0% found this document useful (0 votes)
128 views1 page

Transmission Line Trainer

Xpo pet/tl

Uploaded by

robinwilson888
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
128 views1 page

Transmission Line Trainer

Xpo pet/tl

Uploaded by

robinwilson888
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 1
POWER TRANSMISSION LINE TRAINER (Model : XPO-PET-TL) SALIENT FEATURES ‘© Simulates 400 Kv, 50 60Hz, 3 Phase INVA. Transmission Line by ‘scalngitdownby 1000:1, Optional second TL maybe suppiedtor3bus ‘patients. ‘¢ XPO-PETITL Traine need a few set of assciled panels which re mounted ina ght weight study alurioum profle fat demo modular panelsystom, ‘© Facies easy and safe wring by students de to use of dm sturdy Technical Specifications ‘¢ Input3 phase DOL Starter pane!(EMT1) © Apole MCB of415 Vi4A, ‘© DOL2AContactorwith230V/50Hz/11VACOIL + Bimetalc thermal iLrelay with range2.5A-6A ¢ FWD-OFF-REV, Switch Panel EMT 4A) + FWDIREV, 3pole 3 way switch with center OFF, 6AVAAOV, ‘Integrated AC 3 phasemeasurementpanel EMT 34)X2 ‘+ Consistof (96X96 mm) Digitalmetersfor3 phase, ‘+ Measures VI, PF (0.2 lag — unity 0.2 lead, Hz. Hence separate analog wattmeters (ph, ‘ph. arenotneeded ‘¢ VAR Compensation pane! dual panel) (EMT43) ‘+ Consisting of VAR compensating capacitors of 2, 4, 6, 8, 10 & ‘45uF eachof3 nos wih pole 7 way switch for selection. ‘Transmission tine Panel (EMT38) Table Top Panel consisting of: ‘+ Can Simulate model fr transmission line constructed using R(10 ‘ohmi600W), L(0.1SH'5A) and © (2.2UF/620V) 6 No. each ‘component. + Can Simulate madel for mediumilong (125 km250 km) length transmission line for model ‘+ Can Simulate model for mediumvlong (125 kmi250 km) length ‘transmission tine for model ‘» Fancooled top setup forlonglie © RLCloadpanel EMTAZAIBIC ‘Table Top Panel consisting of: ‘+ 310s of 600W resistors with switch selectable tot +6 tap nos. of tapsat 100,112,150, 175,200 8 225 ohm SI. ap 0262 ohm. ‘+ 3nos. of nductor 1.5H/*A with switch selectable ot) + 6 tp nos oftaps at03,0.8,0.75,0.9, 128 1.5H. ‘Shrouded banana paich cords and shrouded socket arrangements for highvotageceuts Each panel has ABS molied plastic sturdy enclosure, and color Sérewless overlays showing cuts diagrams & is connection tag rurersforeasyundersiandingand connecion. Uselulfor Under Graduate Practcals & Post Graduate projets. Setof nsrutor Guide & Student Workbook ‘© Capacitors 440VAC rating (3 nos, one per phase) with switch selectable 7 nasofvaluec2, 5,10, 15,20, 308 SOF. Fancooledtop setup forlonglife ‘@ 3phase dimmer panelEMTZ00 Table Top Panel consisting of: ‘© phase dimmerl/P:415VAC, 50H, OIP:0-470V AC, 6A, 3phase, List of Experiments 1, Working wih bi-directional 3 AC measurement panel, observing flow of eal & reactive power & optionally modus communication withPC. 2. Nolbadtest&Ferrant effect 3, Determination of transmission line constants (ABCD) by experimental measurement using 2-port method as well as by knowing comporents values andit verfication, 4, Load Test & Calculation of Regulation, ficiency of Transmission Line. 5. Working with power circle diagram & to find steady slate power limtot vansmission ine Capacitive VAR compensation Perunitrepresentation ‘Symmetical& unsymmetrcalfaulsin transmission line. Predicting Power Flow in Transmission Line (2 bus) by Numerical ‘method [Newton Raphson Gauss-Seidel Method) ‘¢ Mechanical Dimension mm) & Weight of Trainer: ‘170(L) x300(W)x990 () © NotWt.:45kg. Gross Wt. 55kg ‘¢ EMT200:53kg. EMT 42:60kg, EMT 38:103kg. ‘# DCmotorNetWt.:40kg, Gross Wt: 52kg. 160808

You might also like