout
done since 5-6 months. ETP was in operation so as to treat the effluent generated during
21 Plot no B-I, site 4 Industrial area, Kasna road, 03-08-2018 Phosphating & adequacy assessment of their ETP and comply with the
electroplating process. Unit is non-complying with TSS and cyanide discharge norms. ETP
Greater Noida UP Galvanizing recommendations of the report.3) The unit should
treated effluent was collected by joint team.
dispose off the ETP sludge to TSDF facility
1)The unit should close down the manufacturing
operation.2) The unit should upgrade & augment their
ETP and shall ensure that treated effluent meets the
ETP was in operation. ETP comprise of collection tank ,clarifer, collection tank, filteration discharge norms. 3)The unit should carry out adequacy
Electroplating,
Expert Metaltech Pvt Ltd, system. Unit requires to upgrade and augment their ETP so as to meet the norms. Unit is assessment of ETP and shall comply with the
22 08.03.2018 Phosphating &
Factory 192, Udyog kendraI Greater noida (U.P.) non complying with the effluent discharge norms and posing a serious threat due to high recommendations of the adequacy report.4) The unit
Galvanizing
cyanide and high heavy metal concentration in the treated effluent. should install flow meter at borewell and maintain daily
logbook records for water consumption. 5) The unit
should dispose off ETP sludge to TSDF facility ( as pr
authorization).
1)The unit should properly operate their ETP so as to
G.T.Cargo fittings India Pvt. Ltd. Electroplating,
ETP was operational. Unit is not complying with respect to cyanide and iron discharge meet the discharge norms. 2) The unit should dispose off
23 Plot no-92, Udhog kendra, Ecotech III, Greater 08.03.2018 Phosphating &
norms. ETP sludge as per the authorization under Hazardous
Noida U.P. Galvanizing
wastes.
Ganga Polyester Ltd. . ETP was in opeation. The treated efflusent of ETP is complying with the efflusent The unit should dispose off ETP sludge to TSDF facility (
24 08.03.2018 Textile & Dyeing
H-37/38 Site C, Surajpur textiles discharge standard. as per authorization).
Plant Opeartional during visit. sample was taken from ETP outlet. Treated effluent water
M/s Garg Tube Co. Ltd. Electroplating, is reused in process,however, as per water connsent by UPPCB they have permission to
25 Vill-Chaproulla, G.T. Road,G. Noida (Galvanising 07.03.2018 Phosphating & discharge treated water in dasna drain. They confirmed about no bypass or any injection House keeping of the plant should be improved.
&Picking (G.I.Pipe)) Galvanizing of the discharge. Rice husks layer was spread over the plant premises from nearby rice
mill industry
As inustry has stopped the process of phosphating since
Goodluck Engineering, Electroplating, Industry has stopped the process of phosphating and ETP is closed since year 2012.
year 2012 (as mentioned in the water and air consent),
26 ViLL -Dhoom, Manikpur, G.T. road, Gr. Noida 08.03.2018 Phosphating & Industry is manufacturing forged & die forged finishel structural fabrication). As there is
category of the industry may be changed from red to
(Galvanising & Picking (Bright Bar & forgings)) Galvanizing no wastewater generation in the process, therefore ETP is not required in the industry.
green in the record/database.
M/S Hero Motors Ltd. (Punch Division), Electroplating, Plant was found operational. During visit senior officers were not present in the plant.
27 Vill-Achheja, G.T. Road, G. Noida (Electroplating & 07.03.2018 Phosphating & Treated water is recycled and used in gardening. Samples were collected from ETP outlet. Nil
Phosphating (Automatic Component)) Galvanizing Good house keeping.
76
Plant Opeartional during visit. sample was taken from ETP outlet. Treated water is used
M/s Honda Siel Power Product Ltd, Electroplating, for gardening, flushing no discharge from ETP to any drain. They confirmed about no Industry may expedite the process of taking renewal
28 Plot no -5, Sec41, Ecotech-1, G Noida (Phosphating 08.03.2018 Phosphating & bypass or any injection of the discharge.They do not have CGWA permission for water from Central Ground Water Authority for Usage of
(Gensets)) Galvanizing usage.They informed that they have applied for the permission from Board.Very good ground Water.
Housekeeping
Plant was found opeartional and ETP was started when we entered the plant premises.
During industrial visit it was found that ETP outlet was diluted by connecting ground
The Industry may be inspected for further confirmation,
water pipeline to the ETP, Very poor housekeeping, surface/floor was slippery and
M/s Indo Pump Electroplating, whether industry is following the norms or not?
difficult for workers to do any work. Acid fumes were observed emiting during visit.There
29 Plot no F-29-30, Site B, G. Noida (Galvanising & 08.03.2018 Phosphating & Direction under section 5of EP Act need to given as
was no proper storage of any raw material or product. Industrial products and scraping
Picking (hand Pump)) Galvanizing Industry indulged in diluting ETP outlet with grounf
were spread all over the premises as well as on the road. NOC from ground water board
water
for the ground water usage is not available. They have not conducted any ETP outlet
analysis or ground waater quality analysis.
Plant was found operational during inspection. Samples were collected from ETP outlet.
M/s Indus tubes Ltd, Electroplating,
Treated Effluent water reused in process, however as per water consent issued by UPPCB
30 Vill-Chaproulla, G.T. Road, G. Noida (Galvanising & 07.03.2018 Phosphating & Nil
they have permission to discharge treated water in dasna drain. They confirmed about no
Picking (G.I.Pipe)) Galvanizing
bypass or any injection of discharge.Housekeeping was satisfactory.
• Industry does not meet the prescribed stsndard in the discharged effluent for the
Electroplating, parameter such as total residual chlorine, total suspended solids, cyanide, nickel and
M/s Jayanita Export (P) Ltd.
31 09.03.2018 Phosphating & heavy metals. The treatment facility is not adequate and the unit violates the Flow meter for water intake and discharge
PLOT NO. A-1, EPIP, KASNA, G.NOIDA
Galvanizing environmental norms.there is no flow meter for intake of water and discharged
wastewater.
• ETP chemical addition is done manually.
Effluent collection and normalization are followed.
• Manual mixingis done
M/s J.M.V.L.P.S. Ltd., (Ex Name J.M.V. Earthing Electroplating, Manual addition is followed for chemical mixing.
• Outlet collected for testing
32 Equipment pvt. Ltd) 12.03.2018 Phosphating & Housekeepiing may be improved of flash mixing system
• Housekeeping may be improved
Plot No- J-12, Site-C, UPSIDC, GR.NOIDA Galvanizing has to be provided rather than manual mixing. Effluent
• Flash mixing system has to be provided rather than manual mixing. Effluent discharge
discharge collected.
collected.
Industry does not meet the prescribed standards for the parameters such as TSS,
Electroplating, Units carry out Zn plating of spring. Acid fugitive
M/s JBM Autotech, Ammonical Nitrogen, O&G, Zn and cyanide. The treatment facillity is not adequate and
33 09.03.2018 Phosphating & emission observed in the room.It is a small unit. Effluent
PLOT NO-J-5, SITE -C , Gr.Noida unit violates the environmentals. The industry does not provide water measuring meter
Galvanizing discharge was collected for testing of metals.
for both raw water nad effulents.
Electroplating,
M/s Material Movell India (P) Ltd,
34 09.03.2018 Phosphating & Effluent acidic, No adequate neutralization. No proper records and ETP operation was not proper.
PIot.No.G-86/1, Site-5, UPSIDC,Gr.Noida
Galvanizing
M/s Mohak Carpet Unit was closed for more than three years due to
35 09.03.2018 Textile & Dyeing NA
PLOT NO- 8, MIHILA UDYAMI PARK -II, G.NOIDA administration and financial problem.
It is galvanizing unit. ETP was in operation during the
visit. However, the treated water collection is not
Nippon Tube Ltd, Electroplating,
The treated water mixed with effluent. As unit does not have flow meter, exact water inseparable. Treated effluent was found acidic. The unit
36 Bisrakh Road, 12.03.2018 Phosphating &
measurement not possible claims zero discharge against the consent of UPPCB.
Vill- Chapraulla, Gr.Noida. Galvanizing
Consent is for discharge and channels found with
discharge evident. Waste water sample collected
Electroplating, The industry may be directed not to operate unless it
M/s R.S. Infrastructure Pvt. Ltd. PLOTNO.12/1 , Site Analysis results indicate that the unit is non complying w.r.to suspended solids (330), Zinc
37 08.03.2018 Phosphating & takes necessary action to comply with the respective
-C, SURAJPUR, Gr.Noida (14.62) and Ammonical nitrogen (114).
Galvanizing standards
77
Electroplating,
M/s Rahul lonTech Pvt. LTd, The unit may be directed not to operate unless it takes
38 08.03.2018 Phosphating & The unit is non complying w.r.to Nickel (29.31) and cyanide (0.22), Lead (1.34)
PLOT NO 143, Udyog Kendra, Gr.Noida necessary actions to meet the above parameter.
Galvanizing
M/s Sunshine Auto Industries Electroplating,
39 PLOT 08.03.2018 Phosphating & NA NA
NO.F-24, Site-B SURAJPUR, Gr.Noida Galvanizing
M/s Surya Processor Pvt. LTd ,
40 08.03.2018 Textile & Dyeing Housekeeping has scope for improvement. The unit is meeting the respective standards. No action required.
BISRAKH ROAD, Vill-CHHAPRAULA, Gr.Noida
Electroplating,
M/S V.N.M. components,
41 08.03.2018 Phosphating & NA NA
plot no-116, site B, Surajpur, Greater noida
Galvanizing
M/s Bir Horizons Pvt. Ltd. ,
42 08.03.2018 Textile & Dyeing The unit is meeting the respective standards No action required.
PLOT NO.F-79, SITE-B, Surajpur, Gr.Noida
Vimal dyeing Hite C, Results indicate that BOD are above the prescribed
43 08.03.2018 Textile & Dyeing Unit has installed ETP and same was found operational.
H-41, surajpur industrial area standards
Electroplating,
M/s Vikas Wire Industries, Results indicate that BOD, COD and Oil & Grease are
44 08.03.2018 Phosphating & Treatment was carried out in batch process. Sample was taken from stored tank.
plot no 5-37, site C, Gr. Noida above the prescribed standards.
Galvanizing
S.P.Metaltech India Pvt LTD , Electroplating,
Unit was operating pickling process in batch mode. Unit has installed ETP and same was . Unit shall be closed till ETP of adequate capacity was
45 G-82&81, site B, Industrial area,surajpur, Greater 08.03.2018 Phosphating &
found non –operational. No Sample was taken installed
Noida, G.B. Nagar201306 Galvanizing
Electroplating,
M/s Metaltech Design (P) ltd, Unit was operational and carrying outphosphating and surface treatment. Unit has Results indicate that pH is not meeting the prescribed
46 08.03.2018 Phosphating &
Plot no 7, udyog kendra, Greater Noida installed ETP and same was found operational. Sample was taken for further analysis standards.
Galvanizing
India dyeing and textiles,
Unit was operational and carrying out dyeing process. Unit has installed ETP and same Results indicate that pH, TSS, COD and BOD are not
47 F 75 site B, surajpur, Greater Noida, G.B.Nagar 08.03.2018 Textile & Dyeing
was found operational. Sample was taken for further analysis meeting the prescribed standards
(U.P.)
Electroplating,
Spack Automotive pvt Ltd. Results indicate that BOD, COD and Oil & Grease are
48 08.03.2018 Phosphating & During inspection ETP was sound operational and performing satisfactory
Kasna road, Surajpur, Greater Noida meeting the prescribed standards
Galvanizing
1. The unit is manufacturing paint with manufacturing Sheet metal capacity of 730,000
pcs yearly and was found operational at the day of visit.
Electroplating, Show cause notice may be issued for
M/S NEUMAN COMPONENTS PVT, LTD, Plot no 2. The ETP was found in operation duringinspection and liquid effluent samples were
49 09.03.2018 Phosphating & proper operation and maintenance of the
35,Sec-31, Kasna, G. noida collected from Final Outlet of ETP for analysis. As per the test report, All the parameters
Galvanizing Effluent treatment Plant.
are complying the prescribed standards except BOD & TSS
3. The unit has not installed the online continuous effluent monitoring system (OCEMS)
1. The unit is manufacturing capacity of 2400 set of Sheet Metal /day and was found
operational at the day of visit.
2. The ETP was found in operation during inspection and liquid effluent
Electroplating,
M/S RASANDIK ENGG.INDIA LTD, samples were collected from Final Outlet of ETP for analysis. As per the test report, ETP Flow meter on the Bore Well need to be replaced and
50 08.03.2018 Phosphating &
Plot no A-1/2, Surajpur , Industrial area, G. Noida final Outlet sample complying the prescribed standards. maintained.
Galvanizing
3. The unit has not installed the online continuous effluent monitoring
system (OCEMS)
4. Flow meter was not working during Inspection.
78
1. The unit is manufacturing paint with manufacturing capacity of
80,000MTA/KLA and was found operational at the day of visit.
M/S Asian Paints Ltd., 2. The ETP was found in operation during inspection and liquid effluent
51 PLOT NO-A-1, UPSIDC, Industrial Area, site 5, G. 09.03.2018 Paint & Varnishes samples were collected from Final Outlet of ETP for analysis. As per the test report, ETP
Noida, final Outlet sample complying the prescribed standards.
3. The unit has not installed the online continuous effluent monitoring
system (OCEMS)
1. The unit is manufacturing Tetra pack in 4 lines: 1200 LPH, 6000 LPH, 6000 LPH
manufacturing capacity and was found operational at the day of visit.
2. The ETP was found in operation during inspection and liquid effluent 1. Show cause notice may be issued for proper operation
M/s. Surya Fresh Food Ltd., Agro Based & Food
52 08.03.2018 samples were collected from Final Outlet of ETP. As per the test report, and maintenance of the Effluent treatment Plant.
Plot No. 14, Dadri Road, G.Noida, GB Nagar Processing
all parameters from the outlet of the ETP are complying except BOD. 2. Unit should apply for hazardous waste authorization.
3. The unit has not installed the online continuous effluent monitoring system (OCEMS)
4. Unit has not applied for hazardous waste authorization.
1. The unit is manufacturing Auto ( Oil Quenching process) with
manufacturing capacity of 9360 Tonne and was found operational at the day of visit.
M/S Graziano Trasmissioni India Pvt. 2. The ETP was found in operation during inspection and liquid effluent
Ltd., samples were collected from Final Outlet of ETP for analysis. As per the
53 08.03.2018 Automobile
PLOT NO-14, Udyog Kendra, test report, ETP final Outlet sample is complying the prescribed
GR.NOIDA standards.
3. The unit has not installed the online continuous effluent monitoring
system (OCEMS)
1. The unit is manufacturing Basmati Rice with manufacturing capacity of 434 MT/day and
was found operational at the day of visit.
2. The ETP was found in operation during inspection and liquid effluent samples were
collected from Final Outlet of ETP after RO for analysis. As per the test report, all
parameters from the outlet of the ETP except pH are complying the prescribed standards
M/S KRBL Ltd., Agro Based & Food Show cause notice may be issued for proper operation
54 09.03.2018 3. The unit has not installed the online continuous effluent monitoring system (OCEMS)
Village- Achchheja,G.T. Road Dadri, GR.NOIDA Processing and maintenance of the Effluent treatment Plant.
4. Industry having approval from Central Ground water authority.
5. Consent under section 25/26 of the Water ( Prevention and Control of Pollution ) Act
,1974 is valid for the period from 16/02/2018 to 31/12/2019
6. Consent under section 21/22 of the Air (prevention and Control of Pollution ) Act ,1981
is valid from 16/02/2018 to 31/12/2019.
1.The unit shall provide water sprinklers for the control
of dust emission during loading and unloading so as to
minimise the dust emission. 2.Unit shall provide water
sprinklers along the temporary roads inside the premises
The effluent genrated is being treated through ETP(activated sludge process) upto tertiary to avoid fugitive dust emission during the vehicle
M/s Bajaj Hindustan sugars Ltd,
55 05.03.2018 Sugar level. The treated effluent is being recycled in process and used in horticulture and movement.3.unit shall develop green belt of adequate
Sugar Unit,Kinauni, Meerut
balance effluent is stored in treated effluent holding lagoon and utilised in irrigation. width around the premises.4. unit shall carryout periodic
medical examination and to provide presonal protective
euipment to the employees and necessary
precautionary measures shall be taken to minimize
health heazards
79
1.The unit shall provide water sprinklers for the control
of dust emission during loading and unloading so as to
minimise the dust emission. 2.Unit shall provide water
sprinklers along the temporary roads inside the premises
to avoid fugitive dust emission during the vehicle
M/s Bajaj Hindustan Sugars Ltd,
56 05.03.2018 Distillery unit comes under zero liquid discharge and the condensate using for biocomposting movement.3.unit shall develop green belt of adequate
Distillary Unit,Kinauni, Meerut
width around the premises.4. unit shall carryout periodic
medical examination and to provide presonal protective
euipment to the employees and necessary
precautionary measures shall be taken to minimize
health heazards
1) The unit shall provide ESP to control fly ash. 2).Unit
shall provide water sprinklers along the temporary roads
inside the premises to avoid fugitive dust emission
during the vehicle movement.3).unit shall develop green
M/s Sardhana Papers pvt Ltd,
57 05.03.2018 Pulp & Paper Fly ash was observed in and around the industrial premises belt of adequate width around the premises. 4) unit shall
Opp. Power sub station,Meerut Road, Sardhana
carryout periodic medical examination and to provide
presonal protective euipment to the employees and
necessary precautionary measures shall be taken to
minimize health heazards
The unit shall provide water sprinklers for the control of
dust emission during the loading and unloading press
mud so as to minimize th dust emission.
Also the unit shall provide water sprinklers along the
temporary roads inside the premises to avoid fugitive
All treated water stored in lagoon were used in Beggase yard, Wet scrubber. There were
M/s Ramala Sahkari Chini Mills Ltd, dust emission during the vehicle movements.
58 07.03.2018 Sugar oil and greese screamer, bar screamer, and chlorination tank, multigrade filterand active
Ramala, Bagpat The unit shall develop green belt of adequate width
carbon filter (tertiary treatment system) were installed and in working conditions.
around the premises.
·The unit shall carryout periodic medical examination
and to provide personal protective equipment (PPE) to
the employees and necessary precautionary measures
shall be taken to minimize health hazards.
1.The unit shall provide water sprinklers for the control
of dust emission during loading and unloading press
mud so as to minimise the dust emission. 2.Unit shall
provide water sprinklers along the temporary roads
inside the premises to avoid fugitive dust emission
M/s Titwai Sugar Complex,
59 07.03.2018 Sugar Treated effluent used for irrigation purpose inside the plant as well as to nearby farmers during the vehicle movement.3.unit shall develop green
Indian Potash limited unit,Titwai, Muzaffarnagar
belt of adequate width around the premises.4. unit shall
carryout periodic medical examination and to provide
presonal protective euipment to the employees and
necessary precautionary measures shall be taken to
minimize health heazards
80
1.The unit shall provide water sprinklers for the control
of dust emission during loading and unloading press
mud so as to minimise the dust emission. 2.Unit shall
provide water sprinklers along the temporary roads
M/s Bajaj Hindustan Ltd. inside the premises to avoid fugitive dust emission
The treated effluent stored in lagoon was observed lot of algal growth and it seems that
60 Budhana, 07.03.2018 Sugar during the vehicle movement.3.unit shall develop green
the stored water is not used for any purpose.
Muzaffarnagar belt of adequate width around the premises.4. unit shall
carryout periodic medical examination and to provide
presonal protective euipment to the employees and
necessary precautionary measures shall be taken to
minimize health heazards
The OCEMS is installed and found in working condition at the time of inspection. ETP is
M/s D.S.M. Sugar
found operational and the samples was collected from the outlet of the ETP. The analysis
61 Mansurpur, Meerut 06.03.2018 Sugar
results indicate the compliance of standard and there was no discharge observed from
Road.
industry during inspection.
The OCEMS is installed and found in working condition at the time of inspection. ETP is
M/s Uttam Sugar Mills, found operational and the samples was collected from the outlet of the ETP. The analysis
62 08.03.2018 Sugar
Khaikheri,Muzaffarnagar. results indicate the compliance of standard and there was no discharge observed from
industry during inspection.
The OCEMS is installed and found in working condition at the time of inspection. ETP is
M/s Triveni Engg. Industries Ltd. found operational and the samples was collected from the outlet of the ETP. The analysis
63 06.03.2018 Sugar
Khatauli, Muzaffarnagar. results indicate the compliance of standard and there was no discharge observed from
industry during inspection.
The industry is inspected on March 08, 2018 by the officials of CPCB, UPPCB and UPJN.
M/s Triveni Engg. Industries Ltd.(Alco)
64 08.03.2018 Distillery The spent wash is utilized for composting. MEE is found operational. There was no
Bilaspur, Jolly Road, Muzaffarnagar.
discharge observed from industry during inspection.
The industry is inspected on March 06, 2018 by the officials of CPCB, UPPCB and UPJN.
M/s Sir Shadi Lal Distillery & Chemical Works,
65 03-06-2018 Distillery The spent wash is utilized for composting. MEE is found operational. There was no
Mansoorpur
discharge observed from industry during inspection.
The OCEMS is installed and found in working condition at the time of inspection. ETP is
M/s I.P.L. Sugar Unit
found operational and the samples was collected from the outlet of the ETP. The analysis
66 Rohana kalan, 08.03.2018 Sugar
results indicate the compliance of standard for disposal on land and there was no
Muzaffarnagar.
discharge observed from industry during inspection.
No electromagnetic flow meters were installed; however ultrasonic flow meters were
installed and were found operational.
M/S Garg Duplex,
67 16.04.2018 Pulp & Paper No record was being maintained for disposal of coarse screen reject (plastic &
Bhopa road, Muzaffarnagar, U.P
metallic) after the pulper section and also in the hill screen of the ETP inlet.
Housekeeping was very poor in the entire processing area of paper and pulp unit.
No electromagnetic flow meters were installed; however ultrasonic flow meters were
installed and were found operational.
Ground water sample collected near M/s Silvertone (Unit I & II) and M/s Garg Duplex
M/s Silvertone Paper Ltd. (unit I)
68 16.04.2018 Pulp & Paper (P) Ltd., were not complying w.r.t Sulphate.
Bhopa Road, Muzaffarnagar
No record was being maintained for disposal of coarse screen reject (plastic &
metallic) after the pulper section and also in the hill screen of the ETP inlet.
Housekeeping was very poor in the entire processing area of paper and pulp unit.
81
i. The equipments/facilities within the premises were found rusted.
III. The inspecting team has observed pile of plastic waste (wet condition) were found
spread within the premises over an area of about 50m x 30 m. The plastic waste seems to
have generated from the hole screen separator (after pulper section) of the pulp and
M/s Shalimar Paper (p) Ltd.,
paper industry (Kraft).
69 8th KM stone Jansath Road,Muzafarnagar, 12.04.2018 Pulp & Paper
IV. Ground water sample was collected from hand pump in front of the premises within
U.P.251001
500 m radius for the parameters Fluoride, Sulphate, Cd, Cu, Pb, Ni, Zn, Hg and Oil &
Grease.
Note: Analysis report of the ground water sample shall be forwarded as and when
received from Fresh water lab and Instrumentation lab.
Waste water from primary clarifier is taken to the
No electromagnetic flow meters were installed; however ultrasonic flow meters were
recycle tank and reused for plant through spray filter.
installed and were found operational.
The same needs to checked with concerned SPCB for
Cement Concrete pits (10 m x 10 m) were found adjacent to the drain where treated
authorization, since “Effluent "Discharge" shall mean the
waste water effluent is discharged. It was informed by the unit that local people have
M/S Bindalas Ltd, (Unit-1) effluent leaving the outlet of the final wastewater
70 12.04.2018 Pulp & Paper made those pits in order to gather settled pulp, if any to be reused in making cardboards.
Bhopa Road, Muzaffarnagar treatment stage and will include any volumes applied on
Photographs enclosed for reference please.
land within the mill premises or any other mill-owned
No record was being maintained for disposal of coarse screen reject (plastic & metallic)
lands. Such application on land shall not be drawn from
after the pulper section.
any other point before the outlet of the final wastewater
Housekeeping was very poor in the entire processing area of paper and pulp unit
treatment stage”
No electromagnetic flow meters were installed; however ultrasonic flow meters were
installed and were found operational.
Cement Concrete pits (10 m x 10 m) were found adjacent to the drain where treated
waste water effluent is discharged. It was informed by the unit that local people have
M/S Bindalas Ltd, (Unit-2)
71 12.04.2018 Pulp & Paper made those pits in order to gather settled pulp, if any to be reused in making cardboards.
Bhopa road, Muzaffarnagar
Photographs enclosed for reference please.
No record was being maintained for disposal of coarse screen reject (plastic &
metallic) after the pulper section and also in the hill screen of the ETP inlet.
Housekeeping was very poor in the entire processing area of paper and pulp unit.
No electromagnetic flow meters were installed; however ultrasonic flow meters were
installed and were found operational.
M/S Shakumbari Pulp & Paper
72 16.04.2018 Pulp & Paper No record was being maintained for disposal of coarse screen reject (plastic & metallic)
Bhopa Road
after the pulper section and also in the hill screen of the ETP inlet.
Housekeeping was very poor in the entire processing area of paper and pulp unit.
Analysis result s indicate compliance of standard for disposal.However, the value of BOD
M/s. N.S. Papers Ltd. (Unit-1), Industry should improve cleanliness in the premises and
73 09.04.2018 Pulp & Paper is slightly high.The treated effluent is discharged into a small drain. Common ETP for Unit
Jansath Road, Muzaffar Nagar developed greeen belt.
1 & 3. Applied for NOC from CGWA.
Analysis result s indicate compliance of standard for disposal.However, the value of BOD
M/s. N.S. Papers Ltd. (Unit-3), Industry should improve cleanliness in the premises and
74 09.04.2018 Pulp & Paper is slightly high.The treated effluent is discharged into a small drain Applied for NOC from
Jansath Road, Muzaffar Nagar developed greeen belt.
CGWA.
The OCEMs is installed and found in working condition at the time of inspection. ETP is
M/S Mahalaxmi Craft & Tissues found operational and the samples were collected from ETP outlet.The analaysis results Industry should improve cleanliness in the premises and
75 09.04.2018 Pulp & Paper
Bhopa Road, 9th Km, Jansath Road indicate the compliance of standard for disposal. The treated effluent is being discharged developed greeen belt.
into a small drain
82
The OCEMs is installed and found in working condition at the time of inspection. ETP is
found operational and the samples were collected from ETP outlet.The analaysis results
M/S Aggarwal Duplex & Board Mills Ltd. indicate the compliance of standard for disposal. Different reading of flow meters was Industry should improve cleanliness in the premises and
76 09.04.2018 Pulp & Paper
Bhopa Road observed at the outlet of ETP, V notch, displayed at OCEMS and flow meter reading. developed greeen belt and calibration of flow meters
Therefore flow meter needs to be calibrated.The treated effluent is being into a small
drain.
The OCEMs is installed and found in working condition at the time of inspection. ETP is
found operational and the samples were collected from ETP outlet.The analaysis results Industry should improve cleanliness in the premises and
M/S Tirupati Balaji Fibers Ltd. indicate the compliance of standard for disposal. The treated effluent is being discharged developed greeen belt. Industry should utilise the
77 11.04.2018 Pulp & Paper
Bhopa Road into a small drain. As per the consent issued by the UPPCB, the treated water has to be treated effluent for recycling in the process of for
used for re-cycling in the process or irrigation purpose only. But the industry is irrigation purpose.
discharging the treated effluent into small drain.
M/S Meenu Papers (P) Ltd., Analysis result s indicate compliance of standard for disposal.The treated effluent is Industry should improve cleanliness in the premises and
78 11.04.2018 Pulp & Paper
9.5 Km, Bhopa Road discharged into a small drain developed greeen belt.
M/S Tehri Pulp & Papers Ltd. (Unit-I), Renewed consents under air and water act may be
79 12.04.2018 Pulp & Paper The consent under air and water act has been expired in December,2017.
9th Km Stone, Bhopa Road obtained from State Board
M/S Tehri Pulp & Papers Ltd. (Unit 2), Renewed consents under air and water act may be
80 12.04.2018 Pulp & Paper The consent under air and water act has been expired in December,2017.
9th Km Stone, Bhopa Road obtained from State Board
M/S Suyash Craft & Papers Ltd. Authorization under Hazardous and Other Waste
81 13.04.2018 Pulp & Paper Analysis results entered
Village- Velhana, Meerut Roadf, Muzaffarnagar (M&TM) Rules, 2016 may be obtained from State Board.
M/S Shri Bhageshwari Paper Mills (P) Ltd., After analysis of testing report of waste water sample from effluent treatment plant &
82 9 th Km Stone (Unit-1), Bhopa Road, 12.04.2018 Pulp & Paper ground water sample from bore well, it has been observed that value of TSS & BOD ETP may be operated on optimum capacity.
Muzaffarnagar exceeded the prescribed limit of standards.
M/S Shri Bhageshwari Paper Mills (P) Ltd.,
Repairing of broken water meter or else replace it with
83 9 th Km Stone (Unit-2), Bhopa Road, 12.04.2018 Others Water meter was broken at the time of inspection. ETP capacity is inadequate.
new one.
Muzaffarnagar
The renewed Consents under air and water act may be
M/s Sidhbali Papers mills Ltd,), Consent has been expired in December, 2017 and its validity put on hold by the UPPCB
84 13.04.2018 Pulp & Paper obtained from State Board and production capacity may
45-B, new mandi, Muzaffarnagar due to NGT case
be increased as per renewed consents.
83
1. There was no display of the name of the industry at the entrance. 2. The unit was found
operational at the time of the inspection. ETP was also found operational. 3. The industry
uses wastepaper for manufacture of Kraft Paper. Sludge generated is used for
manufacture of low garde paper as per information provided by the plant management.
4. ETP comprises Equalization tank, Hill Screen, Primary clarifier, Aeration Tank,
Secondary clarifier, Collection pit and Spray filter. 5. The industry has obtained Consents
under Water ACt 1974 and Air Act 1981 which are valid upto 31.12.2019. 6. There was no
qualified people overseeing the operation and maintenance of ETP. The lack of qualified
manpower caused difficulty in getting relevent information on site during inspection.
Important information such as wastewater generation could not be gathered or
satisfactory informed at the time of inspection. Log sheets were not properly maintained.
However, the industry representative sent the informatiob later on. 7. The industry has
obtained authorization from SPCB under Hazardous and Other Wastes (management and
transboundary Movement) Rules 2016 and the same is valid for five years from
29.11.2017. 8. The industry has applied for NOC from CQWA for abstraction of ground
M/s Siddheshwari Ind. Pvt. Ltd.,
85 08.03.2018 Pulp & Paper water. 9. OCEMS was found installed at outlet of ETP and it was found functional during See observations and lab results
Jansath Road,
the inspection. It was also informed that the OCEMS has been connected to the CPCB
server for online transfer of data. 10. Flow meter has been installed on all 4 bore wells to
measure water consumption. However, industry could not provide satisfactory
information on water consumption at the time of inspection. Though, the document was
sent by the industry later on. 11. Analysis report of effluent samples and groundwater
samples, collected during the inspection is awaited. 12. relevent documents provided by
the industry are attached. 13. Inlet water was obsvered very clean - not the characteristic
of paper industry which raised possibility of altered manufacturing process ie.possible
dilution. Also, MLSS of Aeration tank was visibly high over 80% of the volume of the
sample settled, when taken in a 1000 ml measuring cylinder. 14. Treated effluent is
discharged into Dhadera drain jut outside the pant premises. As per information, it
originates before Makhiyali village. It was also informed that another drain merges with it
near Allur Meat factory close to the Dhandera village. The Dhandera drain receives
discharge from various industries Jansath and Bhopa road. The Dhandera drain discharges
in West Kali which finally merges into River Hindon.
84
1. The plant was under shut down upon arrival of the team, reportedly due to problem in
process i.e. crack in drum belt in paper mill. It was informed that the plant was closed at
approximately 8.30 am on that day. subsequently, the plant was made operational. 2. To
collect representative samples for analysis, the inspection team had to return to the unit
after 3 h of initial inspection, when the ETP was operational. 3. the industry uses
wastepaper as raw material for manufacture of duplex board. 4. As per information
provided, production capacity of unit was enhanced from 30 TPD to 60 TPD in 2013. 5. As
per adequacy report prepared in sept, 2017 by the Central Pulp and Paper Research
Institute, Saharanpur, there is proposed production capacity explnsion to 100 TPD. 6. ETP
comprises of Equalization tank, Sedi Cell, Tube Settler, Aeration tank, Secondary clarifier,
Tube settler, Multigrade filter. 7. The industry has obtained Consent under Water ACt,
1974 and Air Act, 1981 which are valid upto 31.12.2018. 8. Consent for authorization from
SPCB under hazardous and other wastes Rules 2016 is not available. Copy of application
M/s K.K. Duplex & paper mill Pvt.
86 08.03.2018 Pulp & Paper has not been provided. 9. there are 2 borewells within the premises, Industry has applied Nil
Ltd., Jansath Road, Muzaffarnagar
on 25.10.2017 for permission for groundwater abstraction from CGWA. However, till date
NOC has not been granted to the industry. 10. OCEMS was found installed at outlet of
ETP and was found functional during the inspection. It was also informed that the OCEMS
has been connected to the CPCB server for online transfer of data. Flow meter has been
installed on both the borewells to measure water consumption. 12. Analysis report of
effluent samples and ground water sampes collected during the inspection is awaited. 13.
Relevent documents provided by the industry such as Consent papers, ETP flow sheet etc
are attached. 14. There were no qualofied people overseeing the operation and
maintenance of ETP. The lack of qualified manpower caused difficulty in getting relevent
information on the site during inspection. Important such as wastewater generation could
not be gathered at the time of inspection. Log sheets were not properly maintained.
However, the industry representative sent some of the information later. 15. Treated
effluent is discharged into Dhandera drain outside the plant premises.
85
1. The unit was found operational at the time of the inspection. ETP was also found
operational. The industry uses wastepaper for manufacture of Kraft Paper. 2. ETP
comprises Equalization Tank, Hill Screen , primary clarifier, Aeration, Secondary clarifier,
MGF (Multi grade filter) and ACF (Activated Carbon Filter). 3. The industry has applied
online for Consent under Water Act, 1974 and Air Act 1981 on 4-2-2018. It was
understood from discussions with the accompanying SPCB official that the delay in
providing consent is due to online system introduced recently in the state and there is no
fault of the industry. State is expected to issue NOC soon. 4. The industry has obtained
authorisation from SPCB under Hazardous and other Wastes (Management and
Transboundary Movement) rules 2016 and te same valid for 5 years from 4-8-2017. 5. As
an initiative towards waste management, the industry has an agreement with M/S Bharat
M/s Silver Tone Pulp & Paper, Oil and Waste management Ltd. Specified waste materials generated by the unit, is
87 08.03.2018 Pulp & Paper Nil
9th Km Stone, Bhopa Road, Muzaffarnagar. provided to Bharat oil and Waste Management Ltd. for incineration. 6. Unit has applied
for NOC for groundwater abstraction from CGWA. 7. OCEMS was found installed at outlet
of ETP and it was found functional during the inspection. it was also informaed that the
OCEMS has been connected to CPCB server for the online transfer of data. 8. Flowmeter
has been installed on all three bore wells to measure water consumption. 9. Analysis
report of effluent samples and groundwater samples, collected during the inspection, is
awaited. 10. Industry has provided the relevent documents such as copy of application for
consent under Air and Water ACt, ETP flow sheet, logsheet etc. 11. There was no display
of the name of the industry in its main entrance. 12. Condition of housekeeping was
satisfactory. A qualified professional having M.Sc degree was found employed to oversee
the operations and maintenance of ETP. 13. The treated effluent is discharged into
Dhandera drain which meets river Kali west approximately 20 k from plant premises.
86
1. M/s Bindals paper mills Ltd is a Wood, Agro and Wastepaper based writing printing
paper industry with installed capacity of 300 TPD. 2. The unit process and its ETP were
operational at the time of inspection. 3. The unit ETP comprises of Equalization tank /82
no.s 256 cubic m each); MIST cooling system, Aeration tank with MIST cooler, surface
aerator /(7500 cubic m) and air blowers; Secondary clarifier; physio-chemical treatment
using flocculation and coagulation (DAF 300 cubic m); tertiary treatment by dual media 1. The outlet conduit systtem after tertiary treatment
filters (572 cubic m). 4. At the time of visit treated effluent after tertiary treatment was faciity of ETP shall have to be provided in such a way
processed in RO plant which has newly been installed. The RO permeate was recycled and that appropriate positioning of OCEMS and flowmeter
reutilized in the manufacturing process. 5. the unit ETP inlet and outlet points were ensures mesurement of the actual amount of treated
provided with flow meters. V-notch was installed at the ETP outlet. There was however, effluent being recycled for use in rocess or in case being
not any scientific facility avaiable for quantification of actual treated wastewater discharged after tertiary treatment into the nearby
discharge from ETP being recycled for utilization in the process. 6. The OCEMS installed at drain. 2. the unit shall provide jet aerators for proper air
the final ETP outlet was having its sensor equipment fitted and imersed in the stagnant mixing in the quard pond. 3. The unit has installed RO
water filled in topside open hemi-cylindrical plastic container, thus having no provision plant to reuse the treated effluent in manufacturing
M/S Bindal Papers Ltd.
for direct contact with any possible flow of the treated trade effluent being discharged process and has provision for discharging the effluent
88 Bhopa Road, 08.03.2018 Others
after ertiary treatment through the ETP outlet in to the DHandera Nala which passes after tertiary treatment through final outlet. In case the
Muzaffarnagar
immedicately near the industry premises. 7. A very small discharge (0.08 cubic m/h) unit discharges effluent after tertiary treatment through
through the EtP outlet was recorded from V-notch due to RO valve leakage.8. he unit is final outlet. In case the unit discharges effluent after
operating without valid consent to operate (CTO) under Sit Act and Water Act having tertiary treatment into the drain, the performance of an
validity expired on 31.12.2017. The unit , however, has applied to UPPCB for renewal of ETP is too poor to comply its treated effluent quality
the CTO on 04.02.2018 and provided application copy of the same. 9. The unit has within stipulated wastewater discharge norms w.r.t. pH
authorization under hazardous waste management rules haing validity upto 17-1-2022. 6.25 (against the norms of 7-8.5); BOD 38 mg/L (agaisnt
10. The unit has applied for renewal of NOC from CGWA on 27.9.2017 as its validity had the norma of 30 mg/L); TSS 89 mg/L (against the norms
expired on 04.11.2013. 11. the unit meets its freshwater consumption (31 cubic m/T of 50 mg/L). the unit is therefore recommended to
paper) through ground water abstraction from four bore wells which are equipped with improve the performance of the functioning of ETP.
electromagnetic flow meters. In the month of Feb 2018 the unit consumed 6493.42 KLD
of fresh water. 12. the water holding pond (3938 cubic m) lying near aeration tank has got
adequacy clearance from IIT for its use as emergency guard pond to ensure the storage of
wet washing effluent in case of any breakdown. 13. The unit is practicing consortium of
mix culture (aerobic and anaerobic) in the pond.
M/s. Arihant Pulp & Papers Ltd.,
89 08.03.2018 Pulp & Paper CLOSED CLOSED
Jansath Road, Muzaffar Nagar.
87
1. M/s Disha Industries Pvt. Ltd. Is a wastepaper based Kraft paper industry with installed
capacity of 200 TPD. 2. The unit process and its ETP were operational at the time of
inspection. 3. The outlet channel to tertiary treatment from secondary clarifier was
completely dry. 4. The unit uses wastewater after treatment in primary clarifier for
pulping process. 5. At ETP outlet point both flow meter and V-notch were installed. 6.
Effluent after tertiary treatment has an alternative to be discharged into drain (Sikhreda
Nala) but the entire quantity of effluent after teriary treatment was pumped out for its
use in the manufacturing process at the time of visit. 7. The amount of treated water
being recycled for use in the process after tertiary treatment could not be quantified as
the flow meter was not properly working. OCEMS didnt provide the satisfactory results
especially for flow measurement as the value recorded were merely 0.05 meter cube/h
1. On the supply line carrying treated effluent for
only. V-notch gear facility installed outlet channel works only when discharge of treated
process use, the drain-off valve meant for occasional
effluent is allowed into the nearby drain through an overflow outlet channel. 8. For
disposal of small mount of tertiary treated effluent used
sample collection purpose and for measurement of the flow, treated effluent was allowed
in Filter ottle wash oof after cleaning of Filter bottles
to pass on for a while through overflow channel into sikhreda Nala. At this time only the
into the overflow outside the V-notch gear should either
outlet channel from secondary clarifier carried the wastewater which was pumped into
have to be closed permanently or made to open into the
M/s Disha Industries ltd., the dual media filter for tertiary treatment. 9.Wastewater flow measurement from
90 08.03.2018 Pulp & Paper collection tank to ensure proper water management. 2.
9th Km, Jolly Road, Vill- Sikhrera, Muzaffarnagar OCEMS, Mass flowmeter and V-notch at the ETP outlet when treated effluent was
The placement of OCEMS probe, Flow meter sensor and
allowed to discharge into the drain doesnt show much difference in the observed values,
V-notch gear should have to be properly placed at the
thus indicating the proper functioning of the flow measurement devices at this time
final outlet channel to ensure maximum scientific
irreoective of the previous case when all the treated effluent was recycled for use in the
accuracy in measurement of the actual representative
process. The reason for not having in the OCEMS record (as determined from the
characteristics of the wastewater quality including the
wastewater flow record), satisfactory information on the actual amount of discharge of
flow.
treated effluent into the drain apart from using in the process couldnt be justified from
the information procided by the unit. 10. The unit has valid consent under Air ACt and
water Act validity upto 31.12.18. 11. NOC from CGWA for groundwater abstraction is
valid upto 27.9.2019. 12. Abstraction of groundwater is made from 2 bore wells both of
whichare provided with flow meters. The present flow of Bore well no. 2 was 124/284
cubic meter/h of the total water abstraction record of 1270683 cubic meter and the flow
rate of borewell no. 1 was 76.2 cubic meter/h out of the total water abstraction record of
131512 cubic meter. The treated effluent quality of ETP is complying with sti[ulated
wastewater discharge norms w.r.t. pH 8.03 (against norms of 7-8.5). COD 120 mg/L
(against norms of 250 mg/L), BOD 15 mg/L (against the norms of 30 mg/L) and TSS 45
mg/L (against the norms of 50 mg/L)
1. The unit is Paper mill with an installed capacity of 100 MT/day using waste paper. 2.
During the visit, unit was shutdown for maintenance. 3. The unit has a valid consent of Air
It is suggested to keep housekeeping in the premises 2.
and Water and valid upto 31.12.2018. Copies are enclosed. 4. Unit has obtained the NOC
M/s. Galaxy Papers Pvt. ltd., The unit should obtain the authorization under
for extended capacity from 15 MT/day to 100 MT/Day vide letter no:H14868/C-3/NOC-
91 9.4 Km Jolly Road, Vill- Dhandhara, Muzaffarnagar 15.03.2018 Pulp & Paper Hazadous and Waste, 2016. 3.Unit should obtain CTO for
506/Muzaffarnagar/17. But the unit has not applied for the CTO for extended capacity. 5.
(Under maintanence during visit) extended capacity. 4. Unit should connect with CPCB for
Unit has not obtained any membership certificate from any TSDF. 6. Unit has 2 boilers of
data submission of flow.
4 TPH and 12 TPH. 6. Unit has installed web camera and flow meter but ut is not
connected with CPCB.
M/s. Taj Papers Pvt. Ltd.,
92 Jolly Road, 15.03.2018 Pulp & Paper
Muzaffarnagar
88
1. The sample collected from the ETP outlet has been given for analysis. 2. The unit is
1. It is suggested to keep good housekeeping in the
Paper mill with an installed capacity of 100 MT/day using waste paper. 3. During the visit
premises 2. The unit should obtain the authorization
it was found operational. 4. The unit has a valid consent of Air and Water and valid upto
M/s. Shaktl Kraft & Tissues Pvt. Ltd., under Hazardous and Waste, 2016. 3. Electromagnetic
93 15.03.2018 Pulp & Paper 31.12.18. 5. Unit has obtained a membership certificate from Bharat Oil and Waste
9th Km, Jansath Road,Muzaffarnagar flow meter installed at discharge line measures only flow
management Ltd. 6. Unit has a boiler of 6TPH using baggase and wood as fuel. 7. Unit has
rate and hence suggested to install flow meter which
installed OCEM system at ETP outlet for pH, BOD, COD, TSS and flow. It is also connected
can measure cumulative flow.
with CPCB.
1. The sample collected from the ETP outlet has been given for analysis.2. The unit is
Paper mill with an installed capacity of 50 MT/day using waste paper and got NOC from
1. It is suggested to keep good housekeeping in the
UP Pollution control board for the capacity of 150MT/day. They have also applied for the
premises 2. Electromagnetic flow meter installed at
M/s. Aristo Craft Papers Pvt ltd, renewal of CTO for expansion.3. During the visit it was found operational. 4. The unit has
94 15.03.2018 Pulp & Paper discharge line measures only flow rate and hence
7 Km, Meerut Road, MuzaffarNagar a valid consent of capacity 50MT/day for Water and Air valid up to 31.12.18. 5. Unit has
suggested to install flow meter which can measure
obtained a membership certificate from Bharat Oil and Waste Management Ltd. 6. Unit
cumulative flow.
has a boiler of 12 TPH using baggase as fuel. 7.Unit has installed OCEM system at ETP
outlet for pH, BOD, COD,TSS and flow. It is also connected with CPCB.
M/s. Orient Board & Papers Pvt. Ltd.,
95 15.03.2018 Pulp & Paper Closed
Jansath Road, Muzaffarnagar
1. The sample collected from the ETP outlet has been given for analysis.2. The unit is 1. It is suggested to keep good housekeeping in the
pharmaceutical unit with an installed capacity of 50 MT/day.3. During the visit it was premises 2. The unit should obtain the authorization
M/s Magma Industries Ltd.,
found operational. 4. The unit has a valid consent for Water and Air valid up to 31.12.19. under Hazardous and Waste, 2016. 3. Electromagnetic
96 C-27 UPSIDC Industrial Area, Begrajpur, 15.03.2018 Pharmaceutical
5. Unit has obtained a membership certificate from M/s Ramky Enviro. 6. Unit has 2 boiler flow meter installed at discharge line measures only flow
Muzaffarnagar
of 3 TPH and 5 TPH. 7. Oil and grease was observed around the ETP 8. No electromagnetic rate and hence suggested to install flow meter which
flow mete installed for water consumption and waste water generation can measure cumulative flow.
M/s. Ravi Organics Ltd.,
97 Begrajpur, 13.04.2018 Chemical CLOSED CLOSED
Muzaffarnagar
M/s. Gulshan Polyoles Ltd., During inspection, Unit was found operational.
98 Jansath Road, Muzaffarnagar 13.04.2018 Chemical Algae/scum was also observed in clarifier. NIL
Sample was collected from discharge outlet and results are complying prescribed norms.
M/s. Al-Noor Exports,
During inspection, Unit was found operational
99 Jansath Road, 12.04.2018 Sloughter House NIL
Sample was collected from discharge outlet and results are complying prescribed norms
Muzaffarnagar
During inspection, Unit was found operational
M/s Parijat Paper Mill, Bhopa Road, Unit representative informed that Gobar (Cow dung) is being used for maintaining MLSS.
100 13.04.2018 Pulp & Paper NIL
Muzaffarnagar Sample was collected from outlet of tertiary system and results are not complying
prescribed norms.
During inspection, Unit was found non –operational but some processed hides were
M/s. H.J. Tannery, found hanging inside premised.
9th Km, Jansath Road, ETP was non functional but discharge outlet was not dry which indicate bypass of
101 13.04.2018 Tannery NIL
Muzaffarnagar effluent.
Ground water Sample was collected from tube well inside tannery and results are
complying prescribed norms.
89
The representative of unit has reported that unit was operating ZLD system and using
treated effluent in process.
During inspection, Unit was found operational
M/s Nikita Papers P.Ltd.,
102 12.04.2018 Pulp & Paper Sample was collected from outlet of tertiary system and results are complying prescribed NIL
C-10, Ind.Estate, Panipat road, Shamli
norms.
Major issue found in unit was sludge disposal as it was openly dumped in back side of mill
premises.
The representative of unit has reported that unit was operating ZLD system and using
treated effluent in process.
During inspection, Unit was found operational where as ETPs units; Primary clarifier found
non- operational and whereas aeration basin was functioning and re-circulating water
from same tank.
No overflow was observed in secondary clarifier.
It is recommended that unit shall made primary and
M/s.Maruti Papers Pvt.Ltd., Probe of OCMS were immersed in final collecting tank and algae/scum was also observed
103 12.04.2018 Pulp & Paper secondary clarifier fully operational and lift treated
Village Sikka, Shamli in tank .
effluent from final collecting tank.
Sample was collected from outlet of tertiary system (MGF) and results are complying
prescribed norms.
As stated earlier, primary clarifier was non operational, no overflow was observed in
secondary clarifier .So, there is possibility of bypassing of effluent from sedi cell and unit
was not achieving
ZLD.
M/S Upper Doab Sugar Mill The online monitoring device showing the results of pH,
104 06.04.2018 Sugar The unit is complying with the effluent standards.
Shamli TSS, BOD & COD should be rectified immediately
Sludge drying bed leaks need to be repaired immediately
M/s Bajaj Hindustan Ltd.
105 07.04.2018 Sugar The unit found complying with the effluent standards. . Filtered water of sludge drying bed observed in storm
Thanabhawan, Muzaffarnagar
water drain through it was found blocked
Shamli distillery & Chemical works , ZLD unit. No violation observed regrading treatment and
106 06.04.2018 Distillery NIL
Shamli management of effluent.
90
There are 06 Nos of coal based units (4 X 210 MW and 2 X 490 MW ) and 829 MW Gas
based power plant and 5 MW solar power plant is installed at NTPC Dadri. The provision
of effluent discharge is through drains linked to Effluent Quality Monitoring Station – 1
(EQMS-1) and Effluent Quality Monitoring Station 2 (EQMS-2).
EQMS-1: coal based units (4 X 210 MW), cooling tower blow down effluent after
treatment in Neutralization Pit is conveyed in EQMS 1 drain and finally discharged to
Hasanpur drain which
ultimately meets to Hindon. It is informed by NTPC that scheme is under implementation
to complete reuse of treated effluent inside plant premises.
For St-2 Coal based and Gas plant units, all effluent including cooling water blow down &
Water meter at Borewell need to be installed log book
M/s NTPC Ltd, boiler blow down is treated in ETP with capacity of 450 m3 /hr and after treatment
Thermal Power need to be maintained.
107 Dadri, 05.04.2018 effluent is reused as service water in bottom ash disposal system, fugitive dust control in
Plant The Stage 1 effluent should be treated in ETP before
Gauthambuddh nagar Coal Handling area, Ash Handling Area and Ash Mound (ash storage) area and gardening
discharged to the Hasanpur Drain.
activities.
During Inspection no significant flow of treated effluent was observed in EQMS 2 drain,
hence Online Monitoring data was also not found operational .The Unit Informed that
major quantity of industrial effluent is being recycled and reused after treatment.
Cooling tower and Boiler Blow down was not found discharged during inspection as it was
informed that boiler blow down is being done on requirement basis which is depends on
boiler water quality and cooling tower blow down is done after certain period of interval .
Free chloride was tested by adding 05 drops of reagent & no chlorine was deleted, as
Chlorination was also not being done at the time of inspection.
Water meter at borewell not installed and no Log book for Bore well water is maintained.
M/s Cooperative company Ltd have two sections i) distillery &ii) Bottling esections , CPCB
vide letter dated 15/01/2018 has enquired regd these two sections (i) Distillery section:-
M/s Co-operative Co. Ltd.,
Found closed due to its own reasons since 1/7/2017 & 5/4 /2018 are enclose regaqrding Bottling plant should not be operated without obtaining
108 Tapri, Saharanpur (Distillery closed, Botteling In 09.04.2018 Distillery
closure of the distillery (ii) Bottling plant :- Bottling of liquor was found operational for consent from UPPCB
Operation)
which consent was granted from UPPCB and was valid upto 2016 further unit has applied
for consent on 5/4/2018 & operating without consent.
No sample was colleced as unit was closed since 22/4/2017 till date due to non
M/S U.P Coperative Sugar Factories Fedreation Ltd.
109 09.04.2018 Distillery compliance of ZLD . Copy of letter daed 9.4.2018 of Assist Commissioner , U.P Excise To comply with action plan for achieving ZLD
Nanawta Distillery Unit , Nanauta , Saharanpur
enclosed regd closure of unit
Bajaj Hindustan Ltd. Distillary Unit
110 10.04.2018 Distillery Nil Sludge drying bed leaks need to be repaired immediately
Gangnoli
91
1. Inlet has V-notch or no flow meter. Therefore flow
meter should be installed. 2. Oil & grease tank
should be installed. 3. NOC from CGWA under process.
4. Authorization for hazard waste should be taken from
UPPCB. 5. Reuse of lagoon water was done in mode of
irrigation to the field behind the industrial premises. 6.
Due to wall leakage from the spray pond water was
discharged to outside of the premises, which should be
The Kisan Sahakari Chini Mill, Nanouta,
111 11-04-2018 Sugar Lab analysis result of samples (awaited) sealed permanently. 7. The inlet wall should build so
sahranpur UP
that during the excess discharge the effluent should not
divert its path to the industrial premises. 8. There is a
Nalla which is from the industries diverted from inlet
which is already closed. But from the boundary wall it
should sealed properly. So that there will be no
discharge to Bhaneda Nalla which is connected to Krishni
Nadi (2.5 Km away from Bhaneda Nalla. Krishni Nadi
meets Hindon.
1. Inlet has no v-notch or flow meter. Thereefor should
be installed. 2. Outlet has no flow meter and v-notch
was not installed properly at the time of visit. There was
leakage at v-notch. Therefore flow meter should be
112 Daya Sugar Gagalheri, Saharanpur, U.P 10-04-2018 Sugar Lab analysis result of samples (awaited) installed. 3. Flow meter should be installed at bore wells
too. 4. OCEMS should be installed. 5. Oil & Grease tank
should be installed. 6. NOC from CGWA should take.7.
reuse of lagoon water should be done in mode of
irrigation or process use.
1. Inlet has no flow meter. Therefore flow meter should
be installed before equalization tank at inlet. 2. Reuse of
lagoon water should be done in mode of irrigation or
process use.’ 3. There is a Nalla (Deoband Nalla) crossing
side by the ETP premises. An outlet linked to that Nalla
Triveni Engg. & Industires Ltd.,
113 10-04-2018 Sugar Lab analysis result of samples (awaited) was blocked temporarily at the time of inspection. And
Deoband, saharanpur, U.P
untreated water was pumped out from that place to ETP
equilizatiion chamber. But there is a possibility of
discharging of untreated water to Deoband Nalla.
Therefore, it should be closed permanently, which is
temporarily connected to Nalla.
1. Inlet has v-notch but no flow meter. Therefore flow
meter should be installed. 2. Oil & grease tank
should be installed before equalization tank. 3. Sewage
drain (without any STP) is situated inside the ETP
Bajaj Hindustan Sugar Ltd., Gangoli Saharanpur, premises which make a chance of discharge of untreated
114 10-04-2018 Sugar Lab analysis result of samples (awaited)
U.P water which finally met to Hindon via Bajaj drain. 4. At
the time of visit discharge of treated water was done to
lagoon. Flow meter should be installed at lagoon too. 5.
Reuse of lagoon water should be done in mode of
irrigation or process use.
92
As per analysis report the Parameters pH(7.03), TSS(23mg/l), COD(132mg/l), and
BOD(12mg/l) are
115 Star Paper Mill , Saharanpur 06.03.2018 Pulp & Paper complying the standard. NIL
ETP was in operational
On line monitoring system was instaaled and opeartional.
116 Plaza Paper P.Ltd. Saharanpur 06.03.2018 Pulp & Paper CLOSED CLOSED
Rainbow Board Mill, (Unit Kraft
117 06.03.2018 Pulp & Paper CLOSED NIL
Paper) Saharanpur
118 Swaroop Paper (P) Ltd. Saharanpur 06.03.2018 Pulp & Paper CLOSED NIL
119 Hindon Filter (P) Ltd. Saharanpurr 06.03.2018 Pulp & Paper ETP unit not in operation Nil
As per analysis report the parameters BOD (05mg/l),TSS(15mg/l) and Oil & Grease
(02mg/l) are compling the satandard.
Nagar Nigam Pashuvadhshala,
120 06.03.2018 Sloughter House ETP was in operational NIL
Saharanpur
On line monitoring system was instaaled and not in opeartional during the visit
Flow meter was installed and not in operational
A.L. M. Industries (Slaughter House),
121 43, Qutab Market, Near Qutab Sher Thana, ambala 15.03.2018 Sloughter House Sludge is being discharged on own land for manure preparation which is used by villagers Nil
Road, Saharanpur
A.L.M. Industries (Meat Processing Unit) ,
122 43, Qutab Market, Near Qutab Sher Thana, ambala 15.03.2018 Sloughter House NIL NIL
Road, Saharanpur
J.J. Textile, Textile, Mahipura Road, Near MS ETP placed at separately, opposite to the industry.
123 15.03.2018 Textile & Dyeing Nil
College, Janta Road, Saharanpur Industry not operational during visit due to labor problem
Durga Textile, Mahipura Road, Near MS College,
124 15.03.2018 Textile & Dyeing NIL Nil
Janta Road, Saharanpur
125 Garg Dyeing, 47 Kamdhenu Complexd, Saharanpur 15.03.2018 Textile & Dyeing closed closed
126 Arora Hoiesery, Janta Road, Saharanpur 15.03.2018 Textile & Dyeing Not in operation Not in operation
During the time of inspection the industry was in operation but ETP
was shutdown last one month. Industry is discharging the untreated effluent into the
Deep Industries Delhi Road, I.E.,
127 07.03.2018 Textile & Dyeing drain is a violation. Nil
Delhi Road, Saharanpur
The final treated effluent water, all the parameters are well within the limit except
Sulphide(as S)=3.34
The effluent colour was blue and it was discharged into the drain
There is no functioning of sand filter and activated charcoal system
Atul Textile Industried Ltd., There is one drain was found in industry by which untreated effluent is bypassing
128 07.03.2018 Textile & Dyeing Nil
Shakumabari, Behat Road, Saharanpur (Bleached water).
The final treated effluent water is exceeding the prescribed the limits for the following
parameters: TSS = 127, BOD = 65, Oil & Grease = 13,
Industry was in operation.The final treated effluent water is exceeding the prescribed the
M/s Siddhartha Textile, limits for the following parameters: TSS = 151, BOD = 303,O&G=19, Color(Hazen) =
129 07.03.2018 Textile & Dyeing Nil
Aziz colony, Chilkana Road, Saharanpur 844,COD = 790 Sulphide(as S)=16.47. The industry ETP is not in operation effectively and
it is not complying the standard limit.
M/s Saharanpur Wooles Ltd., During the time of inspection the industry was not in operation and water sample has not
130 07.03.2018 Textile & Dyeing Nil
Delhi Raod, Saharanpur collected.
93
During the time of inspection the industry was not in operation and water sample has not
M/s Shalimar Cotton Dyeing,
131 07.03.2018 Textile & Dyeing collected due to the Holi festival holidays and labour issues Nil
Saharanpur Behat Road, Rasulpur, Saharanpur
ETP was not in operation, untreated effluent bypassed to the agriculture field
During the time of inspection the industry was in operation with full capacity. Status of
Installation & Operation of Continuous Online Emission Monitoring System at the outlet
132 M/s S.M.C. Foods Ltd. Nnauta, Saharanpur 07.03.2018 Dairy Nil
of ETP was working satisfactory. Treated effluent parameters are well within the
standard limits and it is complying
At the time of visit, unit was in operation. As informed by the management, he plant shut
down since yesterday due to amaavasyaa. Clean and hygienic environment was observed.
ETP was operational The analysis results show inlet (PD1PC) parameters of BOD
(123mg/lt), COD (296mg/lt) and TDS (196mg/lt) were reduced to outlet (PD2PC)
The unit is working adequately. Treated effluent should
M/s Pashupati Dairy (P) Ltd. parameters of BOD (05mg/lt), COD (32mg/lt) and TDS (26mg/lt). The groundwater
133 17.04.2018 Dairy be utilized at the most. Maintain clean- and green
Village Kumharhera, Dehradun Road, Saharanpur sample (PD3GW) have shown sulfate (27mg/Lt) and fluride (0.3 mg/lt). The heavy metal
environment.
contents of inlet (PD1HM)Fe (1,25mg/lt), Cu, (0.02mg/lt), and Zn(0.16mg/Lt).. Other
metals were not detectable. The heavy metal contents of outlet (PD2HM) Fe (0.12mg/lt)
and Mn ( 0.01mg/lt). Other metals were not detectable. The heavy metal contents of
groundwater (PD3GW) shows Mn (0.29mg/lt) only. Other metals were not detectable.
At the time of inspection, it was in operation. It was observed as temporary arrangement.
No solid industrial looks it wore. Most of the operators were villagers. Skill
labors/managers were lacking. Neither they applied for consent nor they had idea for it.
Even treatment facility was also very rudimentary. As such, maximum water is used and
Since it was unique case of industry operation, owner
Shree Krishna Board Mill Dehradun recycled within premises. Documents etc. were lacking. The influent (KP1PC) shows high
134 17.04.2018 Pulp & Paper was advised to have proper shade to run the unit, apply
Road, Saharanpur TSS (4114mg/l), COD ( 1848 mg/l) and BOD (596 mg/l), which was reduced to certain
to obtain valid consent and maintain proper record.
extent in the treated effluent ( TSS: 1347mg/l, COD: 395mg/l and BOD: 164mg/l). It has
high Fe content 5.38 mg/l). In the groundwater sample, only traces of Zn was observed
otherwise other metals were below detectable ranges. The F and So4 were also detected
in the groundwater samples ( ).4 and 16mg/l respectively).
Mahaveer Hand Made Paper & Board
135 17.04.2018 Pulp & Paper Factory sold and land transferred to Builders and cheap plots were available for sale
Mill
136 Shankar Board Mill Saharanpur 18.04.2018 Pulp & Paper At the time of inspection, it was closed
137 M/s Parmal Paper Ltd., Saharanpur 17.04.2018 Pulp & Paper
138 Rainbow (P) Ltd. Mills Saharanpur 17.04.2018 Pulp & Paper At the date of inspection, it was observed closed
Saharanpur Paper Board Mill,
139 04.04.2018 Pulp & Paper Sample not taken as industry is not in operation Nil
Village- Majri, Dehradun Road, Saharanpur
Majri Gramodhyod Sansthan,
140 04.04.2018 Pulp & Paper Sample not taken as industry is not in operation Nil
Village- Majri, Dehradun Road, Saharanpur
M/s Jagadamba Gramodyog Sansthan Name
141 changed to M/s Laxmi Associates, Chhagpura, 04.04.2018 Pulp & Paper Sample not taken as industry is not in operation Nil
Deharadun Road, Sharanpur.
M/s Jayna Gramodyaog Sansthan,
142 Gagalheri Name changed to M/s Ekta Gramodyog 04.04.2018 Pulp & Paper Sample not taken as industry is not in operation Nil
Sansthan, Gagalheri.
M/s Tiwaya File Board Mill,
143 04.04.2018 Pulp & Paper Sample not taken as industry is not in operation Nil
Nawada Road, Saharanpur
144 M/s Star Gramodyaog Sansthan, Manakmau, 05.04.2018 Pulp & Paper Closed Closed
94
Janhit Gramodhyog Sansthan
145 05.03.2018 Pulp & Paper Closed Closed
Dehradun Road, Saharanpur
M/s Sufi Pulp & Paper Gramodhyog
146 05.03.2018 Pulp & Paper Closed Closed
Sansthan, Gagalheri, Saharanpur
Engg., Iron and
M/s Balaji Wire Pvt. Ltd., Analysis of ETP effluent after treatment arranged by the industry shows that pH, TSS,
147 07.03.2018 Steel & Metal Nil
139·A, Anand Industrial Estate Mohan Nagar, Gzb. BOD, COD and oil & grease is within the range as per CPCB standards.
Industries
Engg., Iron and
M/s Bansal Wire high Corbon Pvt.ltd.,
148 06.03.2018 Steel & Metal Nil Nil
120-126, Anand Ind. Estate Mohan Nagar Gzb.
Industries
M/s Jai Durge Metalizing,
149 08.03.2018 Others Closed Closed
67, Anand Ind. Estate Mohan Nagar Gzb.
Sarasati Bangle Udyog, 29, Anand Industrial Estate
150 08.03.2018 Others Closed Closed
Mohan Nagar,Gzb.
Mohan Meakins Ltd., The ETP was running efficiently, the OCEMs was also installed and was being calibrated
151 Mohan Nagar, 08.03.2018 Distillery regularly the results of the samples were also No Action is required
Ghaziabad found within the limit.
Yadav Industries, Engg., Iron and
152 7, Anand Ind.Estate 08.03.2018 Steel & Metal Industry non existing at the given address Industry non existing at the given address
Mohan Nagar Gzb Industries
Engg., Iron and The State board may ensure the complete installation
A.B.Cycle Parts Pvt. Ltd., The ETP was inadequate, as also shown in the analysis results; TSS, Chromium Hexavalent,
153 08.03.2018 Steel & Metal and proper functioning of ETP to bring the effluent
S-24, South Side of G. T. Road, Gzb. Total Chromium, Iron and Zinc were found exceeding the limit.
Industries within the limits.
Engg., Iron and
A.C.E. Hardware Pvt. Ltd.,
154 13.03.2018 Steel & Metal Only assembly, packaging and ware housing. No Action is required
E-21 & 22, Kavinagar Ind. Area Gzb.
Industries
Engg., Iron and
A.S.T. Pipes, B-33, BS Road Ind. Area,
155 13.03.2018 Steel & Metal Closed Closed
Gzb.
Industries
156 Amit Textiles, 5-32, SS of GT Road 13.03.2018 Textile & Dyeing Closed Closed
During visit ETP outlet samples was collected. The analysis reports (Annexure-A) reveals
157 Amko Export, A-1, B.S. Road Ind.Area, Gzb. 13.03.2018 Textile & Dyeing that, O&G and pH are exceeded and other parameters compliance with the prescribed Not Mentioned
general discharge standards.
AT the time of visit plant was in operation. Effluent treatment plant was in operation.
Treated effluent dsicharge into domestic sewer line. During visit ETP outlet samples were
158 Amrit Foods, Amrit Nagar, G.T. Road East Gzb. 12.04.2018 Dairy Not Mentioned
collected. The parameter analysed comply with the prescribed general discharge
standards.
At the time of visit plant was in operation. Effluent treatment plant was in operation.
Electroplating,
Treated effluent reuse in the industrial process. During visit ETP outlet samples were
159 Balaji Engineering Works, 351, Pandav Nagar, Gzb. 11.04.2018 Phosphating & Not Mentioned
collected. The parameter analysed comply with the prescribed general dsicharge
Galvanizing
standards.
COD and BOD are higher side but The analysis reports reveals that, compliance with the
Electroplating,
Balaji Enterprises, B-22/1/15, B.S.Road Ind. Area prescribed general discharge standards.
160 13.03.2018 Phosphating & Not Mentioned
Gzb. Hand pump water collected near industry reveals that, Fe is exceeding but other
Galvanizing
parameters compliance with the prescribed drinking water standard.
95
At the time of visit the pant was in operation however there was no production. Since the
plant was not in operation from 4/1/18 to 27/3/18. Effluent treatment plant was not in
Continental Carbon India ltd., A·14, SS of G.T. Road
161 11.04.2018 Chemical operation due to power failure. Treated effluent reuse for gardening and road washing Not Mentioned
Gzb.
purpose. During visit ETP outlet samples were collected. The parameter analysed comply
with the prescribed general dsicharge standards.
Elin Electonics Ltd., Electrical & The analysis reports (Annexure-VII) reveals that, Fe is exceeded and other parameters
162 13.03.2018 Not Mentioned
C-142-144, BS Road, Industrial Area, Gzb. Electronics compliance with the prescribed general discharge standards.
Ph, BOD, TSS are exeeding the prescribes standards (dye and dye inddustry
Indian Textiles Co., standards).ETP sludge disposed of through Bharat Oil. Housekeeping is poor ETP
163 09.03.2018 Textile & Dyeing
E-49, B.S. Road, Gzb. equipments needs to be augmented. Treated waste discharged into drain. Unit is involved
in washing and dyeing process.
Electroplating, Unit is complying with electroplating standards. Unit was in operation during the visit. No
J.D.M. Enterprises,
164 12.03.2018 Phosphating & display board is provided. No OCEMS is installed at thr ETP. Unit is not using existing
C-223/1, BS Road Ind. Area Gzb.
Galvanizing borewell and using purchased water in their process.
Engg., Iron and
Karam Chandra Chains Ltd.,
165 09.03.2018 Steel & Metal pH is exceeding the prescribed limit (general discharge standards)
C-229, BS Road Ind.Area Gzb.
Industries
Engg., Iron and
Karam Chandra Rubber Pvt. Ltd.,
166 09.03.2018 Steel & Metal TSS in exceeding prescribed limits.
C- 230 B5 Road Ind. Area Gzb.
Industries
Kashyap Organics Pvt. Ltd.,
167 09.03.2018 Chemical Not Applicable
C-172, B.S. Road Ind. Area Gzb.
1. Unit was involved in process of electroplating. (finished and unfinished) which is closed
Engg., Iron and
lion Cycle & Rikshaw Industries, since sept 2017. New unit is only involved in fabrication of unfinished mudguard. One
168 12.03.2018 Steel & Metal
E·l0, B.S. Road Ind. Area Gzb. borewell found at IMP capacity which was found sealed in the matter of OA no. 190 of
Industries
2016. No industrial effluent is being generated.
Engg., Iron and A show cause notice to be issued to the industry to stop
Malik Nidles & Allied Products, ETP is under maintenaince, sludge being removed 2. The dry porcess of manufacturing
169 11.04.2018 Steel & Metal its dry manufacturing process immediately and submit
C-108, BS Road Ind. Area Gzb. needles from wire is in operation.
Industries the operational status of ETP.
Manav Braveries Pvt. Ltd.,
170 03.04.2018 Distillery Industry was reported close since five years as reported by the security guard Industry found closed fully no action required.
C-128, BS Road Ind.area Gzb.
Engg., Iron and
Nip Man Fastners India Pvt. ltd.,
171 03.04.2018 Steel & Metal Industry not operational 2. No sample collected as manufacturing is siezed Nothing specific as the industry found closed fully.
C- 197, BS Road Ind. area Gzb.
Industries
Closer notice is to be issued to the industry to stop its
Engg., Iron and
Northern India Cyco parts, manufacturing process immediately till the discharge of
172 11.04.2018 Steel & Metal pH, cynaide and iron are exceeding the limits
E-2, SS of GT Road Gzb. ETP meets the standard limits 2) The housekeeping of
Industries
the ETP needs to be improved
Progressive Tools & Component Pvt.Ltd. 1. Closure notice to be issued to the industry to stop its
173 03.04.2018 Automobile 1. The industry is operating without valid consent.
C-222, B.S. Road Ind. Area , Gzb manufacturing process immediately.
Electroplating,
S.S.Enterprises, Treated effluent is recycled for use in process, no discharge observed ETP working. 1. No specific action is required as unit is very small and
174 11.04.2018 Phosphating &
363, Pandav Nagar Mahrauli Gzb. Suspended Solid is exceeding the limits. used its treated effluent in house in the process.
Galvanizing
96
• The unit should obtain valid HW authorization for
disposal of Sludge generated from ETP in authorized
• The unit have valid CtO under Water & Air Acts, however, unit doesn’t have valid HW TSDF.Till obtain valid HW authorizations, unit shall issue
authorization. show cause notice.
• The unit is operating in batch wise operation. • ETP treated water should not be discharged through
Electroplating, • ETP was operational mode, however, no electromagnetic flow meter was found open drain, if applicable for ZLD.
M/s Shakshi Metals Works,
175 12.03.2018 Phosphating & installed. • The unit should install electromagnetic flow meter for
D-1A, Kavi Nagar Industrial Area, Sec-7, Ghaziabad
Galvanizing • Electromagnetic flow meter was not installed for withdrawal of groundwater. withdrawal of groundwater, so as to maintain the record
• Overall housekeeping is unsatisfactory in and around the plant premises including of usage of water for domestic and industrial purposes.
process area. There is also need of installation of such flow meter at
• ETP treated water is discharged through drain. the inlet and out let point of ETP.
• The unit shall maintain housekeeping in plant premises
including process area
• The unit should obtain valid HW authorization for
disposal of Sludge generated from ETP in authorized
• The unit have valid CtO under Water & Air Acts, however, unit doesn’t have valid HW TSDF.Till obtain valid HW authorizations, unit shall issue
authorization. show cause notice.
• The unit is operating in batch wise operation. • ETP treated water should not be discharged through
M/S Shanti Nath Manufactures ,, Electroplating, • ETP was operational mode, however, no electromagnetic flow meter was found open drain, if applicable for ZLD.
176 A-2/4, E-block, Kavi Nagar Industrial Area, 12.03.2018 Phosphating & installed. • The unit should install electromagnetic flow meter for
Ghaziabad, U.P. Galvanizing • Electromagnetic flow meter was not installed for withdrawal of groundwater. withdrawal of groundwater, so as to maintain the record
• Overall housekeeping is unsatisfactory in and around the plant premises including of usage of water for domestic and industrial purposes.
process area. There is also need of installation of such flow meter at
• ETP treated water is discharged through drain. the inlet and out let point of ETP.
• The unit shall maintain housekeeping in plant premises
including process area
• The unit have valid HW authorization. However, doesn’t have not valid CtO under Water
1. The unit should obtain Cto under water and Air actsTill
& Air Acts.
obtain Valid Cto,unit shall be closed or show cause
• Electromagnetic flow meter was installed for withdrawal of groundwater for industrial
notice may be issued. 2. The unit shall install
as well as domestic purposes. However, no electromagnetic flow meter was found
M/S Sara Exports Ltd, electromagnetic flow meter at outlet of ETP. 3)The unit
installed at outlet of ETP.
177 Plot no 35/1, 36 south slide, G.T. Road, Industrial 11.04.2018 Pharmaceutical should reuse the ETP treated water upon meeting
• Online monitoring system was working partially i.e. for pH and Temperature and
area, Ghaziabad stipulated limits, as applicable for ZLD.
whereas for other parameters was under maintenance.
2. Online CEMS should be linked to CPCB.
• Analysis result of ETP treated effluent for notified parameters are within the general
3. The unit should improve the housekeeping in and
standard for discharge on inland surface water (analysis results given at Annexure-I).
around the plant premises including process area.
• Housekeeping is unsatisfactory at ETP area
The unit shall re-install electromagnetic flow meter for
withdrawal of groundwater which was found damaged.
Also, install electromagnetic flow meter at outlet of
• The unit have valid CtO under Water & Air Acts and HW authorization. ETP was in
ETP.Etp should be in opeational mode and treated
M/s Shivam Engineering and fabrication, Electroplating, operational mode, therfore not collected. Electromagnetic flow meter was installed for
effluent shall not discharge through open drain, if
178 A -282, south side, G.T. Road Industrial area, 11.04.2018 Phosphating & withdrawal of ground water and the same was found damaged. However,
applicable for ZLD. ETP shall be in operational mode
Ghaziabad Galvanizing electromagnetic flow meter was found installed at outlet of ETP. Overall housekeeping is
and treated water should not be discharged through
unsatisfactory in and around the plant premises including process area.
open drain, if applicable for ZLD.
The unit should improve the housekeeping in and
around the plant premises including process area.
97
• The unit should have valid Consent to operation under
Water & Air acts and HW authorization for disposal of
Sludge generated from ETP in authorized TSDF.Till obtain
valid HW authorizations, unit shall issue show cause
• The unit doesn't have valid CtO under Water & Air Acts and HW authorization. ETP
notice.
M/s Shri Guru Kripa Industries, Electroplating, outlet sample could not be collected as ETP was not in operation mode.ETP treated water
• ETP should be in operational mode and treated water
179 E-25, south side, Industrial area, G.T. Road, 11.04.2018 Phosphating & is discharged to open drain and sludge generated from ETP are sold to local detergent
should not be discharged through open drain, if
Ghaziabad, U.P. Galvanizing making dealers.. Overall housekeeping is unsatisfactory in and around the plant premises
applicable for ZLD.
including process area.
• ETP sludge should be analysed & characterised before
selling to third party for the purpose of detregent
making. The unit shall maintain housekeeping in plant
premises including process area.T
The unit have Valid Cto under Water &Air Acts and HW authorization. The unit was found ETP should be reconstructed prior to resuming the plant
M/s Suruchi Dyeing Udyog Pvt Ltd
180 11.04.2018 Textile & Dyeing not in operational mode. ETP system was dismantled, therfore samples could not be in operation. Treated effluent shall be analysed 7
37, South side Industrial area, NH 24, Ghaziabad
collected unit operator informed that treated effluent was used for agricultural purposes. characteriszed prior to utilizing in agricultural purposes.
the unit is advised to install ETP immediately meanwhile
Engg., Iron and
M/s Tarun International Hg content in ground water exceed to the permissible limit, whereas oil & Grease limit in closure notice may be issued as no ETP installation is
181 05.04.2018 Steel & Metal
C-15, SS of GT road, Ghaziabad waste water discharge also exceed to the prescribed limit present and discharging wastewater directly nto local
Industries
drain.
The unit closed since 2012. At the time of the visit no industrial activity observed instead
M/s Vimal Organics Pvt Ltd, Non working/Existing industry status to update in the
182 05.04.2018 Others the plant was under dismantling process using gas cutters to cut and dismantling the unit
D-35BS Road, Industrial area, Ghaziabad record pl
and sold them in scrap.
The unit is having valid consent upto 31.12.19 under Water & Air Act. No animal were Industry is having valid consent upto 31.12.19. However
M/s Al Nafees Frozen Foods Export, found in the premises of the unit at the time of viist but ETP was operative. On asking we it is a matter of concern that why production is
183 06.04.2018 Sloughter House
Hapur Rd. Dasna Ghaziabad were told that production is voluntarily stopped.Hg value is exceeding in hand pump voluntarily stopped at the time of visit and how ground
water with permissible limits. water is contaminated with Hg in the area.
The unit is having valid consent upto 31.12.19 under Water & Air Act. No animal were
M/s AI-Naseer Export Pvt. Ltd., Industry is having valid consent upto 31.12.19.However,
found in the premises of the unit at the time of visit but ETP was operative. On asking we
184 Khasara no 2761 & 2762 ViII- Bhoorgarhi Dasna , 06.04.2018 Sloughter House industry owner may ask to control TSS value in their
were told that production is voluntarily stopped. TSS value exceeding in waste water
Ghaziabad effluent water.
from permissible limit
At the time of visit no animal were found in the premises of the unit and team were not
Industry already closed and sealed by GDA. However it is
M/s Eagle Continental foods pvt ltd, allowed to cross the cordoned ribbon made as seal area by GDA. The industry sealed by
185 05.04.2018 Sloughter House a matter of concern that how ground water is
Dasna Ghaziabad (Sealed by GDA) GDA on dated 5.2.18 even STP also sealed. Hg value is exceeding in bore well water with
contaminated with Hg in the area.
permissible limits.
No information about valid consent under Water and Air
1. No information having about the valid consent under water and Air Act, with the Act with the industry.
industry, as at the time of visit no concerned person was available in the unit.
M/s Exclusive leathers,
186 06.04.2018 Tannery 2. At the time of visit unit was operative and ETP also found operative. Sample were Sample collected and get analyzed in CPCB Laboratory
Khasara No, 2751, Bhoorgarhi Dasna , Ghaziabad
collected from ETP out let as well as Ground water also collected, for analysis in CPCB and found that BOD value is 17 Times more than the
Laboratory. 3. BOD &TSS value exceeding in Waste-Water from the permissible limit. prescribed limit of 30mg/L, TSS is also exceeding with
the prescribed limit of 100mg/L.
98
The unit shall optimize chemical dozing for removal of
iron from the effluent and therefore to meet the notified
ETP is operated intermittently i.e. in batch mode as and when reused. The unit has
standard. The unit shall make partition in sludge drying
Electroplating, provided single sludge drying bed for sludge dewatering and drying which will facilitate
Futuro Component Pvt. Ltd., beds so that these can be alternatively used for sludge
187 13.03.2018 Phosphating & only dewatering and not drying. The unit was found complying notified effluent standards
koshilya road Hindon River, Dasna, Ghaziabad dewatering as well as drying. The unit shall install flow
Galvanizing for all parameters except for Fe : 4.72 mg/l (Std 3 mg/l). Analysis result enclosed. The unit
meter at ETP outlet so as to quantify daily quantity of
has maintained records of daily chemical consumed for effluent treatment.
effluent treated in ETP and further maintain daily
records.
1.Unit shall provide additional sludge handling facility. 2.
M/s International agro Foods (Integrated slaughter Unit was found complying with the prescribed norms (analysis results annexed). There is
Unit shall carry out proper calibration of the OCEMS at
188 House) Plot no. 2764 - 2766, Bhurgardi, Dasna, 08.03.2018 Sloughter House variation between the Online Continuous Effluent Monitoring System (OCEMS) reading
regular interval so as to obtain continuous accurate
Distt. Ghaziabad Uttar Pradesh and laboratory results.
results.
Unit not in operation since last 2 months. Unit shall be
M/s Karan Frozen Foods, Unit not in operation during the visit. Plant not operated since last 2 months as informed
189 08.03.2018 Sloughter House re-inspected to check compliance once it re-start
Plot No. 2770, 2772, Burgadi, Dasna, Ghaziabad by Unit’s representative.
operation.
Poor maintenance of ETP observed since it is closed
M.D.Frogen Foods Export, from August 2017. Accordingly, the Unit shall carry out
190 Vill- Bhoorearhi Dasna Ghaziabad. (Since August 08.03.2018 Sloughter House Unit not in operation since august 2017. Needs to carry out major repair works in ETP. necessary repair works in ETP and submit report to
2017) UPPCB. UPPCB shall only after verification of repair
works allow the Unit to operate.
Flow meter to be installed for quantification of water
reused in the process. The unit shall get water and
ETP used for recycle of excess flow of shaddy shell back to pulper. Flow meter not
material balance audit done from expert institute such
installed for quantification of water reused in the process. No effluent discharge observed
M/s Shree Ganga Paper Mills Pvt. Ltd. Bhurgadi, as CPPRI/IIT/NEERI and submit report certifying ZLD
191 13.03.2018 Pulp & Paper from the ETP and entire quantity is recycled to the process. Boiler ash found stored in
Dasna, Hapur Road, Ghaziabad, UP status of the unit to UPPCB and CPCB. Unit shall provide
open resulting in re-suspension to the environment. Analysis results of water reused by
camera in the ETP area for checking recycling of water
unit is enclosed.
back to the process. Boiler Ash shall be stored in proper
covered area for temporary storage before disposal.
M/s Triyash Enterprises, ETP not operational at the time Inspectional, started during the Inspection and samples
Regular functioning & operation of ETP should be
192 Khasra no-2751, Village-Bhoorgarhi Dosna, 26.04.2018 Tannery were collected. Analysis results of ETP Outlet samples shows exceedance to the limits
ensured.
Ghaziabad specified for the parameters BOD & Sodium.
M/s U.P. Board & Container Pvt. Ltd.,
193 08.03.2018 Pulp & Paper Closed Closed
Dasna Ghaziabad
99
1. The unit is not meeting the quality of effluent being
discharged in terms of B.O.D & TSS (consented
parameter) and other parameters, as per revised
standards for textile industries and the unit shall be
directed to close down the operations, until the ETP
During inspection samples were collected from the ETP outlet and analysis results
provided is suitably augmented, so as to meet the
indicate that the treated effluent being discharged to the municipal drain exceeds the
prescribed standards/limits. 2. The unit shall carry out
M/s Devtara Industries, prescribed standards/consent limit w.r.t pH, COD, BOD, TSS & Color parameters. Even
194 08.03.2018 Textile & Dyeing performance evaluation of the existing ETP through a
Meerut Road Duhai Muradnaaar Gzb. though the unit has provided full-fledged ETP, the analysis result indicates improper
reputed organization and shall assess the requirement of
operation and lack of maintenance. The effluent from the ETP is discharged to the
augmentation of ETP, including addition of biological
municipal drain, through a closed underground pipeline of approximately 2 KM length.
treatment unit, if required, for meeting the BOD
discharge standard. The regular O&M of the ETP shall
also be ensured. 2. UPPCB shall keep the unit under
strict vigil and regular monitoring may be carried out to
ensure compliance.
1. The unit is not meeting the quality of effluent being
discharged in terms of B.O.D (Consented parameter) and
During inspection samples were taken from the ETP outlet. Analysis results shows that other parameters, as per revised standards for textile
values of COD, BOD, TDS and Color exceeds the value of prescribed standards/consent industries and shall be directed close down the unit until
limits. The operation of the ETP was not continuous and ETP was operated after the visit the ETP provided is suitably augmented and regular
of the team for collection of samples. It was evident during the visit that the unit is not O&M of the ETP is ensured. 2. UPPCB shall keep the unit
M/s A & A, properly maintaining the operation of the ETP. The ETP is located at congested area under strict vigil and regular monitoring may be carried
195 08.03.2018 Textile & Dyeing
S-50, Loni Road Ind. Area Site II Mohan Nagar Gzb. within the processing section and seems inadequate and all ETP units including the sludge out to ensure compliance. 3. Considering that many of
collection tanks are also located at this area within the same building. There was no such small scale units in the industrial estate has
proper approach or terminal manhole for collection of samples. It was evident that he limitation of area, man power etc. and are not able to
operation of ETP is a neglected area and there were no dedicated/trained staff available provide dedicated man power to ensure proper
for proper O&M of ETP Some of the photographs taken during the visit are given below; operation of the ETP, as observed during the visit, the
possibility of installing a CETP as a joint venture of the
industrial units in the industrial area shall be explored.
100
1. The unit is not meeting the quality of effluent being
discharged in terms of B.O.D & TSS (Consented
parameter) and other parameters, as per revised
standards for textile industries and the unit shall be
The ETP was found not in operation due to problems in the power supply board. However immediately directed to close down the operations, until
effluent discharge was observed meeting to the nearby drain and samples were collected the ETP provided is put into regular operation and
at this meeting point. Analysis results shows that values of pH, COD, BOD, TDS and Color suitably augmented so as to meet the prescribed
exceeds the value of prescribed standards/consent limits. During the visit, it was standards/limits. The regular O&M of the ETP shall also
observed that the ETP was not in operation due to problems in the power supply board to be ensured. 2. UPPCB shall keep the unit under strict
M/s A.N.Fabric (Ex. Name B.K. Enterprises), 5/6, the ETP & it was informed by the unit representative the same is being rectified. The ETP vigil and regular monitoring may be carried out to
196 08.03.2018 Textile & Dyeing
site-2, Loni Road, Gzb. tank was found to be filled with the effluent & discharge of effluents to the nearby drain ensure compliance. 3. Considering that many of such
was observed from the unit & samples were collected from the discharge point. It was small scale units in the industrial estate has limitation of
evident during the visit that the unit is not properly maintaining the operation of the ETP. area, man power etc. and are not able to provide
The ETP is located at congested area among the processing and seems inadequate. It was dedicated man power to ensure proper operation of the
evident that he operation of ETP is a neglected area and there were no dedicated/trained ETP, as observed during the visit, the possibility of
staff available for proper O&M of ETP. installing a CETP as a joint venture of the industrial units
in the industrial area shall be explored. 4. U.P Jal Nigam
shall further examine the higher level of fluoride values
found in the hand pump and assess suitability for
drinking purposes.
M/s Ajay Washing,
S-62, Loni Road Ind. Area, Mohan Nagar Gzb.
197 08.03.2018 Textile & Dyeing Closed Closed
Presently Wall Putty Manufacturing Unit namely
M/s Wall Shine is in operation
The unit is listed as a textile unit (Pashmina shawl manufacturing) in the list provided for
inspection. However the unit is presently carrying out assembling/making of Home
furnishing blinds & awnings. (Dry process) The consent from UPPCB under the Water Act
1. The changes in the operation of the unit shall be
also mentions the unit as furnishing blind making unit, without permission for any textile
recorded and the unit may be considered as a dry
dyeing/washing/bleaching and generation of industrial effluent. Only 8 KLD domestic
process unit at present and the same may be updated in
M/s Alps Industries Ltd., Unit-3, A-2, Loni Road effluent generations is permitted, as per the Consent order.
198 08.03.2018 Others the records. 2. UPPCB shall ensure availability of proper
Mohan Nagar Gzb. Raw materials such as metal rods/railings and specialized cloth etc are mainly imported
treatment facilities in the event of any
on emand basis. Exact quantity was not available. Unit is operating only dry processes
process/operation changes in the unit amounting to
and is presently utilizing water from piped connection for domestic purposes. There is no
generation of industrial effluent.
effluent generation/discharge from present operations, as observed during visit and
hence no samples were collected. An old ETP was observed in the unit, the tanks of
which were found completely dry.
M/s Ambica Steels Ltd., Engg., Iron and
Monitoring value of pH shows highly acidic effluent, which is being used for horticulture The unit should be asked to clarify reason of high pH
199 plot no. 32 site-2 Loni road Industrail Area Mohan 07-03-2018 Steel & Metal
after treatment. Other paramenters are within the limits. Housekeeping was good. effluent.
Nagar, Ghaziabad, U.P. Industries
Units was found complying with the norms Units was not maintaining any logbook for
M/s Asha Prints,Ltd., The unit should install the flow meter on inlet point of
200 08-03-2018 Textile & Dyeing fresh water intake Unit had not installed any flow meter for fresh water intake
A-5/4, 32 Loni road Mohan Nagar, Ghaziabad, U.P. fresh water intake.
Housekeeping was good
M/s Asha Tanu PrintsLtd.,
201 08-03-2018 Textile & Dyeing Unit was operating without any CTO/CTE Housekeeping was very poor. Unit should be issued closure direction
A-5/4 Loni road Mohan Nagar, Ghaziabad, U.P.
101
1. The unit should be asked to clarify reason of high pH
Engg., Iron and
M/s Bansal Wire Industries Ltd, Monitored value of pH shows highly acidic effluent, Other paramenters were within the effluent. 2. The unit should install the flow meter on
202 07-03-2018 Steel & Metal
B-3, Loni road, Mohan Nagar, Ghaziabad, U.P. limits. Housekeeping was good. inlet point of water intake. 3. The unit should maintain
Industries
logbook for fresh water utilisation.
1. The unit should be asked to clarify reason of high pH
M/s Bansal Wire Industries unit-III Ltd, Engg., Iron and
Monitored value of pH shows highly acidic effluent, Other paramenters were within the effluent. 2. The unit should install the flow meter on
203 B 5-6, Site-2, Loni road Mohan Nagar, Ghaziabad, Steel & Metal
07-03-2018 limits. Housekeeping was good. inlet point of water intake. 3. The unit should maintain
U.P. Industries
logbook for fresh water utilisation.
Engg., Iron and
204 Harig India Ltd., GT Road Mohan Nagar Gzb. 09-03-2018 Steel & Metal Closed Closed
Industries
M/S Kishan lal & Co.
205 09.04.2018 Textile & Dyeing
13-A/14 site 2, Loni road,Mohan Nagar Ghaziabad
The industry is inspected on April 09, 2018 by the officials of CPCB, UPPCB and UPJN. The
OCEMS is not installed. ETP is found operational and the sample was collected from the
206 M/s Laxmi Dyeing Pvt LTd 09.04.2018 Textile & Dyeing
outlet of the ETP. The analysis results indicate the compliance of standard for disposal in
drain.
M/S M.G. Electronics Pvt LTd,
207 6 loni road, Industrial area, Mohan Nagar, 09.04.2018 Others Unit operates for 8-10 days a month depending n work.
Ghaziabad
M/S Dyer
208 S102, Loni road, Industrial area, Mohan Nagar, 09.04.2018 Textile & Dyeing Industry found closed and premises used as godown
Ghaziabad
M/s M.S.D. Dytex pvt Ltd,
209 5/2 Loni road, Industrial area, Mohan Nagar 09.04.2018 Textile & Dyeing Industry found closed. No person was availble.
Ghaziabad
1)The industry does not have the name board on its entry gate.2)The industry was 1)The flow meter should be installed to measure ground
Mayur prints, observed closed since 2 weeks. 3) The bore well water is used for both printing and water consumption. 2) The industry should obtain
210 5/8 site -2, loni road Ind Area, Mohan Nagar, 11.04.2018 Textile & Dyeing domestic use. 4) The flow meter has not been installed.5) ETP was found not operational permission from CGWB. 3) The industry should consult
Ghaziabad since two weeks 6) The used water is discharged to Hindon through drain located in front UPPCB for harardous waste 4) The industry should
of industry. maintain the log book record.
The work done by the industry is assembling tractor parts 2) Paint is consumed for work. 1) The flow meter should be installed to measure ground
Mita Haring India Ltd, GT road, Mohan Nagar, 3) ETP is not operational due to some repairing/ construction work 3) It uses bore well water consumption 2) The industry should obtain
211 11.04.2018 Automobile
Ghaziabad water for industrial use.4) It uses bore well water for industrial use 5) The flow meter has permission from CGWB 3) The industry should maintain
not been installed. 6) The water is discharged to hindon through drain the log book record.
The industry has shut down the garment dying process since 3 years 2) It has applied for
1)The flow mater should be installed to measure ground
permission for new work process to SIDC, Kanpur 3) It has not informed UPPCB for
water consumption. 2)The industry should ontain
Micro Gartex Industries, approval of new work process. 4) Now it manufactures HDPE granules and plastic dana. 5)
212 12.04.2018 Others permission from CGWB.3) the industry should inform
C-2, site II, Loni road, Ghaziabad The manufactured products are done by using plastic and thermocol. 6) IT uses bore well
the local body a(UPPCB) for the new process. 4) The
water for domestic and colling process of plastic product. 7) ETP is not used in this type of
industry should maintain the log book record.
industry.
Animesh Graphic Engineers, 1) The industry found at this addree was different from the list given for inspection. 2)
S-74, Loni road, site II, Ghaziabad but Listed as New The present industry name is Animesh Graphic Engineers and job work is multi-color
213 11.04.2018 Others
colour Fashion & dying, S-74, Loni Road, site 2, offset printing. 3) The ETP is not needed in this type of industry 4) A water tap is installed
Ghaziabad for use of domestic purpose only.
102
It is recommended that unit may be directed to take
Non Stop Colours, Based on the Analysis result of final ETP discharged out of 7 parameters, 1 parameter necessary steps to improve the efficiency of Effluent
214 06.04.2018 Textile & Dyeing
Plot No-3, Loni Road Site-2, Gzb. (BOD) was not complying as treated effluent standards as per CPCB guidelines treatment plant so that treated effluent shall comply
with the prescribed standards in respect of BOD
Om Printers,
C-3, Site-2, Loni Road Mohan Nagar Gzb.
- Purchased by M/s Ram Avtar, S.R. Prints from
215 12.4.2018 Textile & Dyeing closed closed
M/s Om Printers
- Permission of transfer Plot No. C-3, Industrial
Area, Site –II, Loni Road, Ghaziabad
Name of industry given in the list as Pawan Dyers at address S-83 was not found. Another
M/s Sun Labtek Equipments Pvt. Ltd.
industrial unit named SUN LABTEK EQUIPMENTS PVT LTD was found. Industrial unit was a
Loni Road Industries Area Ghaziabad was Status of Address change may be verified by UPPCB for
216 12.04.2018 Textile & Dyeing dry process unit hence no ETP. Industrial Unit was not using any Water During the
operational instead of Pawan Dyer, S-83 Loni Road issuing any consent required for the Industrial Unit.
commercial process (Dry Unit) hence sample could not be collected for Waste water
Ind. Area Mohan Nagar Ghaziabad
discharge. Water is used only for domestic purpose from bore Well. Information not
available regarding any kind consent obtained from UPPCB, mainly for Air & Hazardous.
As per the analysis repot the parameters pH, Phenol, and Total Chromium are
complying the standards.Total Suspended Solids (TSS), Bio-Chemical Oxygen Demand
S.R.Prints, (BOD) and Oil & Grease are exceeding the acceptable limit as per Standard – Environment Closer notice may be issued to the industry because of
217 03.04.2018 Textile & Dyeing
C-I, Loni road Ind.Area Mohan Near Gzb. (Protection) Act, 1986. Untreated effluent discharge to drain. Electromagnetic Flow meter untreated effluent discharged into the drain.
was not installed. Installation & Operation of Continuous Online Emission Monitoring
system at the Outlet of ETP was not installed.
1. As per the analysis repot the parameters pH, Total Suspended Solids (TSS), Bio-
Sahi Exports (Sarla Fabrics Ltd.), Chemical Oxygen Demand (BOD) and Total Chromium are complying the standards. 2)
218 03.04.2018 Textile & Dyeing complying the EPA standards.
30, Loni Road lnd.Area Mohan Nagar Gzb. ETP was in operational. 3) Installation & Operation of Continuous Online Emission
Monitoring system at the Outlet of ETP was installed.
1. pH, TSS and Bio-Chemical Oxygen Demand (BOD) are exceeding the acceptable limits Industry may be asked to control pH TSS and Bio-
M/s Sai Processing as per Standard-Environment (Protection) Act 1986. 2) Electromagnetic Flow meter was Chemical Oxygen Demand (BOD)in discharge by
219 03.04.2018 Textile & Dyeing
7/37, site no-2 Loni Road Mohan Nagar Gzb. not installed. 3) Continuous Online Emission Monitoring system at the Outlet of ETP was improving the treatment system installed and
not installed. Flow Diagram of ETP was not provided. installation of Electromagnetic Flow meter.
1. M/s. Santosh Wire Industries does not exist at C-6, Loni Rd. Ind. Areal, Mohan Nagar, M/s. Santosh Wire Industry does not exist at the said
M/s Santosh wire industries,
Engg., Iron and Gaziabad and closed a long back, instead we found a Dry-unit functioning in the name of address. But a new unit found operative as M/s. V.J.
C-6 Loni Rd Ind area, Mohan Ngr, Ghaziabad not
220 06.04.2018 Steel & Metal M/s V.J. Metal Components Pvt. Ltd., which are making vehicle’s shoe-brake-plates by Metal Components Pv. Ltd., making vehicle’s brake shoe
existing at this address instead M/s V.J. metal
Industries cutting Iron-sheet with “Press cutting ” machines. plate by press cutting of metal sheet, Hence official
components pvt Ltd in opeartion
2. The new-unit was not having any consent or permission to operate. record may pl. update.
Saroj Creation Pvt. Ltd.,
221 12.04.2018 Textile & Dyeing dry and non polluting industry due to dry industry, there is no recommendation
C-24, 25 Loni Road Ind Area Gzb.
Ramesh Impacts Pvt. Ltd. in place of Shri Balaji Processors.
Shri Balaji Processors,
222 06.04.2018 Textile & Dyeing Packing work of readymade Garments for Export due to dry industry, there is no recommendation
S-132, Harsha Compound, Mohan Nagar Gzb.
Dry Industry
During the inspection of the unit, the ETP was under
maintenance. The unit may be directed not to operate
Sunny Prints, The industry is limited to printing of saree only. During inspection, the ETP installed was without ETP. In addition, as the industry is located in a
223 09-03-2018 Textile & Dyeing
5/7, Site-II Industrial Area, Loni Road, GZB. under maintenance. cluster area, the individual units can be directed to
comply with Effluent Discharge Standards at utmost
priority.
103
The treated effluent found to be non-compliance.
Engg., Iron and
Yadav Industries, Accordingly, the unit may be asked to upgrade its ETP
224 09-03-2018 Steel & Metal The industry is primarily for wire works with ETP of 30 KL/day installed capacity.
C-11, Loni Road Ind.Area Gzb. operations in order to meet the prescribed effluent
Industries
standards.
The treated effluent found to be non-compliance.
Electroplating,
Agarwal Galvanizing, Unit-2, The industry is engaged in galvanizing of door fitting accessories like handle, hinges, locks, Accordingly, the unit may be asked to upgrade and
225 08-03-2018 Phosphating &
A-8/6, Meerut Road Ind. Area Guldar Ghaziabad knobs, etc. The unit has installed ETP for industrial effluent and stack for emissions. proper operations of ETP in order to meet the
Galvanizing
prescribed effluent standards.
Albert David Ltd., The unit found to be compliance of effluent parameter
226 08-03-2018 Pharmaceutical The industry is Pharma manufacturing unit with ETP of 200 KL/day installed capacity.
B-13, Meerut Road industrial Area Ghaziabad. except oil & grease.
The recycled water used by the industry for internal
purpose is acidic in nature thus neutralization within
Chemo Pulp Tissues Pvt. Ltd., The industry is only manufacturing Paper Board and raw material for that is being
227 08-03-2018 Pulp & Paper settling tank is recommended. In addition, the industry
A-4, Set 22, Meerut Road Ind. Area Gzb. procured from outside
can be asked to increase green cover over unused land
to minimise dust generations within its premises.
Crop Health Product Pvt. Ltd.,
228 08-03-2018 Pesticides
-1 D- 31/1, Meerut Road Ind. Area Gzb.
The unit may be asked to provide adequate effluent
Deewan Reclame Rubber Ltd.,
229 13-03-2018 Others The unit is not in operation since last two years due to financial reasons. treatment plant before restart of operation and the
A-3, Meerut Road Gzb.
same should be informed to CPCB and UPPCB.
The industry is engaged in manufacturing & assembling of the elevators (Lifts). As
per the consent dated 19.03.2018 the unit does not use any water in the production and
no industrial effluent to be generated. The washing effluents are treated in ETP
Engg., Iron and Direction u/s 5 of Environment (Protection) Act
comprising of neutralization and alum dosing only. As informed the ETP is used as per
230 E.C.E. Ltd., A-20, Meerut Road Ind. Area Gzb. 13.03.2018 Steel & Metal 1986 may be issued to the unit in view of non-
requirement only. A sample was collected from the ETP outlet and sample is exceeding
Industries compliance of Effluent discharge norms.
the prescribed limits w.r.t. parameters pH (2.09 mg/l < 5.5- 9.0 mg/l), COD (12280
mg/l), BOD (8335 mg/l), Fe (17.71 mg/l > 3 mg/l), Zn (5.37 mg/l > 5 mg/l). The unit
has not provided proper dust collection system at the powder coating section.
The unit is manufacturing fruit juice from the fruit pulp.-The grab effluent sample was The unit may be directed to operate its Effluent
Parle Agro P Ltd. Agro Based & Food
231 09-03-2018 collected from the outlet of ETP. Analysis results show the treated effluent is exceeding Treatment Plant properly so as to achieve prescribed
A-7, Sector-22 Meerut Road, Ind. Area, Gzb. Processing
the prescribed limit for Oil & Grease. (11mg/l >10mg analysis reports at Annex.6) standards.
1. The unit is manufacturing Unani Medicine- Sharbat, Syrup, Tablets etc. 2. The unit and
its Effluent Treatment Plant(ETP) was operational during visit.The grab sample collected
Hamdard (Wakf) Laboratories, (1 & 2) The direction u/s 5 of E(P) Act 1986 may be issued to the
232 13-03-2018 Pharmaceutical from ETP outlet is exceeding the prescribedblimits w.r.t. parameter. TSS (380mg/l
B-2 &3 Meerut Road Gzb. unit as the unit is not meeting effluent discharge norms.
>100mg/l), COD (11580mg/l > 250mg/l )and BOD (6984mg/l >30mg/l). Analysis report at
Annex.5
1. The unit and its ETP was found operational during visit.2. The grab sample from ETP 1. The unit is cigarette manufacturing unit and water is
International Tobacco Co. Ltd., outlet was collected during visit.3. The analysis result of ETP outlet are within the limits not used in process.2. The treated effluent is meeting
233 09-03-2018 Others
Meerut Road, Guldhar, Ind. Gzb. for parameter ph= 7.94, TSS= 18mg/l, COD= 40mg/l, BOD= 7mg/l (Analysis result at the prescribed standard., No action is required at
Annex.6) present.
1. The unit may be directed to operate its Effluent
1. The unit and its ETP was found operational during visit.2. The unit has provided
Treatment Plant properly so as to achieve prescribed
chrome recovery in the ETP,3. The grab effluent sample collection from ETP outlet and
Kathuria Brothers, standards.2. The chemical bags should be stored at the
234 09-03-2018 Tannery treated effluent is exceeding the prescribe limits w.r.t parameter COD (4896 mg/l >
A-l2, Site -3, Industrial Area, Meerut Road Gzb. designated storage yard.,The housekeeping of the unit
30mg/l) and BOD (2246 mg/l > 30mg/l) Analysis report at Annex. 6,4. The bags of
needs improvement and water spillage in the process
chemical were stored in open area., Housekeeping of the unit need improvement
area should be prevented.
104
1.On the basis of observations, it is recommended that
unit may be directed to close its operations till it takes
necessary steps to improve the efficiency of Effluent
1. From the analysis results , it is observed that finally discharged and treated effluent by
Treatment Plant so that the treated effluent shall
the unit is not complying for Zinc (20.15 mg /l as against standard limit of 5 mg /l). 2. The
comply to the prescribed standards. 2. It is
unit is not having any flow meter at Effluent Treatment Plant. Hence the unit does not
recommended that the unit may be directed to install
Electroplating, have any records of quantity of waste water treatment. 3. From the records made
Kathuria Brothers,( Cycle Section) flow meter at Effluent Treatment Plant and maintain
235 05-03-2018 Phosphating & available by the unit during inspection, it was observed that the unit has not disposed ETP
A-12 Meerut Road Industrial Area Gzb. proper records of effluent treatment. 3. It is
Galvanizing sludge and other Hazardous Wastes after 01 August, 2017. Hence it was observed that
recommended that unit may be directed to close its
the unit violated Section 8 of Hazardous and Other Wastes (Management and
operations till it disposes all the stored ETP sludge and
Transboundary Movement) Rules, 2016 which specify that the occupiers of facilities may
other hazardous wastes in a scientific manner to a
store the hazardous and other wastes for a period not exceeding ninety days.
Treatment, Storage, and Disposal Facility (TSDF) for
hazardous wastes, with proper maintenance of disposal
records.
1. From the analysis results, it is observed that finally discharged and treated effluent is
not complying for Sulphate (593 mg/l as against standard limit of 400 mg/l) and nickel
(25.36 mg/l as against standard limit of 3 mg/l). 2. During inspection, it was observed that 1. On the basis of observations it is recommended that
the unit has dumed the hazardous wastes including ETP sludge and process sludge to a unit may be directed to close its operations till it takes
nearby plot. The unit informed that it owns the plot. ETP sludge and other hazardous necessary steps to improve the efficiency of Effluent
wastes were dumped over the open ground, therby causing soil pollition. The possibility treatment plant so that the treated effluent shall comply
Electroplating,
Marshal Cycles, that hazardous chemicals from the dumped sludge and other hazardous wastes may to the prescribed standards. 2. It is recommended that
236 05-03-2018 Phosphating &
B-17/18, Meerut Road Industrial Area Gzb. enter ground water during rainy season cannot be ruled out. 3. The analysis results of unit may be directed to close its operations till it
Galvanizing
ground water sampled from bore well within the industry premises indicates exceedance disposes all stored ETP sludge and other hazardous
of Pb and Kg in ground water as against the permissable limits in absence of alternate wastes in a scientific manner to a treatment, Storage
source specified by BIS. 4. From the records made available by the unit during inspection, and Disposal facility (TSDF) for hazardous wastes with
it was observed that the unit has not disposed ETP sludge and other Hazrdous wastes proper maintenance of disposal records.
after 1 aug 2017. Hence it was observed that the unit violated Section 8 of Hazardous and
other wastes Rules, 2016.
Engg., Iron and
Mascot India Tools Ltd.,
237 05-03-2018 Steel & Metal
A-2, Meerut Road Ind. Area Gzb.
Industries
105
1.It is recommended that unit may be directed to close
its operations till it provides a proper settling tank to the
Effluent Treatment Plant to settle the suspended solids.
2. It is recommended that unit may be directed to close
its operations till it takes necessary steps to improve the
1. From the analysis results, it is observed that finally discharged and treated effluent is
efficiency of Effluent Treatment Plant so that the treated
not complying for pH, Suspended solids . Total Chromium, Lead, iron and Zinc. 2. The
effluent shall comply with the prescribed standards. 3. It
effluent treatment plant was observed inadequate. The unit carries out chemical dosing
is recommended that the unit may be directed to install
as well as settling in the same tank. As a result, the treated effluent was observed to have
Electroplating, flow meter at Effluent Treatment Plant and maintain
North Land Cycle Co. Ltd., high concentration of suspended solids and heavy metals exceeding prescribed limits. 3.
238 07-03-2018 Phosphating & proper records of effluent treatment. 4. It is
D-21, meerut Road Industrial Area Ghaziabad The unit is not having any flow meter at Effluent Treatment plant. hence the unit does not
Galvanizing recommended that unit may be directed to close its
have any records of quantity of waste water treatment. 4. The unit failed to show any
operations till it disposes all the stored ETP sludge and
evidence of disposal of sludge or other hazardous waste. 5. the unit does not have valid
other hazardous wastes in a scientific manner to a
consent to operate and authorization under Hazardous waste rules granted by UP
Treatment, Storage, and Disposal Facility (TSDF) for
Pollution Control Board.
hazardous wastes, with proper maintenance of disposal
records. 5. The unit may be directed to remain closed till
it obtains valid consent to operate and Authorization
under Hazardous waste rules granted by U.P. Pollution
Control Board.
It is recommended that unit may be directed to close its
operations till it takes necessary steps to improve the
efficiency of Effluent Treatment Plant so that the treated
effluent shall comply with the prescribed standards. 2. It
1. From the analysis results, it is observed that finally discharged and treated effluent is is recommended that the unit may be directed to install
not complying for pH. .2. The unit failed to show any evidence of disposal of ETP sludge flow meter at Effluent Treatment Plant and maintain
after March 03,2017. Hence, unti violated Section 8 of Hazardous and other wastes Rules, proper records of effluent treatment. 3. It is
Engg., Iron and
Ramsons Enterprises, 2016 which specify that the occupiers of facilities may store the hazardous and other recommended that unit may be directed to close its
239 07-03-2018 Steel & Metal
D-21 A, Meerut Road Gzb. wastes for a period not exceeding ninety days. 3. The unit is not having any flow meter at operations till it disposes all the stored ETP sludge and
Industries
Effluent treaatment plant. hence the unit does not have any records of quantity of waste other hazardous wastes in a scientific manner to a
water treatment. 4. The unit does not have valid consent to operate and authorization Treatment, Storage, and Disposal Facility (TSDF) for
under hazardous waste rules granted by UP pollution control Board. hazardous wastes, with proper maintenance of disposal
records. 4. The unit may be directed to remain closed till
it obtains valid consent to operate and Authorization
under Hazardous waste rules granted by U.P. Pollution
Control Board.
Roxy Investment Pvt.Ltd., Electrical &
240 07-03-2018
C-3, meerut Industrial Area Ghaziabad Electronics
At the time of inspection team has found, industry was closed since last few years
Samtal Electron Devices Ltd., Electrical & according to the Guard Mr. R. D. Dixit and industry also sealed by State Bank of India. Due
241 09-03-2018 Nil
1, 2, 3 Sect-22, Meerut Road Gzb. Electronics to this reason no inspection has been performed., Therefore, concerned division may take
the necessary action based on the above observation.
Based on the Analysis result of final ETP discharged out of 13 parameters, 1 parameter It is recommended that unit may be directed to take
Engg., Iron and
Shri Ram Piston & Rings Ltd., (Cyanide) was exceeding with the prescribed standard of Nickel and Chrome plating final necessary steps to improve the efficiency of Effluent
242 5.3.2018 Steel & Metal
MeerutRoad Ind. Area Gzb. ETP outlet discharge. Validity of consent till 31.12.17.Further unit has applied for consent treatment plant so that treated effluent shall comply
Industries
on date 16.2.18 on online. with the prescribed standards in respect of cyanide
106
It is recommended that the unit may be directed to
install flow meter at effluent treatment plant and
maintain proper records of effluent treatment.
At the time of inspection ETP was not in operation. therefore ETP outlet sample was not
Sukrati Viddut Udyog Pvt.Ltd., Electrical & It is recommended that unit may be directed to acquire
243 5.3.2018 drawn.ETP was found non-operational.
D-39, Meerut Road Gzb. Electronics valid authorisation to dispose off the ETP sludge and
Authorization under Hazardous and other Waste was not available.
other Hazardous waste in a proper scientific way.
It is recommended that unit may be re-inspected for
checking the ETP performance when it is in operation.
It is recommended that unit may be directed to close its
Electroplating, Based on analysis result of final ETP discharged, out of 14 parameters 7 parameters (TSS, operations till its takes necessary steps to improve the
Techno Enterprises,
244 9.3.2018 Phosphating & COD, BOD, T. Cr, Copper, Iron, O/G) are not compliance as treated effluent standards as efficiency of Effluent treatent plant so that treated
A-13/12 Meerut Road Gzb.
Galvanizing per CPCB Guidelines effluent shall comply with the prescribed standards in
respect of TSS, COD, BOD, Cr, Cu, Fe, O/G.
It is recommended that unit may be directed to acquire
valid authorization to dispose off the ETP sludge and
Based on the Analysis result of final ETP discharged out of 14 parameters 07 parameter
other Hazardous Waste in a proper scientific way.
Electroplating, (TSS, Cr+6 , CN, Cd, Cu, Ni, Pb) were found within limit and remaining 07 parameters (pH,
Ultra Electroplaters, It is recommended that unit may be directed to close its
245 9.3.2018 Phosphating & COD, BOD, Cr, Fe, Zn, Oil and Grease) are not compliance as treated effluent standards as
46 Meerut Road Gzb. operations till it takes necessary steps to improve the
Galvanizing per CPCB Guidelines
efficiency of Effluent treatment Plant so that treated
Industry was running without authorization from 20.11.2015 till date
effluent shall comply with the prescribed standards in
respect of 07 parameter (pH, COD, BOD, Cr, Fe, Zn, O/G)
It is recommended that unit may be directed to acquire
valid authorization to dispose off the ETP sludge and
Based on the Analysis result of final ETP discharged out of 5 parameters 4 parameter (pH,
other hazardous Waste in a proper scientific way. It is
TSS, COD, Oil and Grease) were found within limit and 1 parameter (BOD) was exceeding
246 Unichem Laboratories, C-31, Meerut Road Gzb. 5.3.2018 Pharmaceutical recommended that unit may be directed to take
with the prescribed standard of pharmaceutical final ETP outlet discharge. Industry was
necessary steps to improve the efficiency of Effluent
running without authorization from August 8, 2015 to till date.
Treatment Plant so that treated effluent shall comply
with the prescribed standards in respect of BOD
1. Maintain the use of water Record Register on daily-
basis.
Uttam Toyata, 1. Oil & Grease parameter conc.11 mg/L exceed from acceptable Standard limit 10mg/L. 2. Install Continuous Online Emission Monitoring
247 8.3.2018 Others
A-11, Meerut Road Ind Area Gzb. 2. Daily Log-Book (Electromagnetic Flow meter) Water consumption not maintained System (COEMS) at the outlet of ETP.
3. Industry may be asked to control Oil & Grease in
discharged by improving the treatment System.
1. Install Continuous Online Emission Monitoring System
1. Heavy Metal Fe conc.13.61mg/L exceed from acceptable Standard limit 5mg/L &Zn (COEMS) at the outlet of ETP.
conc.8.87mg/L exceed from acceptable Standard limit 5mg/L. 2. Electromagnetic Flow meter installed for water
Zeeta Ind.Corporation Ltd., Electrical &
248 8.3.2018 2. Electromagnetic Flow meter not installed for water consumption. consumption and maintain Log-Book for daily uses..
B-8, Meerut Road Gzb. Electronics
3. In Ground Water Sample Fe conc. 21.81mg/L exceeded for acceptable Standard limit 3. Industrymay be asked to control Heavy Metal Fe & Zn
3mg/L. in discharged by improving the treatment System.
N.G. Textile Prints P.Ltd., Industry running without validity of Consent under Water Act, 1974( up to 1. To install OCMES. 2. Issue the Show Cause notice to
249 8.3.2018 Textile & Dyeing
E-13/2, kavinagar ind.area ghaziabad 31.12.2017(Expired) the industry.
107
1. Install Continuous Online Emission Monitoring System
1. Heavy Metal Hg conc.1.06mg/L in effluent and also in Ground Water 1.12mg/L exceed (COEMS) at the outlet of ETP. 2. To maintain Log-Book
N.G. Textiles.,
250 7.3.2018 Textile & Dyeing from acceptable Standard limit 0.01mg/L also in Ground water (Electromagnetic Flow meter) for water consumption.
13A/10, Site-2, Loni Road I.A., Mohan NGR
2. Electromagnetic Flow meter daily LOG-book not maintained. 3. Industry may be asked to control Heavy Metal Hg in
discharged by improving the treatment System
Closed ( Direction Under Section 5 of the Environment
ASHOKA PULP & PAPER PVT. Ltd., 1. The Boiler of the unit was not in operation.
251 6.3.2018 Pulp & Paper Act, 1986 vide order B-23012/1/IPC-III/13986 Dt.20
11, Site-2, Loni Road LA, GZB. 2. The Process unit was found Dry.
Nov.2017)
1. Install Continuous Online Emission Monitoring System
(COEMS) at the outlet of ETP.
Engg., Iron and 1. TSS conc.277 mg/L exceed from acceptable Standard limit 100mg/L also Heavy Metal
Usha Cycle, 2.Industry may be asked to installed Electromagnetic
252 9.3.2018 Steel & Metal Cu conc.3.55mg/L exceed from acceptable Standard limit 3.0mg/L in effluent water
E-9, S.S. of G.T. Road Ind. Area, GZB. Flow meter for water consumption and control Heavy
Industries 2. Electromagnetic Flow meter is not installed.
Metal Cu in discharged by improving the treatment
System
Engg., Iron and Industry is meeting the norms however, unit may be
M/s Sheetal industries, Unit was operational at the time of visit. ETP was in operation. Manpower 10-12 workers.
253 06.03.2018 Steel & Metal asked for better housekeeping and safety measures, in
s-40, south sidecind area G.T Road Ghazibad, dated Very less space to move, poor management.
Industries case of any accident.
Unit was made operational at the time of visit due to some minor maintenance work. ETP
Electroplating,
M/s Shivam Febrication P Ltd., was just operated at the time of visit, due to maintenance in one unit (as told by unit Unit is partially meeting the norms; hence unit may be
254 07.03.2018 Phosphating &
22/9, S.S. of G.T. Road Ind. Area, GZB. manager- fresh sludge was also seen) hence it was not stabilized at the time of sampling, asked for proper operation of ETP.
Galvanizing
however sample was taken. Housekeeping was satisfactory. Manpower 10-12 workers
Engg., Iron and Unit is meeting the norms however unit may asked for
M/s Silvirite Spokes Pvt. Ltd. S-28, S.S. of G.T. Road Unit was operational at the time of visit. ETP was in operation. manpower 4-5 workers.
255 07.03.2018 Steel & Metal improvement in treatment process and disposal of
Ind. Area, GZB. Manual work of zinc plating
Industries treated effluent.
Engg., Iron and
M/s Cosmos Engineering components, Unit was operational at the time of vist. No effluent generation only dry process. Good Unit need to keep record of iron scrap generated & sold
256 05.03.2018 Steel & Metal
A- 7/79, South side Ind area G.T Road, Ghaziabad house keeping. to recyclers
Industries
The unit was operating ETP which partially meeting the
Unit was operational at the time of visit. ETP was in operation & treated effluent recycled.
Engg., Iron and norms, hence improvement in treatment process is
M/s Tarun International (P) Ltd., No effluent was going out at the time of inspection. Rain water harvesting system in
257 05.03.2018 Steel & Metal necessary.
C-15 South Side Ind. Area G.T. Road , Ghaziabad operation installed capacity 40000 lit tank capacity for 21mX130m covered area +open
Industries Industry is having lot of open area, Plantation on open
area. Good house keeping. Manpower 10-12 workers
area is necessary.
Unit is partially meeting the norms (hexa valent
Chromium is exceeding the norms) unit may be asked
for improvement in treatment process. Poor
Unit was operational at the time of visit. ETP was started at the time of visit. Poor housekeeping hence improvement in housekeeping and
M/s Sree Balaji Metals
258 07.03.2018 Others housekeeping. Manpower 15-20 workers. Stack height for flue gases at Furnace was space management is necessary. Safety equipment for
E-17 Kavi Nagar Industrial Area Ghaziabad
inadequate, smoke inside the working area was seen at the time of visit. workers are also necessary in unit. Stack height for flue
gases at Furnace was inadequate smoke inside the
working area was observed hence may be asked for
proper stack height as per norms.
M/s A.C.E. Hardware Pvt Ltd, Electroplating, 1. M/S ACE Hardware pvt. LTD has exceeding the
M/S ACE HARDWARE PVT.LTD. B-5 KAVINAGAR INDUSTRIAL AREA GHAZIABAD, UP HAS
259 B-5, Bulandshahar Road, Industrial Area, 07.03.2018 Phosphating & discharge limit of wastewater with reference to cyanide
DISCHARGED THE WASTEWATER I.E FROM ETP OUTLET TO THE NEARBY drain.
Ghaziabad Galvanizing and Heavy metal (i.e Nickel, Copper and Lead)
108
M/s S.D. Industries, E-124, B.S. Road Industrial Area, Ghaziabad, UP has no sign board fix
Electroplating, in the entry side of the industry. The industry has designed its ETP outlet for discharging
M/s S.D Industries
260 07.03.2018 Phosphating & of wastewater to the common drain. The house keeping of the industry is very poor. Acid
E124, B.S Industrial area, Ghaziabad
Galvanizing fumes are observed inside the factory and workers are working without safety
equipments i.e. acid proof gloves, shoes etc..
M/s N. G. Wash (Formerly named as M/s Apex Udyog), has manufactured denim and non-
denim children and adult garments with a production capacity of 30 TPA. The industrial
activities are included with garment dyeing and washing. The industry has one ETP with a
capacity of 35 KLD. The ETP is working and the final discharge of ETP is met in the M/s N. G. Wash (Formerly named as M/s Apex Udyog), I-
common drain which is covered. The industrial representative has claimed that the 4, Sec D-1, Apparel Park, Tronica City, Loni, Ghaziabad,
M/s N. G. Wash (formerly named as Apex Udyog)
261 04.04.2018 Textile & Dyeing effluent coming from ETP outlet is UP is discharging significant quantity of organic waste to
I-4, Sec-D1, Apparel Park, Tronica City, Ghaziabad
further treated in nearby CETP. But no document, in this context has found from the drain and required further treatment before their
industrial side. The team has collected different waste water samples from the ETP outlet final discharge.
as per the guideline. The flow of the ETP outlet was non-continuous and depends on the
production. The industry has shown valid consent papers on Air, Water and Hazardous
Waste disposal issued by U. P. Pollution Control Board during the visit.
M/s Chacha Enterprises has manufactured Jean garments with a production capacity of
23.6 TPA. The industrial activities are similar to garment dyeing and washing. The industry
has one ETP with a capacity of 25KLD. The ETP was in operation during the visit period. M/s Chacha Enterprises, J-4, Sec D-1 (P-3), Apparel Park,
The final Tronica City, Loni, Ghaziabad, UP has exceeding the
M/s Chacha Enterprises,
262 04.04.2018 Textile & Dyeing discharge of ETP is met in the common drain. The industrial representative has claimed discharge limit of wastewater with reference to pH and
J-4, Sec. D-1(P-3), Apparel Park, Tronica City, Loni.
that the effluent coming from ETP outlet is further treated in nearby CETP. But no BOD. The industry needs further treatment of ETP outlet
document, in this context has found from industrial side. The team has collected different before discharging to the drain.
waste water samples from the ETP outlet as per guideline. The flow of the ETP outlet was
continuous.
M/s D.K. Jain,
The industry was found not in operation during the visit period. The ETP was also not in
263 G-262, Sector D-1(P), Aparels Park, Tronica City, 04.04.2018 Textile & Dyeing
operation. The team could not collect the ETP outlet samples due to the same reason.
Loni, Ghaziabad.
M/s Deepak Gambhir has manufactured children and adult jean garments with a
production capacity of 125 TPA. The industrial activities are included with garment dyeing
and washing industry. The industry has one ETP with a capacity of 70 KLD. The ETP is M/s Deepak Gambhir, E-12, Apparel Park, Sec D-1 (P-3),
working and the final discharge of ETP is met in the common drain which is covered. The Tronica City, Loni, Ghaziabad, UP is exceeding the BOD
M/s Deepak Gambhir, E-12 Apparel Park, Sector D-
264 04.04.2018 Textile & Dyeing representative of the industry has claimed that the effluent discharging from ETP outlet is limit in its ETP outlet discharge. The industry should
1(P3), Tronica City, Loni.
further treated in nearby CETP. But no minimize the organic waste through treatment before
document, in this context has found from industrial side. The team has collected different the final discharge.
wastewater samples from the ETP outlet as per the guideline. The flow of the ETP outlet
was non- continuous and depends on the production.
All physicochemical parameters are not meeting the
M/s Denim Matching,
265 09.03.2018 Textile & Dyeing standards as stimulated in the consent. Industry have
G-141, Apparel Park Tronica City, Ghaziabad
to take necessary to mitigate pollution level.
M/s Durgeshwari Garments Pvt. Ltd., Quality of effluent was found within limit. ETP was
System was working properly during visit. As per results, meeting
266 E-13, Sector -13-1, Appral Park, Tronica City, Loni 08.03.2018 Textile & Dyeing working
the standards.
Ghaziabad properly during visit.
109
Quality of effluent was found within limit. But ETP was
not working Due to failure of Pump.State Pollution
Control Board may ensure the proper operation and
M/s Ekansh Textile treatment of trade
ETP was not properly worked during visit but after 1 hr. of operation
267 K-36, Sec-D (1) Appreal Park Tronica City, Loni, 09.03.2018 Textile & Dyeing effluent as per consent to operate. Industry not
system was working.
Ghaziabad analysing the outlet sample to insure the quality of
discharge effluent. Composite sampling may also give
the quality of conclusive idea in terms of trade effluent
treatment.
M/s Excellents Apparels Pvt. Ltd.,
268 K-52, Sect. D-1(P3), Apparels Park, Tronica City. 09.03.2018 Textile & Dyeing Closed Closed
Loni Ghaziabad
GhanShyam Textiles,
269 K-19, Sector 13- 1 (P), Apparels Park, Tronica City, 08.03.2018 Textile & Dyeing Closed Closed
Loni Ghaziabad.
BOD and Cr limit is marginally exceeding as stimulated in
M/s Galaxi Garments, the
270 K-22, Sector D-1, Tronica City, Apparel Park, Loni 08.03.2018 Textile & Dyeing consent. Industry should take care to reduce these
Ghaziabad. values by
taking sincere efforts to treat their effluent properly.
1. The discharge at outlet of the ETP is not complying
M/s Gulshan Rai Jain, 1. Oil and grease is exceeding the acceptable limit 2. Primary ETP was operational 3. with the standards for oil & Grease. The primary treated
271 G-82, Apparel Park, Sector D-1 (P3), Tronica City, 08.03.2018 Textile & Dyeing Installation & operation of continuous online monitoriing system (for pH measurement) effluent is discharged to CETP 2. The industry may be
Loni, at the outlet of ETP was working 4. Outlet of ETP connected to CETP through drain asked to control the Oil & Grease content in discharge
by improving the treatment syste installed.
J.B.S. Processors, The Industry was closed during the visit on two days, 06/03/2018 & 08/03/2018 and the
The industry was closed during the visit, so they may be
272 G-I04, Apparel Park, Sector D-1 (P3), Tronica City, 08.03.2018 Textile & Dyeing reinstallation is going on. Concerned officials was not available for obtaining the required
asked to remain closed before estarting the oerations
Loni, Gzb. information
1. The industry was not in operation during the visit on two days, 06/03/2018 &
The Industry was not in operation during the visit, so
Jai Mata Di Dyers, 08/03/2018 2. As the industry was not in operation, the ETP was also not functional and
273 08.03.2018 Textile & Dyeing they may be asked to remain closed for further periods
1-9, Sect. D-1(P3), Tronica City, Loni. no sample was collected 3. Valid authorisation under Hazardous and other Waste
and inform U.P. State Board and CPCB
(M&TM) Rules, 2016 was not made available at the time of visit.
Jai Shri Dyeing, 1. All the parameters are within the acceptable lmits. 2. ETP was in operation 3. No
274 1-21, Apparel Park, Sector D-1(P3). Tronica City, 08.03.2018 Textile & Dyeing Continuous Online Emission Monitoring system at the outlet of ETP 4. Outlet of ETP The industry is complying the EPA standards
Loni. connected to CETP through open channel
1. The discharge at outlet of the ETP is not complying
1. Valid authorisation under Hazardous and Other Waste (M&TM) Rules, 2016 was not
with the standards for TSS. The primary treated effluent
available and showed the copy of application made on 10.03.2018 for renewal.
is discharged to CETP.
2. TSS is exceeding the acceptable limit.
2. The industry may be asked to control the TSS content
Laxmi Bleach,
in discharge by improving the treatment system
275 D-102, Sec D-1(P3),Apparel Park, Tronica City, Loni, 08.03.2018 Textile & Dyeing 3. Primary ETP was in operation.
installed.
Ghaziabad.
4. Continuous Online Emission Monitoring system (for pH measurement) installed at the
3. State Pollution Control Board may ensure the issuance
Outlet of ETP.
of grant of authorisation under Hazardous and Other
Waste (M&TM) Rules, 2016 with respect to their
5. Outlet of ETP connected to CETP through drain.
application made on 10.03.2018 for renewal.
110
1. The industry was not in operation during the visit on two days, 06/03/2018 &
08/03/2018 due to some maintenance work 2. As the industry was not in operation, The The Industry was not in operation during the visit, so
Laxmi Processors,
276 08.03.2018 Textile & Dyeing ETP was also not functional and no sample was colleceted 3. Valid authorisation under they may be asked to remain closed for further periods
K-16, Sect-D-1, Pocket-3, Appral Park, Tronica city
Hazardous and other Waste (M&TM) Rules, 2016 was not made available at the time of and inform U.P. State Board and CPCB
visit.
1. As per the analysis report the parameters pH, BOD,phenol, oil &grease are complying
M.S. Trading,
the standards. 2. TSS is exceeding the permissible limits 3. ETP was operational 4. Industry may be asked to control TSS in discharge by
277 E-15, Sector D-1(P), Aparels Park, Troniea City, 08.03.2018 Textile & Dyeing
Installation and operation of Continuous Online Emission Monitoring system at the outlet improving the treatment system installed
Loni.
of ETP was not installed 5. Outlet of ETP connected to CETP through open channel
1. Oil and grease is exceeding the aceptable limits 2. ETP was operational 3. Continuous
Nandi Enterprises, Industry may be asked to control oil and grease in
278 08.03.2018 Textile & Dyeing Online Emission Monitoring system at the outlet of ETP was not installed 4. outlet of ETP
J-15. See D-1(P3), Apparel Park, Tronica City, tent, discharge by improving the treatment system installed
connected to CETP through open channel
Nandi Enterprises, Industry may be asked to control TSS and oil & grease in
1. TSS and Oil & Grease are exceeding the acceptable limits 2. ETP was operational 3.
279 K-14, Apparel Park, Sector D-1 (P3), Tronica City, 08.03.2018 Textile & Dyeing discharge in discharge by improving the treatment
Continuous Online Emission Monitoring system at the outlet of ETP was not installed
Loni, system installed
National Industries, 1. pH is below the acceptable limit 2. ETP was operational 3. Electromagntic flow meter
Industry may be asked to control pH in discharge by
280 G-264, Apparel Park, Sector D-1(P3). Tronica City, 08.03.2018 Textile & Dyeing was not in operation 4. Continuous Online Emission Monitoring system at the outlet pf
improving the treatment system installed
Gzb. ETP was not installed 5. Flow diagram of ETP was not Provided
Om Prakash Sharma,
1. BOD and TSS are exceeding the acceptable limits 2. ETP was operational 3. Continuous Industry may be asked to control TSS and BOD in
281 J-11, Apparel Park. Sector D-1(P3). Tronica City, 08.03.2018 Textile & Dyeing
Online Emission Monitoring system 4. Flow Diagram of ETP was not provided discharge by improving the treatment system installed
Ghaztabad
Pooja Pahawa, 1. pH is below the acceptable limit 2.Oil & Grease is exceeding the limit 3. ETP was
Industry may be asked to control pH and Oil and grease
282 K-11, Apparel Park, Sector D-1(P3), Tronica City, 08.03.2018 Textile & Dyeing operational 3. Continuous Online Emission Monitoring system at the outlet pf ETP was
in discharge by improving the treatment system installed
Loni. not installed 5. Flow diagram of ETP was not Provided
Adunik Dyeing formally known as Puran Munjal, H-
283 12. Sector D-1(P), Aparels Park, Tronica City, 06.03.2018 Textile & Dyeing Not Mention Not Mention
Loni,Ghazlabad
Quadri Processors, I-8, See D- 1(P3),.Apparel Park,
284 09.03.2018 Textile & Dyeing Not Mention Not Mention
Tronica City,
During joint inspection team no-48 has been collected the sample from Effluent
R.R. Impex
Treatment Plant outlet from M/s RR Implex G-261, Sector D-1, Tronica city, Loni,
285 G-261, Sect. D-1 (P) Aparels Park Tronica City Loni, 07.03.2018 Textile & Dyeing Not Mention
Ghaziabad, U.P. on dated 07.03.2018. All parameters are of industrial outlet has been
GZB.
found within a limit according to analytical report.
Rachita Processors,
286 K-33 & K-34. Sect. D1, Apparel Park, Tronica City. 07.03.2018 Textile & Dyeing Not Mention Not Mention
Loni,Gzb
Ragging Sons
287 06.03.2018 Textile & Dyeing Not Mention Not Mention
I-13,Sect D -1 (P3) , Tronical City Loni Gzb.
Rajeev Kumar,
288 07.03.2018 Textile & Dyeing Not Mention Not Mention
G-64, See D-1 (P3). Apparel Park, Tronica City, Loni,
Robust Infra Tech P Ltd.,
1. ETP is Non operational, 2. Continuous Online Monitoring system at the Outlet of ETP 1. Industry not operating due to weekly off, no action
289 J-13, Apparel Park, Sector D-1(P3), Tronica City, 06-03-2018 Textile & Dyeing
was not installed. 3. Outlet of ETP connected to CETP through Open drain. required.
_Lord. Ghaziabad.
Roop Trading Company, 1. ETP is operational, as per the consent the unit has to maintain the pH 5.5-9.0 and
1. Industry not complying with norms . 2. Housekeeping
290 E-14, sect-D- 1, pocket-3, Appral Park, Tronica city, 06-03-2018 Textile & Dyeing discharge its effluent to CETP 2. Continuous Online Monitoring system at the Outlet of
of the ETP may be improved
loni, Ghaziabad. ETP was not installed. 3. Outlet of ETP connected to CETP throughOpen drain.
111
Roop Trading Company, 1 The unit has shifted its operation and not doing any work of dyeing ,bleaching etc. 2)
Unit has seized its dyeing operation only embroidery and
291 K-9, sect-D-1, pocket-3, Appral Park, Tronica city, 06-03-2018 Others Unit jas informed vide letter dated 10 sept 2015 to UPPCB regarding its change in its
stitching is done, no action required
Loni haziabad. operation. Consent to operate earlier granted by UPPCB for dyeing and washing.
Royal Techno Dyers,
292 K-47, Apparel Park, Sector D-1(P3), Tronica City, 08-03-2018 Textile & Dyeing Industry was closed since one year Industry is closed
Loni. Ghaziabad.
S.D. Garments,
293 1-2, Sector-D-1, pocket 3, Appral Park, Tronica city, 06-03-2018 Textile & Dyeing Not in Operation Not in Operation
Loni, Ghaziabad.
1. Continuous Online Monitoring system at the Outlet of ETP was not installed. 2. ETP is
S.T. Traders,
operational, as per the consent the unit has to maintain the pH 5.5-9.0 and discharge its
294 J-5, sector d-1 , Apparel park, Tronica city , Loni, 06-03-2018 Textile & Dyeing Industry not complying with the consent norms.
effluent to CETP
Ghaziabad
3. Outlet of ETP connected to CETP throughOpen drain.
1. The unit was inspected on 09.03.2018 and was found operational.
As per the sample analysis report, the unit is discharging
2. The unit was engaged in dyeing and washing operations.
effluent water having TSS 419 mg/l and BOD 181 mg/l,
3. The unit has valid consent to operate under Air and Water Act, however, authorization
S.V.S. Fashion, which is higher than the prescribed limit as mentioned
under Hazardous and Other Waste (M&TM) Rules, 2016 was not provided by the unit.
295 J-22, Apparel Park, Sector D-1(P3), Tronica City, 09-03-2018 Textile & Dyeing under consent to operate issued under Water Act by
4. Record of water consumption and waste water generation was not provided by the
Loni, Ghaziabad. UPPCB as 100 and 30 mg/l respectively. Therefore, a
unit during the inspection visit.
show-cause notice u/s 5 of EPA, 1986 may be issued to
5. The unit has installed effluent treatment plant, which was found operational during
the unit.
visit.
Sai Saran Garment,
The unit was inspected on 07.03.2018 and was found
296 G-108, Apparel Park, Sector D-1(P3), Tronica City, 07-03-2018 Textile & Dyeing The unit was inspected on 07.03.2018 and was found closed.
closed.
Loni. ghaziabad
1. The unit was inspected on 09.03.2018 and was found operational during visit.
2. The unit was engaged in dyeing and washing operations.
3. The unit has valid consent to operate under Air and Water Act.
Sandeep Tyagi, 4. Unit has applied for renewal of authorization under Hazardous and Other Waste As per the sample analysis report, the unit is complying
297 G-271, Sec D-1(P3), Apparel Park, Tronica City, 09-03-2018 Textile & Dyeing (M&TM) Rules, 2016. with the prescribed standards for effluent discharge.
Loni, Ghaziabad. 5. Record of water consumption and waste water generation was not provided by the Therefore, no further action is required.
unit during the inspection visit.
6. The unit has installed effluent treatment plant, which was found operational during
visit.
1. The unit was inspected on 07.03.2018 and was found non-operational during visit.
M/s Krish Garments (Sanjeev Kumar), 2. The unit was engaged in dyeing and washing operations. 1. Show cause notice u/s 5 of EPA, 1986 may be issued
298 G-109, Sec D-1(P3), Apparel Park, Tronica City, 07-03-2018 Textile & Dyeing 3. The unit has valid consent to operate under Air and Water Act. to the unit for improper management of hazardous
Loni, Ghaziabad. 4. Authorization under Hazardous and Other Waste (M&TM) Rules, 2016 provided by the waste.
unit was found expired-01.09.2017.
1. The unit was inspected on 09.03.2018 and was found operational during visit.
2. The unit was engaged in dyeing and washing operations.
1. As per the sample analysis report, the unit is
Sara International, G-65, Apparel Park, Sector D- 3. The unit has valid consent to operate under Air and Water Act, however, authorization
299 07-03-2018 Textile & Dyeing complying with the prescribed standards for effluent
1(P3), Tronica City, Loni. Ghaziabad, under Hazardous and Other Waste (M&TM) Rules, 2016 was not provided by the unit.
discharge. Therefore, no further action is required.
4. The unit has installed effluent treatment plant, which was found operational during
visit.
112
1. The unit was inspected on 07.03.2018 and was found non-operational during visit.
Shafali Dyeing, 2. The unit was engaged in dyeing and washing operations. 1. Show cause notice u/s 5 of EPA, 1986 may be issued
300 G-84, Sector D-1(P), Aparels Park, Tronica City, 07-03-2018 Textile & Dyeing 3. The unit has valid consent to operate under Air and Water Act. to the unit for improper management of hazardous
Loni. Ghaziabad 4. Authorization under Hazardous and Other Waste (M&TM) Rules, 2016 provided by the waste.
unit was found expired.
Shallu Prints,
Unit is closed temporarily. However the unit shall not be
301 G-121, Apparel Park, Sector D-1(P3), Tronica City, 07-03-2018 Textile & Dyeing Unit is closed from past 15 months as informed by owner.
allowed to operate until the valid CTO is obtained.
Loni, Ghaziabad.
Shri Paras coloration (U.B. Dyeing), Functioning of CETP in the cluster shall be ensured at all
302 G- 117, Sector d-1(P), Aparels Park, Tronica City, 06-03-2018 Textile & Dyeing PETP closed so no outlet samples taken for lab analysis time so that PETP treatment is sufficient. Inlet norms to
Loni, Ghaziabad. CETP shall be ensured.
Siddhi Vinyak Tex, 1) 'Poorly maintained ETP discharged seen very near to ETP itself. 2) Document
303 H-11, Apparel Park, Sector D-1(P3), Tronica City, 07-03-2018 Textile & Dyeing authorizing withdrawal of ground water, from GWA not found. Housekeeping
Loni, Ghaziabad. satisfactory.
Siddhi Vinyak,
Functioning of ETP and CETP in Loni Industrial Area shall
304 G-103, Apparel Park, Sector D-1(P3), Tronica City, 07-03-2018 Textile & Dyeing Unit closed/ not in operation due to maintenance work in CETP pipeline
be ensured to function at all times.
Loni, Ghaziabad.
Sudhir KumarJain,
PETP functioning with proper house keeping near it shall
305 G-80, Apparel Park, Sector D-1(P3), Tronica City, 07-03-2018 Textile & Dyeing Poorly maintained ETP discharge seen very near to ETP itself.
be ensured all time
Loni.
Sumer Mal (R.K. Export & Import), Unit operating without valid consent papers with the
306 H- 13, Apparel Park, Sector D-1(P3), Tronica City. 06-03-2018 Textile & Dyeing The unit was closed due to roaster imposed by the Loni Industrial Association` unit operator/manager Housekeeping was found not
Loni. satisfactory
M/s Sun Dyers, I-19, Apparel Park, Sector D-1(P3),
307 09.04.2018 Textile & Dyeing Not Applicable Not Applicable
Tronica City, Loni.
Authorization for Hazardous waste is expired on 01.04.2018 and same has been applied
by M/s Supreme Industry. ETP was started operation at the time of Inspection. All
Authorization of renewal Hazardous waste may be
M/s Supreme Industries, Parameters for Physico- Chemical & Heavy Metals of ETP Outlet are meeting to the
308 09.04.2018 Textile & Dyeing checked by UPPCB. Regular functioning & operation of
J-2, Appral Park, tronca city, Loni. Criteria for Industry Specific Standards for Waste Water Discharge in Dye & Dye
ETP should be ensured.
Intermediate – Environment (Protection) Rules, 1986, 2010 except slight exceedance in
pH.
Operational Status of Industrial Unit may be checked.
M/s Tiwari Feb, Water logging outside the Industrial Unit during Inspection. Authorization for Hazardous
Regular functioning & operation of ETP should be
309 G-255, Apparel Park, Sector D-1(P3), Tronica City, 09.04.2018 Textile & Dyeing waste is expired on 04.03.2018 and same has been applied by M/s Tiwari Fab. ETP Sludge
ensured. Authorization of renewal of Hazardous waste
Loni. Stored and send to Bharat Oil & Waste Management
may be obtained by the unit.
Vaishali Hosiery, THE UNIT WAS OPERATIONAL ON THE DATE OF VISIT. 2) The PETP was operational on The unit should maintain log book for fresh water
310 1-17, Sector D-1, Apparel Park, Tronica City, Loni, 19.04.2018 Textile & Dyeing the date of visit 3) The online ffluent monitoring system(OCEMS) not installed 4) The log consumption 2) The anaysis results indicate that unit is
Gzb. book for fresh water consumption not maintained by the unit. no complying as per discharge standards.
Vedanta Estate, THE UNIT WAS OPERATIONAL ON THE DATE OF VISIT. 2) The PETP was operational on The unit should maintain log book for fresh water
311 I-11, Apparel Park, Sector D-1(P3), Tronica City, 19.04.2018 Textile & Dyeing the date of visit 3) The online ffluent monitoring system(OCEMS) not installed 4) The log consumption 2) The anaysis results indicate that unit is
Loni. Gzb. book for fresh water consumption not maintained by the unit. no complying as per discharge standards.
Vedanta Estate,
312 I-12, Apparel Park, Sector D-1(P3), Tronica City, 19.04.2018 Textile & Dyeing The unit was not in operation on day of visit
Loni. Gzb.
113
M/s Vedanta Estate,
313 J-12, Apparel Park, Sector D-1(P3), Tronica City, 08.03.2018 Textile & Dyeing Not Mention Not Mention
Loni.
M/s U-Like Industry, Electroplating,
314 G-110, Apparel Park, Sector D-1(P3), Tronica City, 08.03.2018 Phosphating & Not Mention Not Mention
Loni. Galvanizing
M/s Spectrum Dye Studio Formerly known as
315 M/s Tusar Garments, J-3, Apparel Park, Sector D- 08.03.2018 Textile & Dyeing Not Mention Not Mention
1(P3), Tronica City, Loni Ghaziabad
M/s Pradeep Kumar,
316 G-92, Apparel Park, Sector D-1(P3), Tronica City, 08.03.2018 Textile & Dyeing Closed Closed
Loni.
No electromagnetic flow meters were installed; however ultrasonic flow meters were
installed and were found operational.
Ground water sample collected near M/s Silvertone (Unit I & II) and M/s Garg Duplex
M/s Silvertone Paper Ltd. (unit II)
317 16.04.2018 Pulp & Paper (P) Ltd., were not complying w.r.t Sulphate.
Bhopa Road, Muzaffarnagar
No record was being maintained for disposal of coarse screen reject (plastic &
metallic) after the pulper section and also in the hill screen of the ETP inlet.
Housekeeping was very poor in the entire processing area of paper and pulp unit.
114
Annexure-XIV
List of non-complying industries with respect to effluent discharge norms (Corrected)
Sulphate (mg/l)
Sulphide (mg/l)
Fluoride (mg/l)
PHENOL (mg/l)
Cyanide (mg/l)
Total Cr (mg/l)
NH3-N (mg/l)
O & G (mg/l)
(µmhos/cm)
Compliance
BOD (mg/l)
COD (mg/l)
Phosphate
TDS (mg/l)
TSS (mg/l)
Mn (mg/l)
Sb (mg/l)
Cd (mg/l)
Cu (mg/l)
Pb (mg/l)
Co (mg/l)
Zn (mg/l)
Fe (mg/l)
Ni (mg/l)
Hg (µg/l)
Cl (mg/l)
Cond in
(mg/l)
Status
Industry
Na %
6
pH
Cr +
Industry Name and Address
S.No
115
Sulphate (mg/l)
Sulphide (mg/l)
Fluoride (mg/l)
PHENOL (mg/l)
Cyanide (mg/l)
Total Cr (mg/l)
NH3-N (mg/l)
O & G (mg/l)
(µmhos/cm)
Compliance
BOD (mg/l)
COD (mg/l)
Phosphate
TDS (mg/l)
TSS (mg/l)
Mn (mg/l)
Sb (mg/l)
Cd (mg/l)
Cu (mg/l)
Pb (mg/l)
Co (mg/l)
Zn (mg/l)
Fe (mg/l)
Ni (mg/l)
Hg (µg/l)
Cl (mg/l)
Cond in
(mg/l)
Status
Industry
Na %
6
pH
Cr +
Industry Name and Address
S.No
116
Sulphate (mg/l)
Sulphide (mg/l)
Fluoride (mg/l)
PHENOL (mg/l)
Cyanide (mg/l)
Total Cr (mg/l)
NH3-N (mg/l)
O & G (mg/l)
(µmhos/cm)
Compliance
BOD (mg/l)
COD (mg/l)
Phosphate
TDS (mg/l)
TSS (mg/l)
Mn (mg/l)
Sb (mg/l)
Cd (mg/l)
Cu (mg/l)
Pb (mg/l)
Co (mg/l)
Zn (mg/l)
Fe (mg/l)
Ni (mg/l)
Hg (µg/l)
Cl (mg/l)
Cond in
(mg/l)
Status
Industry
Na %
6
pH
Cr +
Industry Name and Address
S.No
117
Sulphate (mg/l)
Sulphide (mg/l)
Fluoride (mg/l)
PHENOL (mg/l)
Cyanide (mg/l)
Total Cr (mg/l)
NH3-N (mg/l)
O & G (mg/l)
(µmhos/cm)
Compliance
BOD (mg/l)
COD (mg/l)
Phosphate
TDS (mg/l)
TSS (mg/l)
Mn (mg/l)
Sb (mg/l)
Cd (mg/l)
Cu (mg/l)
Pb (mg/l)
Co (mg/l)
Zn (mg/l)
Fe (mg/l)
Ni (mg/l)
Hg (µg/l)
Cl (mg/l)
Cond in
(mg/l)
Status
Industry
Na %
6
pH
Cr +
Industry Name and Address
S.No
118
Sulphate (mg/l)
Sulphide (mg/l)
Fluoride (mg/l)
PHENOL (mg/l)
Cyanide (mg/l)
Total Cr (mg/l)
NH3-N (mg/l)
O & G (mg/l)
(µmhos/cm)
Compliance
BOD (mg/l)
COD (mg/l)
Phosphate
TDS (mg/l)
TSS (mg/l)
Mn (mg/l)
Sb (mg/l)
Cd (mg/l)
Cu (mg/l)
Pb (mg/l)
Co (mg/l)
Zn (mg/l)
Fe (mg/l)
Ni (mg/l)
Hg (µg/l)
Cl (mg/l)
Cond in
(mg/l)
Status
Industry
Na %
6
pH
Cr +
Industry Name and Address
S.No
119
Sulphate (mg/l)
Sulphide (mg/l)
Fluoride (mg/l)
PHENOL (mg/l)
Cyanide (mg/l)
Total Cr (mg/l)
NH3-N (mg/l)
O & G (mg/l)
(µmhos/cm)
Compliance
BOD (mg/l)
COD (mg/l)
Phosphate
TDS (mg/l)
TSS (mg/l)
Mn (mg/l)
Sb (mg/l)
Cd (mg/l)
Cu (mg/l)
Pb (mg/l)
Co (mg/l)
Zn (mg/l)
Fe (mg/l)
Ni (mg/l)
Hg (µg/l)
Cl (mg/l)
Cond in
(mg/l)
Status
Industry
Na %
6
pH
Cr +
Industry Name and Address
S.No
120
Sulphate (mg/l)
Sulphide (mg/l)
Fluoride (mg/l)
PHENOL (mg/l)
Cyanide (mg/l)
Total Cr (mg/l)
NH3-N (mg/l)
O & G (mg/l)
(µmhos/cm)
Compliance
BOD (mg/l)
COD (mg/l)
Phosphate
TDS (mg/l)
TSS (mg/l)
Mn (mg/l)
Sb (mg/l)
Cd (mg/l)
Cu (mg/l)
Pb (mg/l)
Co (mg/l)
Zn (mg/l)
Fe (mg/l)
Ni (mg/l)
Hg (µg/l)
Cl (mg/l)
Cond in
(mg/l)
Status
Industry
Na %
6
pH
Cr +
Industry Name and Address
S.No
121
Annexure XV
The river Hindon is an intermittent river and originates from lower Shavlik ranges in
District Saharanpur in Uttar Pradesh. During non-monsoon, the river is dry on
upstream of Saharanpur and carries no water in it. Flow in the river starts with
discharge of municipal sewage and trade effluents from Saharanpur onwards. The
river Kali (West) and Krishni are the tributaries of river Hindon. Both the tributaries also
carry sewage and industrial effluents. Figure P1 shows the river Hindon and its
trirbutaries as well as various drains contributing pollution load in river Hindon.
Figure P1. River Hindon and its tributaries River Kali (West) and Krishhi as well
as drains contributing pollution load in river Hindon
122
2. Water Quality Goals
It is an important aspect for revival of river Hindon in context of its utility as it is non-
perennial River. The ultimate goal for beneficial use of river will determine the level of
actions to be taken for maintaining the water quality. Under the present circumstances,
it appears that river Hindon may serve the purpose of irrigation and for this objective,
generated municipal sewage should be treated to meet the irrigation standards. Also,
the industrial effluents generated from the catchment of river Hindon which are
ultimately joining and contributing to the pollution load in river Hindon should be
treated to meet the effluent discharge standards stipulated under Schedule-VI of the
Environment (Protection) Rules, 1986 which is given as Annexure-PI.
The requirement of river water quality for wild life and fish propagation also requires
more stringent conditions and river water quality has to maintain adequate Dissolved
Oxygen (DO) content so as to support survival of fish and other aquatic life.
Comparative suggested criteria for Irrigation, wild life and survival of fish life in river
Hindon is given in the following Table P1.
Table P1. Suggested criteria for Irrigation, wild life and survival of fish life
River Hindon being intermittent river, the action plan for maintaining water quality will
be different from that of the perennial rivers. Presently, the river Hindon and its
tributaries (Kali-West and Krishni) are acting as treated or partially treated wastewater
carrying channels. Therefore, the action plan for prevention and control of pollution of
river Hindon has been drafted based on the following documents:-
(ii) Orders of Hon’ble National Green Tribunal (NGT) (PB) in the matter of M.C.
Mehta Vs Union of India & Others (i.e., Directions for segment ‘A’-Gaumukh to
Haridwar in Uttarakhand, dated 10/12/2015 and Directions for Segment ‘B’
Haridwar Downstream to Kanpur/Unnao in Uttar Pradesh, dated 13/7/2017).
123
4. Components of Action Plan
Source control includes industrial pollution control and treatment and disposal of
domestic sewage as detailed below:-
i) Inventorisation of industries
ii) Categories of industry and effluent quality
iii) Treatment of effluents, compliance with standards and mode of disposal of
effluents
iv) Regulatory regime.
Following are the action plan for rejuvenation of river Hindon as detailed below:
Fourteen (14) Sugar Industries should not be permitted to discharge treated /untreated
effluents in any drain. Treated effluent should be completely utilized for irrigation
purpose. Consent condition accordingly, is modified by UPPCB prior to start of next
crushing season of the sugar industry.
(ii) Distilleries
(a) All the distilleries should operate only with ‘zero liquid discharge’ (ZLD) system.
In no case, spent wash be either disposed in drains or on land.
(b) Molasses generated should be properly stored and no spillages be allowed
during handling.
(c) The composted spent wash after Reverse Osmosis (RO)/ Multiple Effect
Evaporator (MEE), the compost should meet the standards and after ensuring
that the composted material does not leach color only such composted material
may be used for land application.
(a) Fifty six units comprising Pulp and Paper and straw board manufacturing units
should not be permitted to dispose generated effluents in any drain.
(b) Agro-based pulping should be banned or prohibited in the catchment area of
river Hindon and its tributaries.
(c) Pulp and paper units should meet charter criteria as suggested by CPCB.
(d) Sludge being used for making boards and proper records should be maintained
end use of generated sludge and the concerned industry shall ensure that no
over-flow from sludge drying bed occur.
One hundred (100) Textiles units should meet the inland surface wastewaster
discharge norms and these units should also be insisted to reuse treated
effluents in the process to minimize fresh water consumption. To achieve this
UPPCB shall fix specific waste water generation limit to reduce it to atleast half
of the present average value.
(v) Electroplating
(a) Forty six (46) electroplating industries which are the main source of metallic
contamination of surface and ground water and therefore should be insisted for
‘ZLD’ system.
125
(b) All the electroplating units or having electroplating process or industrial
processes which are likely to discharge effluents containing heavy metal or
pollutants that may damage environment, in such cases, U.P.PCB shall make
necessary amendments to the Consents granted under Water (Prevention and
Control of Pollution) Act, 1974 for incorporation of the effluent discharge
standards for all the parameters as prescribed under Environment (Protection)
Act, 1986.
(vi) Tanneries
(a) Six (6) Tanneries should meet the effluent discharge standards of stand-
alone units.
(b) Recovered chrome salt should be used or recycled in the process within
the industry and should minimize chrome consumption.
(c) Standards of Total Dissolved Solids (TDS) should be strictly complied
and accordingly Consent conditions be modified with proper prescription
on mode of disposal of treated effluents.
Eleven Slaughter houses and Frozen meat packaging units and Four Dairy
units should install adequate capacity ETPs and maximize utilization of treated
effluent in the process.
Thermal Power Plant (01) (exclusively for power generation) as well as Captive
Thermal Power Plants in operation should meet the discharge standards
notified under the Environment (Protection) Act, 1986.
(ix) All the industry including remaining 74 no. of Industrial units should have
Consents under Water ( Prevention and Control of Pollution) Act, 1974 and Air
(Prevention and Control of Pollution) Act, 1981 as well as Authorisation under
the Hazardous & Other Waste ( Management & Transboudary Movement)
Rules, 2016 as amended and Consents or Authorisation as applicable should
be granted or renewed only after verification or ensuring adequate systems for
disposal of treated effluents or verification of complinces to the granted
Consents/Authorisation strictly.
(a) UPPCB with the support of U.P State Industrial Development Corporation
(UPSIDC) shall carryout inventory of industries within three months time and all
the industries which are presently in operation without Consents under Water
(Prevention and Control of Pollution) Act, 1974 and Air (Prevention and Control
of Pollution) Act, 1981 as the case may be should be directed by UPPCB to
obtain Consents within three months and failing which action should be taken
by UPPCB for closure of all such industrial units.
126
(b) All the hazardous waste generating industries or the industries covered under
Schedule-I of the Hazardous and Other Waste (Management & Transboundary
Movement) Rules, 2016 as amended, should be directed to obtain authorization
within a month from U.P.PCB and failing which action should be taken by
UPPCB for closure of all such industrial units.
(c) All the red category industries be directed by UPPCB for installation OCEMS at
the outlet of ETPs within three monnths time and thereafter such industries be
directed to take measures for data transfer to the UPPCB and CPCB with
immediate effect.
All the 317 industries should give a declaration (in the form of the affidavit) to
the effect that they do not discharge/inject their industrial effluent into ground
water resources.
(f) Small scale/tiny and service providing units located in urban or semi-urban
limits like Dairies, Auto Service Stations etc., should not be allowed to dispose
wastewater effluents or sludges into drains, thereby ensuring not causing
damages to drains or sewers. Such units should have O & G traps as a
minimum provision.
(h) Based on the inspections conducted in compliance to the Hon’ble NGT (PB)
order dated 16.01.2018, following actions be initiated by UPPCB:-
127
Industries which are to be considered as severely violating the norms (
such as non-availability of ETP or discharging effluent without imparting
any treatment or ETP outlets are not complying to the effluent
discharege norms or industrial units in operation without applying for
Consents under Water (Prevention and Control of Pollution) Act, 1974/
Air (Prevention and Control of Pollution) Act 1981 or in Operation without
Authorization under the Hazardous & Other Waste
( Management & Transboundary Movement) Rules, 2016 as amended)
such units shall be closed with immediate effect till the time such Units
obtain Consents/Authorization from U.P.PCB or takes measures to
install requisite capacity ETP.
The Units which are not complying to the effluent discharge norms due
to poor operation and maintenance of the existing ETP, or require
improvements in such a cases, directions under Section 5 of the
Environment (Protection) Act, 1986 be issued by UPPCB for ensuring
compliance to the discharge norms and carryout necessary
improvements within a period of three months.
Table P2: Towns discharging sewage into River Hindon, Kali (West) and Krishni
128
(ii) Sewage and sullage is being disposed into rivers through 16 drains ( 3 in
Saharanpur, 4 in Muzaffar Nagar, 3 in Meerut, 01 in Bagpat, 2 in Ghaziabad
and 3 in G.B.Nagar.
(iii) Prior to the planning of sewage treatment, the quality of effluent flowing in the
drains joining river Hindon, Kali-West and Krishni has been analyzed and
studied and drain-wise characteristics of effluent is given Table P3. below:
(a) U.P Jal Nigam would undertake measurement of flow of the drains mentioned
in para (iii) above and formulate detailed project report (DPR) for each drain
and corresponding town - within 6 weeks.
(b) The flow in each drain should exclude monsoon flow. Further, any drain if
receiving fresh water from any escape channel etc, should be examined for its
diversion rather than mixing with sewage.
(c) Sewage treatment plants for each town and related drains should be properly
designed with the interception and diversion plan.
(d) Sewage treatment plant (STP) and its design should be based on its full
utilization capacity and ensuring simultaneous house connections to sewers as
applicable to each drain and town.
(e) The design aspect of STP should include sewage utilization plan, instead of
disposal into the drain/river. As directed in Ganga matter ( Segment ’B”), at
least, 75 % sewage should be utilized. For the remining part to be discharged
into river, strict standards of BOD and FC should be followed and complied.
(f) DPRs should be submitted to the National Mission for Clean Ganga (NMCG) for
consideration as a part of Ganga/Yamuna basin management plan. NMCG may
129
decide funding pattern and modal for STP as per their policies. U.P.Jal Nigam
should submit DPR to NMCG by 30.09.2018 and NMCG to convey decision
before 30.11.2019 to U.P. Jal Nigam/State Government of U.P for execution of
projects.
(g) Sewage treatment plan should also consider treatment and disposal of sewage
from Villages/Gram Panchayats /isolated settlements including discharges from
toilets constructed under Swachh Bharat Abhiyan.
(h) As mentioned under para 5.1 (f), dairy waste in particular and the oily
waste/sludge from service stations and similar type of commercial
establishments should not be mixed with the sewer lines and not to be disposed
in drains. A separate plan should be prepared for such activities within six
weeks and executed before 31.12.2018.
The main issue in the present matter relates to contamination of tube wells/hand
pumps affecting the health of the pulic living in the villages. The Hon’ble National
Green Tribunal (PB) Delhi passed directives on 05.11.2015 and 07.09.2016 regarding:
(a) CGWA has filed its report on 26.10.2016 (R-1 p. 1016 to 1033) and a summary
finding is mentioned on page 1020.
(b) Minutes of the meeting held on 21.07.2016 under the Chairmanship of Chief
Secretary, U.P, it has been recorded that a survey of total 154 affected villages
in six districts (i.e., Saharanpur, Muzaffar Nagar, Bagpat, Shamli, Meerut and
Ghaziabad) has got done. Total 4528 hand pumps are installed in the affected
villages out of which potable water is being extracted from 4283 hand pumps
whereas water from 345 hand pumps is polluted. The hand pumps water of
which is polluted have been sealed (Page 849)
(c) The further follow-up on sealing and supply of potable water may be updated by
U.P. Jal Nigam.
130
CPCB after having representative sampling of Ground water, submits the following
actions for consideration:
(a) State Govt. of U.P to comply with the directions of Hon’ble Tribunal dated
05.11.2015, 29.07.2016 and 07.09.2016 regarding supply of potable water and
sealing of contaminated hand pumps with immediate effect.
(b) CGWA and State Depts. to identify over exploited and critical blocks in the six
districts w.r.to the ground water extraction and industries be directed to comply
with CGWA conditions ( As directed by Hon’ble Tribunal in Ganga Matter in
Segment ‘B’.) of granted NOC.
(c) UPPCB should be vigilant and conduct surprise inspection of the industry to
rule out any forceful injection of industrial effluents into groundwater resources .
(e) For preventing further contamination of ground water, actions suggested under
para 5.1 and 5.2 of the action plan relating to industrial and sewage pollution
control may also be considered.
(g) Rain water harvesting of industrial, commercial and other institutions may be
insisted upon by CGWA and groundwater recharging with only clean water be
encouraged by CGWA.
U.P. State Govt. (U.P. State Irrigation Department) should identify /demarcate Flood
Plain Zone and regulate the activities. Such regulations would also cover
(i) Plantation in Flood Plain Zone (FPZ) –By State Forest Department
(ii) Checking encroachments-By District/Local administration
(iii) Prohibition of disposal of municipal and bio-medical waste particularly in drains-
By Local administration;
(iv) State Govt. may notify FPZ - within six months.
(i) River Hindon, Kali (West) and Krishni carrying very thin and lean flow of original
water. River Hindon is dry on the upstream of Saharanpur during non-monsoon
period. At different locations, flow of all the three rivers should be measured
and record maintained by U.P.Jal Nigam.
.
(ii) Fresh water flowing through escape channels/small barrages should be
checked. Good quality of water should not be used for dilution of pollution
131
unless, required degree of treatment is achieved for municipal sewage and
industrial effluents.
It is proposed that action plan for Hindon and its tributaries be monitored by a
Committee to be constituted under the Chairmanship of Chief Secretary, U.P. State
Govt. on six monthly basis whereas, at District/Magistrate Level, District Committee
may monitor on quarterly basis.
6.0. Action Plan- Short Term and Long Term Action and the Identified Authorities for
initiating actions and the time limits for ensuring compliance
Shrot term and long term action plans and the implementing agencies responsible for
execution of the action plans and the time limits are given in Table P 4 as below :-
Table P 3: Proposed Short Term and Long Term Action plan for Rejuvenation of
River Hindon
132
treated effluent is not complying
to the effluent discharge
standards or norms
(e) Action against the red category UPPCB Within a
industries for installation of month
OCEMS and not transferring
data to CPCB and UPPCB
(f) Small scale/tiny and service UPPCB Within a
providing units located in urban month
or semi-urban limits like Dairies,
Auto Service Stations to have a
minimum provision of O & G
traps
(g) Prohibition of Burning of any kind State Govt./District Within a
of waste including agro-residues and Local month
authorities
(h) Directions to all the Industries CPCB Within a
which are observed to be not in month
operation or closed or
temporarily closed to remain
close till further orders from
CPCB.
(i) Estimation of industrial effluent UPSIDC and Within six
generation and the existing UPPCB months
CETP capacity and to arrive gap
between the industrial effluent
generation and the existing
treatment capacity
(j) Channelization of industrial UPSIDC, and Within six
effluents to CETPs for ensuring District /Local months
treatment to comply with the Administration
discharge standards
(h) Identification of suitable site within State Government, Within two
industrial estates, Execution and UPSIDC, and years
Commissioning of Adequate District /Local
Capacity CETPs Administration
II. Sewage Treatment and Disposal Plan
(a) District-wise estimation of total State Government, Within three
sewage generation, existing U.P.Jal Nigam, months
treatment capacities, quantum District /Local
of disposal of sewage presently Administration
through drains and the gaps in
sewage treatment capacity
(b) To undertake measurement of State Government/ Within six
flow of all the drains presently U.P. Irrigation months
contributing pollution load in Department and U.P
river Hindon and to formulate Jal Nigam
detailed project report (DPR) for
each drain and corresponding
town and submission of DPR to
133
NMCG
(c) Proper design, execution of State Government, Within two
STPs with full utilisation capacity U.P Jal Nigam/Local years
Authorities under
the supervision of
the U.P.PCB
(d) Channelization including State Government, Within one
diversion of sewage generated U.P Jal Nigam/Local year after
from household/town Authorities commissioning
ships/villages to sewer lines of STPs
/interception of all the drains
presently carrying sewage and
for ensuring proper treatment
through the upcoming STPs
(e) Ensuring dairy/automobile UPPCB and Local By 31.12.2018
service stations and authorities
Hotels/Restaurants particularly
located on road-side should
have a treatment system and
levy of fine in case found
violations
III Ground water quality
(a) Sealing of contaminated hand State Within two
pumps and found to be unfit for Government/U.P. months
drinking purpose by the public Ground Water
Department and
U.P.Jal Nigam
(b) Supply of potable water to the UP Jal Nigam and
affected communities in the U.P. Ground Water
identified critical blocks Department
-- OO --
135
Annexure-PI
137
Annexure-PII
138