EB8870
EB8870
EB8870
1.INJECTION TIMING
Test Conditions
Pump Speed (rpm) Rack Travel Number of Delivery Quantity Max. Spread in
Remarks
(mm) Strokes (cc/cyl.) Delivery (cc)
950 10.6 200 17.8 – 19.0 1.6
550 11.4 200 23.4 – 24.6 1.6
300 About 9.3 (RW 1) 500 10.0 – 12.0 1.0 Check
Advance Angle
N.A.
(deg)
190000-8870
NOTE:
(1) Adjusting Lever Angle
Setting position 40° to be at vertical position.
(2) Adjusting Lever Operation
Rack travel should be 0 – 4 mm when the adjusting lever is at stop position (VH = -25° – -15°) and pump speed 0 rpm.
(3) Refer to 'ADJUSTMENT OF DELIVERY QUANTITY' fo RW 1.