1/2" Cellflex Low-Loss Foam-Dielectric Coaxial Cable: LCF12-50JFN
1/2" Cellflex Low-Loss Foam-Dielectric Coaxial Cable: LCF12-50JFN
1/2" Cellflex Low-Loss Foam-Dielectric Coaxial Cable: LCF12-50JFN
LCF12-50JFN
CELLFLEX® 1/2" low loss flexible cable; flame retardant/ halogen free jacket
FEATURES / BENEFITS
Low Attenuation
The low attenuation of CELLFLEX® coaxial cable results in highly efficient signal transferin your RF
system.
Complete Shielding
The solid outer conductor of CELLFLEX® coaxial cable creates a continuous RFI/EMI shield that
minimizes system interference.
Low VSWR 1/2" CELLFLEX® Low-Loss Foam
Special low VSWR versions of CELLFLEX® coaxial cables contribute to low system noise. Dielectric Coaxial Cable
Outstanding Intermodulation Performance
CELLFLEX® coaxial cable's solid inner and outer conductors virtually eliminate intermods.
Intermodulation performance is also confirmed with state-of-the-art equipment at the RFS factory.
High Power Rating
Due to their low attenuation, outstanding heat transfer properties and temperature stabilized dielectric
materials, CELLFLEX® cable provides safe long term operating life at high transmit power levels.
Wide Range of Application
Typical areas of application are: feedlines for broadcast and terrestrial microwave antennas, wireless
cellular, PCS and ESMR base stations, cabling of antenna arrays, and radio equipment interconnects.
Technical Features
APPLICATIONS
OEM jumpers, Main feed transitions to equipment, GPS lines, Riser-rated In-Building, CPR
Applications
classified cable
STRUCTURE
Cable Type Foam-Dielectric, Corrugated
Size 1/2"
Jacket Option Black
Inner Conductor mm (in) 4.8 (0.19) Copper-Clad Aluminum Wire
Dielectric mm (in) 11.9 (0.47) Foam Polyethylene
Outer Conductor mm (in) 13.8 (0.54) Corrugated Copper
Jacket mm (in) 15.8 (0.62) Polyethylene, PE, Metalhydroxite Filling
ELECTRICAL SPECIFICATIONS
Impedance ȍ 50 +/- 1
Maximum Frequency GHz 8.8
Velocity % 88.0
Capacitance pF/m (pF/ft) 76 (23.2)
Inductance µH/m (µH/ft) 0.19 (0.058)
Peak Power Rating kW 38.0
RF Peak Voltage Volts 1950.0
Jacket Spark Volt RMS 8000.0
Inner Conductor dc Resistance ȍm ȍft) 1.57 (0.48)
Outer Conductor dc Resistance ȍm ȍft) 2.7 (0.82)
Return Loss (VSWR) Performance Standard
Maximum Return Loss dB (VSWR) Contact RFS for your VSWR performance specification for your required frequency band.
Phase Stabilized Phase stabilized and phase matched cables and assemblies are available upon request.
Temperature & Power Standard
MECHANICAL SPECIFICATIONS
Cable Weight kg/m (lb/ft) 0.23 (0.16)
Minimum Bending Radius, Single Bend mm (in) 70 (3)
Minimum Bending Radius, Repeated Bends mm (in) 125 (5)
Bending Moment Nm (lb*ft) 6.5
Tensile Strength N (lb) 1100 (247)
Recommended / Maximum Clamp Spacing m (ft) 0.6 / 1 (2 / 3.25)
All values nominal unless tolerances provided; information contained in the present datasheet is subject to confirmation at time of ordering Page 1 of 2
PRODUCT DATASHEET
LCF12-50JFN
All values nominal unless tolerances provided; information contained in the present datasheet is subject to confirmation at time of ordering Page 2 of 2