Vci Seaworthy Hdpe Paper

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

A trusted name for rust/corrosion

free packaging..since 1995


http://www.aerographicpapers.com
Email: [email protected]

Aerographic's Packaging System for Coils


Steel mills generally pack the CR as well as GI coils / sheets in polythene strips /
Hessian cloth. This packing system was known as bandage packing, where the coils
are wrapped with packing material of 8”–10” width packing material. This kind of
packing has the following drawbacks:

●Though they are overlapped, but still there are huge gaps between the layers. These
gaps allow moisture and air to reach the metal surface and cause corrosion
●Slipping of the layers exposes the metal surface to atmosphere which in turn causes

corrosion.
●The packing process is time consuming which increases labor cost.

●The process consumes more packing material which increases budget cost.

●If coils get rusted, the major portion of these steel coils are used in the automobile

sector, where rusted sheets, even after the process of sandblasting or removing the rust
cannot be used for quality reasons.
Advantages of Aerographic's VCI HDPE HD 115/A Paper:
Aerographic's Seaworthy Packaging System developed for packing steel coils
overcomes these problems completely. It provides superior protection to the steel coils
and ensures that the end user receives the coils in factory fresh condition. The overall
packing works out economical over the customary packing.

Aerographic's Seaworthy Packaging System, involves using a single sheet of multi


layered VCI chemical treated paper to wrap around the coil, as the primary packing
material instead of the normal polythene strips. An outer layer of stretch film or
ordinary polythene film can be used which is optional. This is followed by the use of
edge guard, strapping, metal foil packing etc depending on the product and the
destination.
Coil Packaging In 9 Simple Steps
1 4 7

Fresh edges slitted coil Strapping around the OD to hold the Fixing metal protectors on the
from mill VCI paper & metal sheet on the coil sides and metal edge protectors
on ID & OD straps
2 5 8

Placing the coil on HDPE fabric Tucking the VCI paper in to Coil Packing complete
laminated VCI paper & metal sheet cover the edges and ID

3 6 9

Wrapping the coil in HDPE Fixing the paper edge Coil awaiting dispatch
Fabric Laminated VCI paper guard on the OD and ID
& metal sheet
Specifications and Test Results of HD 115/A
Technical Specifications

1. Thickness of Material = 180 gm +- 10%


Layer 1 - LDPE Lamination 20 X 20 GSM
Layer 2 - HDPE Fabric 60 GSM – Mesh Size 10x10 mesh
Layer 3 - LDPE Lamination 20 GSM
Layer 4 – VCI Paper 75 GSM
Coating – 20GSM
2. Burst Factor of Paper – 4.5 kg/sq cm
3. Burst Factor of HDPE - 12.3 kg/ sq cm
4. Tear Factor DIR I– 1285
5. DIR II – 800
6. Weight of total uncoated material – 170- 180 grams per sq m (High Heavy Duty)
7. pH of treated Paper – 7.0 +- 1
8. Vapour inhibiting humidity chamber test for 120+hours – PASS
9. Contact corrosion test in humidity chamber test for 120+ hours – PASS
10. Water penetration test for 16 hours - PASS
Salt Spray Report
Test Method ASTM B-117
Test Solution 5% Sodium Chloride in DI Water
PH Of Fog Controlled 6.5-7.2 at 35oC

Observation After 96 Hours:


No red rust, No white rust observed.