CONTROL I/O Terminals
RS-232C/TELNET Protocol Specifications
Ver. 1.11
July 2017
TEAC Corporation
-1-
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
CAUTION
TEAC Corporation (hereafter, "TEAC") permits the use of the protocol described in this specification document with the
prerequisite that the customer consents to the following protocol use agreement conditions.
If you do not consent to the following conditions in the protocol use agreement, you may not use this protocol and should
return this document to TEAC. Moreover, be aware that violations of any of the following items in the protocol use
agreement is an infringement on the rights of TEAC and could result in the termination of further use and be subject to
restitution claims, for example.
1. This agreement comes into effect from the time the customer starts use of this protocol.
2. TEAC grants a nonexclusive and nontransferable "usage" right to the customer in order to develop devices (including
software) that are compatible with the covered TASCAM products.
3. The acquisition of this document by the customer does not mean that the customer has acquired any rights,
titles or interests in this protocol other than what is specified in this use agreement. The customer should
recognize that as a written work belonging to TEAC, this document is protected based on the copyright laws
of the signatory nations of the Universal Copyright Convention and the Berne Convention for the Protection
of Literary and Artistic Works. Without exception, the intellectual property in this protocol belongs to TEAC or
a source that provides it to TEAC.
4. (1) The customer may not make copies of this specifications document.
(2) The customer may not transfer this specifications document to a third party without obtaining prior permission from
TEAC.
(3) Since confidential information that belongs to TEAC is contained in this specifications document, the customer may
not disclose it to a third party without obtaining prior permission from TEAC.
5. This specifications document and this protocol are provided as is. TEAC does not provide any guarantee whatsoever that
the contents of this specifications document and the protocol are suitable for the specific purpose of the customer or
that they are free of error.
6. TEAC cannot respond to customer inquiries about the contents of this specifications document.
7. TEAC will bear no responsibility for any damages (including business losses, business interruption, loss of
business data or other financial damages) arising from the use or inability to use this specifications document
or this protocol. This applies even if TEAC is informed about the potential for such damage in advance.
-2-
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Overview
The SS-CDR250N/SS-R250N (“controlled device”) can be controlled from an external device (“external
controller”), such as a computer, through a serial RS-232C and ETHERNET (TELNET) connection.
1. Specifications
Serial RS-232C
2.1. Electrical Specifications
2. Standard JIS X-5101 (equivalent to the former JIS-C-6361 and EIA RS-232C
standards)
Note that this is not compatible with the RS-422 used in professional VTRs.
Impedance at receiver When measured with an applied voltage between -3 V and +3 V or between
-15 V and +15 V, the DC resistance is between 3 k ohms and 7 k ohms.
Total load capacitance is 2500 pF or less.
Open circuit voltage at transmitter 25V or less
Open circuit voltage at receiver 2V or less
Signal voltage When the open circuit voltage at the receiver is 0 V, the signal voltage is
between -5 V and +5 V or between -15 V and +15V against a load
impedance between 3 k ohms and 7 k ohms.
Signal discrimination Logic “1”: -3V or less
Logic “0”: +3V or more
-3-
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
RXD RXD
2
TXD TXD
3
9
GND GND
5
7 External controller
8
9
+12V Power
9
(For RC-SS150) 9
Controlled device
(SS-CDR250N/SS-R250N)
-4-
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Command Format
2.4. Command Format Overview
The command format is as follows.
Serial RS-232C
A command uses a 2-byte ASCII format, starting with Line Field (LF), which is followed by machine ID, and ending
with Carriage Return (CR).
For information about machine ID, see the section 3-2 Machine ID.
A command is followed by a byte string, which consists of data ranging from 0 bytes (if the command includes no
data) to 98 bytes, maximum.
For detailed information about data, see each of the sections explaining commands. Note that capital letters are
used for “A to F” for commands that use 0 to 9 and A to F as data values.
Command examples
Example 1: Sending the PLAY command to the controlled device with the machine ID=0
When the controlled device is in the stop or ready state, the PLAY command starts playing the
controlled device.
The PLAY command is [12] and sent in the following format.
ID Command
ASCII LF 0 1 2 CR
HEX 0Ah 30h 31h 32h 0Dh
Example 2: Performing a direct search for the track 12 on the controlled device with the machine ID=0
To do a direct search for the track 12, DIRECT TRACK SEARCH PRESET command [23] is sent.
Data bytes consist of 2-byte ASCII characters.
A track number is specified in the DIRECT TRACK SEARCH PRESET command as shown below.
Data 1 tens digit of the track number to be specified
Data 2 ones digit of the track number to be specified
Data 3 thousands digit of the track number to be specified
Data 4 hundreds digit of the track number to be specified
Based on the above rule, the send command is described as follows.
ID Command Data: 12th track
ASCII LF 0 2 3 1 2 0 0 CR
HEX 0Ah 30h 32h 33h 31h 32h 30h 30h 0Dh
-5-
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
ETHERNET (TELNET)
Commands start with an "ID" and end with a carriage return (CR) and a linefeed (LF), and are based on ASCII
format. Machine ID (ID) will be explained below.
Commands are expressed as two-byte ASCII.
For details about the data, see the explanation of each command. For commands that use data values from 0II
format. Machine ID (ID) will be explained–F.
Command examples
Example 1: Sending a PLAY command to a controlled device with Machine ID = 0
When stopped or in playback standby, this command will start playback on the controlled device.
The play command is "12" and is transmitted as follows.
ID Command
ASCII 0 1 2 CR LF
HEX 30h 31h 32h 0Dh 0Ah
Example 2: Specifying a direct search for track 123 on a controlled device with Machine ID = 0
This will send the "DIRECT TRACK SEARCH PRESET0follows.start playback on the con
Data bytes are formed of two-byte ASCII units.
The track number specification for the "DIRECT TRACK (TAKE) SEARCH PRESET this operation.trolled dData 1
Tens digit for specified track number
Data 2 Ones digit for specified track number
Data 3 Thousands digit for specified track number
Data 4 Hundreds digit for specified track number
Therefore, the transmitted command is as follows.
ID Command Data: take 123
ASCII 0 2 3 2 3 0 1 CR LF
HEX 30h 32h 33h 32h 33h 30h 31h 0Dh 0Ah
2.5. Machine ID
The Machine ID is fixed at [0]. A command with the machine ID other than [0] is ignored.
-6-
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
In most cases, the controlled device does not send an ACK command in response to a transport control command
or data preset command that is sent from an external controller.
The controlled device sends a return command in response to a data sense command that requests the controlled
device to return the controlled device's preset data values.
If the controlled device switches from one state to another - from stop state to playback state, for example, or if an
error occurs, the controlled device sends a command to notify the external controller about the state transition.
Examples of command sequences are shown below.
Make sure that commands are sent at a minimum of 20-millisecond intervals.
-7-
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Example 4: Performing the next operation after checking the status of the controlled device
When switching from one mode to another, the controlled device sends the CHANGED STATUS command.
Then, in response to the CHANGED STATUS command, the MECHA STATUS SENSE command is sent from
the external controller so that the new operation mode can be checked.
The following table shows that recording is started on the external controller after the controlled device’s
record ready mode is confirmed.
Command
Status of the controlled device
External controller Controlled device
STOP
RECORD (Record Ready) ->
CHANGED STATUS Sent when the controlled device
<-
enters record ready mode
MECHA STATUS SENSE ->
MECHA STATUS RETURN Returns the current status
<-
information (record ready)
RECORD (Record) ->
CHANGES STATUS Sent when the controlled device
<-
enters recording mode
Command details
The commands, data and Machine ID given here are ASCII characters.
Commands are 2-byte characters, the Machine ID is a 1-byte character and Data are each 1-byte characters.
The specifications for take and project numbers that this unit can handle are as follows. If a number is specified
for an item that does not exist, however, the command will be treated as invalid.
Track number (MP3/WAV MEDIA ) 999 maximum
Track number (Audio CD) 99 maximum
-8-
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Adopted
Control/Preset/Sense Command Return Command
F/W Ver
0F INFORMATION REQUEST 8F INFORMATION RETURN
10 STOP
12 PLAY
13 RECORD
14 READY
15 JOG
16 SHUTTLE
17 FLASH LOAD 97 FLASH LOAD ACKNOWLEDGE
18 EJECT
1A TRACK SKIP
1D CALL
20 AUTO CUE LEVEL PRESET A0 AUTO CUE LEVEL RETURN
21 AUTO TRACK LEVEL PRESET A1 AUTO TRACK LEVEL RETURN
23 DIRECT TRACK SEARCH PRESET
25 PITCH CONTROL DATA PRESET A5 PITCH CONTROL DATA RETURN
26 AUTO TRACK TIME PRESET A6 AUTO TRACK TIME RETURN Ver1.10
27 CLOCK DATA PRESET A7 CLOCK DATE RETURN
28 SYNC REC LEVEL PRESET A8 SYNC REC LEVEL RETURN
29 TEXT PRESET Ver1.10
2C TIME SEARCH PRESET
2D KEY CONTROL DATA PRESET AD KEY CONTROL DATA RETURN
30 AUTO CUE SELECT B0 AUTO CUE SELECT RETURN
31 AUTO TRACK SELCT B1 AUTO TRACK SELECT RETURN
32 EOM TRACK TIME PRESET B2 EOM TRACK TIME RETURN
33 EOM MEDIA TIME PRESET B3 EOM MEDIA TIME RETURN
35 PITCH CONTROL SELECT B5 PITCH CONTROL SELECT RETURN
36 AUTO READY SELECT B6 AUTO READY SELECT RETURN
37 REPEAT SELECT B7 REPEAT SELECT RETURN
38 SYNC REC SELECT B8 SYNC REC SELECT RETURN
3A INCR PLAY SELECT BA INCR PLAY SELECT RETURN
3D KEY CONTROL SELECT BD KEY CONTROL SELECT RETURN
4C REMOTE/LOCAL SELECT CC REMOTE/LOCAL SELECT RETURN
4D PLAY MODE SELECT
4E PLAY MODE SENSE CE PLAY MODE RETURN
50 MECHA STATUS SENSE D0 MECHA STATUS RETURN
55 TRACK NO. SENSE D5 TRACK NO. RETURN
56 MEDIA STATUS SENSE D6 MEDIA STATUS RETURN
57 CURRENT TRACK INFORMATION SENSE D7 CURRENT TRACK INFORMATION RETURN
58 CURRENT TRACK TIME SENSE D8 CURRENT TRACK TIME RETURN
59 NAME SENSE D9 NAME RETURN
5D TOTAL TRACK NO./TOTAL TIME SENSE DD TOTAL TRACK NO./TOTAL TIME RETURN
5E PGM TOTAL TRACK NO./TOTAL TIME SENSE DE PGM TOTAL TRACK NO./TOTAL TIME RETURN
5F KEYBOARD TYPE SENSE DF KYBOARD TYPE RETURN
F0 ERROR SENSE REQUEST
F1 CAUTION SENSE REQUEST
F2 ILLEGAL STATUS
F4 POWER ON STATUS
F6 CHANGE STATUS
-9-
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
- 10 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
- 11 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Command Details
・INFORMATION REQUEST
INFORMATION REQUEST requests the controlled device to return information including the software version of
the controlled device.
Command 0F
Data None
Return INFORMATION RETURN [8F]
・STOP
STOP puts the controlled device into the stop state and also takes the controlled device out of input monitor
mode.
Command 10
Data None
Return None
・PLAY
Play puts the controlled device into playback mode and also brings the controlled device from record ready
mode to recording mode.
Command 12
Data None
Return None
・RECORD
RECORD puts the controlled device into record ready mode. It also numbers tracks during recording and puts
the controlled device into input monitoring mode when no media is in the controlled device.
Command 13
Data 2 bytes
Return None
Data 1 Data 2 Description Remarks
0 0 Record This starts recording
0 1 Record ready Switches to record ready mode.
0 2 Track mark Numbers tracks during recording
1 0 Input Monitor Switches to input monitoring mode when no media is in
the controlled device.
·If the controlled device receives data other than the above data, it sends ILLEGAL (F2).
- 12 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
・READY
READY puts the controlled device into playback standby mode or record ready mode.
Command 14
Data 2 bytes
Return None
Data 1 Data 2 Description Remarks
0 1 Ready ON Switches to playback standby mode or record ready
mode.
·If the controlled device receives data other than the above data, it sends ILLEGAL (F2).
・JOG
Enables JOG playback of the controlled device.
Command 15
Data 2 bytes
Return None
Data 1 Data 2 Description Remarks
0 0 OFF Disables JOG playback.
0 1 ON Enables JOG playback.
1 0 Jog forward Frame accurate search in the forward direction
1 1 Jog reverse Frame accurate search in the backward direction
·If the controlled device receives data other than the above data, it sends ILLEGAL (F2).
・SHUTTLE
SHUTTLE puts the controlled device into the shuttle mode. The controlled device remains in the shuttle mode
until it receives a command such as STOP, PLAY, or READY.
Command 16
Data 2 bytes
Return None
Data 1 Data 2 Description Remarks
0 0 Shuttle forward Switches to the forward shuttle mode
0 1 Shuttle reverse Switches to the backward shuttle mode
·If the controlled device receives data other than the above data, it sends ILLEGAL (F2).
・FLASH LOAD
FLASH LOAD puts the controlled device into Flash Load mode.
Command 17
Data None
Return Flash Load Acknowledge [97]
- 13 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
・EJECT
EJECT ejects a CD Media from the controlled device.
(If the controlled device is SS-R250N, it returns ILLEGAL [F2].)
If the device selected on the controlled device is not CD, this command is ignored.
Command 18
Data None
Return None
・SKIP
SKIP allows the controlled device to skip a track.
Command 1A
Data 2 bytes
Return None
Data 1 Data 2 Description Remarks
0 0 Track Skip Next Skips to the next track
0 1 Track Skip Previous If the current position is at the beginning of a track (or
within one second of the beginning of a track), the
controlled device skips to the beginning of the previous
track. If the current position is not at the beginning of a
track, the controlled device skips to the beginning of the
current track.
2 0 Mark Skip Next Moves to the next mark.
2 1 Mark Skip Previous Moves to the previous mark.
3 0 Time Skip Next When playing back or in playback standby, you can skip
forward by the amount of time set using the time skip
function.
3 1 Time Skip Previous When playing back or in playback standby, you can skip
backward by the amount of time set using the time skip
function.
·If the controlled device receives data other than the above data, it sends ILLEGAL (F2).
・CALL
CALL locates the controlled device to a call point and puts the controlled device into the ready state.
Command 1D
Data None
Return None
- 14 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Command 20
Data 2 bytes
Return AUTO CUE LEVEL RETURN [A0]
Data 1 Data 2 Description Remarks
0 0 -24dB Sets the auto-cue level to -24dB
0 1 -30dB Sets the auto-cue level to -30dB
0 2 -36dB Sets the auto-cue level to -36dB
0 3 -42dB Sets the auto-cue level to -42dB
0 4 -48dB Sets the auto-cue level to -48dB
0 5 -54dB Sets the auto-cue level to -54dB
0 6 -60dB Sets the auto-cue level to -60dB
0 7 -66dB Sets the auto-cue level to -66dB
0 8 -72dB Sets the auto-cue level to -72dB
F F SENSE Requests the controlled device to return the current
auto-cue level setting
·If the controlled device receives data other than the above data, it sends ILLEGAL (F2).
Command 21
Data 2 bytes
Return AUTO TRACK LEVEL RETURN [A1]
Data 1 Data 2 Description Remarks
0 0 -24dB Sets the auto-track level to -24dB
0 1 -30dB Sets the auto-track level to -30dB
0 2 -36dB Sets the auto-track level to -36dB
0 3 -42dB Sets the auto-track level to -42dB
0 4 -48dB Sets the auto-track level to -48dB
0 5 -54dB Sets the auto-track level to -54dB
0 6 -60dB Sets the auto-track level to -60dB
0 7 -66dB Sets the auto-track level to -66dB
0 8 -72dB Sets the auto-track level to -72dB
F F SENSE Requests the controlled device to return the current
auto-track level setting
·If the controlled device receives data other than the above data, it sends ILLEGAL (F2).
- 15 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Command 23
Data 4 bytes
Return None
Description Remarks
Data 1 Tens digit of the track number
Data 2 Ones digit of the track number Track number
Data 3 Thousands digit of the track number Example) 2301: Track 123
Data 4 Hundreds digit of the track number
If the track number specified does not exist in the media, it sends ILLEGAL [F2].
Command 25
Data 4 bytes or 2 bytes
Return Pitch Control Data Return [A5]
Data1 Data2 Data3 Data4 Description Remarks
0 Positive (+) value
1 Negative (-) value
N2 N3 N1 N1: Tens digit of the pitch control value
Preset %
N2: Ones digit of the pitch control value
N3: First decimal place of the pitch control value
Example) 2310: -2.3%
F F … Sense Requests the controlled device to return the
current pitch control setting
·If the specified data is out of range, the controlled device sends ILLEGAL [F2].
- 16 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Command 26
Data 4 bytes or 2 bytes
Return Auto Track Time Return [A6]
Data1 Data2 Data3 Data4 Description Remarks
N1 N2 N3 N4 Times N1: Tens digit of the auto track time value (hours).
N2: Ones digit of the auto track time value (hours).
N3: Tens digit of the auto track time value (minutes).
N4: Ones digit of the auto track time value
(minutes).
F F … Sense Requests the controlled device to return the current
auto track time setting
·If the specified data is out of range, the controlled device sends ILLEGAL [F2].
Command 27
Data 10 bytes or 2 bytes
Return Clock Data Preset Return [A7]
Description Remarks
Data 1 Tens digit of the year (A.D.).
Data 2 Ones digit of the year (A.D.).
Data 3 Tens digit of the month. [Example]
Data 4 Ones digit of the month. 0802231234: February 23, 2008 / 12:34
Data 5 Tens digit of the date
If data 1 and data 2 are both “F”, the
Data 6 Ones digit of the date
controlled device returns the current Clock
Data 7 Tens digit of the hour. Data setting.
Data 8 Ones digit of the hour
Data 9 Tens digit of the minute
Data 10 Ones digit of the minute
・if the specified data does not exist, the controlled device sends ILLEGAL [F2].
- 17 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Command 28
Data 2 bytes
Return Sync Rec Level Return [A8]
Data 1 Data 2 Description Remarks
0 0 -24dB Sync Rec level setting is -24 dB.
0 1 -30dB Sync Rec level setting is -30 dB.
0 2 -36dB Sync Rec level setting is -36 dB.
0 3 -42dB Sync Rec level setting is -42 dB.
0 4 -48dB Sync Rec level setting is -48 dB.
0 5 -54dB Sync Rec level setting is -54 dB.
0 6 -60dB Sync Rec level setting is -60 dB.
0 7 -66dB Sync Rec level setting is -66 dB.
0 8 -72dB Sync Rec level setting is -72 dB.
F F Sense Requests the controlled device to return the current Sync Rec
Level setting.
・if the specified data is out of rage, the controlled device sends ILLEGAL [F2].
・TEXT PRESET
Specifies a CD-TEXT title for the controlled device of up to 80 single-byte alphanumeric characters.
To obtain the assigned title, transmit the command "TITLE SENSE [59]."
Command 29
Data 4 bytes~84 Bytes
Return None
Description Remarks
Data 1 Tens digit of specified number
Data 2 Ones digit of specified number 0000 Specify the disc title
Data 3 Thousands digit of specified number 0001 – 0099 Specify a track title
Data 4 Hundreds digit of specified number
Data 5 – Data 84 Title Single-byte alphanumeric characters
・If a track number not existing on the disc is specified, the controlled device will transmit ILLEGAL [F2].
・The title is between 0 bytes and 80 bytes. The characters up to the last one before CR will be used as
the specified title.
- 18 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Command 2C
Data 12 bytes
Return None
Description Remarks
Data 1 Tens digit of the track number
Data 2 Ones digit of the track number
Data 3 Thousands digit of the track number [Example]
Data 4 Hundreds digit of the track number 050006002030: 05tr 06min10.30sec
Data 5 Tens digit of the minutes
Data 6 Ones digit of the minutes
Data 7 Thousands digit of the minutes
Data 8 Hundreds digit of the minutes
Data 9 Tens digit of the seconds
Data 10 Ones digit of the seconds
Data 11 1/10 digit of the seconds
Data 12 1/100 digit of the seconds
·If the specified time does not exist in the media, the controlled device sends ILLEGAL [F2].
·If the specified data is out of range, the controlled device sends ILLEGAL [F2].
Command 2D
Data 2 bytes
Return KEY CONTROL DATA RETURN [AD]
Data 1 Data 2 Description Remarks
0 Key up
1 Key down
0-6 Key change Set in semitones
F F Sense Requests the controlled device to return the current Key
control data setting.
·If the specified data is out of range, the controlled device sends ILLEGAL [F2].
- 19 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Command 30
Data 2 bytes
Return AUTO CUE SELECT RETURN [B0]
Data1 Data2 Description Remarks
0 0 Auto-cue mode OFF Turns the Auto-cue mode off
0 1 Auto-cue mode ON Turns the Auto-cue mode on
F F Sense Requests the controlled device to return the
Auto-cue mode status
·If the specified data is out of range, the controlled device sends ILLEGAL [F2].
Command 31
Data 2 bytes
Return AUTO TRACK SELECT RETURN [B1]
Data1 Data2 Description Remarks
0 0 Auto Track OFF
0 1 Auto Track ON (LEVEL) Level Mode
0 2 Auto Track ON (Digital Direct) Digital Direct Mode
0 3 Auto Track ON (TIME) Time Mode
0 4 Auto Track ON (SIZE) File size Mode
F F Sense Requests the controlled device to return the Auto
Track mode status
·If the specified data is out of range, the controlled device sends ILLEGAL [F2].
- 20 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Command 32
Data 2 bytes
Return EOM TRACK TIME RETURN [B2]
Data1 Data2 Description Remarks
0 0 EOM Track OFF
A 0 EOM Track ON (0sec)
N1 N2 EOM Track ON N1: Tens digit of the EOM Track Time.
N2: Ones digit of the EOM Track Time.
F F Sense Requests the controlled device to return the EOM
Track Time setting.
·If the controlled device receives data other than the above data, it sends ILLEGAL (F2).
Command 33
Data 2 bytes
Return EOM MEDIA TIME RETURN [B3]
Data1 Data2 Description Remarks
0 0 EOM Media OFF
N1 N2 EOM Media ON N1: Tens digit of the EOM Media Time.
N2: Ones digit of the EOM Media Time.
F F Sense Requests the controlled device to return the EOM
Media Time setting.
·If the controlled device receives data other than the above data, it sends ILLEGAL (F2).
Command 35
Data 2 bytes
Return PITCH CONTROL SELECT RETURN [B5]
Data 1 Data 2 Description Remarks
0 0 Pitch control OFF
0 1 Pitch control ON
F F Sense Requests the controlled device to return the current
pitch control mode setting
·If the controlled device receives data other than the above data, it sends ILLEGAL (F2).
- 21 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Command 36
Data 2 bytes
Return AUTO READY SELECT RETURN [B6]
Data 1 Data 2 Description Remarks
0 0 Auto-ready OFF
0 1 Auto-ready ON
F F Sense Requests the controlled device to return the current
auto-ready mode setting
·If the controlled device receives data other than the above data, it sends ILLEGAL (F2).
・REPEAT SELECT
REPEAT SELECT turns the repeat mode of the controlled device on or off.
Only when this command is sent with request data [FF], the controlled device sends the REPEAT SELECT
RETURN command [B7].
Command 37
Data 2 bytes
Return REPEAT SELECT RETURN [B7]
Data 1 Data 2 Description Remarks
0 0 Repeat OFF
0 1 Repeat ON
F F Sense Requests the controlled device to return the
current repeat mode setting
·If the controlled device receives data other than the above data, it sends ILLEGAL (F2).
Command 38
Data 2 bytes
Return SYNC REC SELECT RETURN [B8]
Data 1 Data 2 Description Remarks
0 0 sync rec OFF
0 1 Sync rec ON
F F Sense Requests the controlled device to return the
current sync rec mode setting
·If the controlled device receives data other than the above data, it sends ILLEGAL (F2).
- 22 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Command 3A
Data 2 bytes
Return INCR PLAY SELECT RETURN [BA]
Data 1 Data 2 Description Remarks
0 0 Incremental playback OFF
0 1 Incremental playback ON
F F Sense Requests the controlled device to return the
current incremental playback mode setting
·If the controlled device receives data other than the above data, it sends ILLEGAL (F2).
Command 3D
Data 2 bytes
Return KEY CONTROL SELECT RETURN [BD]
Data 1 Data 2 Description Remarks
0 0 Key control mode OFF
0 1 Key control mode ON
F F Sense Requests the controlled device to return the
current key control mode setting
·If the controlled device receives data other than the above data, it sends ILLEGAL (F2).
- 23 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
・REMOTE/LOCAL SELECT
REMOTE/LOCAL SELECT enables or disables key operation on the controlled device.
Only when this command is sent with request data [FF], the controlled device sends the REMOTE/LOCAL
RETURN command [CC].
Command 4C
Data 2 bytes
Return REMOTE LOACAL [CC]
Data 1 Data 2 Description Remarks
0 0 Only remote Enables only remote operation through an
RS-232C, PARALLEL connector,
ETHERNET and remote control connected
to the REMOTE jack and a USB keyboard.
Key operation on the controlled device is
disabled
0 1 Remote and Front key Enables remote operation and key operation
on the controlled device
F F Sense Requests the controlled device to return the
current remote/local mode setting
·If the controlled device receives data other than the above data, it sends ILLEGAL (F2).
Command 4D
Data 2 bytes
Return None
Data 1 Data 2 Description Remarks
0 0 Continuous Continuous playback
0 1 Single Single playback
0 4 Program Programmed playback
0 6 Random Random playback
Command 4E
Data None
Return PLAY MODE RETURN [CE]
Command 50
Data None
Return MECHA STATSU RETURN [D0]
- 24 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Command: 55
Data: None
Return: TRACK No. STATUS RETURN [D5]
Command 56
Data None
Return MEDIA STATUS RETURN [D6]
Command 57
Data None
Return CURRENT TRACK INFORMATION RETURN [D7]
Command 58
Data 2 bytes
Return CURRENT TRACK TIME RETURN [D8]
Data 1 Data 2 Description Remarks
0 0 Track elapsed time
0 1 Track remaining time
0 2 Total elapsed time on the media
0 3 Total remaining time on the media
·If the controlled device receives data other than the above data, it sends ILLEGAL (F2).
- 25 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
・NAME SENSE
NAME SENSE requests the controlled device to return the specified track name.
Command 59
Data 4 bytes
Return NAME RETURN [D9]
Description Remarks
Data 1 Tens digit of the track number
Data 2 Ones digit of the track number 0000 Specifies the disc title(Only for CD-TEXT)
Data 3 Thousands digit of the track number 0001 – 0999 Specifies a track name (title)
Data 4 Hundreds digit of the track number
·If the specified track number does not exist in the media, it sends ILLEGAL [F2].
·If the name of specified track number contains a character that is not ASCII, it sends ILLEGAL [F2].
Command 5D
Data None
Return TOTAL TRACK No./TOTAL TIME RETURN [DD]
Command 5E
Data None
Return PGM TOTAL TRACK No./TOTAL TIME RETURN [DE]
Command 5F
Data None
Return KEYBOARD TYPE RETURN [DF]
- 26 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
・POWER CONTORL
POWER CONTROL turns ON / OFF (standby) the power of the controlled device.
When turning on from OFF, the REMOTE POWER CONTROL setting of the controlled device must be ON.
Command 75
Data None
Return STANDBY STATUS [F5]
Data 1 Data 2 Description Remarks
0 0 Power On Power on from the standby state.
1 1 Power Off The controlled device enters the standby state.
8 0 Reset The controlled device restarts.
If the controlled device does not stop, it sends ILLEGAL [F2].
・ERROR SENSE
ERROR SENSE requests the controlled device to return information about an error that occurred on the
controlled device. Be sure to determine the error by using this command if the ERROR SENSE REQUEST
command [F0] is issued from the controlled device.
Command: 78
Data: None
Return: ERROR SENSE RETURN [F8]
・CAUTION SNESE
CAUTION SENSE requests the controlled device to return information about a caution that is shown on the
controlled device. Be sure to check the caution by using this command if the CAUTION SENSE REQUEST
command [F1] is issued from the controlled device.
Command: 79
Data: None
Return: CAUTION SENSE RETURN [F9]
・VENDER COMMAND
This command controls a function unique to this unit. For details, see "Vender command details" on page
39.
Command: 7F
Return: VENDER COMMAND RETURN [FF]
- 27 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
・INFORMATION RETURN
INFORMATION RETURN is sent in response to the INFORMATION REQUEST command [0F] to show the
software version.
Command 8F
Data 4 bytes
Request command INFORMATION REQUEST [0F]
Description Remarks
Data 1 Tens digit of the software version
Data 2 Ones digit of the software version
Example) 0123: Version 01.23
Data 3 First decimal place of the software version
Data 4 Second decimal place of the software version
Command: 97
Data: None
Request command FLASH LOAD [17]
Command A0
Data 2 bytes
Request command AUTO CUE LEVEL PRESET [20]
Data 1 Data 2 Description Remarks
0 0 -24dB Auto cue level setting is -24 dB.
0 1 -30dB Auto cue level setting is -30 dB.
0 2 -36dB Auto cue level setting is -36 dB.
0 3 -42dB Auto cue level setting is -42 dB.
0 4 -48dB Auto cue level setting is -48 dB.
0 5 -54dB Auto cue level setting is -54 dB.
0 6 -60dB Auto cue level setting is -60 dB.
0 7 -66dB Auto cue level setting is -66 dB.
0 8 -72dB Auto cue level setting is -72 dB.
- 28 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Command A1
Data 2 bytes
Request command AUTO TRACK LEVEL PRESET [21]
Data 1 Data 2 Description Remarks
0 0 -24dB Auto track level setting is -24 dB.
0 1 -30dB Auto track level setting is -30 dB.
0 2 -36dB Auto track level setting is -36 dB.
0 3 -42dB Auto track level setting is -42 dB.
0 4 -48dB Auto track level setting is -48 dB.
0 5 -54dB Auto track level setting is -54 dB.
0 6 -60dB Auto track level setting is -60 dB.
0 7 -66dB Auto track level setting is -66 dB.
0 8 -72dB Auto track level setting is -72 dB.
Command A5
Data 4 bytes
Request command PITCH CONTROL DATA PRESET [25]
Data 1 Data 2 Data 3 Data 4 Description Remarks
0 Positive (+) value
1 Negative (-) value
N2 N3 N1 N1: Tens digit of the pitch control value
Preset % N2: Ones digit of the pitch control value
N3: First decimal place of the pitch control
value
Example) 2310: -2.3 %
Command A6
Data 4 bytes
Request command AUTO TRACK TIME PRESET [26]
Description Remarks
Data 1 Tens digit of the hour
Data 2 Ones digit of the hour
Data 3 Tens digit of the minute
Data 4 Ones digit of the minute
- 29 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Command A7
Data 12 bytes
Request command CLOCK DATA PRESET [27]
Description Remarks
Data 1 Tens digit of the year (A.D.).
Data 2 Ones digit of the year (A.D.).
Data 3 Tens digit of the month.
Data 4 Ones digit of the month. [Example]
Data 5 Tens digit of the date 0802231234: February 23, 2008 / 12:34
Command A8
Data 2 bytes
Request command SYNC REC LEVEL PRESET [28]
Data 1 Data 2 Description Remarks
0 0 -24dB Sync Rec level setting is -24 dB.
0 1 -30dB Sync Rec level setting is -30 dB.
0 2 -36dB Sync Rec level setting is -36 dB.
0 3 -42dB Sync Rec level setting is -42 dB.
0 4 -48dB Sync Rec level setting is -48 dB.
0 5 -54dB Sync Rec level setting is -54 dB.
0 6 -60dB Sync Rec level setting is -60 dB.
0 7 -66dB Sync Rec level setting is -66 dB.
0 8 -72dB Sync Rec level setting is -72 dB.
Command AD
Data 2 bytes
Request command KEY CONTROL DATA PRESET [2D]
Data 1 Data 2 Description Remarks
0 Key up
1 Key down
0-6 Key change Set in semitones
- 30 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Command B0
Data 2 bytes
Request command AUTO CUE SELECT [30]
Data 1 Data 2 Description Remarks
0 0 Auto cue mode OFF
0 1 Auto cue mode ON
Command B1
Data 2 bytes
Request command AUTO TRACK SELECT [31]
Data 1 Data 2 Description Remarks
0 0 Auto track mode OFF
0 1 Auto track mode ON (LEVEL) Level mode
0 2 Auto track mode ON (Digital Direct) Digital Direct mode
0 3 Auto track mode ON (Time) Time mode
0 4 Auto track mode ON (SIZE) File size mode
Command B2
Data 2 bytes
Request command EOM TRACK TIME PRESET [32]
Data1 Data2 Description Remarks
0 0 EOM Track OFF
A 0 EOM Track ON (0 sec)
N1 N2 EOM Track ON N1: Tens digit of the EOM Track Time.
N2: Ones digit of the EOM Track Time.
Command B3
Data 2 bytes
Request command EOM MEDIA TIME PRESET [33]
Data1 Data2 Description Remarks
0 0 EOM Media OFF
N1 N2 EOM Media ON N1: Tens digit of the EOM Media Time.
N2: Ones digit of the EOM Media Time.
- 31 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Command B5
Data 2 bytes
Request command PITCH CONTROL SELECT [35]
Data 1 Data 2 Description Remarks
0 0 Pitch control OFF
0 1 Pitch control ON
Command B6
Data 2 bytes
Request command AUTO READY SELECT [36]
Data 1 Data 2 Description Remarks
0 0 Auto-ready OFF
0 1 Auto-ready ON
Command B7
Data 2 bytes
Request command REPEAT SELECT [37]
Data 1 Data 2 Description Remarks
0 0 Repeat OFF
0 1 Repeat ON
Command B8
Data 2 bytes
Request command SYNC REC SELECT [38]
Data 1 Data 2 Description Remarks
0 0 Sync rec OFF
0 1 Sync rec ON
- 32 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Command BA
Data 2 bytes
Request command INCR PLAY SELECT [3A]
Data 1 Data 2 Description Remarks
0 0 INCR playback OFF
0 1 INCR playback ON
Command BD
Data 2 bytes
Request command KEY CONTROL SELECT [3D]
Data 1 Data 2 Description Remarks
0 0 Key control OFF
0 1 Key control ON
Command CC
Data 2 bytes
Request command REMOTE/LOCAL SELECT [4C]
Data 1 Data 2 Description Remarks
0 0 Only remote Enables only remote operation through an
RS-232C, PARALLEL connector,
ETHERNET and remote control
connected to the REMOTE jack and a
USB keyboard.
Key operation on the controlled device is
disabled
0 1 Remote and Front key Enables remote operation and key
operation on the controlled device
- 33 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Command CE
Data 2 bytes
Request command PLAY MODE SENSE [4E]
Data 1 Data 2 Description Remarks
0 0 Continuous playback
0 1 Single playback
0 4 Programmed playback
(data not available)
0 5 Programmed playback
(data available)
0 6 Random playback
Command D0
Data 2 bytes
Request command MECHA STATUS SENSE [50]
Data 1 Data 2 Description Remarks
0 0 No Media No Media
0 1 Preparing for disc ejection In disc-ejecting state
1 0 Stop In stop state
1 1 Play In playback state
1 2 Ready In ready state
2 8 Cue Searching forward
2 9 Review Searching backward
8 0 Monitor In input monitoring state
8 1 Record In recording state
8 2 Record ready In record ready state
8 3 Information writing In information writing state
F F Other Some other status
- 34 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Command D5
Data 6 bytes
Request command TRACK No. SENSE [55]
Description Remarks
Data 1 EOM Status 00: Shows that the current track has yet to
Data 2 reach the set EOM time or EOM display
mode is turned off
01: Shows that the controlled device is
displaying the EOM time
Data 3 Tens digit of the track number
Data 4 Ones digit of the track number
Data 5 Thousands digit of the track number
Data 6 Hundreds digit of the track number
Command D6
Data 4 bytes
Request command MEDIA STATUS SENSE [56]
Data 1 00: No media
Media status
Data 2 01: Media loaded
00: CD-DA
Data 3 01: CD-R(Audio)
02: CD-RW(Audio)
Media type
10: CD-ROM (Data)
Data 4 11: CD-R(Data)
12: CD-RW(Data)
- 35 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Command D7
Data 12 bytes
Request command CURRENT TRACK INFORMATION SENSE [57]
Description Remarks
Data 1 Tens digit of the track number or the program number
Data 2 Ones digit of the track number or the program number
Data 3 Thousands digit of the track number
Data 4 Hundreds digit of the track number If the playback mode
Data 5 Tens digit of the minutes is set to program
Data 6 Ones digit of the minutes (PGM), the controlled
Data 7 Thousands digit of the minutes device sends only
Data 8 Hundreds digit of the minutes the program number
Data 9 Tens digit of the seconds for data1 and data2.
Data 10 Ones digit of the seconds
Data 11 Tens digit of the frames
Data 12 Ones digit of the frames
Command D8
Data 10 bytes
Request command CURRENT TRACK TIME SENSE [58]
Description Remarks
(Data 1, Data 2) 00 Elapsed time
01 Track remaining time
02 Total elapsed time on the media
03 Total remaining time on the media
Data 3 -- Tens digit of the minutes
Data 4 -- Ones digit of the minutes
Data 5 -- Thousands digit of the minutes
Data 6 -- Hundreds digit of the minutes
Data 7 -- Tens digit of the seconds
Data 8 -- Ones digit of the seconds
Data 9 -- Tens digit of the frame
Data10 -- Ones digit of the frame
- 36 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
・NAME RETURN
NAME RETURN is sent in response to the NAME SENSE command [59] to show the name of the specified
track. If the specified track is a file, the reply includes the file extension.
If the specified track name does not exist or contains a character that is not ASCII, the controlled device sends
ILLEGAL [F2]
Command D9
Data 5 - 124 bytes
Request command NAME SENSE [59]
Description Remarks
Data 1 Tens digit of the track
Data 2 Ones digit of the track 0000 Disc title( for CD-TEXT only)
Data 3 Thousand digit of the track 0001 – 0999 Track name (title)
Data 4 Hundred digit of the track
Data 5 – Data124 Name(title) ASCII characters
·The title is composed of 0 to 120 bytes.
Command DD
Data 12 bytes
Request command TOTAL TRACK No./TOTAL TIME SENSE [5D]
Description Remarks
Data 1 Tens digit of the total number of tracks
Data 2 Ones digit of the total number of tracks
Data 3 Thousands digit of the total number of tracks
Data 4 Hundreds digit of the total number of tracks
Data 5 Tens digit of the minutes
Data 6 Ones digit of the minutes
Data 7 Thousands digit of the minutes
Data 8 Hundreds digit of the minutes
Data 9 Tens digit of the seconds
Data10 Ones digit of the seconds
Data11 Tens digit of the total number of frames of all tracks
Data12 Ones digit of the total number of frames of all tracks
- 37 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Command DE
Data 12 bytes
Request command PGM TOTAL TRACK No./TOTAL TIME SENSE [5E]
Description Remarks
Data 1 Tens digit of the total number of tracks
Data 2 Ones digit of the total number of tracks
Data 3 Thousands digit of the total number of tracks
Data 4 Hundreds digit of the total number of tracks
Data 5 Tens digit of the minutes
Data 6 Ones digit of the minutes
Data 7 Thousands digit of the minutes
Data 8 Hundreds digit of the minutes
Data 9 Tens digit of the seconds
Data10 Ones digit of the seconds
Data11 Tens digit of the frame
Data12 Ones digit of the frame
Command DF
Data 2 bytes
Request command KEYBOARD TYPE SENSE [5F]
Data 1 Data 2 Description Remarks
0 0 Japanese
0 1 US
Command F0
Data None
Request command None
Command F1
Data None
Request command None
- 38 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
・ILLEGAL STATUS
ILLEGAL STATUS is sent from the controlled device to the external controller to show that an invalid command
or data has been sent to the controlled device. If the command is sent, send a command or data again, making
sure that it is a valid command or data.
Command F2
Data None
Request command None
・POWER ON STATUS
POWER ON STATUS is sent from the controlled device to the external controller to show that the controlled
device has been turned on.
Command F4
Data None
Request command None
・STANDBY STATUS
STANDBY STATUS is sent in response to the POWER CONTROL command [75].
Command F5
Data None
Request command None
・CHANGE STATUS
CHANGE STATUS is sent from the controlled device to the external controller to show that the controlled device
has switched from one state to another.
Command F6
Data 2 bytes
Request command None
Data 1 Data 2 Description Remarks
0 0 Mechanism status change The status of the specified mechanism has
been changed.
0 3 Track and EOM status changes The controlled device has moved from one
track to another or the EOM status has
been changed.
- 39 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Command F8
Data 4 bytes
Request command ERROR SENSE [78]
Data 1 N2 ERROR CODE(N1-N2N3)
Data 2 N3 0-00 No Error
Data 3 0 1-01 Rec Error (error related to recording)
Date 4 N1 1-02 Device Error (error related to device)
1-08 Stand-By Error (error during recording preparation)
1-09 Information Write Error (error during final recording processing)
1-FF Other Error (An error other than those above occurred. Check the unit.)
Command F9
Data 4 bytes
Request command CAUTION SENSE [79]
Data 1 N2 CAUTION CODE(N1-N2N3)
Data 2 N3 0-00 No Caution
Data 3 0 1-02 Media Error (error related to media)
Data 4 N1 1-03 Can't Undo
1-06 Media Full (media has no remaining capacity)
1-07 Track Full (maximum track size has been reached)
1-09 D-In Unlock (digital input is unlocked)
1-0A No Call Point
1-0B Can't REC (recording is not possible)
1-0C Write Protected (media is write-protected)
1-0D Not Execute (function cannot be executed in this state)
1-0F Can't Edit (editing is not possible in this state)
1-13 Can't Select (selecting is not possible in this state)
1-14 Track Protected
1-16 Name Full (name setting character upper limit has been reached)
1-18 Play List Error (error related to playlist)
1-1D Not Audio (digital input is not audio)
1-1E Decode Error (error related to playback)
1-1F Media Not Match (media is not suitable)
1-FF Other Caution (A caution other than those above occurred. Check the
unit.)
- 40 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Command FF
- 41 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Serial RS-232C
Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8 Byte 9 … Byte n
LF ID Command Data 1 Data 2 Data 3 Data 4 Data 5 … CR
LF ‘0’ ‘7F’ or ‘FF’ Category Code Sub Command Parameter … CR
ETHERNET (TELNET)
Byte 1 2 3 4 5 6 7 8 ... n-1 n
ID Command Data 1 Data 2 Data 3 Data 4 Data 5 ... LF CR
‘0’ ‘7F’ or ‘FF’ Category Code Sub Command Parameter … LF CR
Category Code: The category code (2-byte ASCII) is used for classifying vendor commands according to
function.
Sub Command: This is a unique sub-command code (2-byte ASCII) within the category.
DEVICE SELECT (01), DIVIDE(02) and DELETE(03)is the only category that has no sub
command.
DEVICE SELECT (01) is Data 3 and higher are parameters.
Parameter: This is a parameter added to the command code (ASCII, length differs for each sub command.)
・DEVICE SELECT
DEVICE SELECT changes the device to be used on the controlled device.
Command 7F
Category Code 01
Parameter: 2 bytes
Return DEVICE SELECT RETURN [FF01]
Data 3 Data 4 Function Remarks
0 0 SD1 Sets the device to SD1
0 1 SD2 Sets the device to SD2.
1 0 USB Sets the device to USB
1 1 CD Sets the device to CD
If the controlled device is SS-R250N, it sends ILLEGAL [F2]
F F Sense Requests the controlled device to return the current device.
·If the controlled device receives data other than the above data, it sends ILLEGAL (F2).
- 42 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
・DIVIDE
The File currently in playback standby mode on the controlled device is divided into two files at that point.
This command is not available when playback is stopped.
This command is not available for MP3 files.
This command is not available when the Play Area setting is PLAYLIST.
This command is only available when the playback mode is set to continuous.
Command 7F
Category Code 02
Return Non
・DELETE
The file(s) for the current track on the controlled device are deleted.
This command is only available when playback is stopped.
This command is not available when the Play Area setting is PLAYLIST.
This command is only available when the playback mode is set to continuous.
Command 7F
Category Code 03
Return Non
Command 7F
Category Code 07
Sub Command 01
Parameter 4 bytes
Return Non
Description Remarks
Data 5 Ten digits of set time 0000 TIME SKIP : OFF
Data 6 One digit of the set time 0001 - 0059 1 – 59 sec
Data 7 Thousands of digits of set time 0060 – 0299 1 min
Data 8 One hundred digits of set time 0300 – 0599 5 min
0600 - 10 min
Command 7F
Category Code 07
Sub Command 02
Return TIME SKIP RETURN [FF0702]
- 43 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Command 7F
Category Code 07
Sub Command 4F
Parameter 2 bytes
Return PLAY AREA SELECT RETURN [FF07CF].
Command 7F
Category Code 08
Sub Command 23
Parameter 6 bytes or 2 bytes
Return AUTO TRACK SIZE RETURN [FF08A3].
- 44 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
・INPUT SELECT
INPUT SELECT sets the input source select of the controlled device.
Specify "00" for Data 5-6.
A return command is only sent when Sense [FF] is specified for Data 7 and Data 8 -, the controlled device
sends the INPUT SELECT RETURN command [FF1290].
When DIGITAL XLR or DIGITAL COAXIAL is selected, the LINK PLAY playback mode setting is turned OFF.
Before switching to ANALOG BALANCED, please make sure that the phantom power supply state from this
unit is correct for the connected device.
Command 7F
Category Code 12
Sub Command 10
Parameter 6 bytes
Return INPUT SELECT RETURN [FF1290].
・FILE RENAME
Change the name of a specified file in the current device on the controlled device.
The file name a maximum of 117 bytes in UTF-8 format can be sent from Data 9 on.
At the beginning and end of processing, the controlled device will return "FILE RENAME ACKNOWLEDGE
[FF4280]".
Command 7F
Category Code 42
Sub Command 00
Parameter 5-121 bytes
Return FILE RENAME ACKNOWLEDGE [FF4280].
Description Remarks
Data 5 File number tens digit
Data 6 File number ones digit Specified file number
Data 7 File number thousands digit Example: "1400" is file No.14
Data 8 File number hundreds digit
Data 9 – 125 File name UTF-8
·If the controlled device receives data other than the above data, it sends ILLEGAL (F2).
- 45 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Command 7F
Category Code 4A
Sub Command 23
Parameter 4 bytes
Return None.
Description Remarks
Data 5 Folder number tens digit
Data 6 Folder number ones digit Specified folder number
Data 7 Folder number thousands digit Example: "2400" is folder No.24
Data 8 Folder number hundreds digit
·If the folder number that does not exist directly under the root folder is specified, it sends ILLEGAL
(F2).
If it is specified the current folder to the folder number , it sends ILLEGAL (F2).
・CREATE FOLDER
Create a new folder with the name specified directly under the root folder in the current device for the
controlled device.
The folder name is a maximum of 117 bytes in UTF-8 format can be sent from Data 5 on.
At the beginning and end of processing, the controlled device will return "CREATE FOLDER
ACKNOWLEDGE [FF4AC0]".
Command 7F
Category Code 4A
Sub Command 40
Parameter 1-117 bytes
Return CREATE FOLDER ACKNOWLEDGE [FF4AC0].
Description Remarks
Data 5 – 121 Folder name UTF-8
·If the controlled device receives data other than the above data, it sends ILLEGAL (F2).
- 46 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
・FOLDER RENAME
Change the name of a specified folder in the current device on the controlled device.
The folder name a maximum of 117 bytes in UTF-8 format can be sent from Data 9 on.
The target is only the folder directly under the root folder.
At the beginning and end of processing, the controlled device will return "FOLDER RENAME
ACKNOWLEDGE [FF4AC2]".
Command 7F
Category Code 4A
Sub Command 42
Parameter 5-121 bytes
Return FOLDER RENAME ACKNOWLEDGE [FF4AC2].
Description Remarks
Data 5 Folder number tens digit
Data 6 Folder number ones digit Specified folder number
Data 7 Folder number thousands digit Example: "2400" is folder No.24
Data 8 Folder number hundreds digit
Data 9 – 125 Folder name UTF-8
·If the folder number that does not exist directly under the root folder is specified, it sends ILLEGAL
(F2).
·If the controlled device receives data other than the above data, it sends ILLEGAL (F2).
Command 7F
Category Code 4A
Sub Command 55
Parameter None
Return CURRENT FOLDER No. RETURN [FF4AD5].
Command 7F
Category Code 4A
Sub Command 56
Parameter 1-117 bytes
Return SEARCH FOLDER No. RETURN [FF4AD6].
Description Remarks
Data 5 – 121 Folder name UTF-8
·If the controlled device receives data other than the above data, it sends ILLEGAL (F2).
- 47 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Command 7F
Category Code 4A
Sub Command 59
Parameter 4 bytes
Return FOLDER NAME RETURN [FF4AD9].
Description Remarks
Data 5 Folder number tens digit
Data 6 Folder number ones digit Specified folder number
Data 7 Folder number thousands digit Example: "2400" is folder No.24
Data 8 Folder number hundreds digit
·If the folder number that does not exist directly under the root folder is specified, it sends ILLEGAL
(F2).
·If the controlled device receives data other than the above data, it sends ILLEGAL (F2).
Command 7F
Category Code 4A
Sub Command 5A
Parameter 4 bytes
Return FILE NAME RETURN [FF4ADA].
Description Remarks
Data 5 File number tens digit
Data 6 File number ones digit Specified file number
Data 7 File number thousands digit Example: "1200" is file No.12
Data 8 File number hundreds digit
·If the controlled device receives data other than the above data, it sends ILLEGAL (F2).
Command 7F
Category Code 4A
Sub Command 5D
Parameter None
Return FOLDER COUNT RETURN [FF4ADD].
- 48 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Command 7F
Category Code 4A
Sub Command 5E
Parameter 4 bytes
Return FILE COUNT RETURN [FF4ADE].
Description Remarks
Data 5 Folder number tens digit
Data 6 Folder number ones digit Specified folder number
Data 7 Folder number thousands digit Example: "2400" is folder No.24
Data 8 Folder number hundreds digit
·If the folder number that does not exist directly under the root folder is specified, it sends ILLEGAL
(F2).
·If the controlled device receives data other than the above data, it sends ILLEGAL (F2).
Command FF
Category Code 01
Parameter 2 bytes
Request command DEVICE SELECT [7F01]
Data 3 Data 4 Function Remarks
0 0 SD1 SD1 is selected
0 1 SD2 SD2 is selected.
1 0 USB USB is selected.
1 1 CD CD is selected.
Command FF
Category Code 07
Sub Command 02
Parameter 4 bytes
Request command DEVICE SELECT [7F02]
Description Remarks
Data 5 Ten digits of set time 0000 TIME SKIP : OFF
Data 6 One digit of the set time 0001 - 0059 1 – 59 sec
Data 7 Thousands of digits of set time 0060 1 min
Data 8 One hundred digits of set time 0300 5 min
0600 - 10 min
- 49 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Command FF
Category Code 07
Sub Command CF
Parameter 2 bytes
Request command PLAY AREA SELECT [7F074F]
Data 5 Data 6 Description Remarks
0 0 All Play all the files on the medium
0 1 Folder Play all the files in the folder that contains the currently
selected file
0 2 Playlist Play all the files that have been assigned to the playlist
Command FF
Category Code 08
Sub Command A3
Parameter 6 bytes
Request command AUTO TRACK SIZE PRESET [7F0823]
Data 5/6 Data 7 Data 8 Data 9 Data10 Description Remarks
4 0 0 6 640MB
00 2 4 1 0 1GB File Size (MByte)
4 8 2 0 2GB
Command FF
Category Code 12
Sub Command 90
Parameter 6 bytes
Request command INPUT SELECT [7F1210]
Data 5/6 Data 7/8 Data 9/10 Description Remarks
Input from ANALOG MIC/LINE
00 ANALOG BALANCED
IN (BALANCED) L/R jacks
00
Input from ANALOG IN
01 ANALOG UNBALANCED
(UNBALANCED) L/R jacks
00
00 DIGITAL XLR Input from AES/EBU IN jack
01
01 DIGITAL COAXIAL Input from SPDIF IN jack
IF-DA2(DANTE) Input from IF-DA2 Dante
02 00
(Available if IF-DA2 installed) interface card
- 50 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Command FF
Category Code 42
Sub Command 80
Parameter 2 bytes
Request command FILE RENAME [7F4200]
Data 5 Data 6 Description Remarks
0 0 Start Processing started
1 1 End ( OK ) Processing completed successfully
1 2 End ( NG ) Processing was not possible or failed
Command FF
Category Code 4A
Sub Command C0
Parameter 6 bytes or 2 bytes
Request command CREATE FOLDER [7F4A40]
Description Remarks
Data 5 1
End ( OK ) processing completed successfully
Data 6 1
Data 7 Folder number tens digit
Data 8 Folder number ones digit Specified folder number
Data 9 Folder number thousands digit Example: "2400" is folder No.24
Data 10 Folder number hundreds digit
·
Data 5 Data 6 Description Remarks
0 0 Start Processing started
1 2 End ( NG ) Processing was not possible or failed
Command FF
Category Code 4A
Sub Command C2
Parameter 2 bytes
Request command RENAME FOLDER [7F4A42]
Data 5 Data 6 Description Remarks
0 0 Start Processing started
1 1 End ( OK ) Processing completed successfully
1 2 End ( NG ) Processing was not possible or failed
- 51 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Command FF
Category Code 4A
Sub Command D5
Parameter 4 bytes
Request command CURRENT FOLDER No. SENSE [7F4A55]
Description Remarks
Data 5 Folder number tens digit
Data 6 Folder number ones digit Current folder number
Data 7 Folder number thousands digit Example: "2400" is folder No.24
Data 8 Folder number hundreds digit
Command FF
Category Code 4A
Sub Command D6
Parameter 4 bytes
Request command SEARCH FOLDER No. [7F4A56]
Description Remarks
Data 5 Folder number tens digit
Data 6 Folder number ones digit Folder number
Data 7 Folder number thousands digit Example: "2400" is folder No.24
Data 8 Folder number hundreds digit
Command FF
Category Code 4A
Sub Command D9
Parameter 5-124 bytes
Request command FOLDER NANE SENSE [7F4A59]
Description Remarks
Data 5 Folder number tens digit
Data 6 Folder number ones digit Specified folder number
Data 7 Folder number thousands digit Example: "2400" is folder No.24
Data 8 Folder number hundreds digit
Data 9 – Data 128 Folder name UTF-8
- 52 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Command FF
Category Code 4A
Sub Command DA
Parameter 5-124 bytes
Request command FILE NANE SENSE [7F4A5A]
Description Remarks
Data 5 File number tens digit
Data 6 File number ones digit Specified file number
Data 7 File number thousands digit Example: "1200" is file No.12
Data 8 File number hundreds digit
Data 9 – Data 128 File name UTF-8
Command FF
Category Code 4A
Sub Command DD
Parameter 12 bytes
Request command FOLDER COUNT SENSE [7F4A5D]
Description Remarks
Data 5 Start folder number tens digit
Data 6 Start folder number ones digit Start folder number
Data 7 Start folder number thousands digit Example: "0100" is folder No.1
Data 8 Start folder number hundreds digit
Data 9 End folder number tens digit
Data 10 End folder number ones digit End folder number
Data 11 End folder number thousands digit Example: "2400" is folder No.24
Data 12 End folder number hundreds digit
Data 13 Number of folders tens digit
Data 14 Number of folders ones digit Number of folders
Data 15 Number of folders thousands digit Example: "2400" is 24
Data 16 Number of folders hundreds digit
- 53 -
RS-232C/TELNET Protocol Specifications Ver. 1.11 SS-CDR250N/SS-R250N
Command FF
Category Code 4A
Sub Command DE
Parameter 16 bytes
Request command FILE COUNT SENSE [7F4A5E]
Description Remarks
Data 5 Folder number tens digit
Data 6 Folder number ones digit Specified folder number
Data 7 Folder number thousands digit Example: "0200" is folder No.2
Data 8 Folder number hundreds digit
Data 9 Start file number tens digit
Data 10 Start file number ones digit Start file number
Data 11 Start file number thousands digit Example: "0800" is file No.8
Data 12 Start file number hundreds digit
Data 13 End file number tens digit
Data 14 End file number ones digit End file number
Data 15 End file number thousands digit Example: "1600" is file No.16
Data 16 End file number hundreds digit
Data 17 Number of files tens digit
Data 18 Number of files ones digit Number of files
Data 19 Number of files thousands digit Example: "0900" is 9
Data 20 Number of files hundreds digit
- 54 -