CIRCUIT DESCRIPTION
The ECM memory contains the shift programs for the NORMAL and POWER patterns, 2 position, L position
and the lock–up patterns. Following the programs corresponding to the signals from the pattern select
switch, the park/neutral position and other various sensors, the ECM switches the solenoid valves ON and
OFF, and controls the transmission gear change and the lock–up clutch operation.
WIRING DIAGRAM
3RZ–FE
Battery IE IG
D12259
D00751
5VZ–FE
20 3F
J/B
W No. 3
16 3F
R/B No. 2
ALT AM1
W W–B
2 2
2 1 1 2
W–B W–B
Battery
IE IG
D12210
INSPECTION PROCEDURE
D12211
NG
PREPARATION:
3 2
Disconnect the pattern select switch connector.
CHECK:
Check continuity between terminals 2 and 3 of pattern select
switch connector when the select switch is set to PWR and
NORM positions.
OK:
Pattern select switch Specified condition
Q08286
PWR Continuity
NORM No continuity
OK
3 Check harness and connector between battery and pattern select switch, pattern
select switch and ECM (See page IN–28).
OK