Column at Node No. A. General Data

This document provides design details for a reinforced concrete column with a length of 2.85m supporting an axial load of 497kN and moment of 3kN-m. The column has dimensions of 230mm x 300mm and is classified as a long column. Calculations show the required steel area is 1242mm2. The proposed design uses 16mm and 12mm diameter longitudinal bars with a total area of 1256.64mm2 meeting the requirement. Stirrups of 8mm diameter are specified at 250mm centers.

Uploaded by

saroj sanyasi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (1 vote)
232 views2 pages

Column at Node No. A. General Data

This document provides design details for a reinforced concrete column with a length of 2.85m supporting an axial load of 497kN and moment of 3kN-m. The column has dimensions of 230mm x 300mm and is classified as a long column. Calculations show the required steel area is 1242mm2. The proposed design uses 16mm and 12mm diameter longitudinal bars with a total area of 1256.64mm2 meeting the requirement. Stirrups of 8mm diameter are specified at 250mm centers.

Uploaded by

saroj sanyasi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 2

Column No.

1
Column at node no.

A. General data:
Length of column, L = 2.85 m
Factored axial load, Pu = 497.0 kN
Unfactored Moment , M = 3.0 kN m
Factored Moment , Mu = 4.5 kN m

B. Assume Size of column:


Shorter side, b = 230 mm
Longer side, D = 300 mm
Grade of concrete, fck = 20 N/mm2
Grade of steel, fy = 415 N/mm2
Assume d' = 50 mm
Self wt. of column = 4.9 kN
Design axial load = 504.4 kN
C. Calculation of slenderness:
Effective length, Le = 1.00 x L
Le = 2.85 m
Le / b = 12.4 > 12
It is long column
D. Check for eccentricity:
emin = (L/500)+(D/300) = 6.70 mm
M / P = e = 8.9 mm

Pu / fckbD = 0.365
Mu / fckbD2 = 0.011
d' / D = 0.167
E. Calculation of steel:
By SP-16,
p / fck = 0.09
Pt = 1.80 %
Min Pt. required = 0.80 %
Max. pt. = 6.00 %

Required area of steel Ast = (Pt x b x D)/100 = 1242.0 mm2

F. Longitudinal steel:
Use dia. Of bar, f = 16 mm + 12 mm
Provided no. of bar = 4 4 mm
Provided Area of steel = 804.25 452.39
Total provided Ast = 1256.64 mm2 O.K.
G. Design of stirrups:
Min. dia of stirrups, f/4 or 6 mm = 4.00 mm or 6mm
Provide dia. of stirrups = 8 mm
Spacing not less than,
(a) Dimension of column = 415 mm
(b) 16 times dia. Of longitudinal bar = 256 mm
(c) 300 mm 300 mm
Provided spacing of stirrups = 250 mm c/c