Series 356 - ASCO Direct Operated Solenoid Valves G1-8 G1-4 1
Series 356 - ASCO Direct Operated Solenoid Valves G1-8 G1-4 1
Series 356 - ASCO Direct Operated Solenoid Valves G1-8 G1-4 1
1
3/2
Series
direct operated
3 2
1/8 - 1/4 U
1
3 2
356
NO
3 2
FEATURES
• Compact design for the control of single-acting actuators or filling and draining
cycles
• Wide range of flow and pressure ratings
• Quick disassembly of core tube for easy maintenance of internal parts
• Standard disc seal made of FPM suitable for a wide range of operating tempera-
tures and compatible with many fluids
• Standard manual operator allows an easy installation
• AC/DC interchangeability of the solenoid without disassembly of the valve
• Compliance with UL and CSA standards (coil 4/6,9 W)
• Compact and low weight valve
• The solenoid valves satisfy all relevant EC directives
GENERAL
Differential pressure See «SPECIFICATIONS» [1 bar =100 kPa]
Maximum viscosity 40 cSt (mm2/s)
Response time 5 - 10 ms
fluids () temperature range (TS) seal materials ()
air, inert gas, water, oil -10°C to +100°C FPM (fluoroelastomer)
3
MATERIALS IN CONTACT WITH FLUID
() Ensure that the compatibility of the fluids in contact with the materials is verified
Brass body Stainless steel body
Body Brass AISI 316
Core tube Stainless steel Stainless steel
Core and plugnut Stainless steel Stainless steel
Springs Stainless steel Stainless steel
Seat
Seals
Disc
Brass
FPM
FPM
Stainless steel
FPM
FPM
E
Shading coil Copper Copper 2 1
ELECTRICAL CHARACTERISTICS NC function
Coil insulation class F 3
Connector Spade plug (cable Ø 6-8 mm or Ø 6-10 mm)
Connector specification DIN 43650, 11 mm, industry standard B (type 01)
or ISO 4400 / EN 175301-803, form A (type 02)
Electrical safety IEC 335
Electrical enclosure protection Moulded IP65 (EN 60529)
Standard voltages DC (=) : 24V - 48V
(Other voltages and 60 Hz on request) AC (~) : 24V - 48V - 115V - 230V / 50 Hz
power ratings operator
ambient replacement coil
prefix inrush holding hot/cold temperature type (1)
option ~ ~ = range (TS) ~ =
(VA) (VA) (W) (W) (C°) 2 1
230 V/50 Hz 24 V DC
12 6 4 5 / 6,9 -10 to +60 400127-197 400127-142 01 NO function
SC
15 7 5 5 / 6,9 -10 to +60 400727-117 400727-185 02
(1)
Refer to the dimensional drawings on the following page.
Availability, design and specifications are subject to change without notice. All rights reserved.
SPECIFICATIONS
operating pressure options
flow differential (bar) catalogue
pipe orifice coefficient max. (PS) power coil
number
size size Kv (W)
air, water,
min.
oil ()
EPDM
NO - Normally open
1/8 (2) 1,6 0,096 1,6 0,05 0,8 0 8,5 8,5 4 6,9 SCG356B006VMS SCG356B018VMS E - -
(2)
Pipe size port 3: M5 (Orifice size = 1,2 mm).
Pneutrol International Ltd are Platinium Distributors for ASCO Numatics V504-1
Contact us : 5 Caulside Drive, Antrim, Northern Ireland, BT41 2DU www.valves-direct.com [email protected] Tel: +44 (0) 28 9448 1800
SOLENOID VALVES SERIES 356
OPTIONS
• Valves can also be supplied with EPDM (ethylene-propylene) seals and discs. Use the appropriate optional suffix letter for
identification (1/8 version only)
• Explosionproof enclosures for use in zones 1/21-2/22, categories 2-3 to ATEX Directive 94/9/EC (see “Explosionproof solenoids” section)
• Flying leads coil, use prefix L (e.g.: LG356B001VMS) (4 W/6,9 W coil only)
• Oxygen service with seals and disc in FPM, suffix NV, example: SCG356B001NVMS
• Solenoid valves integrated on manifold, orifice sizes 1,2 - 1,6 - 2 - 2,4 mm (See V591)
• French sanitary conformity approval ACS for potable water applications, suffix: FW (1/8 NC only)
• Without manual operator, on request
• Other pipe connections are available on request
• Plug with visual indication and peak voltage suppression or with cable length of 2 m (see Solenoids, Coils & Accessories section)
INSTALLATION
• The solenoid valves can be mounted in any position without affecting operation
• Solenoid valves have 2 mounting holes in body
• Pipe connection identifier is G = G (ISO 228/1)
• Installation/maintenance instructions are included with each valve
ORDERING EXAMPLES:
SC G 356 B 001 VMS 230V / 50 Hz
SC G 356 B 002 EMS 115V / 50 Hz
SC G 356 B 014 NVMS 24V / DC
SC G 356 B 001 FWMS 24V / DC
SC G 356 B 456 VMS 230V / 50 Hz
SC G 356 B 006 VMS 230V / 50 Hz
prefix
pipe thread voltage
basic number suffix
18
15
21
R=3 18 2 x Ø M3 2 x Ø M3
Availability, design and specifications are subject to change without notice. All rights reserved.
R=3
E A 35 35
A
B E
B C
C
3 M5
3 M5
360°
360° J G J
G
H H
X X
2 1 2 1
D K K
F 1 D F
type A B C D E F G H J K X
option size brass stainless steel
01 SC 1/8 60,5 27,5 16,5 33 22 25,5 46 53 69 15 18,6 0,156 0,138
02 SC 1/4 76 38 23,3 40 29,7 28,5 48 57 79 15 23.4 0,232 0,229
(1)
including coil and connector.