EB8870

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

INJECTION PUMP TEST SPECIFICATIONS 190000-8870

INJECTION PUMP 190000-887# MANU-


KOMATSU
(ND-PE6NB110) FACTURER
GOVERNOR 090800-909# (RSV) ENGINE
6D125
TYPE
TIMER — VEHICLE
BULLDOZER
MODEL

1.INJECTION TIMING

1) Rotation : Counterclockwise 4) Pre-stroke : 4.65 – 4.75 mm


viewed from drive side

2) Injection Order : 1–5–3–6–2–4 5) Tappet Clearance : —

3) Injection Interval : 60° ± 30' 6) Locked Timing : —


Location

2.ADJUSTMENT OF DELIVERY QUANTITY

Test Conditions

1) Nozzle : 093400 – 0540 4) Feed Pressure : 1.6 kgf/cm 2


(DN12SD12A)

2) Nozzle Opening : 175 kgf/cm 2 5) High Pressure Pipe : ø2 x ø6 x 600 mm


Pressure

3) Test Oil : SAE J967 6) Fuel Temperature : 40 – 45 °C (104 – 113 °F)

Pump Speed (rpm) Rack Travel Number of Delivery Quantity Max. Spread in
Remarks
(mm) Strokes (cc/cyl.) Delivery (cc)
950 10.6 200 17.8 – 19.0 1.6
550 11.4 200 23.4 – 24.6 1.6
300 About 9.3 (RW 1) 500 10.0 – 12.0 1.0 Check

Overflow valve opening : 1.6 kgf/cm 2

3.ADJUSTMENT OF GOVERNOR...Refer to the right side of this sheet.

4.ADJUSTMENT OF PUMP WITH GOVERNOR OPERATION

Lever Position Pump Speed Delivery Quantity


Number of Strokes Remarks
(deg) (rpm) (cc/cyl.)
FULL 950 1000 90 – 94
550 1000 117 – 123

5. ADJUSTMENT OF TIMER N.A. : Not Applicable


Pump Speed
N.A.
(rpm)

Advance Angle
N.A.
(deg)
190000-8870

Control Speed Range : 300 – 950 rpm X = 1.5 – 2.5

6.ADJUSTMENT OF BOOST COMPENSATOR (Full lever position)

Pump Speed Boost Pressure (mmHg) RW Delivery Quantity (cc/200st)


(rpm) (mm)
N.A. N.A. N.A. N.A.

NOTE:
(1) Adjusting Lever Angle
Setting position 40° to be at vertical position.
(2) Adjusting Lever Operation
Rack travel should be 0 – 4 mm when the adjusting lever is at stop position (VH = -25° – -15°) and pump speed 0 rpm.
(3) Refer to 'ADJUSTMENT OF DELIVERY QUANTITY' fo RW 1.